Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Silicon d-spacing Mapping Measurement System With Resolution of 10{sup -9}

For determination of the Avogadro's number, a self-referenced lattice comparator established at the Photon Factory to deal with a d-spacing mapping measurement over the cross section of a 4 {approx} 5 inches FZ silicon rod. For uncertainty of 1x10{sup -8} of the unit cell volume, it is necessary to measure lattice parameter of silicon with resolution of 3x10{sup -9} at least. In this paper, we report the principle of our lattice comparator, characterize our measurement system, and show some mapping measurement results of FZ silicon with resolution of 3x10{sup -9}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of X-Ray Telescopes for eROSITA and IXO

We report on the development of a generic X-ray instrument simulator to be used in simulations of future X-ray missions. Based on a Monte Carlo approach the code generates photon events for sources in an X-ray source catalogue such as the ROSAT all sky survey or the XMM-Newton slew surveys and then models the imaging and detection process based on the available calibration files (e.g., point spread functions for the imaging). The output of the program are event lists, which can be analysed using standard software such as xselect. Due to its modular concept the simulation software can be easily adapted to different concepts of imaging detectors.As examples for the potential use of the simulation we present our studies for eROSITA and show results of simulations of the detector performance for the High Time Resolution Spectrometer and the Wide Field Imager on the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber Optic Instrumentation in High Temperature Irradiation Environments

The extremely harsh conditions of advanced reactor designs pose serious challenges for nuclear fuels and materials. Traditional instrumentation (thermocouples, strain gauges, etc.) are not well suited for extended operation in such a harsh environment. This work discusses the potential for using fiber optic-based instrumentation in high temperature irradiation experiments. The primary limitation of fiber optic instrumentation in irradiation experiments is signal darkening due to attenuation in the fiber material. A computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Preliminary results obtained using this model are shown for one cycle of irradiation in the high flux isotope reactor at various temperatures. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose in order to validate the predictive model. Demonstration of the safety and reliability of new and enhanced nuclear fuels and materials is essential for improving the safety and reliability of existing nuclear power plants and for the licensing and operation of advanced nuclear reactor technologies. Experimental validation of fuel performance codes requires high fidelity measurements during instrumented irradiation experiments. Therefore, a clear need exists for sensors of unprecedented accuracy, resolution, time/space/energy spectrum dependence, reduced size, and, perhaps most importantly, performance in harsh environments. The harsh environment during accelerated irradiation testing could include temperatures from 300 deg. C up to 2600 deg. C, and radiation damage levels ranging from 1 to greater than 100 dpa. Optical fiber-based sensors are a promising candidate for instrumentation in high temperature irradiation environments. Optical fibers are small, inexpensive, chemically inert, immune to electromagnetic interference, and made of high temperature radiation-hard materials. The ability to make distributed measurements of temperature or strain using a single inexpensive optical fiber currently exists for non-extreme environments as commercially available technology. Other advanced sensing technologies such as laser ultrasound, borescopes, and laser-induced breakdown spectroscopy use fiber optic light delivery as a critical component of the sensor design. Some potential applications for optical fiber-based sensors in instrumented irradiation experiments include in-situ measurements of thermal conductivity, ultrasonic measurement of elastic constants (with fiber optic delivery of signal for generation and detection of ultrasonic wave), and distributed measurements of temperature and/or strain (i.e., swelling). The primary limitation for the use of optical technologies for harsh environment (e.g., high neutron flux reactor environments) instrumentation is the attenuation of the light signal due to the effects of temperature and/or irradiation. This work summarizes initial efforts towards developing a predictive model of temperature-dependent radiation-induced attenuation in fused silica optical fibers at high dose. If there is adequate transmission in the fibers, fiber optic-based instrumentation could provide highly accurate distributed measurements during instrumented fuel/material irradiation experiments. Preliminary results show attenuation on the order of 5- 10 dB/m in the wavelength range of 750-900 nm at temperatures of 300 deg. C and below after one HFIR cycle (24 days). At higher temperatures (600 and 900 deg. C), the attenuation is reduced below 5 dB/m in the same wavelength range. This amount of attenuation is acceptable for most fiber optic based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high flux region. Many optical components use a wavelength of 850 nm, which lies in the low attenuation window. In order to refine and ultimately validate the predictive model of optical fiber attenuation, a reactor irradiation campaign has been initiated. Rabbit irradiation capsules have been designed to irradiate optical fiber material (low and high OH fused silica, as well as single crystal sapphire) specimens in the HFIR at temperatures ranging from 100 to 1200 deg. C. (authors)

