Search NASASearch

SEARCH · Search NASA

Search Search NASA

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

Data-Driven Discovery and Experimental Validation of Solvent Polarity Effects on Conjugated Polymer Solution-to-Film Assembly Pathways

Understanding how solvent properties influence the solution-to-film assembly of conjugated polymers remains a critical challenge due to the complex and intertwined nature of polymer–solvent interactions. In this study, we integrate a data-driven framework with experimental validation to identify key parameters influencing the assembly and performance of poly[2,5-(2-octyldodecyl)-3,6-diketopyrrolopyrrole-alt-5,5-(2,5-di(thien-2-yl)thieno[3,2-b]thiophene)] (DPP-DTT) in organic field-effect transistors (OFETs). A machine learning (ML) approach identified the normalized Reichardt polarity parameter (E T N ) as a significant descriptor correlated with DPP-DTT hole mobility (μ). Systematic DPP-DTT devices fabricated using solvents across a wide E T N range revealed that higher E T N solvents yield enhanced μ. To elucidate the structural origins of high μ, we conducted comprehensive analyses using UV–vis–NIR spectroscopy and grazing incidence wide angle X-ray scattering (GIWAXS) measurements. The results revealed that films processed from high E T N solvents exhibit reduced paracrystallinity. By analyzing the solution-state behavior using optical microscopy and solution WAXS, we revealed polymer solubility differences in the various solvents and associated distinct polymer assembly pathways, elucidating why the high E T N solvent produces long-range ordered films. Notably, the high E T N solvent shows a pronounced preference for liquid-crystal (LC)-mediated assembly, providing a mechanistic explanation for the enhanced structural order. Therefore, these results demonstrate that solvent polarity, as evaluated by E T N , serves as an important parameter that plays a significant role in the DPP-DTT assembly pathway and resultant solid-state morphology. This work provides a strategy for integrating data science with experiments to identify critical parameters associated with complex polymer systems and helps guide rational process design for high-performance organic electronics.

36 MATERIALS SCIENCE

Henry’s Solubility and Diffusion Coefficients for 29 Volatile Organic Compounds in Polydimethylsiloxane Sylgard 184 at 293 K

Two-dimensional (2D) inverse gas chromatography (IGC) enables simultaneous determination of Henry’s solubility and Fickian diffusion coefficients for volatile organic compounds (VOCs) in polymer films. This technique offers a significant advantage over traditional cylindrical column IGC by providing precise control and measurement of the film thickness (here, 0.064 ± 0.002 mm), which is the critical length scale for accurate diffusivity determination. We apply this methodology to characterize VOC transport in Sylgard 184, a widely used polydimethylsiloxane (PDMS)-based polymer containing substantial silica filler content. At room temperature (20 °C), we measured solubility and diffusion coefficients for 29 common VOCs spanning diverse chemical functionalities, including alkanes, aromatics, chlorinated solvents, ketones, esters, and alcohols. Comparison with literature data for pure PDMS reveals that VOC solubility in Sylgard 184 is generally higher; for most non-hydrogen-bonding compounds it remains within a factor of 2 of pure PDMS, whereas alcohols are enhanced by roughly 1.8 to 3.7 times, which we attribute to favorable interactions with residual silanol groups on the silanized silica filler. Diffusion coefficients range from 1.0 × 10 –6 cm 2 /s (n-undecane) to 8.9 × 10–5 cm 2 /s (acetonitrile) and align well with extrapolated literature values for PDMS. This study provides essential thermodynamic and transport data for predicting VOC permeation in Sylgard 184 while demonstrating the utility of 2D IGC as a robust technique for characterizing rubbery polymer membranes across diverse industrial applications.

organic

Nonlocal Effect of Percolated Particle Networks on Viscoelasticity of Polymer–Filler Nanocomposites: A Mesoscale Simulation Study

With nanoparticles (NPs) as fillers, polymer nanocomposites (PNCs) usually exhibit enhanced mechanical properties. However, a direct connection between the microscopic structural relaxation and macroscopic mechanical properties of PNCs remains to be established. To investigate the micro-to-macro connection, we develop a mesoscale model, in which the NPbridging polymer chains are represented by a dynamic bonded interaction between NPs, and the bulk polymer matrix is implicitly modeled by overdamped Langevin dynamics. Extensive equilibrium simulations are performed to quantify the microscopic dynamics of model PNCs. Systematic analyses of modified Rouse dynamics, dynamic structure factor, and relaxation modulus uncover that the microscopic relaxation dynamics of PNCs are significantly decelerated across different length scales because of nonlocal effects of percolated particle networks a phenomenon that has not been adequately captured in prior simulation studies. We find that NPvolume- fraction and NP-bonding-energy barrier are the two critical variables that affect bulk viscoelasticity the most. The proposed mesoscale model is versatile and provides a powerful framework for studying structure−property relations of different PNCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

