Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particulate Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Effects of Contamination Upon the Performance of X-Ray Telescopes

Particulate and molecular contamination can each impact the performance of x-ray telescope systems. Furthermore, any changes in the level of contamination between on-ground calibration and in-space operation can compromise the validity of the calibration. Thus, it is important to understand the sensitivity of telescope performance, especially the net effective area and the wings of the point spread function to contamination. Here, we quantify this sensitivity and discuss the flow-down of science requirements to contamination-control requirements. As an example, we apply this methodology to the International X-ray Observatory (IXO), currently under joint study by ESA, JAXA, and NASA.

O'Dell, Stephen L.↗

Transforming any Facility for Meeting Strict Cleanliness Requirements

Over the life of the James Webb Space Telescope (JWST), Integration & Test (I&T) has taken place in areas that needed considerable work to make the facility itself and/or the protocols used while working in the rooms suitable to meet JWST percent area coverage (PAC) and molecular accumulation requirements. In addition to normal particulate matter, JWST had a uniquely significant challenge: fibers! Fibers not only cause much higher PAC levels, but they also risk damaging the angstrom sized Near Infrared Spectrometer (NIRSpec) microshutter array (MSA), which is critical to NIRSpec instrument performance. The primary emphasis of this paper is to address particulate and fiber contamination. The success of the JWST mission required effective cleanrooms, protocols, and mitigations in non-cleanroom areas that were pressed into service to house contamination-sensitive optics and scientific instruments. Some presented profound challenges. These included: NASA’s 60-year-old Johnson Space Center (JSC) Chamber A, which had never been used for anything contamination-sensitive, and the European tropical launch facilities, which were designed to meet International Standard Organization (ISO) Class 8 processing for communication satellites. The final challenge for JWST, as if to stare us in the face and say, “I dare you to try and make me clean enough,” was preparing the 4 areas in the Centre Spatial Guyanais (CSG) Final Assembly Building (BAF) located in French Guiana, a building in which one entire side opens for Ariane 5 rocket ingress and egress. This paper will describe our initial evaluation processes and the actual work undertaken to transform even the most challenging areas into first class cleanrooms that met JWST particulate and fiber requirements.

James Webb Space Telescope↗

Molecular contamination and the calibration of AXAF

By the end of this decade, the two missions comprising the Advanced X-ray Astrophysics Facility (AXAF) will become the X-ray component of NASA's Great Observatories. In order to meet some of the ambitious scientific objectives, the AXAF team plans to calibrate the telescopes and instruments to an accuracy of a few percent. Particulate and molecular contamination potentially limit this precision, because they would likely change between ground calibration and orbital operation. To avoid this requires careful control over procedures affecting the coated optical surfaces, to ensure that neither particulate nor molecular contamination compromise the calibration. In particular, the fractional areal coverage by particulates or condensed droplets must be less than 0.005 projected onto the aperture plane; the thickness of any molecular film must be less than a few tens of angstrom.

Elsner, R. F.↗

Integrated Real Time Contamination Monitor IRTCM

Engineering and design work was performed on a monitoring device for particulate and gas contamination to be used in the space shuttle cargo area during launch at altitudes up to 50 km and during return phases of the flight. The gas sampling device consists of ampules filled with specific absorber materials which are opened and/or sealed at preprogrammed intervals. The design eliminates the use of valves which, according to experiments, are never sealing properly at hard vacuum. Methods of analysis including in-flight measuring possibilities are discussed.

Luttges, W. E.↗

Estimated Environmental Exposures for MISSE-3 and MISSE-4

Describes the estimated environmental exposure for MISSE-2 and MISSE-4. These test beds, attached to the outside of the International Space Station, were planned for 3 years of exposure. This was changed to 1 year after MISSE-1 and -2 were in space for 4 years. MISSE-3 and -4 operate in a low Earth orbit space environment, which exposes them to a variety of assaults including atomic oxygen, ultraviolet radiation, particulate radiation, thermal cycling, and meteoroid/space debris impact, as well as contamination associated with proximity to an active space station. Measurements and determinations of atomic oxygen fluences, solar UV exposure levels, molecular contamination levels, and particulate radiation are included.

Finckenor, Miria M.↗

Payload/orbiter contamination control requirement study, volume 1, exhibit A

This study is to identify and quantify the expected molecular and particulate on orbit contaminant environment for selected shuttle payloads as a result of major spacelab and shuttle orbiter contaminant sources. This investigation reviews individual payload susceptibilities to contamination, identifies the combined induced environment, identifies the risk of spacelab/payload critical surface(s) degradation, and provides preliminary contamination recommendations. It also establishes limiting factors which may depend upon operational activities associated with the payloads, spacelab, and the shuttle orbiter interface or upon independent payload functional activities.