42 ENGINEERING↗

Measurement of the target current by inductive probe during laser interaction on terawatt laser system PALS

Measurements of the return-current flowing through a solid target irradiated with the sub-nanosecond kJ-class Prague Asterix Laser System is reported. A new inductive target probe was developed which allows us measuring the target current derivative in a kA/ns range. The dependences of the target current on the laser pulse energy for cooper, graphite, and polyethylene targets are reported. The experiment shows that the target current is proportional to the deposited laser energy and is strongly affected by the shot-to-shot fluctuations. The corresponding maximum target charge exceeded a value of 10 μC. A return-current dependence of the electromagnetic pulse produced by the laser-target interaction is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Intrinsic Fiber Optic Temperature Sensors by In-core and Furnace Testing

Increased research and development in nuclear technology has raised the demand for novel sensors and instrumentation to meet data objectives, and survive in different conditions and environments, beyond conventional light water reactor (LWR) environments. Expediting the deployment of advanced nuclear technologies by developing, demonstrating, and qualifying advanced reactor fuel forms necessitates a deeper understanding of how irradiation affects fuels and materials' performance. To achieve a more comprehensive understanding of fuels and materials performance, researchers require more specialized experiments and measurements. The demand for innovative sensors to support nuclear fuel development arises from the complexity of materials' behavior under irradiation and the challenges of deploying instrumentation in Material Test Reactors (MTRs) for irradiation tests. Additionally, measurements of material properties require integrated measurement systems to characterize thermal properties, mechanical properties, chemistry, and microstructure [1]. Among the potential measurement techniques, optical fiber-based sensors have been identified as potential sensors to measure different physical phenomena such as temperature, strain, pressure, and fluid level. Optical fiber sensors have the capability to provide multi-sensing and multiplexing instrumentation, allowing the measurement of different physical parameters within a single sensor configuration, and transmitting data collected at multiple locations through a single fiber. They offer immunity to electromagnetic interference, electrical passivity, compatibility with various sensing methodologies, and cost-effectiveness. Beyond their widespread use in telecommunications, silica fiber-based instruments are utilized in industrial applications, even at temperatures reaching 300?400°C, such as distributed temperature sensing in oil and gas recovery. The Department of Energy (DOE) is interested in using fiber optics to support fuel cycle development [2]. Fiber optics are an excellent candidate for harsh environment sensing, including sensing at very high temperatures (1900oC for sapphire optical fibers). Distributed fiber optic sensing has been deployed in other harsh environments like coal gasification plants [3]. Distributed strain sensing, which operates similarly to distributed temperature sensing, has been deployed to monitor underground mines and fibers have been imbedded in soil to monitor sink-hole development [4][5]. The application of fiber optic sensors to advanced reactor development is a promising area of research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal configurations of filter cavity in future gravitational-wave detectors

Sensitivity of future laser interferometric gravitational wave detectors can be improved using squeezed light with frequency-dependent squeeze angle and/or amplitude, which can be created using additional so-called filter cavities. Here we compare performances of several variants of this scheme, proposed during the last few years, assuming the case of a single relatively short (tens of meters) filter cavity suitable for implementation already during the life cycle of the second-generation detectors, like Advanced LIGO. Using numerical optimization, we show that the phase filtering scheme proposed by Kimble et al [H. J. Kimble, Yu. Levin, A. B. Matsko, K. S. Thorne, and S. P. Vyatchanin, Phys. Rev. D 65, 022002 (2001).] looks like the best candidate for this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Point matching: A new electronic method for homogenizing the phase characteristics of giant magnetoimpedance sensors

Recently, our research group at PUC-Rio discovered that magnetic transducers based on the impedance phase characteristics of GMI sensors have the potential to multiply by one hundred the sensitivity values when compared to magnitude-based GMI transducers. Those GMI sensors can be employed in the measurement of ultra-weak magnetic fields, which intensities are even lower than the environmental magnetic noise. A traditional solution for cancelling the electromagnetic noise and interference makes use of gradiometric configurations, but the performance is strongly tied to the homogeneity of the sensing elements. This paper presents a new method that uses electronic circuits to modify the equivalent impedance of the GMI samples, aiming at homogenizing their phase characteristics and, consequently, improving the performance of gradiometric configurations based on GMI samples. It is also shown a performance comparison between this new method and another homogenization method previously developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helicity Beam Asymmetry I{center_dot} in Two Neutral Pseudoscalar Photoproduction Reactions at the Crystal Barrel Experiment

