Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Infrared imaging of Jupiter in the 8-14-micrometer spectral region

High-spatial-resolution images of Jupiter were produced on the Hale 200-in. telescope. A programmable wobbling secondary was used to raster-scan the planet with 64 by 64 1-arcsec pixels. Images were made with broadband (8-14 microns) and several 1- and 2-micron-wide filters. All images reveal a belt-and-ozone structure similar to visible photographs. Belts in the broadband data appear to be about 2 K hotter than zones, but contrast varies markedly in different parts of the 8-14-micron spectral region. The lowest belt-zone contrast is found in the hydrogen-opacity-dominated region at 12.5 microns, while images at 9.5 microns exhibit the greatest contrast. Isolated areas are observed to be as much as 4 K hotter than surrounding areas at 9.5 microns. This large contrast is probably due to variations in the distribution of the ammonia clouds in the upper atmosphere.

Terrile, R. J.↗

17-25 micrometer spectra of Jupiter and Saturn

Ground-based spectra of Jupiter and Saturn in the region from 17 to 25 microns are compared with intensities computed from current thermal-structure models. Good agreement with the continuum of Jupiter is obtained for models which incorporate a temperature inversion, but published models give disagreement with the continuum of Saturn. Upper-limit abundances for sulfur and phosphorus in the Jovian atmosphere, as thermodynamically stable species S8 and P4, are found to be 0.04 and 2.1 times the solar abundance, respectively.

Tokunaga, A.↗

8 to 13 micrometer spectrophotometry of compact sources in W3

Three infrared and radio sources in W3 (continuum) and one in W3(OH) have been observed with 1% spectral resolution. Three sources show deep silicate absorption features; the remaining source shows little silicate absorption and has three emission lines. One source, IRS 5, has the deepest silicate absorption known and can be used to determine the wavelength dependence of silicate extinction. Such properties of the sources as dust masses and luminosities are discussed.

Willner, S. P.↗

Advanced development of Pb-salt semiconductor lasers for the 8.0 to 15.0 micrometer spectral region

The technology was studied for producing Pb-salt diode lasers for the 8-51 micron spectral region suitable for use as local oscillators in a passive Laser Heterodyne Spectrometer (LHS). Consideration was given to long range NASA plans for the utilization of the passive LHS in a space shuttle environment. The general approach was to further develop the method of compositional interdiffusion (CID) recently reported, and used successfully at shorter wavelength. This technology was shown to provide an effective and reproducible method of producing a single-heterostructure (SH) diode of either the heterojunction or single-sided configuration. Performance specifications were exceeded in several devices, with single-ended CW power outputs as high as 0.88 milliwatts in a mode being achieved. The majority of the CID lasers fabricated had CW operating temperatures of over 60K; 30% of them operated CW above the boiling temperature of liquid nitrogen. CW operation above liquid nitrogen temperature was possible for wavelengths as long as 10.3 microns. Operation at 77K is significant with respect to space shuttle operations since its allows considerable simplification of cooling method.

Linden, K. J.↗

Continued development of doped-germanium photoconductors for astronomical observations at wavelengths from 30 to 120 micrometers

The development of doped-germanium detectors which have optimized performance in the 30- to 120-mu m wavelength range and are capable of achieving the objectives of the infrared astronomical satellite (IRAS) space mission is discussed. Topics covered include the growth and evaluation of Ge:Ga and Ge:Be crystals, procedures for the fabrication and testing of detectors, irradiance calculations, detector responsivity, and resistance measurements through MOSFET. Test data are presented in graphs and charts.

Bratt, P. R.↗

The 1.1 micrometer and visible emission semiconductor diode lasers

In (AlGa)As, the first of three alloy systems studied, Continuous Wave (CW) operation was obtained at room temperature at a wavelength as low as 7260 A. Reliability in this system was studied in the incoherent mode. Zinc doped devices had significant degradation, whereas Ge or Ge plus Zi doped devices had none. The Al2O3 facet coatings were shown to significantly reduce facet deterioration in all types of lasers, longer wavelength units of that type having accumulated (at the time of writing) 22,000 hours with little if any degradation. A CL study of thin (AlGa)As layers revealed micro fluctuation in composition. A macro-scale fluctuation was observed by electroreflectance. An experimental and theoretical study of the effect of stripe width on the threshold current was carried out. Emission below 7000 A was obtained in VPE grown Ga(AsP) (In,Ga)P with CW operation at 10 C. Lasers and LED's were made by LPE in (InGa) (AsP). Laser thresholds of 5 kA/cm2 were obtained, while LED efficiences were on the order of 2%. Incoherent life test over 6000 hours showed no degradation.

Ladany, I.↗

Luna 24: 90-150 micrometer fraction - Implications for remote sampling of regolith

An analysis of the mineral grains and glasses found in the 90 to 150 micron fraction of the Luna 24 core sample is presented and implications for the automatic collection of planetary and asteroidal regoliths are discussed. Electron microprobe analysis for pyroxene, olivine, plagioclase, opaque minerals and glass in samples at various depths indicate that polymineralic grains have compositions similar to those of gabbroic and basaltic fragments from coarser samples, while monomineralic grains contain an additional population of Mg-rich olivines and pyroxene. Most of the glasses are found to be related to mare basalts or local regolith, with nonmare material represented by glasses of highland basalt and low K Fra Mauro composition. It is concluded that as regards mineralogy and petrology, a single grab sample would have been as useful and a series of grab samples on a long traverse would have been more useful than the Luna 24 core sample, with the fine sample being more informative than the coarse.

