Search NASA⌕ Search

SEARCH · Search NASA

Results for “PTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Progress Report on Disassembly and Post-Irradiation Experiments for UCSB ATR-2 Experiment

The reactor pressure vessel (RPV) in a light-water reactor (LWR) represents the first line of defense against a release of radiation in case of an accident. Thus, regulations that govern the operation of commercial nuclear power plants require conservative margins of fracture toughness, both during normal operation and under accident scenarios. In the unirradiated condition, the RPV has sufficient fracture toughness such that failure is implausible under any postulated condition, including pressurized thermal shock (PTS) in pressurized water reactors (PWR). In the irradiated condition, however, the fracture toughness of the RPV may be severely degraded, with the degree of toughness loss dependent on the radiation sensitivity of the materials. As stated in previous progress reports, the available embrittlement predictive models, e.g. [1], and our present understanding of radiation damage are not fully quantitative, and do not treat all potentially significant variables and issues, particularly considering extension of operation to 80y.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing of the KRI-developed Silicon PIN Radioxenon Detector

Radioxenon detectors are used for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) in a network of detectors throughout the world called the International Monitoring System (IMS). The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS) has tasked Pacific Northwest National Laboratory (PNNL) with testing a V.G. Khlopin Radium Institute (KRI) and Lares Ltd-developed Silicon PIN detector for radioxenon detection. PNNL measured radioxenon with the silicon PIN detector and determined its potential compared to current plastic scintillator beta cells. While the PNNL tested Si detector experienced noise issues, a second detector was tested in Russia at Lares Ltd, which did not exhibit the noise issues. Without the noise issues, the Si detector produces much better energy resolution and isomer peak separation than a conventional plastic scintillator cell used in the SAUNA systems in the IMS. Under the assumption of 1 cm 3 of Xe in laboratory-like conditions, 24-hr count time (12-hr count time for the SAUNA), with the respective shielding the minimum detectable concentrations for the Si detector tested by Lares Ltd (and a conventional SAUNA system) were calculated to be: 131m Xe – 0.12 mBq/m 3 (0.12 mBq/m 3 ); 133 Xe – 0.18 mBq/m 3 (0.21 mBq/m 3 ); 133m Xe – 0.07 mBq/m 3 (0.15 mBq/m 3 ); 135 Xe – 0.45 mBq/m 3 (0.67 mBq/m 3 ). Detection limits, which are one of the important factors in choosing the best detection technique for radioxenon in field conditions, are significantly better than for SAUNA-like detection systems for 131m Xe and 133m Xe, but similar for 133 Xe and 135 Xe. Another important factor is the amount of “memory effect” or carry over signal from one radioxenon measurement to the subsequent sample. The memory effect is reduced by a factor of 10 in the Si PIN detector compared to the current plastic scintillator cells. There is potential for further reduction with the removal of plastics within the cell, which will need to be explored in future work. A third important parameter in choosing the best detection technique for radioxenon is the resolution of the electron detection. While the resolution is important in determining the minimum detectable concentration, it plays a larger role in source identification when there is a visible signal. The Silicon PIN diodes generated improved resolution over a similar plastic scintillator cell. With the improved resolution, it becomes easier to distinguish the radioxenon isomers ( 133m Xe and 131m Xe) from the 133 Xe beta continuum background. With the beta background from 133 Xe ever present with the detection of the isomers, the improved resolution proves vital in calculating the ratios of the three isotopes. With an accurate measurement of the isotopic ratios, the anthropogenic sources of radioxenon (medical isotope production and nuclear reactors) can be more accurately distinguished. Based on the results shown within this report, a Si PIN beta cell shows the potential to aid in the operation and discriminating power of the IMS for the CTBTO. However, there are a number of issues that need attention before a detector of this design would be reliable enough for field operations in the IMS. Issues that need develop include, but are not limited to: studying the robustness of the design in field conditions, eliminating or minimizing the noise and variability of individual Si detector elements, understanding the long-term gain stability of the Si detectors, and reducing the non-Si materials within the cell (i.e. the plastic housing).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of ATR-2 Irradiation to High Fluence on Nine RPV Surveillance Materials