A method for measuring the helicity beam asymmetry (I{sub {center_dot}}is shown and demonstrated using the reaction {gamma}p{yields}p{pi}{sup 0{eta}}. The very preliminary results for this channel are presented and suggest that the helicity beam asymmetry is small. The statistics for this channel in this analysis are limited making an analysis of angular dependencies difficult.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Submicrometer Single Crystal Diffractometry for Highly Accurate Structure Determination

Submicrometer single crystal diffractometry for highly accurate structure determination was developed using the extremely stable and highly brilliant synchrotron radiation from SPring-8. This was achieved using a microbeam focusing system and the submicrometer precision low-eccentric goniometer system. We demonstrated the structure analyses with 2x2x2 {mu}m{sup 3} cytidine, 600x600x300 nm{sup 3} BaTiO{sub 3}, and 1x1x1 {mu}m{sup 3} silicon. The observed structure factors of the silicon crystal were in agreement with the structure factors determined by the Pendelloesung method and do not require absorption and extinction corrections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE SOLAR X-RAY CONTINUUM MEASURED BY RESIK

The solar X-ray continuum emission at five wavelengths between 3.495 A and 4.220 A for 19 flares in a 7-month period in 2002-2003 was observed by the RESIK (REntgenovsky Spektrometr s Izognutymi Kristalami) crystal spectrometer on CORONAS-F. In this wavelength region, free-free and free-bound emissions have comparable fluxes. With a pulse-height analyzer having settings close to optimal, the fluorescence background was removed so that RESIK measured true solar continuum in these bands with an uncertainty in the absolute calibration of +-20%. With an isothermal assumption, and temperature and emission measure derived from the ratio of the two GOES channels, the observed continuum emission normalized to an emission measure of 10{sup 48} cm{sup -3} was compared with theoretical continua using the CHIANTI atomic code. The accuracy of the RESIK measurements allows photospheric and coronal abundance sets, important for the free-bound continuum, to be discriminated. It is found that there is agreement to about 25% of the measured continua with those calculated from CHIANTI assuming coronal abundances in which Mg, Si, and Fe abundances are four times photospheric.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for characterizing, synthesizing, and/or canceling out acoustic signals from inanimate sound sources

A system and method for characterizing, synthesizing, and/or canceling out acoustic signals from inanimate sound sources is disclosed. Propagating wave electromagnetic sensors monitor excitation sources in sound producing systems, such as machines, musical instruments, and various other structures. Acoustical output from these sound producing systems is also monitored. From such information, a transfer function characterizing the sound producing system is generated. From the transfer function, acoustical output from the sound producing system may be synthesized or canceled. The methods disclosed enable accurate calculation of matched transfer functions relating specific excitations to specific acoustical outputs. Knowledge of such signals and functions can be used to effect various sound replication, sound source identification, and sound cancellation applications.

47 OTHER INSTRUMENTATION↗

Development of an interpretive simulation tool for the proton radiography technique

Proton radiography is a useful diagnostic of high energy density (HED) plasmas under active theoretical and experimental development. In this paper, we describe a new simulation tool that interacts realistic laser-driven point-like proton sources with three dimensional electromagnetic fields of arbitrary strength and structure and synthesizes the associated high resolution proton radiograph. The present tool’s numerical approach captures all relevant physics effects, including effects related to the formation of caustics. Electromagnetic fields can be imported from particle-in-cell or hydrodynamic codes in a streamlined fashion, and a library of electromagnetic field “primitives” is also provided. This latter capability allows users to add a primitive, modify the field strength, rotate a primitive, and so on, while quickly generating a high resolution radiograph at each step. In this way, our tool enables the user to deconstruct features in a radiograph and interpret them in connection to specific underlying electromagnetic field elements. We show an example application of the tool in connection to experimental observations of the Weibel instability in counterstreaming plasmas, using ∼10{sup 8} particles generated from a realistic laser-driven point-like proton source, imaging fields which cover volumes of ∼10 mm{sup 3}. Insights derived from this application show that the tool can support understanding of HED plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NXIS - Well integrity inspection in unconventional gas wells

