Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE COEFFICIENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Exploration of Fuel Property Impacts on the Combustion of Late Post Injections Using Binary Blends and High-Reactivity Ether Bioblendstocks

In this study, the impacts of fuel volatility and reactivity on com- bustion stability and emissions were studied in a light-duty single- cylinder research engine for a three-injection catalyst heating oper- ation strategy with late post-injections. N-heptane and blends of farnesane/2,2,4,4,6,8,8-heptamethylnonane were used to study the im- pacts of volatility and reactivity. The effect of increased chemical reac- tivity was also analysed by comparing the baseline #2 diesel operation with a pure blend of mono-ether components (CN > 100) representa- tive of potential high cetane oxygenated bioblendstocks and a 25 vol.% blend of the mono-ether blend and #2 diesel with a cetane number (CN) of 55. At constant reactivity, little to no variation in combustion performance was observed due to differences in volatility, whereas in- creased reactivity improved combustion stability and efficiency at late injection timings. Fuels with higher reactivity were found to reduce engine-out hydrocarbon and carbon monoxide emissions while also achieving stable combustion at post-injection timings later than those achievable with #2 diesel fuel. The pure ether blend had the latest achievable post-injection timing of +30.5 CAD while still maintaining stable combustion (coefficient of variation of gross-indicated mean ef- fective pressure < 5%). With post-injection timing adjusted to achieve a matched exhaust temperature of 300 °C, the ether-diesel CN 55 blend was observed to have slightly higher thermal efficiency in comparison to the baseline #2 diesel fuel. The results also indicate that cetane num- ber may serve as a good indicator of combustion characteristics at late injection timings used for aftertreatment thermal management opera- tion.

99 GENERAL AND MISCELLANEOUS↗

Electrical, structural and thermomechanical properties of doped-LaCrO3 ceramics for high temperature electronics and sensing applications.

Many important electrical and sensor applications require stable conductors under working temperatures up to 1500oC various redox environments. Common high temperature conductors such as nitrides and carbides are not stable under oxidizing atmospheres, for this reason low redox behavior materials would be more attractive. In this work, further dopant studies of the LaCrO3 system were completed in order to control the electronic and ionic conductivity, as well as the relative chemical and microstructural stability. Neodymium and Niobium dopants were initially studied to control the p-type, and potentially n-type conductive mechanisms, respectively, but other dopants strategies were also investigated. The electrical conductivity and Seebeck coefficient were characterized up to 1500oC under varying oxygen partial pressures. The phase and microstructural evolution of each material was also investigated for these compositions by XRD and SEM. The materials showing the best electrical and thermomechanical performance were included within thick films sensors and were tested.

20 FOSSIL-FUELED POWER PLANTS↗

Additively Manufactured Compliant Hybrid Gas Thrust Bearing for Supercritical Carbon Dioxide Turbomachinery: Design and Proof of Concept Testing

The following paper presents a new type of gas lubricated thrust bearing that utilizes additive manufacturing or also known as direct metal laser melting (DMLM) to fabricate the bearing. The motivation for the new bearing concept is derived from the need for highly efficient supercritical carbon dioxide (sCO2) turbomachinery in the mega-watt power range. The paper provides a review of existing gas thrust-bearing technology, outlines the need for the new DMLM concept, and discusses proof-of-concept testing results. The new concept combines hydrostatic pressurization with individual tilting pads that are flexibly mounted using hermetic squeeze film dampers (HSFD) in the bearing-pad support. This paper describes the thrust-bearing concept and discusses the final design approach. Proof-of-concept testing in air for a 6.8 in. (173 mm) outer diameter thrust gas bearing was performed; with thrust loading, up to 1500 lbs (6.67 kN) and a thrust runner speed of 10krpm (91 m/s tip speed). The experiments were performed with a bent shaft resulting in thrust runner axial vibration magnitudes of 2.9 mils (74 μm) p-p and dynamic thrust loads of 270 lbs (1.2 kN) p-p. In addition, force deflection characteristics and stiffness coefficients of the bearing system are presented for an inlet hydrostatic pressure of 380 psi (2.62 MPa). Results at 10 krpm show that the pad support architecture was able to sustain high levels of dynamic misalignment equaling 6 times the nominal film clearance while demonstrating a unit load-carrying capacity of 55 psi (0.34 Mpa). Gas-film force deflection tests portrayed nonlinear behavior like a hardening spring, while the bearing pad support stiffness was measured to be linear and independent of gas film thickness.

