Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Degradation of optical components in a space environment

The objective of the Phillips Laboratory (PL) Long Duration Exposure Facility (LDEF) experiment is to determine the adverse effects of the natural space environment on laser optical component and coating materials. The LDEF experiment provides a unique opportunity for the study of optical material response to an extended low earth orbit space exposure. The PL samples consist of 10 sets of the six materials each. The materials are uncoated fused silica, magnesium fluoride coated fused silica, uncoated molybdenum, molybdenum coated with chromium, silver and thorium fluoride, diamond turned copper, and diamond turned nickel plated copper. Performance degradation will be correlated to establish trends between sample location, duration of exposure, atomic oxygen exposure and other space environmental conditions. This paper discusses the results of the tests thus far performed on the LDEF samples and the plans for the future.

Dehainaut, Linda L.↗

Laser diode array and transmission optics

Information on laser diode array and transmission optics is given in viewgraph form. Information is given on coherent combining of laser diode arrays, amplification through a laser diode array, the far field pattern of a laser diode transmitter, and beam diameter at receiver vs. transmission distance.

Kwon, Jin H.↗

Measurement of structure motion by means of a moving light sheet

The elaboration of an optical system which measures the displacement and velocity of large flexible space structures is reviewed. The motion-measuring system, comprised of a laser, optics, motorized mirror, two photodiodes and electronics, is designed to allow feedback for configuration control of flexible structures. A motor or scanner is employed to sweep the light sheet. The range of motion was shown to be 2 inches, and information was received at a rate of 30 Hz. The uncertainty in displacement measurement was better than +0.01 inch from a distance of 16 feet. The results are considered to be very good for two scanning light sheet systems. Higher sample rates and a more constant speed would improve the rotating mirror option, and the accuracy and range of the scanning mirror option could be upgraded as well. Both setups are shown to be viable noncontact measuring methods for the displacement and velocity of large space structures.

Tcheng, Ping↗

Diamond films for laser hardening

Laser-damage experiments were performed on free-standing polycrystalline diamond films prepared by plasma-enhanced CVD. The high laser-induced stress resistance found for this material makes it useful for thin-film coatings for laser optics. Results for diamond-coated silicon substrates demonstrate the enhanced damage threshold imparted by diamond thin-film coatings to materials susceptible to laser damage.

Albin, S.↗

The Lunar Laser OCTL Terminal (LLOT) Optical Systems

The Lunar Laser OCTL Terminal is an auxiliary ground station terminal for the Lunar Laser Communication Demonstration (LLCD). The LLOT optical systems exercise modulation and beam divergence control over six 10-watt fiber-based laser transmitters at 1568 nanometers, which act as beacons for pointing of the space-based terminal. The LLOT design transmits these beams from distinct sub-apertures of the F/76 OCTL telescope at divergences ranging from 110 microrad to 40 microrad. LLOT also uses the same telescope aperture to receive the downlink signal at 1550 nanometers from the spacecraft terminal. Characteristics and control of the beacon lasers, methods of establishing and maintaining beam alignment, beam zoom system design, co-registration of the transmitted beams and the receive field of view, transmit/receive isolation, and downlink signal manipulation and control are discussed.

laser communications↗

Pressure shift in the 170-micron emission of the CW optically pumped CH3OH laser

Pressure shifts of +15 MHz torr were observed in 16(8)-16(7) 170-micron CW CH3OH optically pumped laser emission. The experiments were performed using a harmonic mixing technique in a Schottky diode. The results are explained in terms of a second-order dipole-dipole interaction in a statistical formulation.

Lawandy, N. M.↗

Single-Event-Upset Laser Scanner With Optical Bias

Light-assisted microelectronic advanced laser scanner (LAMEALS) is augmented version of microelectronic advanced laser scanner (MEALS) described in article, "Laser Scanner Tests For Single-Event Upsets", (NPO-18216). Only major difference, steady illumination from helium/neon laser, argon-ion laser, and/or other source(s) combined with pulsed dye-laser illumination of MEALS into single illuminating beam.

