Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

PV Hourly Simulation Tool

This software requires inputs of simple general building characteristics and usage information to calculate the energy and cost benefits of solar PV. This tool conducts and complex hourly simulation of solar PV based primarily on the area available on the rooftop. It uses a simplified efficiency calculation method and real panel characteristics. It includes a detailed rate structure to account for time-of-use rates, on-peak and off-peak pricing, and multiple rate seasons. This tool includes the option for advanced system design inputs if they are known. This tool calculates energy savings, demand reduction, cost savings, incentives and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

Dean, Jesse↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the surface dose contribution of intrafractional kV imaging in CyberKnife-based stereotactic radiosurgery

CyberKnife treatment consists of hundreds of noncoplanar beams and numerous intrafractional images that can be taken during a single treatment fraction; thus, doses because of imaging should be considered in this technique. The aim of this study is to investigate the in-field and out-of-field surface doses induced from kV imaging system during stereotactic radiosurgery (SRS) treatment. The imaging-induced surface doses were measured at the center of the imaging field and within ±15-cm distance from the center in both craniocaudal and lateral directions. TLD100H thermoluminescence dosimeters and EBT2 gafchromic films were used to take the measurements at the locations of 0, ±5, ±10, and ±15 cm in the 2 orthogonal directions on abdominal region of a Rando phantom. The surface dose contributions of imaging system for the 4 most commonly used energy options of 90, 100, 110, and 120 kVp with 3 mAs options of 10, 30, and 90 mAs were measured and compared. Imaging dose values have a positive correlation with both parameters of energy and mAs. The energy options of 100, 110, and 120 kVp, in average, induced 60%, 101%, and 141% more doses per mAs than 90 kVp energy in the imaging field center. A threefold increase in mAs values, i.e., from 10 mAs to 30 mAs and from 30 mAs to 90 mAs, caused higher dose in field center with a factor of 2.53 ± 0.08 when the energy value was kept constant. The in-field dose distributions within ±10 cm in both directions showed a flat pattern with a standard deviation lower than 5%, whereas the out-of-field doses at ±15-cm distance from the field center suddenly dropped to almost half of the central doses. Although a single imaging attempt causes a very low dose compared with the therapeutic dose level, one should be aware of the cumulative surface dose increase with higher imaging number. Proper patient setup, fiducial usage, and reduction of both the mAs values and the imaging numbers should be, therefore, considered to keep the cumulative surface dose in a lower level.

61 RADIATION PROTECTION AND DOSIMETRY↗

COVID-19 pandemic ramifications on residential Smart homes energy use load profiles

The COVID-19 pandemic has significantly affected people’s behavioral patterns and schedules because of stay-at-home orders and a reduction of social interactions. Therefore, the shape of electrical loads associated with residential buildings has also changed. In this paper, we quantify the changes and perform a detailed analysis on how the load shapes have changed, and we make potential recommendations for utilities to handle peak load and demand response. Our analysis incorporates data from before and after the onset of the COVID-19 pandemic, from an Alabama Power Smart Neighborhood with energy-efficient/smart devices, using around 40 advanced metering infrastructure data points. This paper highlights the energy usage pattern changes between weekdays and weekends pre– and post–COVID-19 pandemic times. The weekend usage patterns look similar pre– and post–COVID-19 pandemic, but weekday patterns show significant changes. We also compare energy use of the Smart Neighborhood with a traditional neighborhood to better understand how energy-efficient/smart devices can provide energy savings, especially because of increased work-from-home situations. HVAC and water heating remain the largest consumers of electricity in residential homes, and our findings indicate an even further increase in energy use by these systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GM Light Duty Fuel Cell Electric Vehicle Validation Data

