A High-resolution Transmission Electron Microscope Study of Fine-grained Phosphates in Metal from the Bishunpur LL3.1 Ordinary Chondrite
No abstract available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
No abstract available
No abstract available
Scanning electron mirrors microscope design and development
The hydrogen embrittlement of aged T-111 and similar Ta and Cb alloys is characterized and the mechanisms believed responsible for the increased sensitivity of T-111 to low temperature hydrogen embrittlement after aging for 1000 hours or longer near 1040 C are described. A total of eight Ta base alloys and two Cb base alloys were investigated. The effects of pre-age annealing temperature, aging time, temperature and environment, and alloy composition on the susceptibility to hydrogen embrittlement were investigated. The primary method of determining the effects of these variables on the ductility of T-111 was by bend testing at 25 and -196 C. Fractured specimens were examined by the scanning electron microscope, electron microprobe, metallography and X-ray diffration.
An attempt is made to characterize the hydrogen embrittlement of aged T-111 and similar Ta and Cb alloys and to describe the mechanisms believed responsible for the increased sensitivity of T-111 to low temperature hydrogen embrittlement after aging for 1000 hr or longer near 1040 C. A total of eight Ta-base alloys and two Cb-base alloys were investigated. The effects of pre-age annealing temperature, aging time, temperature and environment, and alloy composition on the susceptibility to hydrogen embrittlement were investigated. The primary method of determining the effects of these variables on the ductility of T-111 was by bend testing at 25 and -196 C. Fractured specimens were examined by the scanning electron microscope, electron microprobe, metallography, and X-ray diffraction.
Deconvolution algorithm assists in analysis of x-ray spectra from scanning electron microscopes, electron microprobe analyzers, x-ray fluorescence spectrometers, and like. New algorithm automatically deconvolves x-ray spectrum, identifies locations of spectral peaks, and selects chemical elements most likely producing peaks. Technique based on similarities between zero- and second-order terms of Taylor-series expansions of Gaussian distribution and of damped sinusoid. Principal advantage of algorithm: no requirement to adjust weighting factors or other parameters when analyzing general x-ray spectra.
Beam from either cathode electromagnetically aligned with exit port. Electron beam from either of two cathodes deflected by magnetic and electric fields to central axis. Mechanical alignment of beam easy because cathode axes, anode apertures, and electron trajectories coplanar. Applications where uninterrupted service needed: scanning electron microscopes, transmission electron microscopes, electron-beam lithography equipment, Auger instruments, and microfocused x-ray sources.
Ballistic-electron-emission microscope (BEEM) employs scanning tunneling-microscopy (STM) methods for nondestructive, direct electrical investigation of buried interfaces, such as interface between semiconductor and thin metal film. In BEEM, there are at least three electrodes: emitting tip, biasing electrode, and collecting electrode, receiving current crossing interface under investigation. Signal-processing device amplifies electrode signals and converts them into form usable by computer. Produces spatial images of surface by scanning tip; in addition, provides high-resolution images of buried interface under investigation. Spectroscopic information extracted by measuring collecting-electrode current as function of one of interelectrode voltages.
Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.
Electron optical metallographic instruments including electron microprobe X ray analyzer, scanning electron microscope, and transmission electron microscope
The microstructure and properties of rapidly solidified aluminum alloys were researched. The effects of powder and flake chemistry and morphology and alternative consolidation processing parameters are being conducted. Samples of the powders being utilized were obtained for comprehensive metallurgical characterization. Seven aluminum alloys in the form of thin foils were studied by a variety of techniques including optical metallography, scanning electron microscope, and transmission electron microscope. Details of the microstructural characteristics are presented along with a discussion of the solidification process. A better understanding of the microstructure of the rapidly solidified aluminum alloys prepared by a variety of techniques such as roller quenching, the vacuum atomized procedure, ultrasonically atomized in inert atmospheres, and atomized in flue gas was provided.
Fine-grained, spinel-rich Ca-Al-rich inclusions (FGIs) in carbonaceous chondrites, mostly CV3 chondrites, are interpreted as aggregates of nebular gas-solid condensates that escaped significant melting [1]. Multiple lines of evidence suggest a condensation origin for FGIs, including their layered structures and irregular shapes and the fine grain size of numerous spinel-cored nodules [e.g., 2,3], and the distinctive volatility-fractionated group II rare earth element patterns of bulk inclusions and their mineral constituents [e.g., 4,5]. The origin and nature of FGIs are poorly constrained because of their fine grain sizes and intimate intergrowths of refractory phases, combined with their susceptibility to secondary parent body alteration processes, making detailed mineralogical and petrologic characterizations difficult using scanning electron microscope (SEM) and electron microprobe techniques. In this study, we present preliminary transmission electron microscope (TEM) analyses of pristine FGIs from the reduced CV3 chondrite Efremovka in order to provide the detailed characterization of their micrometer- to nanometer-scale textures and chemical compositions. Our goals are to better understand the formation processes and conditions of FGIs in the early solar nebula and to explore their possible genetic relationship with other early-formed refractory inclusions and their rims.
