Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

Adam, W. [Vienna, OAW]·Bergauer, T. [Vienna, OAW]·Dragicevic, M. [Vienna, OAW]·Frühwirth, R. [Vienna, OAW]·Steininger, H. [Vienna, OAW]·Beaumont, W. [Antwerp U.]·Janssen, T. [Antwerp U.]·Kwon, H. [Antwerp U.]·Henao, D. Ocampo [Antwerp U.]·Van Laer, T. [Antwerp U.]·Van Mechelen, P. [Antwerp U.]·Bierkens, J. [Vrije U., Brussels]·Breugelmans, N. [Vrije U., Brussels]·Delcourt, M. [Vrije U., Brussels]·De Moor, A. [Vrije U., Brussels]·D'Hondt, J. [Vrije U., Brussels]·Heyen, F. [Vrije U., Brussels]·Lowette, S. [Vrije U., Brussels]·Makarenko, I. [Vrije U., Brussels]·Tytgat, M. [Vrije U., Brussels]·Van Putte, S. [Vrije U., Brussels]·Allard, Y. [Brussels U.]·Bilin, B. [Brussels U.]·Clerbaux, B. [Brussels U.]·Caviglia, F. [Brussels U.]·Dansana, S. [Brussels U.] (ORCID:0000000277527471)·Das, A. [Brussels U.]·De Lentdecker, G. [Brussels U.]·Ducarme, E. [Brussels U.]·Evard, H. [Brussels U.]·Favart, L. [Brussels U.]·Kalaitzidou, I. [Brussels U.]·Khalilzadeh, A. [Brussels U.]·Korntheuer, M. [Brussels U.]·Malara, A. [Brussels U.]·Robert, F. [Brussels U.]·Shahzad, M. A. [Brussels U.]·Thomas, L. [Brussels U.]·Vanden Bemden, M. [Brussels U.]·Vanlaer, P. [Brussels U.]·Yang, Y. [Brussels U.]·Yuan, C. [Brussels U.]·Zhang, F. [Brussels U.]·Bein, S. [Louvain U., CP3]·Benecke, A. [Louvain U., CP3]·Bethani, A. [Louvain U., CP3]·Bruno, G. [Louvain U., CP3]·Cappati, A. [Louvain U., CP3]·De Favereau, J. [Louvain U., CP3]·Delaere, C. [Louvain U., CP3]·Giammanco, A. [Louvain U., CP3]·Guzel, A. O. [Louvain U., CP3]·Jain, S. [Louvain U., CP3]·Lemaitre, V. [Louvain U., CP3]·Lidrych, J. [Louvain U., CP3]·Malek, P. [Louvain U., CP3]·Mastrapasqua, P. [Louvain U., CP3]·Szilasi, N. [Louvain U., CP3]·Turkcapar, S. [Louvain U., CP3]·Brigljević, V. [Boskovic Inst., Zagreb]·Chitroda, B. [Boskovic Inst., Zagreb]·Ferenček, D. [Boskovic Inst., Zagreb]·Jakovcic, K. [Boskovic Inst., Zagreb]·Starodumov, A. [Boskovic Inst., Zagreb]·Šuša, T. [Boskovic Inst., Zagreb]·Brücken, E. [Helsinki U.]·Hildén, T. [Helsinki Inst. of Phys.]·Lampén, T. [Helsinki Inst. of Phys.]·Saariokari, S. [Helsinki Inst. of Phys.]·Karadzhinova-Ferrer, A. [Lappeenranta U. Tech.]·Luukka, P. [Lappeenranta U. Tech.]·Petrow, H. [Lappeenranta U. Tech.]·Tuuva, T. [Lappeenranta U. Tech.]·Väänänen, M. [Lappeenranta U. Tech.]·Agram, J.-L. [Strasbourg, IPHC]·Andrea, J. [Strasbourg, IPHC]·Bloch, D. [Strasbourg, IPHC]·Bonnin, C. [Strasbourg, IPHC]·Brom, J.-M. [Strasbourg, IPHC]·Chabert, E. [Strasbourg, IPHC]·Charles, L. [Strasbourg, IPHC]·Collard, C. [Strasbourg, IPHC]·Dangelser, E. [Strasbourg, IPHC]·Falke, S. [Strasbourg, IPHC]·Goerlach, U. [Strasbourg, IPHC]·Gross, L. [Strasbourg, IPHC]·Haas, C. [Strasbourg, IPHC]·Krauth, M. [Strasbourg, IPHC]·Ollivier-Henry, N. [Strasbourg, IPHC]·Poncet, O. [Strasbourg, IPHC]·Saha, G. [Strasbourg, IPHC]·Vaucelle, P. [Strasbourg, IPHC]·Baulieu, G. [IP2I, Lyon]·Bonnevaux, A. [IP2I, Lyon]·Boudoul, G. [IP2I, Lyon]·Caponetto, L. [IP2I, Lyon]·Chanon, N. [IP2I, Lyon]·Contardo, D. [IP2I, Lyon]·Dupasquier, T. [IP2I, Lyon]·Fillaudeau, E. [IP2I, Lyon]

