Search NASA⌕ Search

SEARCH · Search NASA

Results for “Arms Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Modal analysis and control of flexible manipulator arms

The possibility of modeling and controlling flexible manipulator arms was examined. A modal approach was used for obtaining the mathematical model and control techniques. The arm model was represented mathematically by a state space description defined in terms of joint angles and mode amplitudes obtained from truncation on the distributed systems, and included the motion of a two link two joint arm. Three basic techniques were used for controlling the system: pole allocation with gains obtained from the rigid system with interjoint feedbacks, Simon-Mitter algorithm for pole allocation, and sensitivity analysis with respect to parameter variations. An improvement in arm bandwidth was obtained. Optimization of some geometric parameters was undertaken to maximize bandwidth for various payload sizes and programmed tasks. The controlled system is examined under constant gains and using the nonlinear model for simulations following a time varying state trajectory.

Neto, O. M.↗

Generalized bilateral control of robot arms

This paper summarizes the theory of a new form of bilateral or force-reflecting manual control of remote robot (slave) arms. The mathematics of workspace representation, command structure, kinematic and dynamic control coordination required for implementing the new form of generalized bilateral control through computer programs is presented. The paper concludes with a brief description of implementation organization of the new system using a six-degree-of-freedom backdrivable hand controller, a PUMA 560 robot arm and a distributed net of microcomputers organized in two groups: one at the remote work site and one at the control station.

Bejczy, A. K.↗

WE-FG-BRA-01: Cancer Treatment Utilizing Photo-Activation of Psoralen with KV X-Rays

Purpose: This work investigates X-PACT (X-ray Psoralen Activated Cancer Therapy): a new approach for the treatment of cancer. X-PACT utilizes psoralen, a potent anti-cancer therapeutic with immunogenic anti-cancer potential. Psoralen therapies have been limited due to the requirement for psoralen activation by UVA light. X-PACT solves this challenge by activating psoralen with UV light emitted from novel non-tethered phosphors (co-incubated with psoralen) that absorb x-rays and reradiate (phosphoresce) at UV wavelengths. Methods: The efficacy of X-PACT was evaluated in both in-vitro and in-vivo settings. In-vitro studies utilized breast (4T1), glioma (CT2A) and sarcoma (KP-B) cell lines. Cells were exposed to X-PACT treatments where the concentrations of drug (psoralen and phosphor) and radiation parameters (energy, dose, and dose rate) were varied. Efficacy was evaluated primarily using flow cell cytometry to investigate treatment induced apoptosis. Methylene blue staining, and WST assays were also used. X-PACT was then evaluated in an in-vivo pilot study on BALBc mice with syngeneic 4T1 tumors, including control arms for X-PACT components. Analysis focused on tumor growth delay. Results: A multivariable regression analysis of 36 independent in-vitro irradiation experiments demonstrated that X-PACT induces significant tumor cell apoptosis and cytotoxicity on all three tumor cell lines in-vitro (p<0.0001). Neither psoralen nor phosphor alone had a strongly significant effect. The in-vivo studies show a pronounced tumor growth delay when compared to controls (42% reduction at 25 days, p=0.0002). Conclusions: These studies demonstrate for the first time a therapeutic effect for X-PACT, and provide a foundation and rationale for future studies. X-PACT represents a novel treatment approach in which well-tolerated low doses of x-ray radiation generate UVA light in-situ (including deep seated lesions) which in-turn photo-activates powerful anticancer therapeutics which may lead to short and long term therapeutic effect. This work was supported by Immunolight Llc.

60 APPLIED LIFE SCIENCES↗

Telepresence work system concepts

Telepresence has been used in the context of the ultimate in remote manipulation where the operator is provided with the sensory feedback and control to perform highly dexterous tasks. The concept of a Telepresence Work Station (TWS) for operation in space is described. System requirements, concepts, and a development approach are discussed. The TWS has the potential for application on the Space Shuttle, on the Orbit Maneuver Vehicle, on an Orbit Transfer Vehicle, and on the Space Station. The TWS function is to perform satellite servicing tasks and construction and assembly operations in the buildup of large spacecraft. The basic concept is a pair of dexterous arms controlled from a remote station by an operation with feedback. It may be evolved through levels of supervisory control to a smart adaptive robotic system.

