Search NASASearch

SEARCH · Search NASA

Results for “Fastener Tension Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

262 records · Page 10

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Exploration Extravehicular Mobility Unit 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert Marsch

Exploration Extravehicular Mobility Unit (xEMU) 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert F Marsch

Micromechanics of crenulated fibers in carbon/carbon composites

The influence of crenulated noncircular fibers on the micromechanical stress states due to a transverse strain and to a temperature change in carbon/carbon composites is examined using the finite element method. Stresses at the interface of both fully bonded and fully disbonded fibers having two crenulation amplitudes and with two fiber volume fractions are presented. In each case, these interface stresses are compared to stresses at the interface of circular fibers which have the same degree of disbond and fiber volume fraction and are under the same loading conditions. For the disbonded cases, deformed meshes showing locations of fiber/matrix contact are also included. In addition to the interface stress states, selected composite properties are also computed and compared in each case examined. Interest in studying noncircular fibers stems from a desire to increase the transverse properties of carbon/carbon by introducing a mechanical interlocking between the fiber and the matrix. Results presented here indicate that this interlocking does in fact occur. Evidence from the interface stress data suggests, however, that any possible advantage of this interlocking may be outweighed by the disadvantage of stress concentrations which arise at the interface due to the crenulated geometry of the fibers.

E. E. Carapella

Predicting microstructurally sensitive fatigue‐crack path in WE43 magnesium using high‐fidelity numerical modeling and three‐dimensional experimental characterization

Abstract Microstructurally small fatigue‐crack growth in polycrystalline materials is highly three‐dimensional due to sensitivity to local microstructural features (e.g., grains). One requirement for modeling microstructurally sensitive crack propagation is establishing the criteria that govern crack evolution, including crack deflection. Here, a high‐fidelity finite‐element modeling framework is used to assess the performance and validity of various crack‐growth criteria, including slip‐based metrics (e.g., fatigue‐indicator parameters), as potential criteria for predicting three‐dimensional crack paths in polycrystalline materials. The modeling framework represents cracks as geometrically explicit discontinuities and involves voxel‐based remeshing, mesh‐gradation control, and a crystal‐plasticity constitutive model. The predictions are compared to experimental measurements of WE43 magnesium samples subject to fatigue loading, for which three‐dimensional grain structures and fatigue‐crack surfaces were measured post‐mortem using near‐field high‐energy x‐ray diffraction microscopy and x‐ray computed tomography. Findings from this work are expected to improve the predictive capabilities of simulations involving microstructurally small fatigue‐crack growth in polycrystalline materials.

Engineering

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting

Effectively Considering the Distribution System in Integrated Resource Plans

While electricity planning practices vary by state and utility based on utility type and market structure, integrated resource planning (IRP) remains a prominent vehicle — even in states with centrally-organized wholesale electricity markets. IRP focuses on meeting forecasted long-term electricity needs. Typically, utilities have not considered impacts of design and operation of the low-voltage distribution network in IRP. With advanced capabilities of grid-edge technologies to generate and store electricity and provide load flexibility, and large utility investments in distribution systems, it's increasingly important to consider at least some distribution planning elements in IRP. This report considers the value proposition for doing so, such as reducing utility costs through resource co-optimization and strategic siting of grid-edge resources, and idenfities the most important touchpoints between planning for bulk power and distribution systems and provide a range of tactics for integrating these two processes.

Relf, Grace [Lawrence Berkeley National Laboratory

NASA JSC’s Simulant Development Lab Capabilities and Artemis Testing

The Simulant Development Lab (SDL) is a multifunctional collaborative workspace that supports the development, curation, analysis, testing, and distribution of planetary regolith simulants – including lunar, Martian, asteroidal, and other granular materials. The lab provides a multidisciplinary setting for scientific characterization of simulant physical properties and for engineering evaluations conducted with simulant test beds. To enable this work, the SDL curates and maintains a stock of more than 35 metric tons of simulant material. To evaluate these materials and support testing goals, the lab is equipped with a comprehensive suite of processing tools and analytical instruments. These capabilities enable the SDL’s mission at NASA’s Johnson Space Center to distribute, develop, process, characterize, and test regolith simulants for mission relevant applications. Through controlled and repeatable testing environments that replicate the physical and compositional properties of lunar regolith, the SDL supports Artemis hardware maturation, providing safe, Earth‑based analogs for evaluating systems that must withstand regolith dust interactions, physical wear and abrasion, and operational loads. The facility’s extensive simulant inventory and integrated geological and engineering test infrastructure accelerate technology readiness for Artemis and future exploration campaigns (e.g., future crewed or robotic missions to Mars).

