Search NASA⌕ Search

DOE OSTI · 2500376

Exploring Local Ionic Motion in Perovskite Solar Cells at Nanoscale through Scanning Thermo-Ionic Microscopy

Abstract

We investigate the local ionic motion in the absorber layer of perovskite solar cells using scanning thermo-ionic microscopy (STIM). STIM images of perovskite films show higher STIM amplitude at most of the grain boundaries due to higher ionic motion at those regions. The perovskite absorber layer of devices aged under blue (450 nm) light soaking shows higher amplitude in STIM signal compared to controls kept in dark storage. Such enhancement of STIM amplitude upon aging under light implies an increased concentration or diffusivity (or both) of mobile ionic species in stressed devices. Our results demonstrate the utilization of the STIM technique to assess and understand the intrinsic local ionic motion in perovskite absorbers for further advancement in device stability and functionality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paul, G. (ORCID:0009000366341203), Schall, J. W., Migliozzi, M., Palmstrom, A., Johnston, S. (ORCID:0000000333088267), Al-Jassim, M. M., Jiang, C.-S., Kern, D. B.. 2024-11-15. Exploring Local Ionic Motion in Perovskite Solar Cells at Nanoscale through Scanning Thermo-Ionic Microscopy. https://doi.org/10.1109/pvsc57443.2024.10749300

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Non-equilibrium dynamics in geometrically frustrated spin glass Bi 2 Fe 3 GaO 9 with a Cairo lattice

We have explored the magnetic relaxation of the spin glass phase in Bi 2 Fe 3 GaO 9 , a geometrically frustrated magnet with a unique Cairo lattice made of pentagonal building blocks. Using dc magnetization measurements, we find the relaxation behavior in single crystals follows the Arrhenius law as a function of temperature but remains relatively constant under different magnetic fields. Through a carefully designed protocol, we observe significant rejuvenation and memory effects, reminiscent of classical dilute spin glasses rather than spin jamming systems. Our finding suggests that Bi 2 Fe 3 GaO 9 is probably located in the crossover between conventional spin glass and perfect spin jam and thus provides an excellent platform for investigating the evolution of underlying magnetic structure, paving the way for further neutron scattering research.

aging↗

Exploring Electrode-Level State-of-Charge and State-of-Health Dynamics in Lithium-Ion Battery Cells: Modeling and Experimental Identification

A computationally efficient model serves as a critical prerequisite for battery performance analysis and advanced battery management algorithm design. Although battery models that capture cell-level behavior have been widely explored in existing literature, electrode-level battery models have received much lesser attention till to date. However, such electrode-level models can significantly increase battery performance and life by enabling electrode-level health-conscious control. Such electrode-level control can effectively expand usable energy and power limits of the battery cells by utilizing the knowledge of individual electrodes' charge and health. In this context, this paper presents a comprehensive battery model developed with a reference electrode insertion that captures (i) electrode-level charge/discharge dynamics, (ii) stoichiometric and temporal dependencies of electrode-level resistances, (iii) solid electrolyte interface (SEI) layer growth as key degradation phenomenon, and (iv) capacity fade and resistance rise in each electrode due to nominal battery aging. The proposed model is identified, and a preliminary validation is performed utilizing terminal voltage and negative electrode potential data collected from a pouch cell under one continuous cycling and accelerated aging conditions where the cell experienced 14% capacity loss.

aging↗

Diagnosis of PV Cell Passivation Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.

aging↗