Kim, Quiesup↗

Laser Diagnostics for combustion temperature and species measurements

Laser optical diagnostic techniques for the measurement of combustion gaseous-phase temperatures and, or species concentrations are discussed. The techniques fall into two classes: incoherent (Rayleigh scattering, spontaneous Raman scattering, laser induced fluorescence spectroscopy) and coherent (coherent anti-Stokes Raman spectroscopy). The advantages, disadvantages and applicability of each method are outlined.

Eckbreth, Alan C.↗

Optical superheterodyne receiver uses laser for local oscillator

Optical superheterodyne receiver uses a laser coupled to a frequency translator to supply both the incident signal and local oscillator signal and thus permit reception of amplitude modulated video bandwidth signals through the atmosphere. This receiver is useful in scientific propagation experiments, tracking experiments, and communication experiments.

Lucy, R. F.↗

CubeSat Laser Infrared CrosslinK

The CubeSat Laser Infrared CrosslinK (CLICK) mission will demonstrate technology to advance the state of the art in communications between small spacecraft as well as the capability to gauge their relative distance and location. CLICK is comprised of two sequential missions. The first mission, CLICK A, is a risk reduction mission that will test out elements of the optical (laser) communications with a single 3-unit (3U) spacecraft. The key objective of this risk reduction testing is to demonstrate the fine steering mirror control system's high precision pointing performance which enables the use of a lower power laser in CLICK B/C. The goal of CLICK B/C, the second mission, is to demonstrate full-duplex (send and receive) optical communication crosslink between two 3U small spacecraft, in low-Earth-orbit, at distances between 15 and 360 miles (25 - 580 kilometres) apart at data rates greater than 20 Mbps.

precision ranging↗

Computer simulation of a fringe type laser velocimeter

A computer simulation of a fringe type laser velocimeter has been written to determine the theoretical characteristics of the laser velocimeter when applied to a given flow field. The program includes the effect of particle size and composition on particle lag, light scattering characteristics and signal contrast. The model of the laser velocimeter includes the laser, optical system, photomultiplier, and counter type data processing electronics. The LV particle size analyzer is also modeled and incorporated in the program. An example application of the program to a Mach 5 wind tunnel using a backscatter laser velocimeter is presented.

Meyers, J. F.↗

Hardware cleanliness methodology and certification

Inadequacy of mass loss cleanliness criteria for selection of materials for contamination sensitive uses, and processing of flight hardware for contamination sensitive instruments is discussed. Materials selection for flight hardware is usually based on mass loss (ASTM E-595). However, flight hardware cleanliness (MIL 1246A) is a surface cleanliness assessment. It is possible for materials (e.g. Sil-Pad 2000) to pass ASTM E-595 and fail MIL 1246A class A by orders of magnitude. Conversely, it is possible for small amounts of nonconforming material (Huma-Seal conformal coating) to not present significant cleanliness problems to an optical flight instrument. Effective cleaning (precleaning, precision cleaning, and ultra cleaning) and cleanliness verification are essential for contamination sensitive flight instruments. Polish cleaning of hardware, e.g. vacuum baking for vacuum applications, and storage of clean hardware, e.g. laser optics, is discussed. Silicone materials present special concerns for use in space because of the rapid conversion of the outgassed residues to glass by solar ultraviolet radiation and/or atomic oxygen. Non ozone depleting solvent cleaning and institutional support for cleaning and certification are also discussed.

Harvey, Gale A.↗

Laser probe for measuring 2-D wave slope spectra of ocean capillary waves

A laser-optical instrument for use in determining the two-dimensional wave-slope spectrum of ocean capillary waves is described. The instrument measures up to a 35-deg tip angle of the surface normal by measuring the position of a refracted laser beam directed vertically upward through a water surface. A telescope, a continuous two-dimensional Schottky barrier photodiode, and a pair of analog dividers render the signals independent of water height and insensitive to laser-beam intensity fluctuations. Calibration is performed entirely in the laboratory before field use. Sample records and wave-slope spectra are shown for one-dimensional wave-tank tests and for two-dimensional ocean tests. These are presented along with comparison spectra for calm and choppy water conditions. A mechanical wave follower was used to adjust the instrument position in the presence of large ocean swell and tides.