The reactor pressure vessel (RPV) in a light-water reactor (LWR) represents the first line of defense against a release of radiation in case of an accident. Thus, regulations that govern the operation of commercial nuclear power plants require conservative margins of fracture toughness, both during normal operation and under accident scenarios. In the unirradiated condition, the RPV has sufficient fracture toughness such that failure is implausible under any postulated condition, including pressurized thermal shock (PTS) in pressurized water reactors (PWR). In the irradiated condition, however, the fracture toughness of the RPV may be severely degraded, with the degree of toughness loss dependent on the radiation sensitivity of the materials. The available embrittlement predictive models and our present understanding of radiation damage are not fully quantitative, and do not treat all potentially significant variables and issues, particularly considering extension of operation to 80y.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Non-Invasive Acoustic-Based Monitoring of Heavy Water and Uranium Process Solutions

This presentation includes slides on Project Goals; Heavy Water Production Monitoring: A New Challenge for the IAEA; Noninvasive Measurements in SFAI Cell; Large Scatter in Literature Values; Large Scatter in Literature Values; Highest Precision Sound Speed Data Available: New Standard in H/D; ~400 pts of data; Noninvasive Measurements in SFAI Cell; New funding from NA241 SGTech; Uranium Solution Monitoring: Inspired by IAEA Challenge in Kazakhstan; Non-Invasive Acoustic-Based Monitoring of Uranium in Solutions; Non-Invasive Acoustic-Based Monitoring of Uranium in Solutions; and finally a summary.

47 OTHER INSTRUMENTATION↗

Arc Parameter Modeling (Arc Breakdown Experiments and Modeling: Confined Geometries and Alternate Gap Materials)

Sandia Nationa.l Laboratories (SNL) and The Boeing Company (Boeing) collaborated on this PTS to develop the capability to predict thermal and electrical characteristics of short arcs that may appear in equipment subjected to transient currents of hundreds or thousands of amperes. The final tasks of this CRADA included experiments and computer simulations used to investigate the effect of an arc breakdown between two planar electrodes and confined by various potting materials. The arc is generated by a current waveform with a rise of 8 μs and a 20 μs fall time. Voltage, current and light emissions are recorded. The developing shock wave is observed with an optical fiber embedded in the potting material and recorded using a photonic Doppler velocimetry (PDV) diagnostic system. The experiments were modeled using the ALEGRA-MHD simulation code and comparisons are made between the experiments and simulations. This product contains Protected CRADA Information which was produced December 2015 under CRADA No. 1651. l 5 and is not to be further disclosed for a period of 5 years from the date it was produced except as expressly provided for in the CRADA. Further dissemination only as authorized by the originating partners: the Boeing Company and Sandia National Laboratories Radiation Sciences Center, or higher U.S. Department of Energy programmatic authority. Please note that the project leads from both SNL and Boeing have all retired or left for other reasons at the time of the creation of this document. The final project manager collected information for this document from the final proposal and the final report.

36 MATERIALS SCIENCE↗

High-resolution time-resolved experiments on mixing and entrainment of buoyant jets in stratified environments