General Motors LLC (GM) completed a multi-phase project with the Department of Energy to validate light-duty fuel cell electric vehicle (FCEV) performance and durability using dynamometer fuel cell system and real-world vehicle performance data. This project began with GM’s Gen 0 Fuel Cell Fleet vehicles with Technology Insertion operating strategies and materials, and extended to GM’s Gen 1 and early Gen 2 commercial-design intent Fuel Cell stacks and Fuel Cell Systems. The intent of this project was to understand how fuel cell materials, system architectures, and operating strategies impact fuel cell stack durability under fully dynamic operating conditions such as those seen in a light duty vehicle application. More than 87,000 hours of system run time were accumulated under this project simulating several vehicle lifetimes under aggressive driver usage conditions. Lessons learned from this demonstration project have helped expedite the development of a commercially viable, zero-petroleum, zero-emission, Fuel Cell propulsion system. Durability test results have enabled a substantial reduction in the precious metal content in the Fuel Cell Stack with each successive generation of stack design. Stack lifetimes between the first and current design iterations have increased nearly tenfold, while the overall precious metal content has been reduced by approximately 85%. The Gen 2 system power density (kW/gPt) is over five times that of the Gen 0 system. In addition, run time voltage degradation as a function of total platinum was reduced by more than an order of magnitude between the first and last phase of this project. GM is proceeding with a low volume production program aided by the results of the durability testing performed under this cooperative agreement.

08 HYDROGEN↗

Discerning structure sensitivity of Ni-core Pd-shell nanoparticles for enhanced nitrite reduction

Denitrification using Pd-based catalysts converts N-oxyanions into harmless products. However, the metal cost and scarcity are barriers to application. In this work, we synthesize water-suspended, structure-controlled Ni-core/Pd-shell nanoparticles (Ni@Pd NPs) that show Pd-catalyzed nitrite (NO 2 − ) reduction catalysis promoted by Ni. The NPs immobilized on Al 2 O 3 (0.47 wt % Pd and 0.74 wt % Ni) have higher NH 4 + selectivity and higher catalytic activity than wet-impregnated Pd/Al 2 O 3 (1.0 wt % Pd), i.e., 315.4 vs. 132.1 Lg surface Pd −1 min −1 . X-ray photoelectron spectroscopy (XPS) and CO-diffuse reflectance infrared Fourier transform spectroscopy (CO-DRIFTS) analyses show that Ni increases Pd electron density, which is proposed to lower the bond dissociation energy barrier for nitric oxide surface intermediate. Low-coordinated Pd atoms correlate to high activity and low NH 4 + selectivity. Using CatCost software, we estimate Ni@Pd/Al 2 O 3 to have a ∼40% lower manufacturing cost compared to wet-impregnated Pd/Al 2 O 3 . This rationally designed catalyst illustrates how nickel promotes Pd catalysis and how Pd usage can be lowered for denitrification and other hydrogenation reactions.

CO-DRIFTS↗

Tuning the Electrocatalytic Oxygen Reduction Reaction Activity of PtCo Nanocrystals by Cobalt Concentration with Atomic-Scale Understanding

The development of a suitable catalyst for the oxygen reduction reaction (ORR) – the cathode reaction of proton exchange membrane fuel cells (PEMFC) – is necessary to push this technology towards widespread adoption. There have been substantial efforts to utilize bimetallic Pt-M alloys that adopt the ordered face-centered tetragonal (L10) phase in order to reduce the usage of precious metal, enhance the ORR performance, and improve catalyst stability. In this work, monodisperse Pt-Co nanocrystals (NCs) with well-defined size (4-5 nm) and cobalt composition (25-75 at%) were synthesized via colloidal synthesis. The transformation from the chemically disordered A1 (face-centered cubic, fcc) to the L10 phase was achieved via thermal annealing using both a conventional oven and a rapid thermal annealing process. The structure of the Pt-Co catalysts was characterized by a variety of techniques, including transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy in high-angle annular dark-field scanning transmission electron microscopy (STEM-EDS), small-angle X-ray scattering (SAXS), X-ray diffraction (XRD), and inductively coupled plasma-optical emission spectrometry (ICP-OES). The effects of annealing temperature on the composition-dependent degree of ordering, and subsequent effect on ORR activity is described. This work provides insights regarding the optimal spatial distribution of elements at the atomic level to achieve enhanced ORR activity and stability.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Energy Efficiency Standards on Natural Gas Prices

