Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Real-time moving platform management system

Systems and methods are disclosed including a moving platform system suitable for mounting and use on a moving platform for communicating in real-time, comprising: a position system monitoring location of the moving platform and generating a sequence of time-based position data; a non-line of sight communication system; a high-speed line of sight communication system; and a computer system monitoring an availability of the non-line of sight communication system and the high-speed line of sight communication system and initiating connections when the non-line of sight communication system and the high-speed line of sight communication system are available, and receiving the sequence of time-based position data and transmitting the sequence of time-based position data via the at least one of the currently available non-line of sight communication system and the high-speed line of sight communication system.

Giuffrida, Frank D.↗

Systems and methods for augmenting a satellite based navigation system with alternative position and timing data

Various technologies pertaining to integrating a positioning or timing solution from an alternative position, navigation, or timing (PNT) system into a satellite-based-navigation system are described herein. The PNT system generates a position/timing (P/T) solution that indicates a current position or current time of the PNT system. The P/T solution is provided as input to a simulation of a satellite constellation of the satellite-based-navigation system, and a constellation signal is generated based on the simulation and the P/T solution. The constellation signal is formatted according to a navigation signal format of the satellite-based-navigation system such that when the constellation signal is provided to a receiver of the satellite-based-navigation system, the receiver computes a P/T solution that indicates the current position or the current time identified by the PNT system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Climatically driven changes in primary production propagate through trophic levels

Abstract Climate and land‐use change are the major drivers of global biodiversity loss. Their effects are particularly acute for wide‐ranging consumers, but little is known about how these factors interact to affect the abundance of large carnivores and their herbivore prey. We analyzed population densities of a primary and secondary consumer (mule deer, Odocoileus hemionus , and mountain lion, Puma concolor ) across a climatic gradient in western North America by combining satellite‐based maps of plant productivity with estimates of animal abundance and foraging area derived from Global Positioning Systems telemetry data (GPS). Mule deer density exhibited a positive, linear relationship with plant productivity ( r 2 = 0.58), varying by a factor of 18 across the climate‐vegetation gradient (range: 38–697 individuals/100 km 2 ). Mountain lion home range size decreased in response to increasing primary productivity and consequent changes in the abundance of their herbivore prey (range: 20–450 km 2 ). This pattern resulted in a strong, positive association between plant productivity and mountain lion density ( r 2 = 0.67). Despite varying densities, the ratio of prey to predator remained constant across the climatic gradient (mean ± SE = 363 ± 29 mule deer/mountain lion), suggesting that the determinacy of the effect of primary productivity on consumer density was conserved across trophic levels. As droughts and longer term climate changes reduce the suitability of marginal habitats, consumer home ranges will expand in order for individuals to meet basic nutritional requirements. These changes portend decreases in the abundance of large‐bodied, wide‐ranging wildlife through climatically driven reductions in carrying capacity, as well as increased human–wildlife interactions stemming from anthropogenic land use and habitat fragmentation.

Stoner, David C.↗

GPS signal loss in the wide area monitoring system: Prevalence, impact, and solution

The phasor measurement unit (PMUs), equipped with Global Positioning System (GPS) receivers for precise time synchronization, provides measurements of voltage and current phasors at different nodes of the wide area monitoring system. However, GPS receivers are likely to lose satellite signals due to various unpredictable factors. The prevalence of GPS signal loss (GSL) on PMUs is first investigated using real PMU data. The historical GSL events are extracted from a phasor data concentrator (PDC) and FNET/GridEye server. The correlation between GSL and time, spatial location, solar activity are explored via comprehensive statistical analysis. Furthermore, the impact of GSL on phasor measurement accuracy has been studied via experiments. Finally, several potential solutions to mitigate the impact of GSL on PMUs are discussed and compared.