Fluid jets interacting with a stratified layer play an important role in the safety of several reactor designs. In the containment of nuclear power plants, fluid jets dominate the transport and mixing of gaseous species and consequent hydrogen distribution in case of a severe accident. The mixing phenomena in the containment are driven by buoyant high-momentum injections (jets) and low momentum injection plumes. Mixing near the postulated break is initially dominated by high flow velocities. Plumes with moderate flow velocities are instead relevant in the break compartment during the long-term pressurization phase, or in any of the apertures between two connected compartments if the mass flows are sufficiently high and the density differences between efflux and ambient are sufficiently low. Phenomena of interest include free plumes (as produced by the efflux from the break compartment in a larger room or directly from a break flow), wall plumes (such those produced by low mass flows through inter-compartment apertures), and propagating stratification fronts in the ambient (for any stably stratified conditions). These phenomena have been highly ranked about nuclear reactor design, especially regarding of safety protocols. During a Pressurized Thermal Shock (PTS) scenario, the interaction between the cold ECCS injection plume and the stratified fluid present in the cold (or hot) leg is important in order to determine the temperature at the time-dependent temperature at the inlet of the reactor pressure vessel (RPV) and the potential to cause a thermal shock on the RPV wall. In sodium-cooled fast reactors (SFRs), core channels are typically hydro-dynamically isolated so that there exists a considerable temperature variation at the exit of adjacent fuel assemblies. All the above phenomena are characterized by the interaction of buoyant jets with the stratified flow. In stratified layers baroclinic forces create significant redistribution of turbulent kinetic energy and scales, which leads to anisotropy. This important physical phenomenon is highly three dimensional and is challenging to capture even with high-fidelity CFD simulations, due in part to lack of sufficiently resolved validation data. Furthermore, the experimental data available in the open literature do not feature the level of fidelity needed for an extensive validation of turbulence models in lower order CFD. To shed new lights into the crucial phenomena object of the present research project, it was proposed to conduct coordinated experiments and simulations at the University of Michigan and the George Washington University. The project has resulted in an experimental database of high-resolution time-resolved measurements of jets in uniform and stratified environments. The novel experimental data will be used to validate computational fluid dynamic (CFD) codes, including both Large Eddy Simulations (LES) and unsteady Reynolds-averaged Navier-Stokes equations (URANS) methodologies. In the Experimental and Multiphase flow (ECMF) laboratory at Univerisity of Michigan, we built two experimental facilities to investigate also the effect of scaling. The first facility, DESTROJER (DEnsity Stratified Turbulent ROund free Jet ExpeRiment), featuring a contoured jet nozzle with a diameter of D=12.7mm and a 1m×1m×1m cubic tank, which is made of acrylic glass for optical access. The ratio between the tank width and the nozzle diameter is equal to 78, which ensures that there is no direct interaction between the jet and the side walls. A second, modular experimental facility, features three different tank sizes of size 10×10×30, 20×20×30, 30×30×30 cm3 respectively (all tanks have the same height of 30 cm), and a jet diameter of 2mm. For the modular facility, tank-to-nozzle ratio of 50, 100, and 150 are obtained respectively. Experiments with different-density jet impactions and sharp interface with a density difference of 3.16% In the Laboratory at George Washington University, complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microlfuidic Component Development

908 Devices Inc. (908 Devices) had proposed to meet Defense Threat Reduction Agency (DTRA) requirements for a portable chemical vapor detector system, by coupling their high-pressure ion trap mass spectrometer to a microfabricated gas chromatography column (μGC). Sandia National Laboratories (SNL’s) role under this Cooperative Research and Development Agreement (CRADA) Project Task Statement (PTS) was to provide silicon μGC die (of two design variants), and μPC die (also of two variants) for testing and integration by the CRADA partners. These design variants were fabricated and delivered by SNL in Project Year 1. In Project Year 2, SNL personnel have advised 908 Devices personnel regarding operation and test of μGC and μPC components, as well as integration of these components into a complete chemical analysis system.

47 OTHER INSTRUMENTATION↗

Silicon Photonics for Government Applications

The purpose of the PTS was to jointly develop integrated photonics for use in Lockheed Martin Corporation's (LMC's) applications. Principally, Sandia National Laboratories (SNL) assisted LMC with silicon photonics designs and fabricated and delivered silicon photonics devices and sub-systems realizing those designs for LMC to test and evaluate. The benefits of using silicon photonics in these applications is lower size, weight, power, and cost for U.S. defense systems.

42 ENGINEERING↗

Algal Predator and Pathogen Signature Verification

The purpose of this PTS was to conduct work with ASU, specifically to further develop Spectroradiometricbased technology that has potential to function as early warning of the active presence of predators and pathogens in outdoor algal ponds. Chlorella sorokiniana and the pathogen, Vampirovibrio chlorellavorus were selected for investigation because they had previously been implicated in several pond crashes at ASU's Arizona Center for Algal Technology and Innovation (AzCATI). Sandia conducted small-scale laboratory experiments comparing control and infected cultures of C. sorokiniana. Spectrally-resolved reflectivity data, as well as optical density, and pulse amplitude modulated fluorescence (PAM) were collected and analyzed to identify the spectral response of active V. chlorellavorus infection. The results of this limited, yet robust, experiment confirmed the initial hypothesis that signature V. chlorellavorus infection of C. sorokiniana could be identified based on the presence of a chlorophyll metabolites generated when the algal chlorophyll is degraded by the pathogen.