The Synthesis and Ring-Opening Metathesis Polymerization of Energetic Norbornene Materials

Energetic norbornenes are promising candidates toward the development of new energetic polymers due to the synthetic versatility of norbornene ring-opening metathesis polymerizations used in commercial applications. We report the synthesis of two energetic norbornene materials that can be made in two steps with modest yields, containing either trinitroethanol or fluorodinitroethanol substituents. The norbornene monomers were then polymerized, and the polymers were characterized by Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC), contact angle measurements, and proton and carbon nuclear magnetic resonance spectroscopies ( 1 H and 13 C{ 1 H} NMR). Additionally, small-scale safety data consisting of electrostatic discharge (ESD), friction (FS), and impact (IS) sensitivities were measured for the norbornene monomers and their resulting polymers. These analyses revealed that energetic norbornene materials are relatively insensitive and have densities comparable to that of TNT (1.47–1.81 g·cm –3 ).

36 MATERIALS SCIENCE

High-Q superconducting lumped-element resonators for low-mass axion searches

Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here, we present the design and implementation of a fixed-frequency superconducting resonator operating near 250 kHz, possessing an inductor volume of ∼1 liter and achieving an unloaded quality factor Q ≈ 2.1 × 10 6 . This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.

Bosons

Mechanically Accelerated Depolymerization of Entangled Linear Polymer Melts

Mechanical forces can enhance the chemical depolymerization of synthetic polymers when shear flow accelerates chain scission. To quantify the extent of mechanically-accelerated scission, the effect of simple shear flow (duration and strength) with low Weissenberg and Deborah numbers was investigated by considering the impact of applied work in both simple shear and shear dominated mixed flows. Hydrogenated polyisoprene was chosen as a model linear, entangled system. The conditions (strain amplitude, frequency, and shearing time) necessary to increase chain scission were assessed in the rubbery melt. Shear flow accelerated chain scission at higher temperatures, suggesting an activated process. Isothermal scission versus work curves were superposed by applying shift factors a T,S , whose Arrhenius-like temperature dependence gave an apparent activation energy for chain scission of ~ 110 kJ/mol, which is likely a combination of the activation energy of viscosity and bond energy. This work provides a base for quantifying the impact of shear on depolymerization of polymer melts and highlight the connection between viscous dissipation and scission chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Monitoring Depolymerization in Mesopores Using Dynamic Properties of Polymeric Melt Accessed via Dielectric Spectroscopy

Traditional design principles for heterogeneous catalysis guide the use of catalytic particles with mesosized (∼2–50 nm) pores to increase the number of surface-active sites by way of an increased surface area. However, the entry of long-chain polymers into such pores may be significantly limited by the size and entanglement of polymers in the melt state, thereby decreasing the number of accessible sites. Assessment of catalyst performance from traditional reactor-based studies averages over intrapore reaction events as well as reactions on the surface of a particle, resulting in an inability to distinguish between differences in site accessibility and activity. Techniques that assess the intrapore performance can inform the design of future heterogeneous catalysts for polymer upcycling. In this work, we demonstrate the use of broadband dielectric spectroscopy to monitor depolymerization of a polymer melt within mesopores via changes in the segmental relaxation time scale of amorphous polymer chains. In particular, we highlight the use of an anodic aluminum oxide (AAO) membrane as a readily available model for catalyst pores with a well-characterized pore morphology. The decrease in the segmental relaxation (α-relaxation) time of the melt with increasing chain scission emerges as a measure of the extent of polymer deconstruction inside mesopores. To demonstrate the utility of this technique, we demonstrate the decomposition of two commercial poly(propylene carbonate) polymers with different decomposition rates within mesopores. As the polymers depolymerize, their segmental relaxation time decreases as the molecular weight decreases (as predicted by the Fox–Flory equation). The BDS-measured change in segmental relaxation time mirrors the expected trend based on change in molecular weight measured by size exclusion chromatography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Erosion Results of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.

Erosion yield