A primary justification for the establishment of energy efficiency standards for home appliances is the existence of information deficiencies and externalities in the market for appliances. For example, when a long-term homeowner purchases a new gas-fired water heater, she will maximize the value of her purchase by comparing the life-cycle cost of ownership of available units, including both total installed cost - purchase price plus installation costs - and operating cost in the calculus. Choice of the appliance with the lowest life-cycle costs leads to the most economically efficient balance between capital cost and fuel cost. However, if the purchaser's expected period of ownership is shorter than the useful life of the appliance, or the purchaser does not pay for the fuel used by the appliance, as is often the case with rental property, fuel cost will be external to her costs, biasing her decision toward spending less on fuel efficiency and resulting in the purchase of an appliance with greater than optimal fuel usage. By imposing an efficiency standard on appliances, less efficient appliances are made unavailable, precluding less efficient purchases and reducing fuel usage. The reduction in fuel demanded by residential users affects the total demand for such fuels as natural gas, for example. Reduced demand implies that residential customers are willing to purchase less gas at each price level. That is, the demand curve, labeled D 0 in Figure 1, shifts to the left to D 1 . If there is no change in the supply function, the supply curve will intersect the demand curve at a lower price. Residential demand is only one component of the total demand for natural gas. It is possible that total demand will decline very little if demand in other sectors increases substantially in response to a decline in the price. If demand does decrease, modeling studies generally confirm the intuition that reductions in demand for natural gas will result in reductions in its price as seen at the wellhead (Wiser 2007). The magnitude of the effect on price relative to the demand reduction, and the mechanism through which it occurs, is less well established. This report attempts to quantify the potential effects of reduced demand for natural gas in the residential sector, in response to the implementation of an energy efficiency standard for water heaters.

03 NATURAL GAS↗

Deep Reinforcement Learning Based Smart Water Heater Control for Reducing Electricity Consumption and Carbon Emission

Water heating is the third largest electricity consumer in U.S. households, after space heating and cooling. Thus, water heaters represent a significant potential for reducing electricity consumption and associated CO2 emissions of residential buildings. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity consumption and the CO2 emissions of a heat pump water heater without affecting user comfort. In this approach, a set of RL agents focusing on either electricity saving or emission reduction, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on different hot water usage and Marginal Operating Emissions Rate (MOER) profiles. The testing results showed that the RL agents that focus on electricity saving can save electricity in the range of 12–22% by operating the water heater with maximum heat pump efficiency and minimum electric element utilization. On the other hand, the RL agents that focus on emission reduction reduced emissions in the range of 18–37% by making use of the variable MOER values. These RL agents used the heat pump and/or an element when the MOER values are low due to the availability of renewable energy sources (e.g., solar and wind) and mostly avoided the periods of carbon-intensive periods. Overall, these results showed that the proposed RL approach can help minimize the electricity consumption and the CO2 emissions of a heat pump water heater without having any prior knowledge about the device.

Amasyali, Kadir↗

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

Impacts of the EISA 2007 Energy Efficiency Standard on General Service Lamps

The Energy Policy and Conservation Act of 1975, as amended by the Energy Independence and Security Act of 2007 (EISA 2007), requires that, effective beginning January 1, 2020, the Secretary of Energy shall prohibit the sale of any general service lamp (GSL) that does not meet a minimum efficacy standard of 45 lumens per watt. This is referred to as the EISA 2007 backstop. The U.S. Department of Energy recently revised the definition of the term GSL to include certain lamps that were either previously excluded or not explicitly mentioned in the EISA 2007 definition. For this subset of GSLs, we assess the impacts of the EISA 2007 backstop on national energy consumption, carbon dioxide emissions, and consumer expenditures. To estimate these impacts, we projected the energy use, purchase price, and operating cost of representative lamps purchased during a 30-year analysis period, 2020-2049, for cases in which the EISA 2007 backstop does and does not take effect; the impacts of the backstop are then given by the difference between the two cases. In developing the projection model, we also performed the most comprehensive assessment to date of usage patterns and lifetime distributions for the analyzed lamp types in the United States. There is substantial uncertainty in the estimated impacts, which arises from uncertainty in the speed and extent of the market conversion to solid state lighting technology that would occur in the absence of the EISA 2007 backstop. In our central estimate we find that the EISA 2007 backstop results in significant energy savings of 27 quads and consumer net present value of $120 billion (at a seven percent discount rate) for lamps shipped between 2020 and 2049, and carbon dioxide emissions reduction of 540 million metric tons by 2030 for those GSLs not explicitly included in the EISA 2007 definition of a GSL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of the EISA 2007 Energy Efficiency Standard on General Service Lamps

