Performance characterization of a segmented anode arcjet thruster

A modular, 1 to 2 kW class arcjet thruster incorporating a segmented anode/nozzle was operated on a thrust stand to obtain performance characteristics of the device and further study its operating characteristics under a number of experimental conditions. The nozzle was composed of five axial conducting segments isolated from one another by boron nitride spacers. The electrical configuration allowed the current delivered to the arcjet to be collected at any combination of segments. Both the current collected by each segment, and the potential difference between the cathode and each segment were monitored throughout the test period. As in previous tests a similar device, current appeared to attach diffusely in the anode when all of the segments were allowed to conduct. Improvements to the device allowed long term (4 to 8 hour) operation at steady-state and operating characteristics were repeatable over extended periods. Performance characteristics indicated that the segmented anode reasonably simulates the behavior of solid anodes of similar geometry. Current distribution depended on flow rate as the arc attachment moved downstream in the nozzle with increases in the mass flow rate. The current level had little effect on current distribution on the anode segments. Thrust measurements indicated that the current distribution in the nozzle did not significantly affect performance of the device.

Curran, Francis M.↗

Wind Tunnel Testing of Active Flow Control on High-Lift Common Research Model

A 10%-scale high-lift version of the Common Research Model (CRM-HL) and an Active Flow Control (AFC) version of the model equipped with a simple-hinged flap (CRM-SHLAFC) were successfully tested. The tests were performed in the 14- by 22-Foot Subsonic Tunnel (14x22) at the NASA Langley Research Center (LaRC). The CRM-HL has a set of 37° inboard and outboard single-element Fowler flaps. The CRM-SHL-AFC has a set of 50° inboard and 55° outboard simple-hinged flaps equipped with integrated modular AFC cartridges on the flap shoulder. Both high-lift configurations share the same 30° slats and engine nacelle. Three new types of AFC devices were examined: the Double-Row Sweeping Jets (DRSWJ), the Alternating Pulsed Jets (APJ), and the High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used a combination of unsteady and steady jets, to overcome strong adverse pressure gradients while minimizing the mass flow usage. Nozzle pressure ratio, mass flow consumption and the power coefficient, which takes account of both supply air pressure and mass flow usage for the actuators, were used for judging the performance efficiency of the AFC devices. A prestall lift performance degradation for the CRM-HL configuration was resolved with a properly placed nacelle chine. The configuration with nacelle chine was chosen as the representative reference conventional high-lift case for comparison with the CRMSHL- AFC. The AFC-induced lift coefficient increment (DCL) was maintained for the entire lift curve over the CRM-SHL-AFC case with no AFC for almost all flow-control cases examined. The lift curve of the reference CRM-HL have a slightly steeper slope compared to those of the CRM-SHL-AFC configurations. The HELP actuation concept was extremely effective in controlling flow separation in the “linear region” of the curves comparing lift coefficient to mass flow rate. The HELP actuation achieved a targeted DCL of 0.50 using a moderate amount of mass flow and supply air pressure. The CRM-SHL-AFC configuration equipped with HELP actuation was able to match or exceed the lift performance of the reference conventional high-lift configuration (i.e., CRM-HL equipped with a nacelle chine), thus meeting the NASA Advanced Air Transport Technology (AATT) project goal.

Lin, John C.↗

Performance characteristics of two annular dump diffusers using suction-stabilized vortex flow control

The two diffusers employed in the investigation had the same overall area ratio but different prediffuser area ratios and suction slot geometries. Velocity profile and diffuser pressure recovery performance data were obtained at ambient pressure and temperature, with inlet Mach numbers ranging from 0.18 to 0.41 and suction rate varying from zero to 18% of total inlet mass flow rate. On the basis of the reported investigation it is concluded that suction stabilized vortex flow diffusers show promise for application in combustors because of relatively high static pressure recovery and low total pressure loss obtained in a short length. Performance obtained using a narrow angle (7 degree) prediffuser was superior to that obtained with a prediffuser having a 14 degree included angle.

