Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - AIRFOILS - OSCILLATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments

Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.

42 ENGINEERING↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

University of Nebraska unmanned aerial system (UAS) profiling during the LAPSE-RATE field campaign

Abstract. This paper describes the data collected by the University of Nebraska-Lincoln (UNL) as part of the field deployments during the Lower Atmospheric Process Studies at Elevation – a Remotely-piloted Aircraft Team Experiment (LAPSE-RATE) flight campaign in July 2018. The UNL deployed two multirotor unmanned aerial systems (UASs) at multiple sites in the San Luis Valley (Colorado, USA) for data collection to support three science missions: convection initiation, boundary layer transition, and cold air drainage flow. We conducted 172 flights resulting in over 21 h of cumulative flight time. Our novel design for the sensor housing onboard the UAS was employed in these flights to meet the aspiration and shielding requirements of the temperature and humidity sensors and to separate them from the mixed turbulent airflow from the propellers. Data presented in this paper include timestamped temperature and humidity data collected from the sensors, along with the three-dimensional position and velocity of the UAS. Data are quality-controlled and time-synchronized using a zero-order-hold interpolation without additional post-processing. The full dataset is also made available for download at https://doi.org/10.5281/zenodo.4306086 (Islam et al., 2020).

Islam, Ashraful (ORCID:000000022826269X)↗

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

Motor and drive arrangement for refrigeration system

A heat exchanger system includes a heat exchanger coil circulating a first heat transfer fluid therethrough, and a fan at least partially surrounded by the heat exchanger coil to urge a flow of air through the heat exchanger coil to dissipate thermal energy from the first heat transfer fluid. A brushless direct current fan motor is located the fan to urge rotation of the fan and an ancillary electrical component operably connected to the heat exchanger system and electrically isolated from the first heat transfer fluid.

Feng, Yinshan↗

Blades and systems with forward blowing slots

A blade for use in a wind turbine comprises a pressure side and suction side meeting at a trailing edge and leading edge. The pressure side and suction side provide lift to the turbine blade upon the flow of air from the leading edge to the trailing edge and over the pressure side and suction side. The blade includes one or more openings at the suction side, in some cases between the leading edge and the trailing edge. The one or more openings are configured to provide a pressurized fluid towards the leading edge of the blade, in some cases at an angle between about 0° and 70° with respect to an axis oriented from a centerline of the blade toward the leading edge.

Zuteck, Michael D.↗

Air bearing apparatus for calibrating force measurement devices

An air bearing for calibrating a force measurement device comprises an inner wall, an outer wall, an upper wall, a lower wall, an internal chamber, an object retention opening, and a plurality of air outlets. The inner wall and outer wall each have a cylindrical shape with the outer wall being concentric with the inner wall. The upper wall and lower wall each have an annular shape and are attached to the inner wall and the outer wall. The internal chamber is formed by inner surfaces of the four walls, and is configured to retain compressed air. The object retention opening is formed by an outer surface of the inner wall and is configured to receive and retain an object. The air outlets are positioned along the inner wall and are configured to allow compressed air to flow from the internal chamber to the object retention opening.

Steuber, Jason↗

Development of novel techniques for non-invasive air leakage and moisture detection in building envelopes

Unwanted air leakage and moisture in building envelopes can cause high energy consumption, detrimental indoor air quality, poor occupant comfort, and reduction in building material durability. High moisture can cause rot and mold, leading to costly and time-consuming repairs that add to the carbon burden of the building envelope. Novel detection techniques for locating and measuring air leakage flow and areas of high moisture in building envelopes will be presented. The techniques are easy, fast, and non-destructive which can enable quick building envelope assessment, foster retrofits, and lead to energy savings and carbon emission reduction.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Passenger cabin air distribution system and method of using

A passenger cabin air distribution system includes a ventilation system and an ejector-diffuser. The ventilation system is operable to provide a conditioned air. The ejector-diffuser is positioned to receive a flow of the conditioned air from the ventilation system. The ejector-diffuser includes an induction unit and a diffuser section. The induction unit includes a secondary inlet in communication with a cabin air from a passenger cabin and is configured to mix the flow of the conditioned air with an induced flow of the cabin air into a mixed air. The diffuser section includes a discharge to eject the mixed air to the passenger cabin. The diffuser section is shaped to provide for efficient mixing with low backpressure in order to maintain the low motive pressure in the nozzle.

42 ENGINEERING↗

Gaseous fuel engine system and operating method for same

Operating a gaseous hydrogen fuel engine includes controlling an injection timing of a gaseous hydrogen fuel injected into a flow of pressurized intake air so as to produce a leading cooling flow of pressurized intake air into a cylinder in an engine, a trailing purging flow through an intake conduit, and a middle flow of both pressurized intake air and gaseous hydrogen fuel into the cylinder. Undesired combustion such as preignition and/or backfire can be limited. Related apparatus and control logic is also disclosed.

Singh, Jaswinder↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Air Quality Changes after Implementation of Mitigation Measures during a Pandemic: A Scoping Review of Literature in the United States

Traffic-related emissions continue to be a significant source of air pollution in the United States (US) and around the globe. Evidence has shown that previous policies implemented to restrict-traffic flows have affected air pollution levels. Thus, mitigation strategies associated with the COVID-19 pandemic that modified population-level mobility patterns provide a unique opportunity to study air pollution change across the US. For instance, to slow the spread of the pandemic, state and local governments started implementing various mitigation actions, including stay-at-home directives, social distancing measures, school closures, and travel restrictions. This scoping review aimed to summarize the existing evidence about how air quality changed through mitigation practices throughout the pandemic in the US. We found 66 articles that fit our inclusion criteria. Generally, the consolidated results revealed that nitrogen dioxide (NO 2 ) and carbon monoxide (CO) decreased across the country. Studies observed mixed directions and magnitudes of change for fine and coarse particulate matter (PM 2.5 , PM 10 ), ozone (O 3 ), and sulfur dioxide (SO2). Few articles tried to explain this notable heterogeneity in air quality changes by associating contextual factors, such as mobility, traffic flow, and demographic factors. However, all studies agreed that the change in air pollution was nonuniform across the US and even varied within a city.