Jenkins, L. M.↗

Remote inspection of adversary-controlled environments

Remotely monitoring the location and enduring presence of valuable items in adversary-controlled environments presents significant challenges. In this article, we demonstrate a monitoring approach that leverages the gigahertz radio-wave scattering and absorption of a room and its contents, including a set of mirrors with random orientations placed inside, to remotely verify the absence of any disturbance over time. Our technique extends to large physical systems the application of physical unclonable functions for integrity protection. Its main applications are scenarios where parties are mutually distrustful and have privacy and security constraints. Examples range from the verification of nuclear arms-control treaties to the securing of currency, artwork, or data centers.

47 OTHER INSTRUMENTATION↗

A PC-Based Controller for Dextrous Arms

This paper describes the architecture and performance of a PC-based controller for 7-DOF dextrous manipulators. The computing platform is a 486-based personal computer equipped with a bus extender to access the robot Multibus controller, together with a single board computer as the graphical engine, and with a parallel I/O board to interface with a force-torque sensor mounted on the manipulator wrist.

controller PC-Based Controller Dextrous Arms 7-DOF↗

Controlling flexible robot arms using a high speed dynamics process

Described here is a robot controller for a flexible manipulator arm having plural bodies connected at respective movable hinges, and flexible in plural deformation modes. It is operated by computing articulated body qualities for each of the bodies from the respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables. Computing modal deformation accelerations and hinge accelerations is carried out for each of the bodies, beginning with the outermost body by computing a residual body force from a residual body force of a previous body, computing a resultant hinge acceleration from the body force, and then, for each one of the bodies beginning with the innermost body, computing a modal body acceleration from a modal body acceleration of a previous body, computing a modal deformation acceleration and hinge acceleration from the resulting hinge acceleration and from the modal body acceleration.

Jain, Abhinandan↗

Visual Attention Allocation Between Robotic Arm and Environmental Process Control: Validating the STOM Task Switching Model

Fifty six participants time shared a spacecraft environmental control system task with a realistic space robotic arm control task in either a manual or highly automated version. The former could suffer minor failures, whose diagnosis and repair were supported by a decision aid. At the end of the experiment this decision aid unexpectedly failed. We measured visual attention allocation and switching between the two tasks, in each of the eight conditions formed by manual-automated arm X expected-unexpected failure X monitoring- failure management. We also used our multi-attribute task switching model, based on task attributes of priority interest, difficulty and salience that were self-rated by participants, to predict allocation. An un-weighted model based on attributes of difficulty, interest and salience accounted for 96 percent of the task allocation variance across the 8 different conditions. Task difficulty served as an attractor, with more difficult tasks increasing the tendency to stay on task.

STOM attention allocation model validation↗

ONIX: An open-source depletion code

Open Source software enables innovative, community-based software development. ONIX brings this concept to the field of depletion calculations. It is an open-source depletion software to be used for nuclear reactor simulations, for fissile material production analysis as well as for nuclear arms control applications. ONIX provides a module to solve the depletion equation using a Chebyshev Rational Approximation Method. For the generation of one-group cross sections, it includes a coupling interface for the open-source neutron transport code, OpenMC, as well as a module to read pre-computed values in a stand-alone mode. ONIX has special features to optimize nuclear data libraries, to update isomeric branching ratio during burnup, and to support automation of simulations for nuclear archaeology. In conclusion, ONIX has been validated against results from numerical and experimental benchmarks, and its results agree with other methods within expected error ranges.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Information barrier experimental: Toward a trusted and open-source computing platform for nuclear warhead verification

