Search NASA⌕ Search

SEARCH · Search NASA

Results for “Organic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Discriminating Uranium Isotopes Based on Fission Signatures Induced by Delayed Neutrons

The use of active interrogation to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials. Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., 235 U or 233 U) fraction, such as highly enriched uranium (HEU), delayed neutrons have a high probability of inducing additional fissions. As a result, the overall delayed neutron signature consists of two distinct components: the “primary” delayed neutrons (emitted directly by fission fragments) and the “secondary prompt” fission neutrons produced in fission induced by primary delayed neutrons. These prompt products differ from “primary” delayed neutrons both in their energy spectra and in the presence of coincident radiation released by the parent fission event. The presence and relative quantity of prompt products from delayed fission depend on the cross section of the material in the energy range of delayed neutrons, which may differ significantly between isotopes, thus providing an exploitable means for isotope differentiation. Here, we demonstrate two experimental approaches for discriminating between 235 U and 238 U isotopes based on the measurement of delayed neutron-induced fission products. First, HEU and depleted uranium objects are differentiated through the detection of high-energy prompt neutrons from delayed fission using both recoil-based organic liquid scintillators and thermalization spectra from a custom-built capture-gated composite detector. Secondly, coincident radiation measurements are used as the basis for discrimination by comparing the overall rates and time evolution of fission events when delayed neutrons are present.

07 ISOTOPE AND RADIATION SOURCES↗

Forward modeling approach to nuclear reaction cross sections: Applications in neutron inelastic scattering

The development of nuclear reaction models for the production of evaluated nuclear data has traditionally been performed by comparing measured cross sections with predictions from reaction model codes whose physical input parameters are adjusted to obtain the best agreement between measured and modeled results. To more directly probe reaction model inputs, this work introduces a forward modeling approach to experimental reaction cross-section determination, where the most important physical input parameters to reaction model calculations are obtained via 𝜒 2 minimization between measured and calculated observables. This was demonstrated using data collected by the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) at the 88-inch cyclotron at Lawrence Berkeley National Laboratory, a detection array consisting of organic liquid scintillators and high-purity germanium (HPGe) detectors. Using a broad-spectrum neutron beam and a 99.98%-enriched 56 Fe target, GENESIS was used to perform a simultaneous measurement of 56 Fe 𝛾-ray production cross sections and secondary neutron energy and angle distributions. The results of the forward modeling approach to the determination of energy-differential 𝛾-ray production cross sections for the yrast 4 + → 2 + and 6 + → 4 + transitions, as well as eight other off-yrast transitions, were compared against those obtained using conventional techniques, and the results are in good agreement. In addition to discrete 𝛾-ray yield total scattered neutron energy-angular distributions as a function of incident neutron energy were also obtained using forward modeling and found to agree with evaluated data, with the exception of elastic scattering at small angles. The fitted reaction model parameters obtained through forward modeling were also used to calculate the cross section for the unobserved (𝑛, 2⁢𝑛) reaction; excellent agreement with the current evaluation was obtained, providing a validation of the predictive capabilities of the forward model approach. This work bridges the gap between nuclear data experiment and evaluation by providing a new means for extracting inelastic neutron-scattering cross sections and neutron-induced 𝛾-ray production data while directly probing reaction model physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulated X-Ray Radiographic Performance of a Bismuth-Loaded PVT Array

Recent material advancements in organic plastic scintillators enable marked increases in material detection efficiency, light yield, and pulse shape discrimination properties. These advances may resolve significant capability gaps for lowcost, portable, and durable dual-particle imaging (DPI) systems for nuclear safety, security, and safeguard purposes. One such material, a 21% bismuth-loaded polyvinyl toluene (BiPVT), is computationally evaluated as a small, pixelated radiographic array using Monte Carlo N-Particle (MCNP) and Zemax OpticStudio, and it is compared to identical evaluations of EJ-200 and EJ-256 arrays. MCNP software enables estimates of particle interaction and energy deposition, while OpticStudio computes optical light transport within each material. Here, computational estimates of spatial resolution and relative light collection at 370 kVp are found to agree with experimental results for both EJ-200 and EJ-256 arrays, thereby validating predictions of the same for the BiPVT array. As such, for equivalent exposures at 370 kVp, a BiPVT array may provide ~20× the light collection expected from EJ-200 and ~10× that expected from EJ-256. Similar comparisons of estimated light collection are also computed at 150 and 270 kVp, and these results suggest that BiPVT will provide significantly improved performance over EJ-200 and EJ-256 across all energies practical for portable X-ray radiography.