54 ENVIRONMENTAL SCIENCES↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stem CO2 Efflux measurements from Manaus, Brazil, 2017

This data was collected in order to test the effects of temperatures on the autotrophic respiratory process in the tropics. This data package contains raw real-time stem CO2 efflux files during the night and day from 3 different species near the K34 in Manaus during the day and the night. Raw and derived data files are included in the format of .csv and .xlsx and information about the canopy trees and temperatures recorded can be found in the field event log using microsoft excel. The data was collected from three canopy dominant trees in the central Amazon near the K34 tower. Real-time stem CO2 efflux was determined using a Li7000 gas analyzer configured in differential mode and connected to a dynamic stem chamber secured to the stem at breast height using straps to generate a reasonable seal. Ambient air was continuously pumped into the stem chamber and CO2 concentrations of the air entering and exiting the chamber were continuously monitored. CO2 efflux was calculated based on the CO2 concentration difference between ambient and stem chambers, the flow rate of air through the chamber, and the area of the enclosed stem. Additional auxiliary data, including sap flow and crown temperature were also measured. No data processing or QA/QC was done on the raw data packages.

54 ENVIRONMENTAL SCIENCES↗

Direct Air Capture Using Aqueous Amino Acid Solvents in a Crossflow Absorber

Carbon dioxide (CO 2 ) is the most abundant of all greenhouse gases (GHGs). CO 2 levels in the atmosphere are 50% higher than in the preindustrial era, trapping heat. CO 2 removal from the atmosphere by direct air capture (DAC) is needed to achieve the internationally agreed global temperature goals. The most common CO 2 capture technology is absorption by aminebased solvents in packed columns. Amino acid solutions have recently gained attention due to their advantages over traditional amine solvents. To be implemented effectively, DAC industrial processes need to handle large airflow rates in separation absorbers. The large air and solvent flow rates preclude the use of countercurrent columns due to high-pressure drops and the occurrence of flooding. Crossflow air−liquid absorbers are used to handle large air and liquid volumes due to their lower-pressure drop. The objective of this work is to study the influence of crossflow absorber geometric parameters and operating conditions on product formation and process efficiency. An already derived theoretical model for countercurrent absorbers has been modified to simulate the operation of a crossflow DAC absorber. The predictive model was implemented into a computer code that was used to study the efficiency of the processes as geometric equipment dimensions and operating parameters vary. Practical suggestions are made to design more efficient DAC processes.

Absorption↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of the fractal dimension of helium plumes in laminar to turbulent transition

Abstract Schlieren imaging in conjunction with a high-speed camera was used to observe the behavior of metered helium plumes as they transition from laminar to turbulent flow in an air environment. The plumes were visualized at twelve jet Reynolds numbers ranging from 200 to 2980. The fractal dimension of the flows was obtained by applying a box counting algorithm to the recorded schlieren images. The results were analyzed to determine the correlation between the Reynolds number of the flow and the fractal dimension of the observed turbulence. A trend of increasing fractal dimension with increasing Reynolds number was observed for several different types of schlieren cutoffs including horizontal cutoff, vertical cutoff, circular cutoff, focused shadowgraphy and de-focused shadowgraphy. The vertical cutoff and focused shadowgraphy imaging methods showed the most consistent results for the fractal dimension characterization during the laminar to turbulent transition. For transitional plumes, it was observed that fractal dimension increased with distance from the jet outlet.

42 ENGINEERING↗

Modeling and Optimal Design of a Desalination System Integrated Between a Glass-Covered Solar Collection Water Chamber and a Heat Dissipating Chimney

Abstract Solar thermal energy is trapped in a glass-covered water chamber/basin to provide the heat for evaporation of brackish water in a novel desalination system. To harvest clean water, a chimney is integrated with the water basin, which draws air into the chamber to be humidified by the vapor and then being ventilated via buoyance force. Uniquely, thermal conductive metal sheet is recommended to make the chimney, which allows the vapor in the humid air condenses easily when flowing up. The condensate at the inner wall of the chimney flows down to be collected as clean water. Mathematical modeling and numerical computation have been carried out to delineate the coupling of the buoyance-force-driven flow with the heat and mass transfer of air and water in the solar collection chamber and the condensation of vapor in the heat-dissipating chimney. The objective of the simulation and optimization of the system is to find the best match of the dimensions of the water chamber with a chimney to maximize the production of clean water and energy efficiency. The model has been used to simulation several cases (of water from 40 °C to 50 °C) with available experimental data from the authors’ previous work, and the agreement was satisfactory. The optimization studies found that there is a maximum air flowrate corresponding to a critical chimney height due to the requirement that the chimney is designated to dissipate heat as much as possible to condense water vapor. With the chimney height greater than the critical height, the airflow rate will have a slight decrease. Nevertheless, higher than a critical height is still needed for a chimney to condense more moisture. Optimized chamber diameters at different chimney heights are provided for reference of optimal system designs.

Engineering↗