Engineering↗

Ignition delay times of NH 3 /DME blends at high pressure and low DME fraction: RCM experiments and simulations

Here, autoignition delay times of ammonia/dimethyl ether (NH 3 /DME) mixtures were measured in a rapid compression machine with DME fractions of 0, 2 and 5 and 100% in the fuel. The measurements were performed at equivalence ratios $\varphi$= 0.5, 1.0 and 2.0 and pressures in the range 10–70 bar; depending on the fuel composition, the temperatures after compression varied from 610 K to 1180 K. Admixture of DME is seen to have a dramatic effect on the ignition delay time, effectively shifting the curves of ignition delay vs. temperature to lower temperatures, up to ~250 K compared to pure ammonia. Two-stage ignition is observed at $\varphi$= 1.0 and 2.0 with 2% and 5% DME in the fuel, despite the pressure being higher than that at which pure DME shows two-stage ignition. At $\varphi$= 0.5, a reproducible pre-ignition pressure rise is observed for both DME fractions, which is not observed in the pure fuel components. A novel NH 3 /DME mechanism was developed, including modifications in the NH 3 subset and addition of the NH 2 + CH 3 OCH 3 reaction, with rate coefficients calculated from ab initio theory. Simulations faithfully reproduce the observed pre- ignition pressure rise. While the mechanism also exhibits two-stage ignition for NH 3 /DME mixtures, both qualitative and quantitative improvement is recommended. The overall ignition delay times for ammonia/DME mixtures are predicted well, generally being within 50% of the experimental values, although reduced performance is observed for pure ammonia at $\varphi$= 2.0. Simulating the ignition process, we observe that the DME is oxidized much more rapidly than ammonia. Analysis of the mechanism indicates that this ‘early DME oxidation’ generates reactive species that initiate the oxidation of ammonia, which in turn begins heat release that raises the temperature and accelerates the oxidation process towards ignition. The reaction path analysis shows that the low-temperature chain-branching reactions of DME are important in the early oxidation of the fuel, while the sensitivity analysis indicates that several reactions in the oxidation of DME, including cross reactions between DME and NH 3 species presented here, are critical to ignition, even at fractions of 2% DME in the fuel.

10 SYNTHETIC FUELS↗

Modeling Stress-Induced Pore Water Pressures in The Vadose Zone Beneath a Composite-Lined Landfill - 20029

A finite-element model was developed to evaluate mechanisms contributing to positive pore pressures measured with sealed pressure transducers in the geological buffer beneath the Environmental Management Waste Management Facility, a composite-lined mixed waste disposal facility operated by the US Department of Energy. The geological buffer is a 3-m-thick engineered fine-textured layer directly beneath the Environmental Management Waste Management Facility's composite liner, and above the groundwater table. The model accounts for changes in pore water pressure resulting from (i) loading imposed by waste placed on the overlying liner, (ii) moistening of the geological buffer due to equilibration with the underlying geological materials, and (iii) fluctuations in the elevation of the underlying groundwater table. Pore water pressures predicted by the model are in good agreement with pore water pressures measured in the field. The predictions confirm that positive pore water pressures recorded by the sealed pressure transducers in the geological buffer are excess pore water pressures induced by the vertical normal stress imposed by waste placed on the liner, and are not due to a rise in the groundwater table. Simulations also showed that two additional years of filling would further increase the pore water pressure without any change in elevation of the groundwater table. The geological buffer remained unsaturated during the simulation, with a B-coefficient (parameter indicative of the degree of saturation) similar to that computed from the field-measured pore water pressures and waste filling records. Larger increases in pore water pressure were observed when the geological buffer was assumed to have higher initial saturation, as was observed in the field data. Incorporating seasonal fluctuations in the groundwater table beneath the geological buffer in the model resulted in predictions of small seasonal oscillation in the pore water pressure at the measurement location, similar to seasonal oscillations observed in the field. Predictions made with the model indicate that the dissipation of the excess pore water pressures will occur over decades due to the low hydraulic conductivity of the geological buffer material. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In‐mold rheology and automated process control for injection molding of recycled polypropylene