The objective of this project is to advance the state-of-the-art and to develop an integrity inspection system capable of detecting physical flaws in the wellbore structure of conventional and unconventional hydrocarbon producing wells. Measuring the integrity of multiple wellbore casings and cement annuli for onshore and offshore wells remains a challenging task. We propose a multi-modality inspection system composed of neutron and X(gamma)-ray imaging modalities (nXis) to address the above challenge. The functional principle of this wellbore integrity inspection system is the combination of high-energy modalities, such as X(gamma)-ray and neutron backscatter imaging, with conventional low-energy modalities, such as electromagnetic or ultrasound imaging techniques. By combining multiple sensing modalities into one sensing system and by fusing data between modalities, one can gather more information about the integrity of the wellbore structure compared to simply using multiple sensors individually. Imaging prototypes for gamma, neutron, and electromagnetics were designed, manufactured, and tested at GE Global Research and Starfire Industries. Wellbore phantoms with engineered defects were manufactured and the performance of the developed wellbore integrity inspection tool prototypes was evaluated in a test pit test at an industrial GE Oil & Gas facility. Data analysis and fusion between various inspection techniques show enhanced defect detectability. These exciting results were presented at various technical conferences and discussed with operators in the oil & gas industry. Great interest from oil operators lead to discussions about joint industrial partnerships to move the developed technology from the prototype phase to the product phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct tests of a pixelated microchannel plate as the active element of a shower maximum detector

One possibility to make a fast and radiation resistant shower maximum detector is to use a secondary emitter as an active element. We report our studies of microchannel plate photomultipliers (MCPs) as the active element of a shower-maximum detector. We present test beam results obtained using Photonis XP85011 to detect secondary particles of an electromagnetic shower. We focus on the use of the multiple pixels on the Photonis MCP in order to find a transverse two-dimensional shower distribution. A spatial resolution of 0.8 mm was obtained with an 8 GeV electron beam. As a result, a method for measuring the arrival time resolution for electromagnetic showers is presented, and we show that time resolution better than 40 ps can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Considerations for Secure Wireless Sensor Communication Systems in Harsh Electromagnetic Environments of Nuclear Reactor Facilities

Wireless sensors can potentially play a significant role in safety, efficiency, and reliability of the instrumentation and control process in current and next generation nuclear power reactors. While conventional narrowband wireless sensors have shown a certain level of success in some nuclear power plants (NPPs), the radio frequency (RF) propagation challenges posed by the heavy metallic and cluttered environment of NPPs has prevented their widespread use in such operations. Furthermore, these challenges include RF wave propagation in harsh (reflective, absorptive, cluttered) environments, data security issues, and RF interference to and from other devices in the vicinity of a nuclear reactor core. In this paper, first we address how ultrawideband (UWB) RF technology can complement the narrowband (i.e., WiFi) solutions that have been used in some NPPs by providing an alternative solution in addressing the signal propagation issues in such electromagnetically harsh environments. Second, we discuss and present the UWB software simulation results on multipath harsh environments, and then address the data security issues. In the final sections of the paper, we present the experimental results of using UWB signaling in a representative harsh environment conducted at the Massachusetts Institute of Technology research reactor site. We plan to develop the UWB communications hardware based on the results of this paper and report on its performance in the field with emphasis on the security aspects of the system in a subsequent paper.

42 ENGINEERING↗

A conceptual design of an electron spectrometer for ELI-NP

We present the geometry and field parameters of an Electron Spectrometer (ES) with two dipole magnets, considered for electron energy measurements at the High Fields QED experimental area at ELI-NP. The first magnet is a 2 meter long permanent magnet, placed inside the Interaction Chamber (IC). The second magnet is a 1.5 meters long electromagnet, placed outside IC. The pulsed electron beam will be produced by the 10 PW pulsed Laser, ‘pump-beam’, focused into one meter long capillary low density plasma cell. A second 10 PW pulsed Laser, ‘probe-beam’, will interact with the relativistic electron bunch providing the strong electromagnetic field. The ES will measure the subtle changes in the electron energy spectrum as a result of the electron beam interaction with the probe-beam field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- η experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The calorimeter system of the new muon g -2 experiment at Fermilab

The electromagnetic calorimeter for the new muon ( g −2) experiment at Fermilab will consist of arrays of PbF 2 Čerenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here the requirements for this system, the achieved solution and the results obtained from a test beam using 2.0–4.5 GeV electrons with a 28-element prototype array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