Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Multi-Factor-Coupled, Ahead-of-Time Aggregation of Power Flexibility Under Forecast Uncertainty

The increasing penetration of distributed energy resources (DERs) is significantly reshaping the role of distribution systems under active energy management. To aggregate the active-reactive power flexibility of DERs dispersed at the feeder and provide capacity support to the transmission system, it is essential to efficiently identify feasible substation power injection trajectories. This paper introduces a novel ahead-of-time flexibility characterization method to address it. First, a polyhedral non-feeder-level power flexibility region (PFR) is constructed, accounting for various time-dependent, power-coupled, and forecast error uncertainties. Then, a polyhedral feeder-level PFR is analytically derived through a coordinate transformation, which can reveal the uncertainty propagation path, i.e., how uncertainty applies to the feeder-level PFR. To facilitate the high-level application, a tractable chance-constrained Chebyshev centering optimization model is further developed to find a ball-shaped inner approximation of the feeder-level PFR. Finally, the proposed method is validated on a modified IEEE 123-bus test system. Here, both theoretical and experimental results show that, with appropriate robustness parameter settings, the proposed method can make the approximated PFR less conservative with abundant robustness against forecast error uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributionally Robust Bilevel Optimization Model for Distribution Network With Demand Response Under Uncertain Renewables Using Wasserstein Metrics

Here, we consider a distribution network integrating demand response (DR) participants in the presence of uncertain renewable suppliers and outdoor temperatures. A bilevel optimization model is proposed to capture the intricate dynamics between price-incentivized DR participants and distribution system operations, including energy procurement and active/reactive power flows. The model is formulated as a distributional robust bilevel optimization using Wasserstein metrics. We show favorable data-driven properties including out-of-sample guarantee and asymptotic consistency. Furthermore, we present a tractable mixed-integer linear programming reformulation and characterize the worst-case distribution. Computational experiments are conducted on a modified 33-bus system. Our findings underscore the efficacy of the pricing strategies derived from the proposed bilevel optimization model. These strategies not only effectively manage DR participants' behavior but also bring equity considerations among households with various characteristics to light. The results contribute to a deeper understanding of the interplay between distribution system operators and DR participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probability Density Function Control of Frequency Fluctuations in Renewable-Rich Power Systems

The stochastic nature of renewable energy sources (RESs) necessitates treating power system frequency response as a random process with a nonstationary probability density function (PDF). Here, based upon the stochastic distribution control theory originated by the second author, this paper proposes a novel stochastic controller to improve the frequency PDF in power grids when integrating a large amount of RESs, thereby minimizing the effects of uncertainties and enhancing overall system stability. The key idea is to manipulate the controllable power generation resources so that the frequency PDF is make to follow a target PDF by using the stochastic distribution control theory originated by the second author. The proposed method can easily be plugged into existing automatic generation controls for multi-area transmission grids. The proposed method is validated via a modified Kundar's two area system and 240-bus Western Electricity Coordinating Council systems. The simulation results show that the proposed control shapes the frequency PDF narrower and sharper, leading to a notable improvement toward minimizing the effects of randomness and uncertainty during grid operation.

frequency↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generative Vulnerability Assessment for Cyber-Physical Systems

Cyber-physical systems (CPS) are highly susceptible to malicious attacks due to their complex dynamics and interconnectivity. A comprehensive understanding of their vulnerabilities is essential for designing effective resilience measures. This paper presents a data-driven attack generative system for evaluating the vulnerability of CPS. The proposed approach formulates the vulnerability assessment problem as determining the feasibility of a specific attack set based on two boundary functions that represent the effectiveness and stealthiness of attacks. The attack generative model is trained using a custom loss function, with two universal approximators designed to learn the effectiveness and stealthiness functions simultaneously. Theoretical results for successful generation and asymptotic convergence of the resulting training algorithm are given. As a result, the proposed approach is evaluated via numerical simulation of an IEEE 14-bus system and gas pipeline systems, demonstrating its viability in learning how to attack nonlinear CPS and identify potential vulnerabilities.