59 BASIC BIOLOGICAL SCIENCES↗

Algal Cultivation Growth Dynamic Modeling and Analysis

The purpose of this PTS was for Sandia National Laboratories (Sandia) to conduct collaborative research with Arizona Board of Regents for and on behalf of Arizona State University (ASU) to further develop algae growth and computational fluid dynamics (CFO) models that can predict and optimize pond design and cultivation methods to improve algal yield in outdoor algal ponds.

59 BASIC BIOLOGICAL SCIENCES↗

Development of the Ultimate One-Dimensional Time to Explosion (UODTX) Apparatus

With recent advancements in experimental capabilities and worldwide improvement of digital data acquisition and control, there is sufficient justification to develop a new version of the One Dimensional Time to eXplosion (ODTX) system to allow for additional diagnostics and improved control to increase sample throughput and increase the adaptability of future experiments. The legacy ODTX system was designed to measure time to explosion (TTX) for a given temperature, which it does well, but it was not equipped to handle the recent experimental advances of Pressure-ODTX (PODTX) and Composition-ODTX (CODTX). PODTX involves fielding a pressure transducer as an additional diagnostic and applying arbitrary heating-profiles to the system anvils. CODTX furthers this concept by including in-situ gas-composition analysis via infrared (IR) absorption techniques with plans to extend CODTX to solid composition detection and in-situ mass spectrometry (MS). The legacy ODTX system was not built with these experiments in mind and performing them involves substantial modifications and downtime to the existing machine. Developing a standalone system that can perform all C/P/ODTX experiments and is adaptable to unconceived experiments would allow for the continued use of ODTX as a work-horse for Small Scale Safety Testing (SSST), but also provide a testbed for new explosive safety research. This system would ultimately be housed in the neighboring ODTX cell and would live at the High Explosive Application Facility (HEAF) until the end of its service life. HEAF, Chemistry, and Engineering would be the primary stakeholders for the system’s design as they all have experiments that they want to perform. Engineering would be responsible for the system development and would work closely with HEAF to ensure that the system is built with high explosive (HE) safety in mind. By the end of development and after product realization, HEAF/Chemistry would be the system owner, operator, and primary user. The proposed system design is highly influenced by the existing ODTX design. The system will have load frame to support the experiment, anvils to confine the explosive, and some means of applying confining pressure. The samples will be able to be heated and cooled through the confining the anvils. The biggest change from the legacy design is the ability to add diagnostics to the experiment as needed: thermocouples (TCs), resistance temperature detectors (RTDs), pressure transducers (PTs), infrared transmittance/absorbance (IR), mass spectrometry (MS), strain gages (SGs), photonic doppler velocimeter (PDV), as well as arbitrary 4-20 mV signals and +/- 10 VDC signals. The current design does not allow for flexibility in that respect and is hardwired with a few diagnostic channels. The onus will fall on designing a load frame that can support system modifications as well as a data acquisition system that can handle the multitude of signal types.

36 MATERIALS SCIENCE↗

Algal Cultivation Growth Dynamic Modeling and Analysis

The purpose of this PTS was for Sandia National Laboratories (Sandia) to conduct collaborative research with Arizona Board of Regents for and on behalf of Arizona State University (ASU) to further develop algae growth and computational fluid dynamics (CFO) models that can predict and optimize pond design and cultivation methods to improve algal yield in outdoor algal ponds.

Gharagozloo, Patricia↗

Algal Predator and Pathogen Signature Verification

The purpose of this PTS was to conduct work with Arizona State University (ASU), specifically to further develop Spectroradiometric-based technology that has potential to function as early warning of the active presence of predators and pathogens in outdoor algal ponds. Chlorella sorokiniana and the pathogen, Vampirovibrio chlorellavorus were selected for investigation because they had previously been implicated in several pond crashes at ASU’s Arizona Center for Algal Technology and Innovation (AzCATI). Sandia conducted small-scale laboratory experiments comparing control and infected cultures of C. sorokiniana . Spectrally-resolved reflectivity data, as well as optical density, and pulse amplitude modulated fluorescence (PAM) were collected and analyzed to identify the spectral response of active V. chlorellavorus infection. The results of this limited, yet robust, experiment confirmed the initial hypothesis that signature V. chlorellavorus infection of C. sorokiniana could be identified based on the presence of a chlorophyll metabolites generated when the algal chlorophyll is degraded by the pathogen.