Bareiss, L. E.↗

Optical contamination measurements on early Shuttle missions

Two camera/photometers were included as part of the Induced Environment Contamination Monitor on STS-2,-3,-4, and -9 orbital missions to record photographically Shuttle-induced particulate and background contamination. The cameras collected stereoscopic data continuously during the on-orbit phases of these missions making exposures every 150 s. The results recorded throughout a 32-deg field-of-view indicate high particle concentrations during early mission operations. These decay to a quiescent rate of 500 particles of greater than 10-micron radius observed per orbit. Preliminary size and velocity distributions of measured particles are presented as are measurements of background brightness due to unresolved particles in the visible spectral region.

Clifton, K. Stuart↗

Method for the Collection, Gravimetric and Chemical Analysis of Nonvolatile Residue (NVR) on Surfaces

Nonvolatile residue (NVR), sometimes referred to as molecular contamination is the term used for the total composition of the inorganic and high boiling point organic components in particulates and molecular films deposited on critical surfaces surrounding space structures, with the particulate and NVR contamination originating primarily from pre-launch operations. The "nonvolatile" suggestion from the terminology NVR implies that the collected residue will not experience much loss under ambient conditions. NVR has been shown to have a dramatic impact on the ability to perform optical measurements from platforms based in space. Such contaminants can be detected early by the controlled application of various detection techniques and contamination analyses. Contamination analyses are the techniques used to determine if materials, components, and subsystems can be expected to meet the performance requirements of a system. Of particular concern is the quantity of NVR contaminants that might be deposited on critical payload surfaces from these sources. Subsequent chemical analysis of the contaminant samples by infrared spectroscopy and gas chromatography mass spectrometry identifies the components, gives semi-quantitative estimates of contaminant thickness, indicates possible sources of the NVR, and provides guidance for effective cleanup procedures. In this report, a method for the collection and determination of the mass of NVR was generated by the authors at NASA Langley Research Center. This report describes the method developed and implemented for collecting NVR contaminants, and procedures for gravimetric and chemical analysis of the residue obtained. The result of this NVR analysis collaboration will help pave the way for Langley's ability to certify flight hardware outgassing requirements in support of flight projects such as Stratospheric Aerosol and Gas Experiment III (SAGE III), Clouds and the Earth's Radiant Energy System (CERES), Materials International Space Station Experiment - X (MISSE-X), and Doppler Aerosol Wind Lidar (DAWN).

Gordon, Keith↗

The Opera Instrument: An Advanced Curation Development for Mars Sample Return Organic Contamination Monitoring

Mars Sample Return (MSR) requires strict organic contamination control (CC) and contamination knowledge (CK) as outlined by the Mars 2020 Organic Contamination Panel (OCP). This includes a need to monitor surficial organic contamination to a ng/sq. cm sensitivity level. Archiving and maintaining this degree of surface cleanliness may be difficult but has been achieved. MSR's CK effort will be very important because all returned samples will be studied thoroughly and in minute detail. Consequently, accurate CK must be collected and characterized to best interpret scientific results from the returned samples. The CK data are not only required to make accurate measurements and interpretations for carbon-depleted martian samples, but also to strengthen the validity of science investigations performed on the samples. The Opera instrument prototype is intended to fulfill a CC/CK role in the assembly, cleaning, and overall contamination history of hardware used in the MSR effort, from initial hardware assembly through post-flight sample curation. Opera is intended to monitor particulate and organic contamination using quartz crystal microbalances (QCMs), in a self-contained portable package that is cleanroom-compliant. The Opera prototype is in initial development capable of approximately 100 ng/sq. cm organic contamination sensitivity, with additional development planned to achieve 1 ng/sq. cm. The Opera prototype was funded by the 2017 NASA Johnson Space Center Innovation Charge Account (ICA), which provides funding for small, short-term projects.

Fries, M. D.↗

Contamination control program for the Extreme Ultraviolet Explorer instruments

A contamination-control program has been instituted for the optical components of the EUV Explorer satellite, whose 80-900 A range performance is easily degraded by particulate and molecular contamination. Cleanliness requirements have been formulated for the design, fabrication, and test phases of these instruments; in addition, contamination-control steps have been taken which prominently include the isolation of sensitive components in a sealed optics cavity. Prelaunch monitoring systems encompass the use of quartz crystal microbalances, particle witness plates, direct flight hardware sampling, and optical witness sampling of EUV scattering and reflectivity.

Ray, David C.↗

Implementation of the TOMS contamination control requirements in the former USSR

The American Total Ozone Mapping Spectrometer (TOMS) was integrated with the Russian Meteor-3 spacecraft and launched on August 15, 1991. Although the TOMS instrument was sensitive to both particulate and molecular contamination, the program for Meteor-3 had not formerly addressed contamination control in ground operations. In order to accommodate the TOMS cleanliness requirements, a contamination control program was successfully established from inception at both the Meteor-3 spacecraft plant near Moscow and at the launch site in Plesetsk.