42 ENGINEERING↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System Response Characterization for a d–t Neutron Radiography System

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy neutrons at balloon altitudes

The flux and energy spectrum of fast neutrons (3 to 20 MeV) has been measured near the top of the atmosphere with an organic liquid scintillator. The omnidirectional neutron energy spectrum from 3 to 20 MeV at 3.5 g/sq cm over Palestine, Texas can be described by a power law with an energy dependent spectral index which varies from 1.8 (plus or minus .2) between 1 and 10 MeV to 0.3 (plus or minus .3) between 15 and 20 MeV. From 20 to 50 MeV, a neutron spectrum independence of E is consistent with our data.

Klumpar, D. M.↗

Energy spectrum and flux of fast neutrons in the atmosphere

The neutron energy spectrum and flux in the atmosphere at the Pfotzer maximum (about 100 g per cm squared) were measured at geomagnetic latitude 42 deg N, using a system capable of detecting a small flux of fast (5 to 20 MeV) neutrons in a much larger background flux of gamma rays and charged particles. The detector consisted of a cylindrical cell of organic liquid scintillator coupled to a high-resolution two-parameter multiparticle pulse shape discriminator with a two-parameter logarithmic pulse-height analyzer. The spectral parameter for the differential neutron energy spectrum was found to decrease from 4.4 plus or minus 0.8 between 3.5 and 6.0 MeV to 1.5 plus or minus 1.0 in the interval 11 to 20 MeV; a value of 0.36 plus or minus 0.10 neutrons per cm squared was calculated for neutron flux between 3.5 and 10 MeV. The importance of these results for evaluating the role of albedo neutron leakage as a source of the energetic proton flux in the radiation belts is also considered.

Saint Onge, R. N.↗

Systematic study of radioluminescence and light propagation effects in scintillating nanoguide materials

Nanoguide optical waveguides are thermally processed materials based on polymers that have different refractive indices. Scintillating versions of these materials have been under development since 2019 and feature PMMA as the low refractive index constituent and Organic Glass Scintillator-polymer blends as the high index component. Characterization efforts to date have focused on the functional characteristics of nanoguide pertaining to its envisioned use in high-resolution transmission radiography applications.

36 MATERIALS SCIENCE↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of particle-dependent light response for defining detector response functions

This study comprehensively characterizes two scintillation detectors, an organic deuterated liquid and a stilbene crystal, concerning their response to charged particles such as electrons, protons, alphas, and carbon nuclei. The Birks function was used to determine the detectors’ response to charged particles, enabling the determination of particle-dependent light responses. The particle-dependent light characterization was used to determine detector response functions (DRF) using Geant in combination with Gamma Detector Response and Analysis Software (GADRAS). These DRFs enhance GADRAS by enabling full spectral analysis functionality for previously underrepresented detector materials. Additionally, neutron-specific DRFs are determined for neutron energy spectrum unfolding applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiaxis sensing system for detection of airborne molecules and radionuclides

Various technologies presented herein relate to a method and equipment for detecting both airborne radioisotope and molecular effluent gases. Multi-Axis Sensing can be conducted by utilizing a pressurized MOF sorbent, such as a scintillating Metal-Organic Frameworks (S-MOFs). These MOFs are crystalline nanoporous materials that have synthetic versatility that allow adjustment of pore size, chemical environment, and luminescence properties. A method for detecting an analyte in a fluid sample is provided that comprises: loading a sorbent with a sample fluid, wherein the sorbent comprises a MOF material; pressurizing the sample fluid to increase the fluid in the sorbent thereby making a pressurized sorbent; and detecting ionizing radiation or a chemical property of the analyte in the pressurized sorbent.

Allendorf, Mark D.↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of irrigation approaches and spatial geolocation on tritium speciation, uptake and depuration

Pine needles and tree cores from a tritium (T) contaminated phytoremediation forest at the Savannah River Site (SRS in Aiken, SC) Mixed Waste Management Facility (MWMF) were measured for total T and T speciation and compared to other locations at the SRS and the surrounding area. Tree core ages ranged from 9 to 14 years old, covering over half of the ~20-year on-going remediation efforts, while pine needles represent more recent time periods of 1-to-2-year increments. Remedial irrigation efforts at the MWMF are found to directly influence the pine needle T concentrations. The T content in the MWMF samples is higher than non-irrigated needle samples from other locations around the SRS. Furthermore, the different forms of organic bound T are preferentially stored in tree core tissue, compared to pine needles where tritiated water dominates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