Abstract

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

Explore related subjects

Keep this discovery

BibTeXRIS

Adam, W. [Vienna, OAW], Bergauer, T. [Vienna, OAW], Dragicevic, M. [Vienna, OAW], Frühwirth, R. [Vienna, OAW], Steininger, H. [Vienna, OAW], Beaumont, W. [Antwerp U.], Janssen, T. [Antwerp U.], Kwon, H. [Antwerp U.], Henao, D. Ocampo [Antwerp U.], Van Laer, T. [Antwerp U.], Van Mechelen, P. [Antwerp U.], Bierkens, J. [Vrije U., Brussels], Breugelmans, N. [Vrije U., Brussels], Delcourt, M. [Vrije U., Brussels], De Moor, A. [Vrije U., Brussels], D'Hondt, J. [Vrije U., Brussels], Heyen, F. [Vrije U., Brussels], Lowette, S. [Vrije U., Brussels], Makarenko, I. [Vrije U., Brussels], Tytgat, M. [Vrije U., Brussels], Van Putte, S. [Vrije U., Brussels], Allard, Y. [Brussels U.], Bilin, B. [Brussels U.], Clerbaux, B. [Brussels U.], Caviglia, F. [Brussels U.], Dansana, S. [Brussels U.] (ORCID:0000000277527471), Das, A. [Brussels U.], De Lentdecker, G. [Brussels U.], Ducarme, E. [Brussels U.], Evard, H. [Brussels U.], Favart, L. [Brussels U.], Kalaitzidou, I. [Brussels U.], Khalilzadeh, A. [Brussels U.], Korntheuer, M. [Brussels U.], Malara, A. [Brussels U.], Robert, F. [Brussels U.], Shahzad, M. A. [Brussels U.], Thomas, L. [Brussels U.], Vanden Bemden, M. [Brussels U.], Vanlaer, P. [Brussels U.], Yang, Y. [Brussels U.], Yuan, C. [Brussels U.], Zhang, F. [Brussels U.], Bein, S. [Louvain U., CP3], Benecke, A. [Louvain U., CP3], Bethani, A. [Louvain U., CP3], Bruno, G. [Louvain U., CP3], Cappati, A. [Louvain U., CP3], De Favereau, J. [Louvain U., CP3], Delaere, C. [Louvain U., CP3], Giammanco, A. [Louvain U., CP3], Guzel, A. O. [Louvain U., CP3], Jain, S. [Louvain U., CP3], Lemaitre, V. [Louvain U., CP3], Lidrych, J. [Louvain U., CP3], Malek, P. [Louvain U., CP3], Mastrapasqua, P. [Louvain U., CP3], Szilasi, N. [Louvain U., CP3], Turkcapar, S. [Louvain U., CP3], Brigljević, V. [Boskovic Inst., Zagreb], Chitroda, B. [Boskovic Inst., Zagreb], Ferenček, D. [Boskovic Inst., Zagreb], Jakovcic, K. [Boskovic Inst., Zagreb], Starodumov, A. [Boskovic Inst., Zagreb], Šuša, T. [Boskovic Inst., Zagreb], Brücken, E. [Helsinki U.], Hildén, T. [Helsinki Inst. of Phys.], Lampén, T. [Helsinki Inst. of Phys.], Saariokari, S. [Helsinki Inst. of Phys.], Karadzhinova-Ferrer, A. [Lappeenranta U. Tech.], Luukka, P. [Lappeenranta U. Tech.], Petrow, H. [Lappeenranta U. Tech.], Tuuva, T. [Lappeenranta U. Tech.], Väänänen, M. [Lappeenranta U. Tech.], Agram, J.-L. [Strasbourg, IPHC], Andrea, J. [Strasbourg, IPHC], Bloch, D. [Strasbourg, IPHC], Bonnin, C. [Strasbourg, IPHC], Brom, J.-M. [Strasbourg, IPHC], Chabert, E. [Strasbourg, IPHC], Charles, L. [Strasbourg, IPHC], Collard, C. [Strasbourg, IPHC], Dangelser, E. [Strasbourg, IPHC], Falke, S. [Strasbourg, IPHC], Goerlach, U. [Strasbourg, IPHC], Gross, L. [Strasbourg, IPHC], Haas, C. [Strasbourg, IPHC], Krauth, M. [Strasbourg, IPHC], Ollivier-Henry, N. [Strasbourg, IPHC], Poncet, O. [Strasbourg, IPHC], Saha, G. [Strasbourg, IPHC], Vaucelle, P. [Strasbourg, IPHC], Baulieu, G. [IP2I, Lyon], Bonnevaux, A. [IP2I, Lyon], Boudoul, G. [IP2I, Lyon], Caponetto, L. [IP2I, Lyon], Chanon, N. [IP2I, Lyon], Contardo, D. [IP2I, Lyon], Dupasquier, T. [IP2I, Lyon], Fillaudeau, E. [IP2I, Lyon]. 2026-02-05. Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker. https://doi.org/10.1016/j.nima.2026.171359