The Energy Policy and Conservation Act of 1975, as amended by the Energy Independence and Security Act of 2007 (EISA 2007), requires that, effective beginning January 1, 2020, the Secretary of Energy shall prohibit the sale of any general service lamp (GSL) that does not meet a minimum efficacy standard of 45 lumens per watt. This is referred to as the EISA 2007 backstop. The U.S. Department of Energy recently revised the definition of the term GSL to include certain lamps that were either previously excluded or not explicitly mentioned in the EISA 2007 definition. For this subset of GSLs, we assess the impacts of the EISA 2007 backstop on national energy consumption, carbon dioxide emissions, and consumer expenditures. To estimate these impacts, we projected the energy use, purchase price, and operating cost of representative lamps purchased during a 30-year analysis period, 2020-2049, for cases in which the EISA 2007 backstop does and does not take effect; the impacts of the backstop are then given by the difference between the two cases. In developing the projection model, we also performed the most comprehensive assessment to date of usage patterns and lifetime distributions for the analyzed lamp types in the United States. There is substantial uncertainty in the estimated impacts, which arises from uncertainty in the speed and extent of the market conversion to solid state lighting technology that would occur in the absence of the EISA 2007 backstop. In our central estimate we find that the EISA 2007 backstop results in significant energy savings of 27 quads and consumer net present value of $120 billion (at a seven percent discount rate) for lamps shipped between 2020 and 2049, and carbon dioxide emissions reduction of 540 million metric tons by 2030 for those GSLs not explicitly included in the EISA 2007 definition of a GSL.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Orange County Photovoltaic Project & Educational COmponent