The grape cluster metal particle 63344,1 found in lunar coarse fines is examined using the scanning electron microscope (SEM), electron microprobe, and an optical microscope. This metal particle is approximately 0.5 cm in its largest dimension and consists of hundreds of metallic globules welded together to form a structure somewhat like a bunch of grapes. Electron microprobe analysis for Fe, Ni, Co, P, and S in the metal was carried out using wavelength dispersive detectors. No primary solidification structure is observed in the globules, and the particle is slow cooled from the solidification temperature (nearly 1300 C) taking days to probably months to reach 600 C. Two mechanisms for the formation of globules are proposed. One mechanism involves the primary impact of an iron meteorite which produces a metallic liquid and vapor phase. The second mechanism involves the formation of a liquid pool of metal after impact of an iron meteorite projectile followed by a secondary impact in the liquid metal pool.
Microscopy has been pivotal in improving the understanding of structure-function relationships at the nanoscale and is by now ubiquitous in most characterization labs. However, traditional microscopy operations are still limited largely by a human-centric click-and-go paradigm utilizing vendor-provided software, which limits the scope, utility, efficiency, effectiveness, and at times reproducibility of microscopy experiments. Here, in this work, a coupled software–hardware platform is developed that consists of a software package termed AEcroscopy (short for Automated Experiments in Microscopy), along with a field-programmable-gate-array device with LabView-built customized acquisition scripts, which overcome these limitations and provide the necessary abstractions toward full automation of microscopy platforms. The platform works across multiple vendor devices on scanning probe microscopes and electron microscopes. It enables customized scan trajectories, processing functions that can be triggered locally or remotely on processing servers, user-defined excitation waveforms, standardization of data models, and completely seamless operation through simple Python commands to enable a plethora of microscopy experiments to be performed in a reproducible, automated manner. This platform can be readily coupled with existing machine-learning libraries and simulations, to provide automated decision-making and active theory-experiment optimization to turn microscopes from characterization tools to instruments capable of autonomous model refinement and physics discovery.
Abstract The combined effects of high-temperature and heavy-ion irradiation on Mrozowski cracks (MC) and nuclear graphite crystallographic dimensions have been studied using in situ heating and in situ ion-irradiation in the transmission electron microscope (TEM). Electron transparent lamella of nuclear graphite, IG-110, was irradiated using a 2.8 MeV Au beam at an ion flux of 3.991 ×10 10 ion cm −2 s −1 for 70 min at 800 °C. Upon high-temperature irradiation, Mrozowski crack closure was studied quantitatively. The analysis showed linear, positive expansion of nuclear graphite which is significantly different from the dimensional changes previously reported for low-dose neutron irradiation of nuclear graphite in which the material undergoes negative to positive expansion via a turnaround radiation dose. The trend of the thermal expansion coefficient (CTE) of pristine IG-110 in this study is consistent with previous reports in the 100 °C–800 °C temperature region in which the dimensional change ranges from negative to positive values.
Current concepts of the nature of fatigue failure at low temperatures are presented on the basis of experimental results of various investigators. The fundamental approach to the technique for studying low-temperature fatigue is examined. The necessity for using the same medium at different fatigue test temperatures and also the necessity for taking into account the magnitude of the plastic deformation amplitude are confirmed. Experimental data from a study of the influence of low temperatures (down to liquid nitrogen temperatures) on the fatigue life of copper and armco-iron in dry air, over a wide range of deformations, are presented. These results are compared with microscopic and electron microscopic pictures of the surface of the deformed specimens.
Refractory thin films of Al2O3, ZrO2, MgO, ThO2, and BN have been investigated in situ in an UHV transmission electron microscope. The electron transparent refractory films were prepared by electron-beam evaporation, anodization, RF sputtering, and thinning of bulk crystal materials. The study concentrates on monitoring the thermal and mechanical stability of the films, phase and structural changes, and electron irradiation effects as a function of film-preparation conditions. With increasing temperatures, five different crystallographic phases were observed for both anodized and electron-beam-evaporated alumina films. Zirconia films exhibited two phase transitions upon heating to 1200 C and electron-irradiation-induced crystallization of ZrO2 even at room temperature. MgO, ThO2, and BN films did not undergo any noticeable phase transformation but ruptured due to sintering below 1200 C.