Search NASA⌕ Search

DOE OSTI · 21120701

Stepwise multi-criteria optimization for robotic radiosurgery

Abstract

Achieving good conformality and a steep dose gradient around the target volume remains a key aspect of radiosurgery. Clearly, this involves a trade-off between target coverage, conformality of the dose distribution, and sparing of critical structures. Yet, image guidance and robotic beam placement have extended highly conformal dose delivery to extracranial and moving targets. Therefore, the multi-criteria nature of the optimization problem becomes even more apparent, as multiple conflicting clinical goals need to be considered coordinate to obtain an optimal treatment plan. Typically, planning for robotic radiosurgery is based on constrained optimization, namely linear programming. An extension of that approach is presented, such that each of the clinical goals can be addressed separately and in any sequential order. For a set of common clinical goals the mapping to a mathematical objective and a corresponding constraint is defined. The trade-off among the clinical goals is explored by modifying the constraints and optimizing a simple objective, while retaining feasibility of the solution. Moreover, it becomes immediately obvious whether a desired goal can be achieved and where a trade-off is possible. No importance factors or predefined prioritizations of clinical goals are necessary. The presented framework forms the basis for interactive and automated planning procedures. It is demonstrated for a sample case that the linear programming formulation is suitable to search for a clinically optimal treatment, and that the optimization steps can be performed quickly to establish that a Pareto-efficient solution has been found. Furthermore, it is demonstrated how the stepwise approach is preferable compared to modifying importance factors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Schlaefer, A, Schweikard, A. 2008-05-15. Stepwise multi-criteria optimization for robotic radiosurgery. https://doi.org/10.1118/1.2900716. https://searchnasa.com/record/osti%3A21120701/stepwise-multi-criteria-optimization-for-robotic-radiosurgery

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