Abstract Manufacturing plastic parts with secondary feedstocks has risen to the forefront of importance in recent years. However, the variation in molecular weight and rheology of secondary feedstock can lead to inconsistent part quality. This work evaluates the effectiveness of a novel closed‐loop adaptive process control system that adjusts nozzle pressure in response to in‐mold pressure data. Five different recycled polypropylene blends, with a broad distribution of flow properties, were evaluated to determine the effectiveness of the control system at reducing processing variation. The experimental results show that the process control strategy reduced the variation within the mold, as seen by in‐mold pressure curves and calculated in‐mold viscosity values. Additionally, the parameters that control the automated process adjustments were investigated, showing the importance of optimization. The analysis of the correlation between in‐mold rheology and mechanical properties showed a slight variation in the mechanical properties and parts weight with a coefficient of variation of under 5%. Overall, the results demonstrate the ability of pressure‐controlled molding and automated viscosity adjustment to reduce the variability when molding a secondary feedstock. Highlights Pressure‐controlled injection molding of recycled polypropylene. Automated closed‐loop adaptive process control methodology. Methodology resulted in a reduction in pressure variation during molding. Changes in mechanical properties and in‐mold viscosity were investigated. Results show the potential of pressure‐controlled molding at reducing variation.

Krantz, Joshua↗

Thermal equation of state for zoisite: Implications for the transportation of water into the upper mantle and the high-velocity anomaly in the Farallon plate

Seismic tomography studies have revealed a high-velocity anomaly at depths between 100 km and 300 km in the Farallon plate. However, the reasons for the high-velocity anomaly continue to be debated. An analysis of the mineral proportions of eclogites exhumed from the Farallon plate shows that the average amount of zoisite in eclogite is ∼16.0 vol%. Therefore, the presence of zoisite eclogite needs to be considered to explain the high-velocity anomaly of the Farallon plate. However, the thermal equation of state and stability of zoisite have not been fully investigated under high pressure−temperature (P-T) conditions. We investigated the high-pressure and high-temperature behavior of natural zoisite utilizing synchrotron single crystal-X-ray diffraction (XRD). The results indicate that zoisite is metastable up to 24.8 GPa and 700 K. We obtained the ambient unit-cell volume V0 = 901.26(3) Å3 by synchrotron single crystal-XRD measurement. We also fitted the pressure-volume-temperature data to a high-temperature Birch-Murnaghan equation of state and obtained the zero-pressure bulk modulus K0 = 134.7(8) GPa, the temperature derivative of the bulk modulus (∂K/∂T)P = −0.011(4) GPa/K, and the thermal expansion coefficients α0V = 1.9(7) × 10−5 K−1 and α1V = 3(2) × 10−8 K−2 when the pressure derivative of bulk modulus (K′0) is fixed at 4. By incorporating the results from previous studies, we calculated the density and bulk sound velocity profiles of zoisite eclogite along the Farallon plate geotherm. Finally, we infer that zoisite could carry water to depths of ∼300 km within cold subducting slabs and that the bulk sound velocity of typical zoisite eclogite with ∼61.0 vol% omphacite, ∼23.0 vol% garnet, and ∼16.0 vol% zoisite could cause the high-velocity anomalies at depths of 100−300 km in the Farallon plate.