Computer systems organization↗

Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More than 25,000 h

This study investigates the performance losses and degradation of proton-exchange-membrane fuel-cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 h. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ in- and ex- situ characterization methods such as polarization curves, electrochemical impedance spectroscopy, electron microscopy, and X-ray characterization. Uniform degradation of the catalyst layer including Pt agglomeration/migration and electrode thinning was observed in all of the post-teardown measurements compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of fuel cell vehicle (FCV) powerplants.

25 ENERGY STORAGE↗

CyRRL (Cyber Resilient Reinforcement Learning for grid voltage control) [SWR-24-115]

This codebase contains a multi-agent, actor-critic reinforcement learning implementation for cyber-resilient grid voltage control. It uses a 123-bus OpenDSS system as the environment, with three-phase power flow translating nodal power injections into solved nodal voltages. The reward function penalizes deviations from nominal voltage as well as reactive power dispatch, while encouraging agents to take actions that result in fast convergence to nominal conditions. The codebase models false data injection attacks and includes functionality for training, testing, hyper-parameter tuning, and visualization.

Murphy, Sinnott [National Renewable Energy Laborat↗

Open-Source Ambient-Signal-Based Inertia Monitoring Tool for Power systems [SWR-25-59]

This script, developed by NREL, implements an inertia estimation algorithm using a sliding window approach. The inertia (H) is estimated based on frequency deviations and active power deviations, utilizing the swing equation from power system dynamics. An example application is provided using the WECC 240-bus system.

Peng, Jiangkai [National Renewable Energy Laborato↗

ghostbus v0.1.0

Ghostbus is a Verilog meta-scripting tool which automates memory map creation, address assignment, and bus routing much like Register Description Language (RDL) and SystemRDL, but with a few stark differences. First, the design is entirely defined/captured within the Verilog/SystemVerilog codebase (no extra second language). Second, the Verilog code remains valid even without the auto-generated code, enhancing modularity and compatibility with other tools/workflows.

Huang, Gang [Lawrence Berkeley National Laboratory↗

PowerConverterDynamics.jl

SAND2026-22944O PowerConverterDynamics.jl is a Julia software package for differentiable DC power-conversion dynamics. It models a variable DC source, power converter, common DC bus, and battery module with current, voltage, loss, and state-of-charge dynamics. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

AI4MG-networked-microgrid-models

SF-26-123 24-hour scaled power-flow analysis of a modified IEEE 123-bus distribution feeder using OpenDSS. The simulation runs 24 snapshot power-flow cases (one per hour) with independent hourly scaling profiles for base loads, added loads, generators, and battery storage, and writes per-hour CSV/Excel reports plus a 24-panel voltage-profile plot.

Kumar, Kiran [Argonne National Laboratory (ANL), A↗

An On-Demand Electric Transit Case Study of New Rochelle, New York

Here, this article characterizes the performance and ridership patterns of an on-demand transit (ODT) service utilizing lightweight electric vehicles (EVs) in New Rochelle, New York. Ridership sociodemographics, travel patterns (both temporal and spatiotemporal), and energy use from the service were explored using travel and survey data from September 2019 through December 2023. The ODT service was found to be used more by women (nearly 60%) and younger demographics (>65% under the age of 42), with peak use in the middle of the day and a grocery store as a top origin and destination. The service was utilized primarily for short trips (86% under 2 mi), with approximately one-third of riders using the ODT service to connect to a train or bus. The costs associated with fueling/charging were compared for different types of fleet vehicles, and the small, right-sized EVs were found to have annual charging costs that were roughly half of the refueling costs for conventional hybrid vans, and 24 times lower than a fleet of diesel buses. Evaluating the vehicle fleet and mapping current socio-spatial travel demand can inform system performance, guide service area development, and support future planning such as expansion to nearby communities and transit hubs. The findings in this case study suggest that on-demand electric transit may be a significant and growing space for advancing highly valued public mobility services. Public transport interventions that consider right-sized, electric, on-demand vehicles can help improve mobility access and reduce energy use and refueling costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2000 Southeast Florida Regional Travel Characteristics