Juhasz, A. J.↗

Qualitative responses of a vortex core to tip blowing and intersecting airfoils

The qualitative responses of a trailing vortex core to change in its convective velocity produced by injection of air into the vortex core and by the flow field of a lifting surface in the path of the core are discussed. Flow pictures of the vortex core and vorticity measurements in the core show that an axial momentum injection of approximately 35% of the total wing drag alters the vortex structure and behavior quite drastically by effectively inducing a more rapid dispersion of the vorticity in the core. The data indicate that the phenomenon is governed by the rate of injection of the momentum rather than the mass flow rate. There also seems to be an optimum rate of injection beyond which increased injection does not bring about equally significant changes in the vortex core. Flow patterns of the region of interaction between the flow field of a lifting surface and the vortex core show two modes of vortex response; (1) the vortex core bends, following the streamline shape until it intercepts the wake of the wing where it is abruptly dispersed, or (2) the vortex core may be sliced into two similar vortices when the vortex hits the leading edge of the wing.

Kantha, H. L.↗

H2OTSTUF: Appropriate Operating Regimes for Magnetohydrodynamic Augmentation

A trade study of magnetohydrodynamic (MHD) augmented propulsion reveals a unique operating regime at lower thrust levels. Substantial mass savings are realized over conventional chemical, solar, and electrical propulsion concepts when MHD augmentation is used to obtain optimal I(sub sp). However, trip times for the most conservative estimates of power plant specific impulse and accelerator efficiency may be prohibitively long. Quasi-one-dimensional calculations show that a solar or nuclear thermal system augmented by MHD can provide competitive performance while utilizing a diverse range of propellants including water, which is available from the Space Shuttle, the Moon, asteroids, and various moons and planets within our solar system. The use of in-situ propellants will reduce costs of space operations as well as enable human exploration of our Solar System. The following conclusions can be drawn from the results of the mission trade study: (1) There exists a maximum thrust or mass flow rate above which MHD augmentation increases the initial mass in low earth orbit (LEO); (2) Mass saving of over 50% can be realized for unique combination of solar/MHD systems; (3) Trip times for systems utilizing current power supply technology may be prohibitively long. Theoretical predictions of MHD performance for in space propulsion systems show that improved efficiencies can reduce trip times to acceptable levels; (4) Long trip times indicative of low thrust systems can be shortened by an increase in the MHD accelerator efficiency or a decrease in the specific mass of the power supply and power processing unit; and (5) As for all propulsion concepts, missions with larger (Delta)v's benefit more from the increased specific impulse resulting from MHD augmentation. Using a quasi-one-dimensional analysis, the required operating conditions for a MHD accelerator to reach acceptable efficiencies are outlined. This analysis shows that substantial non-equilibrium ionization is desirable.

Jones, Jonathan E.↗

Mass, momentum and energy flow from an MPD accelerator

The mass, momentum, and energy flows are measured over a current range of 8 to 50 kA and inlet mass flows of 2 to 36q/sec of argon. The momentum flux profile indicates that the accelerator produces a uniform, 2-inch diameter axial jet at the anode which expands into a Gaussian profile at an axial station 11 inches from the anode. The electromagnetic component of the thrust is found to follow the familiar quadratic dependence on arc current, while a more complex empirical relation is needed to correlate the gasdynamic contribution with the current and mass flow rate. Using available time-of-flight velocity profiles at a current of 16 kA and a mass flow of 5.9 g/sec, calculated flux profiles of mass and kinetic energy exhibit a tendency for some fraction of the inlet mass flow to leak out at a low velocity around the central high velocity core.

Cory, J. S.↗

Co-Flow Hollow Cathode Technology

Hall thrusters utilize identical hollow cathode technology as ion thrusters, yet must operate at much higher mass flow rates in order to efficiently couple to the bulk plasma discharge. Higher flow rates are necessary in order to provide enough neutral collisions to transport electrons across magnetic fields so that they can reach the discharge. This higher flow rate, however, has potential life-limiting implications for the operation of the cathode. A solution to the problem involves splitting the mass flow into the hollow cathode into two streams, the internal and external flows. The internal flow is fixed and set such that the neutral pressure in the cathode allows for a high utilization of the emitter surface area. The external flow is variable depending on the flow rate through the anode of the Hall thruster, but also has a minimum in order to suppress high-energy ion generation. In the co-flow hollow cathode, the cathode assembly is mounted on thruster centerline, inside the inner magnetic core of the thruster. An annular gas plenum is placed at the base of the cathode and propellant is fed throughout to produce an azimuthally symmetric flow of gas that evenly expands around the cathode keeper. This configuration maximizes propellant utilization and is not subject to erosion processes. External gas feeds have been considered in the past for ion thruster applications, but usually in the context of eliminating high energy ion production. This approach is adapted specifically for the Hall thruster and exploits the geometry of a Hall thruster to feed and focus the external flow without introducing significant new complexity to the thruster design.

