Search NASA⌕ Search

DOE OSTI · 22262814

A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning

Abstract

Monte Carlo (MC) simulation is currently the most accurate dose calculation algorithm in radiotherapy planning but requires relatively long processing time. Faster model-based algorithms such as the anisotropic analytical algorithm (AAA) by the Eclipse treatment planning system and multigrid superposition (MGS) by the XiO treatment planning system are 2 commonly used algorithms. This study compared AAA and MGS against MC, as the gold standard, on brain, nasopharynx, lung, and prostate cancer patients. Computed tomography of 6 patients of each cancer type was used. The same hypothetical treatment plan using the same machine and treatment prescription was computed for each case by each planning system using their respective dose calculation algorithm. The doses at reference points including (1) soft tissues only, (2) bones only, (3) air cavities only, (4) soft tissue-bone boundary (Soft/Bone), (5) soft tissue-air boundary (Soft/Air), and (6) bone-air boundary (Bone/Air), were measured and compared using the mean absolute percentage error (MAPE), which was a function of the percentage dose deviations from MC. Besides, the computation time of each treatment plan was recorded and compared. The MAPEs of MGS were significantly lower than AAA in all types of cancers (p<0.001). With regards to body density combinations, the MAPE of AAA ranged from 1.8% (soft tissue) to 4.9% (Bone/Air), whereas that of MGS from 1.6% (air cavities) to 2.9% (Soft/Bone). The MAPEs of MGS (2.6%±2.1) were significantly lower than that of AAA (3.7%±2.5) in all tissue density combinations (p<0.001). The mean computation time of AAA for all treatment plans was significantly lower than that of the MGS (p<0.001). Both AAA and MGS algorithms demonstrated dose deviations of less than 4.0% in most clinical cases and their performance was better in homogeneous tissues than at tissue boundaries. In general, MGS demonstrated relatively smaller dose deviations than AAA but required longer computation time.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tse, Teddy K.H., Ho, Cola L.M., Yeung, Eric C.Y.. 2013-07-01. A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning. https://doi.org/10.1016/j.meddos.2013.02.001. https://searchnasa.com/record/osti%3A22262814/a-comparison-between-anisotropic-analytical-and-multigrid-superposition-dose-calculation-algorithms

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACRRF High-Bay Dose Calculations using MCNP (Part B)

ACRR radiation outputs through vertical cavities have been documented in two reports. In Part B, the maximum dose from the unshielded central cavity, FREC-II, and NRS is calculated to inform the safety basis. The maximum dose is ≈1430 mrem per 300 MJ, or ≈40,930 rem/hr for full-power operation. A verification study completes the V&V of the modeling. Supplementary studies of variance-reduction techniques, model sensitivities, and aircraft dose above the ACRRF are included.

61 RADIATION PROTECTION AND DOSIMETRY↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