Simulant Development Lab

A thermal evaporation–trapping strategy to synthesize flexible and robust oxygen electrocatalysts for rechargeable zinc–air batteries

Great efforts have been devoted to the development of bifunctional electrocatalysts to accelerate the sluggish kinetics of cathodic oxygen reduction/evolution reactions (ORR/OER) in zinc–air batteries (ZABs). Here we report a thermal evaporation–trapping synergistic strategy to fabricate a bifunctional electrocatalyst of flexible N-doped carbon fiber cloth loaded with both CoFe-oxide nanoparticles and single-atom Co/Fe–Nx sites, in which the thermal evaporation process functions in both downsizing CoFe-oxide nanoparticles and trapping the evaporated Co/Fe species to generate Co/Fe–Nx sites. The obtained flexible electrocatalyst, directly serving as an oxygen electrode, displays a small potential gap of 0.542 V for the OER/ORR, large peak power densities (liquid-state ZAB: 237.4 mW cm2 ; solid-state ZAB: 141.1 mW cm2 ), and excellent charge–discharge cycling stability without decay after working more than 770 hours. Furthermore, in situ Raman spectroscopy characterization and theoretical calculations reveal that CoFe2O4 species is responsible for the OER while atomic Fe/Co sites play a key role in the ORR

Zhang, Hong-Bo

High Velocity Oxygen Fuel Spraying of Erosion and Wear Resistant Coatings on Jet Engine Parts

High velocity oxygen fuel (HVOF) spraying is the most recent development in the field of thermal spraying. The importance of this technique for the repair and new part manufacturing of jet engine parts is rapidly increasing. The HVOF uses a supersonic oxygen-fuel flame to heat and accelerate the powder particles that form the coating. The high particle velocity results in a high density and a low porosity, a high bond strength, and a high macro and micro hardness of the coating. The high quality of the HVOF coatings makes it possible to use these coatings on high loaded, rotating parts in jet engines. This paper will highlight the use of HVOF processes to apply erosion resistant cermet coatings to high pressure compressor blades. These blades are exposed to severe erosion. Next to the D-gun process, HVOF spraying is the only nonproprietary technique that can be used to apply these high performance coatings. Also the use of the HVOF process to apply wear resistant coatings and superalloys to jet engine parts will be discussed. The difference between HVOF coatings and plasma sprayed coatings will be highlighted. During HVOF spraying, the parts are exposed to a high heat flow. Solutions to avoid overheating, especially of titanium parts, will be presented.

A T J Verbeek

Progress on Shape Memory Alloy Actuator Development for Active Clearance Control

Results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine has been conducted. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 in. Design results show that an actuator comprised of 10 wires 2 in. in length is adequate for control at critical engine operating points and still exhibit acceptable failsafe operability and cycle life. A proportional-integral- derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

Jonathan DeCastro

Chapter 12A - Rotorcraft Flight Envelope Unique Considerations

As noted in Section 12, the term flight envelope is used to refer to the boundaries of aircraft loading and flight conditions within which operation of the aircraft is satisfactory, and beyond which some aspect becomes unacceptable. Each aircraft has its own peculiar set of operating conditions and limitations, and this is particularly true of rotorcraft. In addition to the concerns of the fixed wing aircraft test engineer, the helicopter test engineer has to be concerned with dynamic components such as main and tail rotors and their associated control components, transmissions, noise, vibrations, and environmental factors such as swirling particulates which can cause visual obscuration and/or aircraft erosion when operating in unprepared areas like desert, snow, or over salt water. Operation in the hover/low speed regime is a unique capability and is therefore the forte of the helicopter. This "new" regime has its own envelope concerns. This Section provides a brief overview of some of the considerations when establishing/expanding the flight envelope of a rotorcraft. Types of tests and maneuvers, instrumentation, and special considerations will be discussed. However, the reader must be aware that this Section is far from a complete description of all the factors which must be considered in establishing a rotorcraft flight envelope. Much of the material presented in Section 12 is pertinent to rotorcraft envelope definition.