Hofer, Richard R.↗

Leak Tester for Cryogenic Flowlines

Gas chromatography measures leakage into cavity surrounding joint under test. System surrounds joint being tested with sealed cavity. Presence of leakage gas in cavity monitored by gas chromatograph. Leakage rate found by multiplying relative leakage gas concentration by mass flow rate of purge as into cavity.

Mortensen, G. D.↗

Development of a Small Area Sniffer

The aim of this project is to develop and implement a sniffer that is capable of measuring the mass flow rate of air through a small area of pinholes whose diameters are on the magnitude of thousandths of an inch. The sniffer is used to scan a strip of a leading edge panel, which is being used in a hybrid laminar flow control experiment, in order to survey the variations in the amount of air that passes through the porous surface at different locations. Spanwise scans are taken at different chord locations by increasing the pressure in a control volume that is connected to the sniffer head, and recording the drop in pressure as the air is allowed to flow through the tiny holes. This information is used to obtain the mass flow through the structure. More importantly, the deviations from the mean flow rate are found and used to determine whether there are any significant variations in the flow rate from one area to the next. The preliminary results show little deviation in the spanwise direction. These results are important when dealing with the location and amount of suction that will be applied to the leading edge in the active laminar flow control experiment.

Meade, Laurie A.↗

Performance of a vortex-controlled diffuser in an annular swirl-can combustor at inlet Mach numbers up to 0.53

A short, annular dump diffuser with suction stabilized vortices in the region of abrupt area change was tested with a full scale, annular swirl can combustor. The prediffuser area ratio was 1.4. Performance data were obtained for both isothermal and burning conditions at inlet temperatures of 589 to 895 K and pressures of 0.5 to 1.0 MPa for a range of diffuser inlet Mach numbers from 0.25 to 0.53. Suction rates were 0 to 20 percent of the total diffuser mass flow rate. Diffuser effectiveness increased from 47 percent without suction to approximately 80 percent for a total suction rate of 14 percent. Combustor total pressure loss for the same total suction rate was reduced from 6.8 percent without suction to 4.0 percent at an inlet Mach number of 0.40.

Smith, J. M.↗

Analysis of an initial lunar outpost life support system preliminary design

A preliminary design of a life-support system (LSS) was developed as part of an ongoing comprehensive trade study of advanced processor technologies and system architectures for an initial lunar outpost. The design is based on a mission scenario requiring intermittent occupation of a lunar-surface habitat by a crew of four. It incorporates physiochemical process technologies that were considered for Space Station Freedom. A system-level simulation model of the design was developed to obtain steady-state material balances for each LSS processor. The mass-flow rate predictions were used to obtain estimates of the LSS mass, volume, and power consumption by means of processor-sizing correlations that were extrapolated from Space Station Freedom processor designs. The results were used to analyze the impacts of varying crew size, mission duration, processor-operation strategy, and crew-cabin loads on the LSS mass, average power consumption, volume, periodic resupply mass, and waste-accumulation rates. The merits of the design were quantified relative to an open-loop LSS, and the implications of this assessment for future LSS research and technology development were identified.

Ballin, Mark G.↗

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Liquid Acquisition Device↗

Integrated fountain effect pump device for fluid management at low gravity

A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.

Yuan, S. W. K.↗

Development of a 13 kW Hall Thruster Propulsion System Performance Model for AEPS

The Advanced Electric Propulsion System (AEPS) program will develop a flight 13kW Hall thruster propulsion system based on NASA's HERMeS thruster. The AEPS system includes the Hall Thruster, the Power Processing Unit (PPU) and the Xenon Flow Controller (XFC). These three primary components must operate together to ensure that the system generates the required combinations of thrust and specific impulse at the required system efficiencies for the desired system lifetime. At the highest level, the AEPS system will be integrated into the spacecraft and will receive power, propellant, and commands from the spacecraft. Power and propellant flow rates will be determined by the throttle set points commanded by the spacecraft. Within the system, the major control loop is between the mass flow rate and thruster current, with time-dependencies required to handle all expected transients, and additional, much slower interactions between the thruster and cathode temperatures, flow controller and PPU. The internal system interactions generally occur on shorter timescales than the spacecraft interactions, though certain failure modes may require rapid responses from the spacecraft. The AEPS system performance model is designed to account for all these interactions in a way that allows evaluation of the sensitivity of the system to expected changes over the planned mission as well as to assess the impacts of normal component and assembly variability during the production phase of the program. This effort describes the plan for the system performance model development, correlation to NASA test data, and how the model will be used to evaluate the critical internal and external interactions. The results will ensure the component requirements do not unnecessarily drive the system cost or overly constrain the development program. Finally, the model will be available to quickly troubleshoot any future unforeseen development challenges.

