Search NASA⌕ Search

DOE OSTI · 2349193

Continuous-wave GaAs/AlGaAs quantum cascade laser at 5.7 THz

Abstract

Design strategies for improving terahertz (THz) quantum cascade lasers (QCLs) in the 5–6 THz range are investigated numerically and experimentally, with the goal of overcoming the degradation in performance that occurs as the laser frequency approaches the Reststrahlen band. Two designs aimed at 5.4 THz were selected: one optimized for lower power dissipation and one optimized for better temperature performance. The active regions exhibited broadband gain, with the strongest modes lasing in the 5.3–5.6 THz range, but with other various modes observed ranging from 4.76 to 6.03 THz. Pulsed and continuous-wave (cw) operation is observed up to temperatures of 117 K and 68 K, respectively. In cw mode, the ridge laser has modes up to 5.71 THz – the highest reported frequency for a THz QCL in cw mode. The waveguide loss associated with the doped contact layers and metallization is identified as a critical limitation to performance above 5 THz.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shahili, Mohammad, Addamane, Sadhvikas Jayachandra, Kim, Anthony D., Curwen, Christopher A., Kawamura, Jonathan H., Williams, Benjamin S.. 2024-01-16. Continuous-wave GaAs/AlGaAs quantum cascade laser at 5.7 THz. https://doi.org/10.1515/nanoph-2023-0726

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