Palm, C. S.↗

Holographic Optical Storage Using Photorefractive Polymers

The task for this report is to perform the basic research and develop a prototype benchtop holographic optical storage system based on photochromic and/or photorefractive polymers so that both permanent and erasable images may be stored and retrieved in the same mixed polymer medium. The task consist of: assembly and setup of the benchtop holographic storage system, including lasers, optics, and other ancillary equipment in a laboratory setting; and research and development of a suitable polymer matrix that will allow practical storage and retrieval of digital data. This will necessitate molecular design of the matrices involved and subsequent physics test to verify the characteristics of the matrices provide practical storage and retrieval.

Hayden, L. Michael↗

Mid infrared LHS system packaging using flexible waveguides

As mid IR fiber optic systems are rapidly approaching a reality, so is the feasibility of fiber optic laser heterodyne systems. Laser heterodyne spectroscopy for high resolution monitoring of atmospheric gaseous pollutants is necessarily in the mid IR, the region in which the absorption signature of gaseous species is most prominent. It so happens that the lowest theoretical loss due to Rayleigh-Brillouin scattering also lies in the mid IR. Prospects of highly efficient laser heterodyne systems are thus very good. Such fibers are now beginning to be commercially available, and a test program is being conducted for such fibers with ambient temperature ranging from cryogenic to above room, and stringest mechanical flexibility requirements. Preliminary results are encouraging. A program is being started to explore the possibility of mid IR fiber optic device applications, by taking advantage of this phonon rich region. The potential long interaction length in fibers coupled with predicted extremely low losses point to stimulated Brillouin scattering based devices in the mW range. The generation of backscattered sBs at low laser powers is significant not only as an ultimate power limiting factor for laser transmission in fibers in the mid IR, but also the presence of frequency-shifted multiple order sBs Stokes and antiStokes lines will certainly have severe effect on the laser beats crucial in high resolution heterodyne spectroscopy.

Yu, Chung↗

Laser-induced axion photoproduction

Axion photoproduction is suggested as a systematic technique for investigating the coupling of new elementary pseudoscalar or scalar particles in the megaelectronvolt mass range to leptons, photons, and hadronic matter. The experiments involve a configuration where a low-energy photon collides with a relativistic electron beam. Threshold production energies of 300 GeV can be accomplished with an optical laser, and those of 14.5-50 GeV can be achieved with wigglers directed onto an electron beam. With this scheme, at least 10 to the -7th of the electrons can be converted to axions, providing a 1-100 thousand/s relativistic beam of axions.

Brodsky, S. J.↗

An optical motion measuring system for laterally oscillated fatigue tests

This paper describes an optical system developed for materials testing laboratories at NASA Langley Research Center (LaRC) for high resolution monitoring of the transverse displacement and angular rotation of a test specimen installed in an axial-tension bending machine (ATB) during fatigue tests. It consists of a small laser, optics, a motorized mirror, three photodiodes, electronic detection and counting circuits, a data acquisition system, and a personal computer. A 3-inch by 5-inch rectangular plate attached to the upper grip of the test machine serves as a target base for the optical system. The personal computer automates the fatigue test procedure, controls data acquisition, performs data reduction, and provides user displays. The data acquisition system also monitors signals from up to 16 strain gages mounted on the test specimen. The motion measuring system is designed to continuously monitor and correlate the amplitude of the oscillatory motion with the strain gage signals in order to detect the onset of failure of the composite test specimen. A prototype system has been developed and tested which exceeds the design specifications of +/- 0.01 inch displacement accuracy, and +/- 0.25 deg angular accuracy at a sampling rate of 100 samples per second.

Tripp, John S.↗