Stanley, Steven↗

Self-Consistent Implementation of a Zero-Equation Transport Model Into a Predictive Model for a Hall Effect Thruster

The performance of an axisymmetric multi-fluid Hall thruster code that incorporates a self-consistent, data-driven closure model for the anomalous electron transport is investigated. Five different operating conditions of the H9 magnetically shielded Hall thruster are simulated with the Jet Propulsion Laboratory’s Hall2De. In order to capture the inherent uncertainty associated with the closure model, O(100) simulations are run for each condition, each of using a coefficient set sampled randomly from a probability distribution. The results of these simulations provide probabilistic predictions of thruster performance quantities including thrust, and discharge current, as well as several component efficiencies and centerline plasma properties. The model is found to yield converged solutions at all conditions, with large 10 kHzrange oscillations and performance trends with voltage and flow rate similar to experiment. The model under-predicts the thrust by 15-25% and over-predicts the discharge current by 20% on average compared to experiments at the same discharge voltage and mass flow rate. This performance discrepancy is due to lower beam utilization, mass utilization, and divergence efficiency than experiment, resulting from high Hall parameters in the acceleration region, which lead to a protracted ion acceleration region. The physical processes underlying this result are discussed in the context of future data-driven modeling efforts.

Jorns, Benjamin A.↗

Arcjet load characteristics

Experiments were conducted to define the interface characteristics and constraints of 1 kW class arcjets run on simulated decomposition products of hydrazine and power processors. The impacts of power supply output current ripple on arcjet performance were assessed by variation of the ripple frequency from 100 Hz to 100 kHz with 10 percent peak-to-peak ripple amplitude at 1.2 kW. Ripple had no significant effects on thrust, specific impulse or efficiency. The impact of output ripple on thruster lifetime was not assessed. The static and dynamic impedances of the arcjet were quantified with two thrusters of nearly identical configuration. Superposition of an AC component on the DC arc current was used to characterize the dynamic impedance as a function of flow rate and DC current level. A mathematical model was formulated from these data. Both the static and dynamic impedance magnitude were found to be dependent on mass flow rate. The amplitude of the AC component was found to have little effect on the dynamic impedance. Reducing the DC level from 10 to 8 amps led to a large change in the magnitude of the dynamic impedance with no observable phase change. The impedance data compared favorably between the two thrusters.

Hamley, John A.↗

Arcjet load characteristics

Experiments were conducted to define the interface characteristics and constraints of 1 kW class arcjets run on simulated decomposition products of hydrazine and power processors. The impacts of power supply output current ripple on arcjet performance were assessed by variation of the ripple frequency from 100 Hz to 100 kHz with 10 percent peak-to-peak ripple amplitude at 1.2 kW. Ripple had no significant effects on thrust, specific impulse or efficiency. The impact of output ripple on thruster lifetime was not assessed. The static and dynamic impedances of the arcjet were quantitied with two thrusters of nearly identical configuration. Superposition of an AC component on the DC arc current was used to characterize the dynamic impedance as a function of flow rate and DC current level. A mathematical model was formulated from these data. Both the static and dynamic impedance magnitude were found to be dependent on mass flow rate. The amplitude of the AC component was found to have little effect on the dynamic impedance. Reducing the DC level from 10 to 8 amps led to a large change in the magnitude of the dynamic impedance with no observable phase change. The impedance data compared favorably between the two thrusters.

Hamley, John A.↗

Low-Current, Xenon Orificed Hollow Cathode Performance for In-Space Applications

An experimental investigation of the operating characteristics of 3.2-mm diameter orificed hollow cathodes was conducted to examine low current and low flow rate operation. Cathode power was minimized with an orifice aspect ratio of approximately one and the use of an enclosed keeper. Cathode flow rate requirements were proportional to orifice diameter and the inverse of the orifice length. The minimum power consumption in diode mode was 10-W, and the minimum mass flow rate required for spot-mode emission was approximately 0.08-mg/s. Cathode temperature profiles were obtained using an imaging radiometer and conduction was found to be the dominant heat transfer mechanism from the cathode tube. Orifice plate temperatures were found to be weakly dependent upon the flow rate and strongly dependent upon the current.

Domonkos, Matthew T.↗