Geology↗

CO 2 Sorption in Moisture Swing Anion Exchange Resins for Direct Air Capture: Experimental Isotherm Determination and Modeling

Moisture swing (MS) sorption is a promising direct air capture (DAC) technology to achieve negative CO 2 emissions and counter global warming. Here, in this study, MS CO 2 sorption in a model MS sorbent, IRA900, was investigated. IRA900 is a macroporous commercial strong-base anion exchange resin (AER) with quaternary ammonium functional groups. A rigorous CO 2 desorption process was developed to desorb all CO 2 from the sample and obtain CO 2 sorption isotherms as a function of relative humidity, CO 2 partial pressure, and temperature. CO 2 sorption increased with decreasing relative humidity, decreasing temperature, and increasing CO 2 partial pressure. Remarkably, the total CO 2 uptake from the sorption isotherms matched the ion exchange capacity (IEC) of the material, suggesting a stoichiometry of one CO 2 molecule reacting per active site. An isotherm model for CO 2 sorption starting with empty sorption sites (i.e., with the AER in the OH – form) described the experimental data well, supporting the hypothesis that the bicarbonate-loaded AER fully unloaded to the OH – state following rigorous CO 2 desorption. CO 2 sorption kinetics were studied, and carbon diffusion coefficients were estimated as a function of %RH and CO 2 partial pressure. Overall, this study provides a roadmap for the systematic evaluation of MS CO 2 DAC materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Hermetic Package Technique for Multi-Functional Fiber Sensors through Pressure Boundary of Energy Systems Based on Glass Sealants

This paper presents a hermitic fiber sensor packaging technique that enables fiber sensors to be embedded in energy systems for performing multi-parameter measurements in high-temperature and strong radiation environments. A high-temperature stable Intrinsic Fabry–Perot interferometer (IFPI) array, inscribed by a femtosecond laser direct writing scheme, is used to measure both temperature and pressure induced strain changes. To address the large disparity in thermo-expansion coefficients (TECs) between silica fibers and metal parts, glass sealants with TEC between silica optical fibers and metals were used to hermetically seal optical fiber sensors inside stainless steel metal tubes. The hermetically sealed package is validated for helium leakages between 1 MPa and 10 MPa using a helium leak detector. An IFPI sensor embedded in glass sealant was used to measure pressure. The paper demonstrates an effective technique to deploy fiber sensors to perform multi-parameter measurements in a wide range of energy systems that utilize high temperatures and strong radiation environments to achieve efficient energy production.

Optics↗

Semi-Analytic Functions to Calculate the Deposition Coefficients for Ice Crystal Vapor Growth in Bin and Bulk Microphysical Models

Numerical cloud models require estimates of the vapor growth rate for ice crystals. Current bulk and bin microphysical parameterizations generally assume that vapor growth is diffusion limited, though some parameterizations include the influence of surface attachment kinetics through a constant deposition coefficient. A parameterization for variable deposition coefficients is provided herein. The parameterization is an explicit function of the ambient ice supersaturation and temperature, and an implicit function of crystal dimensions and pressure. The parameterization is valid for variable surface types including growth by dislocations and growth by step nucleation. Deposition coefficients are predicted for the two primary growth directions of crystals, allowing for the evolution of the primary habits. Comparisons with benchmark calculations of instantaneous mass growth indicate that the parameterization is accurate to within a relative error of 1%. Parcel model simulations using Lagrangian microphysics as a benchmark indicate that the bulk parameterization captures the evolution of mass mixing ratio and fall speed with typical relative errors of less than 10%, whereas the average axis lengths can have errors of up to 20%. The bin model produces greater accuracy with relative errors often less that 10%. The deposition coefficient parameterization can be used in any bulk and bin scheme, with low error, if an equivalent volume spherical radius is provided.

