Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Modular Heat Engine for the Direct Conversion of Natural Gas to Hydrogen and Power using Hydrogen Turbines (Phase I Final Report)

This report describes a novel, modular heat engine comprising of a one-step hydrogen production from natural gas with in-situ CO 2 separation which is amenable for re-use or sequestration. Combining with a hydrogen turbine subsystem, a distributed or central power generation system is conceived. An added hydrogen storage subsystem enables load-following capability. The techno-economics of the overall system compared favorably against current state-of-the-art natural gas combined cycle plants with post-combustion CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗

A Systematic Approach to Light Load Calculation for DG Un-Intentional Islanding

With the influx of distributed generation (DG) penetration, power utilities have adopted active anti-islanding protection methods to prevent an unintentional islanding condition. One commonly used protection scheme is implemented through the use of a transfer trip from the upline connected substation to the DG facility and is required when the capacity of connected DGs exceed a certain threshold of local minimum load. The threshold established by standard IEEE 1547.2-2009 states that a 3:1 minimum load to generation ratio is acceptable to ensure the DG will not sustain an unintentional island. However, the term “minimum load” is not precisely defined in any standard, and in practice, a light load value is chosen by engineers through manual methods that can be inconsistent, not representative and change drastically based on various cases. To solve this problem, this paper proposes a new light load calculation method creating consistency and better accuracy; the method has been implemented in. NET C# application and is used within Dominion Energy.

Chen, Le↗

Companion Assisted Software Based Remote Attestation in SCADA Networks

Critical infrastructure such as power generation and water distribution systems have become a priority target in cyber warfare because of their recent computerization and introduction to the internet. As a result, Supervisory Control and Data Acquisition (SCADA) system security has become a hot topic in academic and industrial research. Among these topics, Remote Attestation is a security method intended to detect the presence of fileless malware in remote devices as they continue to operate. This allows for the detection of malware in the absence of long-term storage artifacts before symptoms of compromise begin to appear. In general, a trusted device (the verifier) makes a request for evidence of innocence from the untrusted device (the prover). In software-based schemes, the verifier can then measure the delay between its request and the prover’s response. If this delay is greater than the known computational time of the evidence gathering algorithm performed by the prover, then evidence may have been forged. Multi-hop networks often introduce too much network jitter to allow accurate measurement of prover response time, which limits the effectiveness of software based Remote Attestation in a real-world setting. In this work, we introduce a companion device that the verifier can trust to perform a subset of attestation, thereby removing any network jitter. This device is a Field Programmable Gate Array (FPGA) that is physically connected to the prover. We provide a communication protocol between the verifier, prover, and companion. To evaluate our scheme, we simulate it in a common SCADA network environment under normal and heavy traffic loads. Our simulations are performed in the discrete event network simulator NS-3, and we perform statistical analysis over our results to show that our scheme allows for tight timing constraints to be placed on the prover such that the verifier can more easily determine the validity of the evidence that it receives.

Johnson, William A.↗

Industrialized and Robotic Construction Advances in Terrestrial Construction and Opportunities in Space Construction

Advanced Building Construction (ABC) methods such as industrialized prefabrication and robotically controlled additive deposition are becoming promising technologies to support rapid construction of buildings at volume and scale. However, apart from the structural shell of the building, optimal integration of other systems – mechanical, electrical, plumbing, thermal, power generation, storage and distribution, is key to enabling functional buildings. Leveraging ABC methods to integrate such systems in the buildings requires the building design to be optimized for constructability constraints imposed by the industrialized and robotically controlled production setups entailing such ABC methods. The Industrialized Construction Innovation (ICI) team at the National Renewable Energy Laboratory (NREL) has been focusing on research and development of such ABC technologies and processes that can lead to production of buildings which are resilient to extreme climatic conditions at reduced cost and time. There is a potential synergy between such advancements in terrestrial construction, which can be leveraged for the benefit of space (orbital and extra-terrestrial) construction. Similarly, advances in space construction can lend itself to accelerated adoption of robotic construction methods in terrestrial construction. This presentation will give an overview of selective research efforts of the ICI team at NREL, along with a vision for potential collaborations with agencies like NASA.

3D printing↗

An Overview of Inverter-based Resource Interconnection Standards

For the past century, electric power systems have primarily been bulk power systems consisting of generation, transmission, and distribution networks. Now the rapid expansion of distributed renewable power sources (RESs) and the shift from large, conventional synchronous machine resources to smaller-sized resources with diverse generation characteristics become the most significant change in modern power systems. With the increasing penetration of RESs, which are inverter-based resources (IBRs), it is important to develop interconnection standards that define performance and capability criteria for these IBRs. This is necessary to ensure the stable and reliable operation of power systems. This report summarizes the standards for IBRs interconnection in North America.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

Magnetic Pumping as a Source of Particle Heating and Power-Law Distributions in the Solar Wind

Based on the rate of expansion of the solar wind, the plasma should cool rapidly as a function of distance to the Sun. Observations show this is not the case. In this work, a magnetic pumping model is developed as a possible explanation for the heating and the generation of power-law distribution functions observed in the solar wind plasma. Most previous studies in this area focus on the role that the dissipation of turbulent energy on microscopic kinetic scales plays in the overall heating of the plasma. However, with magnetic pumping, particles are energized by the largest-scale turbulent fluctuations, thus bypassing the energy cascade. In contrast to other models, we include the pressure anisotropy term, providing a channel for the large-scale fluctuations to heat the plasma directly. A complete set of coupled differential equations describing the evolution, and energization, of the distribution function are derived, as well as an approximate closed-form solution. Numerical simulations using the VPIC kinetic code are applied to verify the model's analytical predictions. The results of the model for realistic solar wind scenario are computed, where thermal streaming of particles are important for generating a phase shift between the magnetic perturbations and the pressure anisotropy. In turn, averaged over a pump cycle, the phase shift permits mechanical work to be converted directly to heat in the plasma. Here, the results of this scenario show that magnetic pumping may account for a significant portion of the solar wind energization.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Setting the Smart Solar Standard: Collaborations Between Hawaiian Electric and the National Renewable Energy Laboratory