Papp, H. A.↗

Electronic depth micrometer

Device for measuring depth or thickness reads distance of penetration by small-diameter probe. It was developed specifically to measure thickness of wet (uncured) insulation applied to Space Shuttle structures; thin probes penetrate wet insulation to substrate, and reference surface on gage is then positioned against outer surface of insulation to measure its thickness. Gage is easy to use, even by workers wearing gloves or other protective clothing, and allows remote reading and recording of production data.

Major, R. K.↗

Some n-p (Hg,Cd)Te photodiodes for 8-14 micrometer heterodyne applications

The results describing the dc and CO2 laser heterodyne characteristics of a three element photodiode array and single element and four element photodiode arrays are presented. The measured data shows that the n(+)-p configuration is capable of achieving bandwidths of 475 to 725 MHz and noise equivalent powers of 3.2 x 10 to the minus 20th power W/Hz at 77 K and 1.0 x 10 to the minus 19th power W/Hz at 145 K. The n(+)-n(-)-p photodiodes exhibited wide bandwidths (approximately 2.0 GHz) and fairly good effective heterodyne quantum efficiencies (approximately 13-30 percent at 2.0 GHz). Noise equivalent powers ranging from 1.44 x 10 to the minus 19th power W/Hz to 6.23 x 10 to the minus 20th power W/Hz were measured at 2.0 GHz.

Shanley, J. F.↗

Five-micrometer measurements of Uranus and Neptune

Five-micron brightness temperatures and brightness temperature upper limits for Uranus and Neptune have been obtained which are substantially lower than those of Jupiter and Saturn and which correspond to a geometric albedo of approximately 0.01, in agreement with results reported by Gillett and Rieke (1977). Phosphine and CH3D, which are observed at 5 microns on Jupiter and Saturn, are discussed as possible sources of opacity at 5 microns in the atmospheres of Uranus and Neptune.

Macy, W. W., Jr.↗

Submillimeter heterodyne detection of interstellar carbon monoxide at 434 micrometers

Laser heterodyne observations of submillimeter emissions from carbon monoxide in the Orion molecular cloud are reported. High frequency and spatial resolution observations were made at the NASA Infrared Telescope Facility on Mauna Kea by the use of an optically pumped laser local oscillator and quasi-optical Schottky diode mixer for heterodyne detection of the J = 6 - 5 rotational transition of CO at 434 microns. Spectral analysis of the 434-micron emission indicates that the emitting gas is optically thin and is at a temperature above 180 K. Results thus demonstrate the potential contributions of ground-based high-resolution submillimeter astronomy to the study of active regions in interstellar molecular clouds.

Fetterman, H. R.↗

Development of an earth resource pushbroom scanner utilizing a 90-element 8-14 micrometer /Hg,Cd/Te array

A detailed description is presented of thermal infrared 'pushbroom' scanners being developed for NASA's earth resources survey experiments in the middle to late 1980's. The devices offer high spectral, temporal and spatial resolution, and great reliability as well, due to simplicity of design. Their mode of operation does not require moving optics, since chopping and calibration are integral. The specific device described, a 90-element IR/CCD instrument, was developed to demonstrate scan imagery in the 8-14 micron spectral region in simulated aircraft tests. The scanning operation covers a straight-line path with a linear array of solid-state IR detectors, whose elements are activated sequentially in the cross-track direction while being swept forward along a flight path that, at an aircraft altitude of 10 km, is 7 km wide.

Brown, T. J.↗

Development of MBE grown Pb-salt semiconductor lasers for the 8.0 to 15.0 micrometer spectral region

Diodes lasers are fabricated using multiple source molecular beam expitaxial growth of (PbSn)Te on BaF2 substrates. Methods for crystal growth, crystal transfer, and device fabrication by photolithographic techniques were developed. The lasers operate in the spectra range from 10 microns to 14 microns and at temperatures from 12K to 60K continuous wave and to 95 K pulsed.

Miller, M. D.↗

Modelling of the 10-micrometer natural laser emission from the mesospheres of Mars and Venus

The NLTE radiative transfer problem is solved to obtain the 00 deg 1 vibrational state population. This model successfully reproduces the existing center-to-limb observations, although higher spatial resolution observations are needed for a definitive test. The model also predicts total fluxes which are close to the observed values. The strength of the emission is predicted to be closely related to the instantaneous near-IR solar heating rate.

Deming, D.↗

1.0 to 2.5 micrometer short wavelength infrared /SWIR/ linear array technology for low background applications

A design concept is presented for a hybrid linear focal plane array operating in the 1.0 to 2.5 micron band under low background conditions such as encountered in spaceborne missions. The concept is based on direct gate coupling of the input from a photovoltaic mercury-cadmium telluride detector into a CCD multiplexer. Theoretical analysis indicates a specific detectivity at peak wavelength on the order of 10 to the 12th cm sq rt Hz/W when the system is operating at 200 K. Values of the voltage responsivity, specific detectivity and the relative voltage noise levels of the coupled system obtained in experimental studies with direct-gate-coupled 4.0-micron detectors support the theoretical analysis performed for the case of system detectivity limited by the CCD 1/f noise.

Stobie, J.↗

Calculations of atmospheric transmittance in the 11 micrometer window for estimating skin temperature from VISSR infrared brightness temperatures

An algorithm for calculating the atmospheric transmittance in the 10 to 20 micro m spectral band from a known temperature and dewpoint profile, and then using this transmittance to estimate the surface (skin) temperature from a VISSR observation in the 11 micro m window is presented. Parameterizations are drawn from the literature for computing the molecular absorption due to the water vapor continuum, water vapor lines, and carbon dioxide lines. The FORTRAN code is documented for this application, and the sensitivity of the derived skin temperature to variations in the model's parameters is calculated. The VISSR calibration uncertainties are identified as the largest potential source of error.

Chesters, D.↗