54 ENVIRONMENTAL SCIENCES↗

Harnessing Machine Learning to Predict MoS 2 Solid Lubricant Performance

Physical vapor deposited (PVD) molybdenum disulfide (MoS 2 ) solid lubricant coatings are an exemplar material system for machine learning methods due to small changes in process variables often causing large variations in microstructure and mechanical/tribological properties. Here, in this work, a gradient boosted regression tree machine learning method is applied to an existing experimental data set containing process, microstructure, and property information to create deeper insights into the process-structure–property relationships for molybdenum disulfide (MoS 2 ) solid lubricant coatings. The optimized and cross-validated models show good predictive capabilities for density, reduced modulus, hardness, wear rate, and initial coefficients of friction. The contribution of individual deposition variables (i.e., argon pressure, deposition power, target conditioning) on coating properties is highlighted through feature importance. The process-property relationships established herein show linear and non-linear relationships and highlight the influence of uncontrolled deposition variables (i.e., target conditioning) on the tribological performance.

MoS2↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Advances and challenges in CO2 foam technologies for enhanced oil recovery in carbonate reservoirs

Utilization of surfactants for generating foam has the potential for fluid-mobility control during CO2 flooding processes, leading to improved oil recovery. This manuscript is a review of the most important aspects for the design of CO2-foams with mobility control in carbonate reservoirs, including recent advances in novel surfactants and analytical techniques for analysis of surfactant adsorption on carbonate minerals and their thermal stability. Several key parameters and properties regarding foam transport in porous media are reviewed such as, the minimum pressure gradient required for foam generation, the effects of the partition coefficient of a CO2-soluble surfactant on foam transport in rock cores, visualization of foam flow by either microfluidic or PET/CT imaging processes in heterogeneous or fractured systems and the effect of oil on foam transport under reservoir conditions. Also are discussed the most recent advances of two major foam modeling methods, including the semi-empirical STARS foam model and the population balance model, as well as CO2 foam pilot tests and the factors governing their successes.

Jian, Guoqing↗

Association Kinetics for Perfluorinated n -Alkyl Radicals

Radical-radical reaction channels are important in the pyrolysis and oxidation chemistry of perfluoroalkyl substances (PFAS). In particular, unimolecular dissociation reactions within unbranched n-perfluoroalkyl chains, and their corresponding reverse barrierless association reactions, are expected to be significant contributors to the gas-phase thermal decomposition of families of species such as perfluorinated carboxylic acids and perfluorinated sulfonic acids. Unfortunately, experimental data for these reactions are scarce and uncertain. Furthermore, obtaining reliable theoretical predictions for such reactions is a laborious and computationally intensive task. Here, in this work, the chemical kinetics of the various association/decomposition reactions producing/decomposing the C 2 -C 4 series of unbranched n-perfluoroalkanes (C 2 F 6 , C 3 F 8 , and C 4 F 10 ) are examined using state-of-the-art ab initio transition-state-theory-based master-equation calculations. The variable-reaction-coordinate transition-state theory (VRC-TST) formalism is employed in computing the microcanonical and canonical rates for the association reactions. Reaction thermochemistry is obtained via composite quantum chemistry calculations and the laddering of error-canceling reaction schemes via a connectivity-based hierarchy approach employing ANL1/ANL0-style reference energies. Lennard-Jones collision model parameters for the considered systems were estimated by a direct dynamics approach, and collisional energy transfer parameters were obtained from analogies to systems of similar size and heavy-atom connectivity. A one-dimensional master equation approach was used to convert the microcanonical rate coefficients from the VRC-TST analysis into temperature- and pressure-dependent rate constants for the association reactions and the reverse dissociation reactions. The data are reported in standardized formats for usage in comprehensive chemical kinetic models for PFAS thermal destruction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MoVN-Cu Coatings for In Situ Tribocatalytic Formation of Carbon-Rich Tribofilms in Low-Viscosity Fuels

