Search NASA⌕ Search

DOE OSTI · 22096830

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Abstract

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Neukirchen, Christoph, Giordano, Marco, Wiesner, Steffen. 2010-12-15. An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach. https://doi.org/10.1118/1.3495818. https://searchnasa.com/record/osti%3A22096830/an-iterative-method-for-tomographic-x-ray-perfusion-estimation-in-a-decomposition-model-based-approa

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