Search NASA⌕ Search

DOE OSTI · 934944

System Effectiveness Model Formulation

Abstract

Evaluation of system effectiveness has numerous pitfalls. System objectives may be poorly defined, may shift during the system life or may be hard to quantify. Further, individual perceptions of the quantifications may differ. Whatever the cause, system effectiveness has been an elusive term to quantitatively define. The proposed model presents a quantitative system effectiveness model and establishes a utilitarian approach for its use with the illustrative application to a nuclear safeguards system. The model uses the Type I and Type II statistical error rates as input to the component or subsystem effectiveness calculation which, when combined using a utilitarian methodology, quantify the overall system effectiveness. The methodology will use a survey of expert judgment to determine the relative importance of the individual subsystems through a statistically designed web survey. The web based survey will be available to nuclear material protection, control, and accounting experts attending the 2008 INMM conference. This model and methodology will provide a repeatable quantifiable measure for any system but in this case a simple safeguards system is used as an example.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Coates, Cameron W, Jackson, Denise F. 2008-01-01. System Effectiveness Model Formulation. https://searchnasa.com/record/osti%3A934944/system-effectiveness-model-formulation

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Safeguards Technology Program FY2026 Mid-Year Report for Project WBS# 24.1.3.3: Development of Procedures for Th-U Radiochronometry of Uranium Particles by LG-SIMS

Implementing 230 Th- 234 U radiochronometry of environmental uranium particles by large geometry secondary ion mass spectrometry (LG-SIMS) requires assessment, validation, and technical support before safeguards conclusions can be drawn from the information. This project investigates the most challenging aspects of LG-SIMS particle radiochronometry 230 Th- 234 U measurements through a collaboration between LANL and NIST, to provide best practices and procedures for determining high quality ages with optimized uncertainties. This includes exploration of reducing detector backgrounds, investigating the best ways to report uncertainties, and establishing recommended instrument setups.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FY26 Mid-Year Report

The goal of this project is to develop specific aspects of ultra-high-resolution microcalorimeter technologies that support IAEA Nuclear Material Laboratory needs and the goals of SP-1 19/NML-003 "Microcalorimetry Analysis Technique for NML" but are outside the scope of the SP-1. The focus is on commissioning, assembly, and testing of the microcalorimeter decay energy spectrometer with superconducting transition-edge sensors (TESs) and magnetic microcalorimeters (MMCs) in preparation for transfer to the IAEA Nuclear Material Laboratory.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