Inhibiting the tribological failure of mechanical assemblies which rely on fuels for lubrication is an obstacle to maintaining the lifetime of these systems with low-viscosity and low-lubricity fuels. Here in the present study, a MoVN-Cu nanocomposite coating was tribologically evaluated for durability in high- and low-viscosity fuels as a function of temperature, load, and sliding velocity conditions. The results indicate that the MoVN-Cu coating is effective in decreasing wear and friction relative to an uncoated steel surface. Raman spectroscopy, transmission electron microscopy, and electron-dispersive spectroscopy analysis of the MoVN-Cu worn surfaces confirmed the presence of an amorphous carbon-rich tribofilm which provides easy shearing and low friction during sliding. Further, the characterization of the formed tribofilm revealed the presence of nanoscale copper clusters overlapping with the carbon peak intensities supporting the tribocatalytic origin of the surface protection. The tribological assessment of the MoVN-Cu coating reveals that the coefficient of friction decreased with increasing material wear and initial contact pressure. These findings suggest that MoVN-Cu is a promising protective coating for fuel-lubricated assemblies due to its adaptive ability to replenish lubricious tribofilms from hydrocarbon environments.

36 MATERIALS SCIENCE↗

Experimental Characterization of Hydrogen Diffusion in Shale Rocks for Geologic Storage Applications

As global energy systems undergo a transition to cleaner alternatives, geologic hydrogen storage has emerged as a promising solution for large-scale energy storage. A critical factor in determining the feasibility of this approach is the effectiveness of caprock formations, such as shale, in preventing hydrogen migration. This study investigates the diffusion behavior of hydrogen through shale to assess its suitability as a caprock for geologic hydrogen storage. Using a novel double-seal core holder design and a through-diffusion apparatus, hydrogen diffusion was measured through shale rock from the Eagle Ford and Wolfcamp Formations under dry conditions. These measurements were complemented by microstructural and mineralogical analyses using low-pressure nitrogen adsorption and X-ray diffraction. The effective diffusion coefficient of hydrogen in these shale caprocks ranged from 2.51 × 10 –8 to 9.85 × 10 –8 m 2 /s. Notably, we observed that the diffusion behavior was more related to the pore network structure and could not be attributed to differences in the total pore volume between shale types alone. Here, to further understand the role of pore network complexity, a fractal pore model was developed to correlate tortuosity with the fractal dimension of the pore structure (a measure of pore network complexity). The proposed model closely matched tortuosity values obtained from diffusion experiments, outperforming existing theoretical tortuosity–porosity correlations. These findings provide key quantitative parameters needed to assess the feasibility of geologic hydrogen storage as well as insights that can be applied to hydrogen storage in a range of geologic formations.

08 HYDROGEN↗

Parametric and Sensitivity Analysis of a Steam Generator Model Using Python and Machine-Learning Tools

For this study, we used Python and machine-learning tools to perform a comprehensive parametric and sensitivity analysis on a steam generator (SG) model. (The Python model was based on a previously completed MATLAB framework for the Holtec SMR-160 SG.) We investigated the influence of various input parameters (e.g., heat transfer coefficient [HTC], Nusselt number, and heat exchanger effectiveness) on the system’s output. With machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN), which was developed at Idaho National Laboratory, we were then able to perform an automated analysis of the SG inputs’ effect on the HTC. The analysis results give valuable insights into the performance and optimization of SG systems. We found the inlet mass flow rate (MFR) to have the greatest impact on the HTC, followed closely by the inlet temperature, and then pressure. Shifting of the input parameters causes the location of the maximum HTC along the SG length to change incrementally. The cold leg (CL) MFR was also found to impact the HTC magnitude as well as the location of the maximum HTC. At between 0.4–0.9 of the total SG length, the input parameters experience maximum impact on the HTC, leading us to suggest that sensors be efficiently placed on the SG so as to closely and effectively monitor thermal-hydraulic properties during reactor operation. We also found that the sensitivity data calculated manually agrees with the RAVEN – based data, confirming the same range of maximum sensitivity. However, the RAVEN-based analysis showed that cold leg pressure and hot leg temperature have a greater impact on the heat transfer coefficient than the mass flow rate, implying that a manual sensitivity study taking only two samples is not accurate.

20 FOSSIL-FUELED POWER PLANTS↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