Trusted measurement systems are critical for the verification of future arms-control treaties that involve confirming the authenticity of nuclear warheads on the basis of their radiation signatures. Several research efforts have produced prototype systems, but their designs are typically not published in detail, making it difficult to enable trust in these devices. The Information Barrier Experimental (IBX) is a new prototype built around the Red Pitaya computing platform using passive gamma spectroscopy. It is the first such platform designed to help a broad research community study vulnerabilities and define the required specifications for a common, trusted inspection system. It is low-cost, simple to assemble, and enables comprehensive hardware and software authentication studies. The device follows a digital data acquisition approach, which significantly reduces the number of components between scintillator and spectrum output. Finally, measurements demonstrate that this approach is technically feasible and produces excellent measurement results.

97 MATHEMATICS AND COMPUTING↗

Experimental demonstration and modeling of a robotic neutron detector with spectral and directional sensitivity for treaty verification

International safeguards and arms control agreements often require labor-intensive, intrusive onsite inspections to perform verification tasks. The ability to localize a neutron source and/or characterize a neutron field may be imperative for identifying anomalies. We are interested in the role of autonomous mobile robots, which, if designed properly, may be more effective and efficient and less intrusive than their human counterparts. Toward developing such a capability, we, for this study, have constructed the N-SpecDir Bot, comprised of three boron-coated straw detectors azimuthally-distributed within a cylinder of high-density polyethylene, which is mounted on an omni-directional robotic platform. Our N-SpecDir Bot is specifically designed to provide spectral and directional sensitivity, in addition to gross counts, by utilizing the signals from the three detectors. The detection system has been extensively characterized by MCNP modeling, which has been benchmarked to experiments conducted at the Princeton Plasma Physics Laboratory. We demonstrate the spectral and directional sensitivity experimentally and in simulation, and provide a simple yet robust method for directional measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tools and Incentives for Implementing Codes of Ethics to Help Prevent the Reemergence of Chemical Weapons

Since the entry into force of the Chemical Weapons Convention (CWC) and the establishment of the Organisation for Prohibition of Chemical Weapons (OPCW) in 1997, 96% of the world’s declared stockpile, comprising 72,305 metric tons of chemical warfare agents have been destroyed. Despite this notable progress, the convergence of chemistry and biology brings new challenges to preventing chemical weapons production, as the technical capability to manipulate the chemistry of microorganisms has diffused beyond the chemical industry and academic research communities. The development and voluntary adoption by chemical practitioners around the world of ethical codes or guidelines, such as The Hague Ethical Guidelines and the Global Chemists’ Code of Ethics (GCCE) , are important steps in strengthening international nonproliferation efforts through their potential to impact the intent of the individual by normalizing ethical behavior. However, the simple act of adopting a code does not guarantee ethical behavior. Care must be taken to ensure those adopting the code understand specifically the behavior being asked of them, and they must be given ample opportunities to practice exercising those behaviors in low-risk situations and encouragement to keep trying when they fail. Furthermore, in small-to-medium chemical companies, concerns that adopting such measures could negatively impact profit margins may dissuade some business owners from voluntarily adopting ethical codes, while a country’s decision makers may not prioritize establishment of new regulatory mechanisms that could address some of these concerns. In this paper, factors that may positively influence a chemical company’s decision to adopt ethical guidelines, such as integration of social sustainability elements into frameworks and approaches to maintain social legitimacy in the eyes of the broader community, are explored. Voluntary adoption of ethical codes gives teeth to arms control regimes. By encouraging chemical companies to become engaged in the community around them and providing easy-to-use tools like scenario-based E-learning to enable remote engagement and facilitate understanding of the principles undergirding the GCCE, they actively participate in making the world a better place and minimizing the potential for reemergence of chemical weapons.