Michael W Mosher

Subscale Hardware-In-The-Loop Results for Hybrid Electric Turbofan Controls Use Cases

NASA is investigating hybrid electric turbine engine systems for commercial transport aircraft due to the potentially significant improvements hybrid electric technology offers in performance, fuel consumption, and operational and design flexibility. Recently, the technology has been tested at full scale in partnership with industry and advanced to Technology Readiness Level 4. This presentation will focus on a recent subscale hardware-in-the-loop test of an open source turbofan engine model developed by NASA. The Advanced Geared Turbofan 30,000 lbf – electrified (AGTF30-e) engine is used as a reference model to demonstrate control system design and use cases for an example mild hybrid electric system with no large-scale energy storage. This model is run in real-time in NASA’s Hybrid Propulsion Emulation Rig (HyPER) and is used to drive an emulation of the turbomachinery system using subscale electric machines. This dynamic scaled shaft emulation interacts with a subscale (<100 kW) hybrid system consisting of electric machines, motor controllers, and a programmable electronic load. Specific use cases demonstrated include the use of Turbine Electrified Energy Management to improve operation during transients, megawatt-scale power extraction from the AGTF30-e, and power transfer between engine spools. Results related to the effectiveness of hybrid systems are qualitatively compared to results from industry testing.

Hybrid

Effect of Barely Visible Impact Damage on Thermoplastic Welded Structure

Spirit Aerosystems recently conducted screening tests on thermoplastic skin/stringer panels manufactured with Automated Fiber Placement (AFP) and stamp forming which were joined using Spirit’s Co-Fusion process. Skin and stringer gauge were both set to 0.168 cm. The resulting panel design is 48 cm tall, 49 cm wide, and has 3 stringers welded at a 21.5 cm pitch. Barely Visible Impact Damage (BVID) and Residual Compressive Strength were chosen to conduct a damage tolerance study. Zee stringers, made with IM8/PEKK-FC material, were Co-Fusion welded to a T1100/TC1225 skin. Out of these 5 panels, 1 was chosen to be a BVID survey panel, 1 for pristine compressive strength determination, and 3 to be impacted to create BVID followed by testing for residual compressive strength. On the survey panel, impacts ranged in energy from 40J – 65J and dent depth measurements were conducted at 24 hours, 48 hours, and two weeks after impacting. The residual compressive strength panel failed near the predicted load of 214 MPa. For the residual compressive strength panels, BVID was created at two different mid-bay locations: 1) striking the OML coincident with the stringer and 2) striking the skin IML 2.5 cm away from the stringer flange. Pulse Echo Ultrasonic Testing was used to inspect the panels before and after creating BVID.

HiCAM

Metal–Organic Framework-derived Atomic Metal Sites Promoting Sulfur Cathode for All-Solid-State Lithium–Sulfur Batteries

All-solid-state lithium–sulfur batteries (ASSLSBs) offer high energy density and intrinsic safety; however, they still face major challenges, including sluggish redox kinetics and poor sulfur utilization. Incorporating conductive materials into sulfur cathodes is an effective strategy to mitigate these limitations. Here, a highly conductive cobalt–nitrogen–doped carbon (Co–NC) derived from a metal–organic framework (MOF) is introduced to accelerate charge transfer and promote reversible sulfur conversion. Co−NC provides atomically dispersed Co–N sites and conductive carbon pathways that correlate with improved charge transfer, sulfur utilization, and rate capability. Co–NC@S cathode delivers 1499 mAh g–1 at C/20 with a high sulfur loading (5 mg cm–2) and retains 1292 mAh g–1 after five cycles (vs 443 mAh g–1 without Co–NC). Moreover, Co–NC derived ASSLSB achieves 903 mAh g–1 at 5C at 60 °C. This work provides a practical and effective approach to develop high energy, high-rate ASSLSBs.