Abrams, Eve M.↗

Contamination control program results from three years of ground operations on the Extreme Ultraviolet Explorer instruments

A stringent contamination-control plan has been developed for the optical components of the Extreme Ultraviolet Explorer instruments, whose performance in the 80-900 A wavelength range is highly sensitive to particulate and molecular contamination. The contamination-control program has been implemented over the last three years during assembly, test and calibration phases of the instrument. These phases have now been completed and the optics cavities of the instruments have been sealed until deployment in space. Various approaches are discussed which have been used during ground operations to meet optics' contamination goals within the project schedule and budget. The measured optical properties of EUV witness mirrors are also presented which remained with the flight mirrors during ground operations. These were used to track optical degradation due to contamination from the cleanroom and high-vacuum test-chamber environments.

Ray, David C.↗

Preparation, verification, and operational control of a large space-environment-simulation chamber for contamination sensitive tests

A 2-year program to prepare chamber A at the NASA Manned Spacecraft Center for Apollo telescope mount thermal-vacuum tests is discussed. This program covers modification to existing chamber systems, the development of facility and chamber operating procedures, the selection of chamber cleaning and control methods, and the development and evaluation of diagnostic instrumentation. Extensive efforts to ensure a minimum contamination environment for the Apollo telescope mount test series are illustrated. Recent thermal-vacuum tests of this chamber at progressive stages of cleanliness have demonstrated the success achieved in reducing the particulate and molecular contamination levels of the basic chamber interior.

Visentine, J. T.↗

Contamination design of a Scientific Instrument Protective Enclosure for the Hubble Space Telescope Servicing Mission

A Scientific Instrument Protective Enclosure (SIPE) was designed to accommodate second generation science instruments (SIs) for the Hubble Space Telescope (HST) First Servicing Mission (FSM). One of the main design drivers for the SIPE is to provide a protective environment for the SIs against particulate and molecular contaminants that pose a viable threat to the SI performance. The focus of this paper will detail the methodology incorporated in the design of the SIPE to provide a controlled environment for SI protection at the launch site, during pre-launch/launch activities, and during on-orbit operations in the Shuttle bay.

Hedgeland, Randy J.↗

A Study of Space Station Contamination Effects

A workshop was held with the specific objective of reviewing the state-of-knowledge regarding Space Station contamination, the extent to which the various categories of contamination can be predicted, and the extent to which the predicted levels would interfere with onboard scientific investigations or space station functions. The papers presented at the workshop are compiled and address the following topics: natural environment, plasma electromagnetic environment, optical environment, particulate environment, spacecraft contamination, surface physics processes, laboratory experiments and vented chemicals/contaminants.

Torr, M. R.↗

A Kinetic Model of the Long-Term Corrosion of Glass-Ceramic Materials

Multiphase waste forms show promise for increased waste loading and for the ability to dispose of contaminated solid and particulate waste through direct densification. However, achieving predictive capability for long-term durability of multiphase waste forms, and thus assessing their possible deployment, requires expanding the current, limited knowledge base. Here, we describe the development of a corrosion model of a two-phase waste form consisting of crystals of known volume fraction embedded in a glass matrix. This model accounts for the dissolution of both the crystalline and glass phases as well as the hydration of the glass phase through an ion exchange reaction. Because of the large difference in solubility between the two phases, the reactive surface of the crystalline phase is a function of the extent of dissolution of the glass phase in this model. Model parameterization was performed using corrosion data, such as from single-pass flow-through tests, for the individual phases. The parameterized corrosion model was evaluated against static dissolution test data for a glass-ceramic multiphase waste form. This evaluation demonstrated the model’s ability to reproduce the time-dependent release of key tracers of glass and crystalline phase dissolution. Hence, the development of a kinetic model provides a pathway for long-term durability predictions and thus the use of multiphase waste forms in nuclear cleanup missions.

Kerisit, Sebastien N.↗

Ionic liquid mediated one-step perpendicular assembly in block copolymer thin films for ultrafiltration membrane applications

The rapid rise of oil and gas, petrochemical, food processing, and pharmaceutical industries has added a complex mixture of contaminants like oil, particulates, metals, and other organic compounds to wastewater. Multipurpose membranes with precise pore structure can offer a solution to this problem and block copolymers (BCP) can be used to achieve such structures. Achieving vertical assembly of BCP domains provides a perfect template for developing uniform through film channels for separation and transport of material, besides being useful for the rectification of defects in photolithography patterns. Producing such morphologies may require extensive film/substrate processing and is not always feasible for scale-up. With this article, we demonstrate a facile solution casting method to induce vertical domain assembly in as-cast diblock copolymer thin films in the presence of an ionic liquid (IL) additive that preferentially segregates to one block and neutralizes interfacial interactions. We also show the tunability of domain sizes by controlling the additive concentration. These vertically aligned morphologies are important for the development of next-generation lithographic techniques and form excellent templates for ultrafiltration membranes with uniform pore sizes. In conclusion, this article demonstrates how IL additives can be used to obtain stable non-equilibrium morphologies in as-cast BCP films and the effect of BCP molecular mass, block volume fractions, and IL content on self-assembly.

59 BASIC BIOLOGICAL SCIENCES↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