The Southeast Florida Regional Travel Characteristics Study (Travel 2000) provided the needed observed travel information for developing planning tools for a three-county region of Southeast Florida (Miami-Dade, Broward, and Palm Beach). Data collection efforts began in December 1998 and were completed in September 1999. Travel logs were collected for 5,168 households, which included all travel by all residents for one day. In addition, approximately 10,000 bus riders were surveyed, and visitors were surveyed at 79 hotels. Trucking information was gathered from 848 commercial establishments using trucks. Workers were surveyed at seven major employment areas in the three counties.

1Hz data↗

Truck Platooning Performance with ADAS and Onboard Camera Data Describing Traffic Interactions

This project was part of the Characterizing Behaviors and Capabilities for Emerging Connected and Automated Vehicle Technologies, Sensors, and Connectivity project. The National Laboratory of the Rockies partnered with Cummins Inc. to collect data from Class 8 tractor trailer combinations in platoon (cooperative adaptive cruise control) operations on public roads in southern Indiana. Data collected include J1939 CAN bus, radar, intervehicle position, and video data. The video data could not be shared in the raw form, so they were processed to extract information on the other vehicles on the road, their relative positions, and intrusion events. This information was then columnized for modeling use and further enhanced by appending road information including road type, speed limit, altitude, and grade. The test route included free-flowing traffic, highway interchanges, and construction zones, as well as low-, medium-, and high-grade sections. Individual test conditions varied by day, with advanced driver-assistance system (ADAS) features engaged or disengaged and different combined vehicle masses tested in addition to uncontrolled variables such as weather and traffic interactions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Onboard/Origin-Destination Survey - Phoenix - 2015

Valley Metro conducted an on-board transit survey during spring 2015. This project gathered updated travel behavior data from transit users that encompassed all rail and bus fixed-route services in the Phoenix metropolitan planning area. The study’s goal was to compile statistically accurate information about transit riders and how they use the transit system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transit Rider/Travel Behavior Inventory Survey - Minneapolis-St. Paul Metro - 2005

The survey was an on-board survey of transit riders on all regular route services for bus and light-rail in the Minneapolis-Saint Paul metropolitan area. The primary purpose of the study was to gather the data needed to update the mode choice models that are an integral component of the regional travel forecast model maintained by the Metropolitan Council, the metropolitan planning organization for the Minneapolis-Saint Paul metropolitan area. The survey instrument focused on identifying characteristics of the trip taken by each transit rider, including origin, destination, trip purpose, and mode of access. The survey also collected relevant socioeconomic and demographic information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transit Rider/Travel Behavior Inventory Survey - Minneapolis-St. Paul Metro - 1990

The 1990 transit on-board survey aimed to update the 1988 survey, which was conducted as part of the Preliminary Engineering Study for the Hennepin County Light Rail Transit System. The 1988 study received Regional Transit Board funding, and survey results could be applied to a mode split model for projecting ridership on the proposed Light Rail Transit System. However, this survey was designed with the 1990 Travel Behavior Inventory in mind. The intention had been to update the 1988 survey in 1990 to be compatible with the 1990 Travel Behavior Inventory data. The results of the 1990 survey were used primarily to create a table of observed transit trips between each of the 1,200 traffic analysis zones in the region. This trip table was used to calibrate a new mode split model, which estimated future year travel by mode. The 1990 update survey focused on new routes and routes that had changed significantly since 1988. To preserve compatibility with the 1988 survey, the same survey questionnaire card was used, together with the same survey procedures for data collection. The procedures randomly sampled bus patrons during the transit trip, asking key questions about the patron and the transit trip. The survey card was intended for patrons to fill out quickly so it could be completed during the transit trip. The questions focused on conditions that have proven over time to significantly influence ridership. In all, a total of 20,126 valid survey records were processed. Adding surrogate trips, the survey data file is composed of a total of 27,159 trip records . About 10% of the records were filled out by persons who had answered more than one questionnaire.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