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related reports

Mechanics and Cooling of the CMS Phase-II Tracker Barrel

The CMS upgrade for the High-Luminosity LHC (HL-LHC) era will allow for an incredibly high rate of data collection, to be used in the next generation of precision measurements and searches for beyond the standard model physics. A key element of this upgrade is the full replacement of the silicon strip tracker to enable level-1 triggering on track level primitives, produced by pixel-strip (PS) and strip-strip (2S) modules, tiled together to form the new detector. Mechanically supporting and cooling these modules is not trivial, as material budget in the tracker volume is highly constrained, and as the modules accrue radiation damage they risk becoming entirely non-functional if the silicon sensors are not sufficiently cooled. To address this, each region of the tracker has a bespoke solution for housing and cooling their modules, mostly depending on carbon-fiber and carbon-foam structures, with dual phase CO2 cooling. For the most central part of the tracker, the Flat Barrel with PS modules (Flat TBPS) covers the pseudorapidity range out to $|\eta|=0.4$, and the mechanical structures are manufactured, assembled, and tested entirely by Fermilab and UC Davis. This presentation will describe the intense design and testing requirements for these components, and how they will ensure strong performance of the tracker through the HL-LHC era.

Cosby, Christopher [Fermilab]

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]

Charmonium Transport in Heavy-Ion Collisions at the LHC

We provide an update on our semi-classical transport approach for quarkonium production in high-energy heavy-ion collisions, focusing on 𝐽/𝜓 and 𝜓(2𝑆) mesons in 5.02 TeV Pb-Pb collisions at the Large Hadron Collider (LHC) at both forward and mid-rapidity. In particular, we employ the most recent charm-production cross sections reported in pp collisions, which are pivotal for the magnitude of the regeneration contribution, and their modifications due to cold-nuclear-matter (CNM) effects. Multi-differential observables are calculated in terms of nuclear modification factors as a function of centrality, transverse momentum, and rapidity, including the contributions from feeddown from bottom hadron decays. For our predictions for 𝜓(2𝑆) production, the mechanism of sequential regeneration relative to the more strongly bound 𝐽/𝜓 meson plays an important role in interpreting recent ALICE data.