DOE OSTI · 2341463
System Study: Residual Heat Removal 1998-2022
Abstract
This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and in response to post-trip shutdown cooling) at 93 U.S. commercial operating nuclear reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database. The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RHR results.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Ma, Zhegang, Kvarfordt, Kellie J., Wierman, Thomas. 2023-12-01. System Study: Residual Heat Removal 1998-2022. https://doi.org/10.2172/2341463