Timlin, Jerilyn↗

Ultra-Sensitive Measurements of Large-Volume Radioxenon Samples Using an Ultra-Low-Background Proportional Counter (ULBPC) (Final Report)

This project investigated the feasibility of analyzing radioxenon samples in much larger quantities than currently used by the International Monitoring System (IMS). There is interest within the PTS and the international community in the ability to obtain xenon samples using the output of industrial oxygen plants, which could provide samples that are larger by three orders of magnitude, or more, than those currently provided by IMS stations. Such samples would best be analyzed using internal-source gas proportional counters, though the details of that approach and its sensitivity and limits were previously not examined. This report details the outcomes of a task designed to 1) analyze xenon radioisotope data collected previously via internal-source gas proportional counting and 2) collect additional gas proportional counter measurements to determine feasible gas blends for large volume xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint Actinide Shock Physics Experimental Research (JASPER): System Design Requirements: Trigger Unit

One of the key systems required for the Joint Actinide Shock Physics Experimental Research (JASPER) facility is the timely triggering of the Prompt System (PS). The Trigger Unit (TU) is the critical component that determines when the PS is to be triggered. There are two redundant TUs within the JASPER system, and each TU creates three redundant triggers for the PS. In this fashion, the Prompt Trigger System (PTS) can suffer the loss of one sensor, as well as the loss of one TU, and still function correctly. The TU is designed to receive signals from five separate sensors along the flight of the projectile on its way to the target. The TU uses three pairs of these detectors to create a trigger pulse at the appropriate time, based on the actual velocity of the projectile as it passes between the two sensors.

42 ENGINEERING↗

Substation Secondary Asset Health Monitoring and Management System (SSHM)

Electric Power Group, LLC (EPG) was awarded DOE OE0000850 to design, develop, and demonstrate a real-time software application for substation secondary equipment health monitoring and management at host utility American Electric Power (AEP), a cost share partner. This project addresses the need for monitoring substation equipment health and providing operators with tools to identify and take pre-emptive action to avoid catastrophic equipment failure. By monitoring synchrophasor data in real time, data anomalies that indicate potential asset failure can be detected and alerts can be sent to operators in time to take corrective actions. EPG developed two data driven algorithms to identify abnormal equipment signature patterns as well as a method using substation linear state estimation (SLSE). The software has been deployed on hardened PC’s and tested and validated for cost share partner AEP’s substations - 138kV and 765 kV. The SSHM software has been accepted by AEP and final demonstration of DOE - OE0000850 for AEP and DOE was successfully completed on March 17th, 2020. EPG developed the Substation Secondary Asset Health Monitoring (SSHM) Platform to analyze equipment failure signatures in PMU data and alert substation personnel when pre-emptive inspection, repairs and other actions are warranted to prevent potential catastrophic failures. This is the first system that automatically monitors the health of substation secondary assets and alerts users to emerging failures using synchrophasor measurements. SSHM uses high resolution PMU data from PTs, CTs, and CCVTs to analyze equipment signatures and identify anomalies that are precursor indicators of potential equipment failure. When an anomaly is detected, there is a likelihood of potential failure of monitored equipment, the system alerts the user with visual alarms including alarm trend charts and indicator lights on a oneline diagram of the substation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Silicon Tetrafluoride Vapor Pressure Study

The vapor pressure (VP) of silicon tetrafluoride (SiF4) was evaluated using three different cryogenic cold baths and multiple pressure transducers (PTs). Through this experiment, the known range of VP has been extended to a low temperature of 122 K. A functional relationship for the VP has been developed for the range between 122 and 159.6 K. This relationship was also used to estimate a VP value at 88 K, which was below observable levels with a 0.1 torr gauge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