The purpose of this report is to discuss the projects implemented, utilizing Department of Energy grant funds, to support the use and understanding of renewable energy in Orange County, Florida and the Greater Orlando Area. Orange County is located in the State of Florida and is most popularly referred to as Orlando. The greater Orlando area’s current population is 1,225,267 and in 2015 was the first destination to surpass 60 million visitors. Orange County utilized grant funds to add to the growing demand for access to charging stations by installing one level 2 dual NovaCharge CT4021 electric vehicle charging station at the Orange County/University of Florida Cooperative Extension Center. The charging station is considered a “smart” charger connected to a central network operated by a third party. Data collected includes the number of charging sessions, session start and end times, the electricity usage, greenhouse gases saved and other pertinent data used for reporting purposes. Orange County continues to support the use of electric vehicles in Metro Orlando and this project continues to bring awareness to our public regarding using alternative vehicles. Additionally, we offer all visitors to the Orange County/University of Florida Cooperative Extension Center free charges for their electric vehicles 24 hours a day. Since the operation of the charging station there have been 52 unique driver users, a total of 532.2258 kg of greenhouse gas savings and 159.03 gallons of gasoline savings. The installation of the additional electric vehicle charging station is part of a county-wide goal of promoting implementation of renewable energy technologies as well as supporting the use of electric vehicles including the Drive Electric Orlando & Florida programs. http://driveelectricorlando.com/ & ; http://www.driveelectricflorida.org/ . Grant funds were also used for Outreach and Educational efforts. Educational efforts about renewable energy were accomplished through the continued support as well as a proposed expansion and potential relocation of the Climate Change Education Center. The growth of the Climate Change Education Center focused on 2 educational subsectors. The first educational sector focused on an apprenticeship with university students. The second sector Orange County partnered with a hospitality college that held seminars to educate students in sustainability best practices that would influence the industry as a whole as students take jobs around the U.S. and other parts of the world. Orange County completed five of the originally proposed six educational seminars. The first seminar focused on community based social marketing techniques for driving sustainable behavior changes. The second seminar held was a green team workshop. The third seminar focused on urban sustainability planning. The fourth and fifth seminars held were Florida Energy Code workshops for building inspectors. A sixth transit oriented development seminar in partnership with Rollins College was explored, but was not conducted because the proposed on campus venue was not accessible for an extended period of time due to renovations. Additionally, an ENERGY STAR training program was conducted with students from the University of Central Florida; three of the five buildings assessed received ENERGY STAR ratings; one student completed the training and received their certification as an ENERGY STAR Specialist. Background: Location: Orange County is located in the central region of the State of Florida and is most popularly known for including the City of Orlando. The greater Orlando area’s current population is 1,225,267 and is home to large corporations such as Walt Disney World, Universal Studios Orlando, Ritz Carlton, Darden Restaurants, and the nation’s second largest convention center. Opportunities Identified: Encouraging Sustainability in Major Sectors: The Central Florida economy is largely dependent on the hospitality industry and in 2015 it was the first destination to surpass 60 million visitors. With over 60 million visitors each year, 120,000 hotel rooms, 4,000 restaurants, and 75 theme parks and attractions, the local hospitality industry provided a wealth of opportunity to reduce greenhouse gas emissions through building energy efficiency and renewable energy. Accordingly, Central Florida is an ideal training ground for teaching best practices for sustainability focused on the hospitality industry. Meeting the Growing Demand for Electric Vehicle Infrastructure: According to the 2014 U.S Clean Tech Leadership Index Report, nationwide electric vehicle ownership in the top 50 largest metro areas increased sharply in 2013; the Orlando Metro Area was ranked #5 in the nation in in terms of electric vehicle charging stations per one million people. Additionally, the Orange County 2014-2015 Annual Sustainable Orange County Report indicated there are 300 electric vehicle charging stations in Central Florida (roughly 300 charging stations within ~70 mile radius available to our residents of Orange County). By increasing and improving access to charging stations, Orange County supports the growing demand for renewable energy technologies. Project Achievements/Accomplishments: Installed an Electric Charging Station: Orange County utilized grant funds to install one level 2 dual NovaCharge CT4021 electric vehicle charging station at the Orange County/University of Florida Cooperative Extension Center. The charging station is considered a “smart” charger connected to a central network operated by a third party that monitors the number of charging sessions, session start and end times, the electricity usage, greenhouse gases saved and other pertinent data. During the six months of operation of the charging station there have been 52 unique driver users of the charging station; a total of 532.2258 kg of greenhouse gas savings and 159.03 gallons of gasoline savings. Operation and Potential Relocation of the Orange County Climate Change Education Center: The Climate Change Education Center, originally located within the Orange County Convention Center, served as a central place to inform and educate commercial and residential sectors of environmental, health, and economic benefits of renewable energy, energy efficiency, and greenhouse gas emission reductions. Grant funds were used to pay for the rent required to maintain a lease at the Convention Center, conduct five educational workshops, and for planned upgrades to the Center displays highlighting a number of energy efficiency and renewable energy projects implemented at the Orange County Convention Center and Downtown Orange County. An initial design concept for an upgraded Climate Change Education Center and educational displays was proposed. However, after the Convention Center determined the space occupied by the Climate Change Education Center; a feasibility study for relocation to the proposed area was conducted in October 2013. In December 2013, it was determined that the desired location of the for the Climate Change Education Center at the Orange County Extension Education Center provided too many construction challenges for relocation with too many building retrofits and access problems, including lack of access for loading and unloading exhibits as well as roof drainage relocations and sewer service connection issues. Another suitable location for relocating the Climate Change Education Center could not be located so the project was terminated. The Climate Change Education Center is no longer in existence in Orange County and has been eliminated. Grant funds were used to pay for marketing services for a state wide marketing program including solar & other renewable energy technologies for rebranding and developing marketing materials including web site design and updating. A website was maintained and updated the www.PowerUpGreenEnergy.com website (no longer in service). Sustainability Training for the Hospitality Industry and Major Sectors: To introduce energy efficiency and renewable energy concepts to the hospitality industry, Orange County partnered with a hospitality college that held seminars to educate students in sustainability best practices that would influence the industry as a whole as students take jobs around the U.S. and other parts of the world. Orange County completed five of the originally proposed six education seminars. Seminar topics included: driving sustainable behavior change through community based social marketing; green team programs; urban sustainability planning; and Florida Energy Code workshops for building inspectors. In partnership with Rollins College, a sixth seminar focused on transit-oriented development was explored, but was not conducted due to extended renovations at the proposed on-campus venue. Green Job Training Development: To promote green industry development and on-the-job training in occupations that encourage energy efficiency and resource reduction, Orange County piloted an ENERGY STAR training and apprenticeship program with students from the University of Central Florida; three students applied for the program; one student completed the training and received their certification as an ENERGY STAR specialist; three of the five buildings assessed received ENERGY STAR Ratings.