25 ENERGY STORAGE

Advanced Composite Structures and Materials Technologies for Launch Vehicles

The NASA's Advanced Composites Technologies (ACT) Project has the potential to develop composite materials and structures technologies for the largest composite aerospace structures ever made. The objective the ACT Project of is to develop mid-technology readiness level (TRL) composite materials and structures technologies to TRL 6 for specific heavy lift Ares V launch vehicle and Altair lunar lander applications. To accomplish this objective, the ACT Project has four major technical elements: materials and manufacturing; structural concepts development and assessment of lightweight components; testing and evaluation; and highly loaded composite struts. The Project uses capabilities from across NASA to form multi-disciplinary, cross-center teams to meet the milestones of these technical elements. This presentation will describe the activities and plans for the ACT Project. Studies from the first execution year of the project will be summarized including results from materials selection and structural concept evaluation studies. Plans for continuing activities include studies for nondestructive evaluation/structural health monitoring, damage tolerance, joints, and material and structural testing, and these studies will be described. A major emphasis this fiscal year is the start of work for a manufacturing demonstration barrel. This structure will be composed of six, 5-m-diameter, 3-m-long curved panels that when assembled, result in a 10-m-diameter barrel. Activities related to the development of this structure will also be described.

Mark J Shuart

Effect of Thermomechanical Processing on the Microstructure, Properties, and Work Behavior of a Ti50.5 Ni29.5 Pt20 High-Temperature Shape Memory Alloy

TiNiPt shape memory alloys are particularly promising for use as solid state actuators in environments up to 300 °C, due to a reasonable balance of proper ties, including acceptable work output. However, one of the challenges to commercializing a viable high-temperature shape memory alloy (HTSMA) is to establish the appropriate primary and secondary processing techniques for fabrication of the material in a required product form such as rod and wire. Consequently, a Ti 50.5 Ni 29.5 Pt 20 alloy was processed using several techniques including single- pass high-temperature extrusion, multiple-pass high-temperature extrusion, and cold drawing to produce bar stock, thin rod, and fine wire, respectively. The effects of heat treatment on the hardness, grain size, room temperature tensile properties, and transformation temperatures of hot- and cold-worked material were examined. Basic tensile properties as a function of temperature and the strain-temperature response of the alloy under constant load, for the determination of work output, were also investigated for various forms of the Ti 50.5 Ni 29.5 Pt 20 alloy, including fine wire.

Grain Size

Thermostructural Testing of PICA-D for NASA Planetary Science Missions

Phenolic Impregnated Carbon Ablator–Domestic (PICA‑D) has been selected as the heatshield thermal protection system (TPS) material for two upcoming NASA planetary science missions: the Dragonfly mission to Titan and the Mars Sample Retrieval Lander (SRL). Early testing revealed differences between PICA‑D and heritage PICA, particularly in in‑plane (IP) tensile stiffness and thermal expansion. Thermostructural analyses using Finite Element Method (FEM) tools subsequently predicted the potential for IP compressive failure in the near‑surface layers of PICA‑D under both Dragonfly and SRL flight environments. Over the past three years, the Dragonfly and SRL teams have carried out an extensive thermostructural qualification campaign to address these concerns and validate PICA‑D for flight. This effort began with a comprehensive mechanical property characterization program at Kratos test laboratories, which significantly improved understanding of PICA‑D mechanical behavior and increased the fidelity of FEM predictions. The teams also conducted six large‑scale test entries at the National Solar Thermal Test Facility (NSTTF) solar tower, exposing PICA‑D articles—including gap fillers and representative design features or flaws—to combined thermal and mechanical loads. The talk will summarize key findings from these mechanical and thermostructural test campaigns and present the current status of PICA‑D qualification for NASA’s planetary science missions.

TPS