Small Chemical Companies, Codes of Ethics, E-learn↗

A physical zero-knowledge object-comparison system for nuclear warhead verification

Zero-knowledge proofs are mathematical cryptographic methods to demonstrate the validity of a claim while providing no further information beyond the claim itself. The possibility of using such proofs to process classified and other sensitive physical data has attracted attention, especially in the field of nuclear arms control. Here we demonstrate a non-electronic fast neutron differential radiography technique using superheated emulsion detectors that can confirm that two objects are identical without revealing their geometry or composition. Such a technique could form the basis of a verification system that could confirm the authenticity of nuclear weapons without sharing any secret design information. More broadly, by demonstrating a physical zero-knowledge proof that can compare physical properties of objects, this experiment opens the door to developing other such secure proof-systems for other applications.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Producing two-dimensional dust clouds and clusters using a movable electrode for complex plasma and fundamental physics experiments

We report a Bidirectional Electrode Control Arm Assembly (BECAA) for precisely manipulating dust clouds levitated above the powered electrode in RF plasmas. The reported techniques allow the creation of perfectly 2D dust layers by eliminating off-plane particles by moving the electrode from outside the plasma chamber without altering the plasma conditions. Here, the tilting and moving of electrodes using BECAA also allows the precise and repeatable elimination of dust particles one by one to achieve any desired number of grains N without trial and error. Simultaneously acquired top and side view images of dust clusters show that they are perfectly planar or 2D. A demonstration of clusters with N = 1–28 without changing the plasma conditions is presented to show the utility of BECAA for complex plasma and statistical physics experimental design. Demonstration videos and 3D printable part files are available for easy reproduction and adaptation of this new method to repeatably produce 2D clusters in existing RF plasma chambers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical cryptographic verification of nuclear warheads

Significance We provide a method for potentially solving one of the central problems in arms control: proving the authenticity of a nuclear warhead without revealing information about its construction. The proposal is the first, to our knowledge, to be proof-theoretically sound (i.e., unspoofable) and information-theoretically secure. The method uses a tomography technique which can resolve the spatial distribution of mass with isotopic specificity. The soundness and security emerge from an integral-geometric transform that is able to uniquely map 3D geometries from zero-dimensional point measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Cryptographic Escrow for Treaty Declarations and Step-by-Step Verification

The verification of arms-control and disarmament agreements requires states to provide declarations, including information on sensitive military sites and assets. There are important cases, however, where negotiations of these agreements are impeded because states are reluctant to provide any such data, because of concerns about prematurely handing over militarily significant information. To address this challenge, we present a cryptographic escrow that allows a state to make a complete declaration of sites and assets at the outset and commit to its content, but only reveal the sensitive information therein sequentially. Combined with an inspection regime, our escrow allows for step-by-step verification of the correctness and completeness of the initial declaration so that the information release and inspections keep pace with parallel diplomatic and political processes. We apply this approach to the possible denuclearization of North Korea. Such approaches can be applied, however, to any agreement requiring the sharing of sensitive information.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Document-Based Nuclear Archaeology

Deeper reductions in the nuclear arsenals will require better understanding of historic fissile material management and production. The concept of “nuclear archaeology” has been considered since the 1990s to provide the tools and methods to develop independent production estimates, primarily based on nuclear forensic techniques. Here, we propose to add a framework for reconstructing the history of a nuclear program that complements traditional nuclear archaeology techniques by examining the role of operating records to support such an effort. As a test case, we use the JEEP II reactor, a 2 MW civilian research reactor at Norway’s Institute for Energy Technology (IFE), in operation for more than fifty years, however, recently shut down permanently. We have collected, analyzed, and started to preserve the reactor’s operating records, which exist on both analog and digital media, and to simulate parts of its history using OpenMC/ONIX neutronics calculations. Here, a particular focus of this project has been on digital data curation and preservation to confirm and maintain the integrity, authenticity, and provenance of these records. In developing guidelines for best practices that conform to existing standards for long-term digital preservation and curation, we hope this project can help lay the basis for future nuclear archaeology efforts to support nuclear arms control and disarmament.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