14 SOLAR ENERGY↗

Tailoring a Three-Phase Microenvironment for High-Performance Oxygen Reduction Reaction in Proton Exchange Membrane Fuel Cells

Despite tremendous progress in catalyst development for rate-limiting cathodic oxygen reduction reaction (ORR), reducing Pt usage while meeting performance requirements in practical proton exchange membrane fuel cells (PEMFCs) remains a challenge. The ORR in PEMFCs occurs at a catalyst–electrolyte–gas three-phase interface. A desirable interface should exhibit highly active and available catalytic sites, as well as allow efficient oxygen and proton feeding to the catalytic sites and timely removal of water to avoid interface flooding. In this work, we report the design of a three-phase microenvironment in PEFMCs, showing that carbon surface chemistry can be tuned to modulate its interaction with the ionomers and create favorable transport paths for rapid delivery of both reactants and products. With such an elaborate interfacial design, for the first time we have demonstrated PEMFCs with all key ORR catalyst performance metrics, including mass activity, rated power, and durability, surpassing the US Department of Energy targets.

25 ENERGY STORAGE↗

Sustainable Forest Bioenergy Initiative

In the state’s Electricity Restructuring Act of 1998, the Commonwealth of Massachusetts recognized the opportunity and strategic benefits to diversifying its electric generation capacity with renewable energy. Through this legislation, the Commonwealth established one of the nation’s first Renewable Energy Portfolio Standard (RPS) programs, mandating the increasing use of renewable resources in its energy mix. Bioenergy, meeting low emissions and advanced technology standards, was recognized as an eligible renewable energy technology. Stimulated by the state’s RPS program, several project development groups have been looking seriously at building large woody biomass generation units in western Massachusetts to utilize the woody biomass resource. As a direct result of this development, numerous stakeholders have raised concerns and have prompted the state to take a leadership position in pursuing a science based analysis of biomass impacts on forest and carbon emissions, and proceed through a rulemaking process to establish prudent policy to support biomass development which can contribute to the state’s carbon reduction commitments and maintain safeguards for forest sustainability. The Massachusetts Sustainable Forest Bioenergy Initiative (SFBI) was funded by the Department of Energy and started by the Department of Energy Resources before these contentious biomass issues were fully raised in the state, and continued throughout the substantive periods of this policy development. Thereby, while SFBI maintained its focus on the initially proposed Scope of Work, some aspects of this scope were expanded or realigned to meet the needs for groundbreaking research and policy development being advanced by DOER. SFBI provided DOER and the Commonwealth with a foundation of state specific information on biomass technology and the biomass industry and markets, the most comprehensive biomass fuel supply assessment for the region, the economic development impact associated with biomass usage, an understanding of forest management trends including harvesting and fuel processing methods, and the carbon profile of utilizing forest based woody biomass for the emerging biomass markets. Each of the tasks and subtasks have provided an increased level of understanding to support new directives, policies and adaptation of existing regulations within Massachusetts. The project has provided the essential information to allow state policymakers and regulators to address emerging markets, while ensuring forest sustainability and understanding the complex science on CO2 accounting and impacts as a result of biomass harvesting for power generation. The public at large and electricity ratepayers in Massachusetts will all benefit from the information garnered through this project. This is a result of the state’s interest to provide financial incentives to only biomass projects that demonstrate an acceptable carbon profile, an efficient use of the constrained supply of fuel, and the harvest of biomass to ensure forest sustainability. The goals of the Massachusetts Sustainable Forest Bioenergy Initiative as proposed in 2006 were identified as: increase the diversity of the Massachusetts energy mix through biomass; promote economic development in the rural economy through forest industry job creation; help fulfill the state’s energy and climate commitments under the Renewable Energy Portfolio Standard and Climate Protection Plan; assist the development of a biomass fuel supply infrastructure to support energy project demands; provide education and outreach to the public on the benefits and impacts of bioenergy; improve the theory and practice of sustainable forestry in the Commonwealth. Completed project activities summarized below will demonstrate the effectiveness of the project in meeting the above goals. In addition, as discussed above, Massachusetts DOER needed to make some modifications to its work plan and objectives during the term of this project due to changing public policy demands brought forth in the course of the public discourse on this topic. We found that some tasks needed to be adjusted to meet changed conditions. Shortly after the start of SFBI, DOER recognized that establishing demonstration plots within state owned lands was not possible as the state enacted a temporary freeze on all timber harvesting on state lands, to allow for the completion of an assessment of current impacts of this activity and time to develop prudent policies on land conservation. Even more significantly, the state’s energy and environmental Secretary asked DOER to place a “sustainability” criterion for biomass in the RPS regulations, and the passage of the landmark Global Warming Solutions Act in 2008 committed DOER to very carefully consider and assure that biomass energy supported by the RPS met carbon reduction thresholds aligned with the state’s reduction commitments. These needs led to some adjustment of the SFBI scope and objectives to meet the policy challenges. Most notably was the funding and commissioning of the report by the Manomet Center for Conservation Sciences which provided the sustainability and carbon impact framework necessary for DOER to move policy forward prudently. The “Manomet Study” has moved this emerging policy issue substantially forward, gained national and international significance, and provided a new look at how the forest sequesters carbon and the effect of the removal of growing stock for energy on future carbon sequestration and atmospheric flux. This activity provided information that supports the objectives of SFBI but to accommodate this work, several subtasks were combined and addressed within the framework of the Manomet research study. The expected outcomes of the SFBI include the development of biomass energy systems that support sustainable forest management, new investment in forestry and fuel supply infrastructure, biomass energy generation that contributes to greenhouse gas mitigation, and job creation in project development and operation and in the rural forestry sector.