Driving through many neighborhoods of Hawai'i, it is hard to miss the nearly ubiquitous rooftop solar photovoltaic (PV) systems that have popped up during the past eight years or so. Relatively high electricity costs associated with island grids, coupled with various incentives, have made it cost-effective to install solar over the last eight years, as evidenced by the PV-deployment chart in Figure 1. On the most populous island, O'ahu, the PV nameplate acgenerating capacity of 502 MW totals nearly half of the annual peak load for the entire island, which is 1.1 GW . Of that 502 MW of PVs, 54% is from private rooftop solar-nearly 50,000 residences or roughly one of every three single family homes. But Hawaiian Electric, the local utility, has no way to monitor or control the PV generation, even for most nonresidential systems. This means that on sunny days, up to approximately half of the PV generation is outside of the utility's control. This poses many challenges for utility planners and operators-challenges that Hawaiian Electric has been working diligently to address, along with various partners, notably the U.S. Department of Energy (DOE), the National Renewable Energy Laboratory (NREL), and its Energy System's Integration Facility (ESIF). This article describes how Hawaiian Electric has worked with engineers in NREL's Power Systems Engineering Center to improve the way its grid operates with very high levels of distributed PVs, largely by changing the way the PV inverters are operated.

14 SOLAR ENERGY↗

Resilient Distributed Frequency Regulation of Renewable Generators under Communication Interruptions

Modern power systems (MPSs) face significant challenges due to the high penetration of renewable energy sources (RESs) and new types of loads such as electric vehicles (EVs). Traditional load frequency control (LFC) methods struggle with the intermittent, stochastic nature of RESs, the near-zero inertia of power-electronics-based generators, and the mobility of controllable loads and battery systems. This paper introduces a novel resilient distributed frequency regulation method to address these issues. The proposed method employs a state space model to represent the dynamic behavior of participating power sources while accounting for stochastic switching processes to model structural and parameter variations caused by disruptions such as generator connection/disconnection, communication interruptions, and physical faults. By integrating these dynamic and stochastic components, the method treats power grids as a comprehensive stochastic hybrid system. Our method enhances conventional frequency control by incorporating local stability control, neighborhood control decoupling, and coordination feedback. Theoretical analyses establish the stability, convergence, and resilience of the proposed method, and its effectiveness is validated through case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exact Optimal Power Dispatch in Unbalanced Distribution Systems With High PV Penetration

Smart inverters provide additional control capability to help optimize the operation of distribution systems. This paper proposes a framework for exact optimal active and reactive power dispatch of distributed photovoltaic (PV) generation, switched capacitors, and tap changers in large multi-phase unbalanced distribution systems. The objectives of the optimal dispatch are minimization of the energy loss, PV active power curtailment, and capacitor and tap changer switching operations, in addition to elimination of voltage violations and reverse power flow. The optimization problem is formulated in rectangular coordinates as a nonlinear, nonconvex problem. Effective computational strategies are proposed to allow the application of predictorcorrector primal-dual interior point method to solve optimization problems in real-time with a large number of constraints and variables, including discrete variables corresponding to switched capacitors and tap changers. The accuracy of the numerical solution and the ability to implement the proposed framework are validated using the unbalanced multi-phase IEEE 34-bus and EPRI 2,998-bus distribution systems with 15-minute load and PV data. The results show a significant loss reduction and complete removal of both voltage violations and reverse power flow.

Nguyen, Quan (ORCID:0000000347769557)↗

Decentralized Energy Management System for Networked Microgrids in Grid-connected and Islanded Modes

This paper proposes a decentralized energy management system (EMS) for the coordinated operation of networked Microgirds (MGs) in a distribution system. In the grid-connected mode, the distribution network operator (DNO) and each MG are considered as distinct entities with individual objectives to minimize their own operation costs. It is assumed that both dispatchable and renewable energy source (RES)-based distributed generators (DGs) exist in the distribution network and the networked MGs. In order to coordinate the operation of all entities, we apply a decentralized bi-level algorithm to solve the problem with the first level to conduct negotiations among all entities and the second level to update the non-converging penalties. In the islanded mode, the objective of each MG is to maintain a reliable power supply to its customers. In order to take into account the uncertainties of DG outputs and load consumption, we formulate the problems as two-stage stochastic programs. The first stage is to determine base generation setpoints based on the forecasts and the second stage is to adjust the generation outputs based on the realized scenarios. Case studies of a distribution system with networked MGs demonstrate the effectiveness of the proposed methodology in both grid-connected and islanded modes.

Distributed Generator (DG)↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Use of Tidal Power for Enhancing Power System Resilience with Networked Microgrids

The resilience of a power system to withstand a high-impact low-frequency event is a growing concern, especially in coastal communities that tend to be densely populated and very prone to extreme events such as storms and flooding. In such areas, marine renewable energy can be integrated with the existing renewable energy sources to improve generation diversity and power system resiliency. Using networked microgrids as an example, this paper proposes an empirical study to investigate the impact of marine resources, in particular, tidal energy on the power system resiliency. A set of quantitative metrics with intuitive physical interpretations is used to evaluate the resiliency of a power system that is enhanced with distributed generation in the form of rooftop photovoltaic systems and tidal generators. The effectiveness of resource diversification on the power system resiliency is demonstrated through simulations on a model of a real-world coastal distribution feeder located in Sequim, Washington.

Peerzada, Aaqib A.↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