09 BIOMASS FUELS↗

Genome-Scale Modeling of Light-Driven Reductant Partitioning and Carbon Fluxes in Diazotrophic Unicellular Cyanobacterium Cyanothece sp. ATCC 51142

Genome-scale metabolic models have proven useful for answering fundamental questions about metabolic capabilities of a variety of microorganisms, as well as informing their metabolic engineering. However, only a few models are available for oxygenic photosynthetic microorganisms, particularly in cyanobacteria in which photosynthetic and respiratory electron transport chains (ETC) share components. We addressed the complexity of cyanobacterial ETC by developing a genome-scale model for the diazotrophic cyanobacterium, Cyanothece sp. ATCC 51142. The resulting metabolic reconstruction, iCce806, consists of 806 genes associated with 667 metabolic reactions and includes a detailed representation of the ETC and a biomass equation based on experimental measurements. Both computational and experimental approaches were used to investigate light-driven metabolism in Cyanothece sp. ATCC 51142, with a particular focus on reductant production and partitioning within the ETC. The simulation results suggest that growth and metabolic flux distributions are substantially impacted by the relative amounts of light going into the individual photosystems. When photosystem II flux is high, terminal oxidases of respiratory electron transport are predicted to be an important mechanism for removing excess electrons. When photosystem I flux is high cyclic electron transport becomes important. Model predictions of growth rates were in good quantitative agreement with measured growth rates, and predictions of reaction usage were ualitatively consistent with protein and mRNA expression data, when these latter datasets were used to constrain the model.

51142↗

Low-nickel cathode chemistry for sustainable and high-energy lithium-ion batteries

The transition to sustainable energy storage demands lithium-ion batteries with high energy density and reduced reliance on critical metals such as nickel (Ni), yet current strategies to increase capacity have largely depended on raising Ni content, leading to escalating supply risks, rising costs and sustainability concerns. More critically, Ni-rich cathodes suffer from rapid electrochemical degradation driven by structural instability, creating an insurmountable trade-off between capacity and cycle life. Here, in this study, we introduce a low-Ni chemistry cathode, Li(Li 0.05 Ni 0.57 Mn 0.31 Co 0.07 )O 2 , with a radial phase integration design that overcomes these limitations, enabling a remarkable Ni usage reduction (Ni < 0.6) while demonstrating high capacity (215 mAh g −1 ) and markedly improved cyclability (~97% retention over 400 cycles) compared to conventional high-Ni cathodes (Ni = 0.8). Advanced X-ray and electron microscopy analyses reveal that the designed cathode exhibits a highly reversible oxygen anionic redox, benefiting from a structurally stable surface and minimizing irreversible phase transitions. Moreover, the integrated structure substantially mitigates lattice strain and improves mechanical stability even under harsh conditions. In conclusion, this advance offers a general design principle for developing next-generation cathodes that combine resource efficiency with long-term electrochemical reliability.