47 OTHER INSTRUMENTATION↗

SU-F-P-23: Setup Uncertainties for the Lung Stereotactic Body Radiation Therapy

Purpose: The Exactrack X-ray system with six degree-of-freedom (6DoF) adjustment ability can be used for setup of lung stereotactic body radiation therapy. The setup uncertainties from ExacTrack 6D system were analyzed. Methods: The Exactrack X-ray 6D image guided radiotherapy system is used in our clinic. The system is an integration of 2 subsystems: (1): an infrared based optical position system and (2) a radiography kV x-ray imaging system. The infrared system monitors reflective body markers on the patient’s skin to assistant in the initial setup. The radiographic kV devices were used for patient positions verification and adjustment. The position verification was made by fusing the radiographs with the digitally reconstructed radiograph (DRR) images generated by simulation CT images using 6DoF fusion algorithms. Those results were recorded in our system. Gaussian functions were used to fit the data. Results: For 37 lung SBRT patients, the image registration results for the initial setup by using surface markers and for the verifications, were measured. The results were analyzed for 143 treatments. The mean values for the lateral, longitudinal, vertical directions were 0.1, 0.3 and 0.3mm, respectively. The standard deviations for the lateral, longitudinal and vertical directions were 0.62, 0.78 and 0.75mm respectively. The mean values for the rotations around lateral, longitudinal and vertical directions were 0.1, 0.2 and 0.4 degrees respectively, with standard deviations of 0.36, 0.34, and 0.42 degrees. Conclusion: The setup uncertainties for the lung SBRT cases by using Exactrack 6D system were analyzed. The standard deviations of the setup errors were within 1mm for all three directions, and the standard deviations for rotations were within 0.5 degree.

60 APPLIED LIFE SCIENCES↗

2014-2015 Puget Sound Regional Travel Study

The 2014-2015 Puget Sound Regional Travel Study collected information about household and individual travel patterns for residents throughout a four-county region in Washington State. Study results were used to update the region's travel and land-use models and to calibrate local traffic and travel models. The study also helped the Puget Sound Regional Council (PSRC) and its regional partners develop plans that accommodate the diverse travel needs and preferences of residents. The Resource Systems Group administered the study on behalf of PSRC. Global positioning system (GPS)-equipped smartphones were used to provide data pertaining to the daily travel of 547 individual participants. Because the region's university students may have been underrepresented in the initial 2014 household travel study, the PSRC added a college-population travel survey in fall 2014. In spring 2015, a second household data collection effort was conducted to increase the frequency of data collection and to collect GPS data as well as a sample of longitudinal data from households that completed the 2014 survey.

1Hz data↗

Synchrophasor measurement method for power systems

A synchrophasor measurement method for a device configured to take synchronized measurements in a power system is provided. The synchrophasor measurement method includes receiving global positioning system (GPS)-synchronized samples of a signal sensed by the device from the power system; determining a level of distortion of the signal; selecting, based on the level of distortion, a computation method, the computation method being one of an improved zero-crossing (IZC) method and an enhanced phase-lock-loop (EPLL) method; performing the selected computation method to determine at least one parameter of the signal at a reporting frequency, which is at least twice a line frequency of the power system; and outputting, at the reporting frequency, the at least one parameter to an operator of the power system to allow the operator to perform at least one of a monitoring and a controlling of at least one element of the power system.

Yao, Wenxuan↗

Rapid deployable global sensing hazard alert system

A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.

97 MATHEMATICS AND COMPUTING↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of a Robotic 6-Degree of Freedom Treatment Couch for Frameless Radiosurgery

Purpose: To evaluate the added value of 6-degree of freedom (DOF) patient positioning with a robotic couch compared with 4DOF positioning for intracranial lesions and to estimate the immobilization characteristics of the BrainLAB frameless mask (BrainLAB AG, Feldkirchen, Germany), more specifically, the setup errors and intrafraction motion. Methods and Materials: We enrolled 40 patients with 66 brain metastases treated with frameless stereotactic radiosurgery and a 6DOF robotic couch. Patient positioning was performed with the BrainLAB ExacTrac stereoscopic X-ray system. Positioning results were collected before and after treatment to assess patient setup error and intrafraction motion. Existing treatment planning data were loaded and simulated for 4DOF positioning and compared with the 6DOF positioning. The clinical relevance was analyzed by means of the Paddick conformity index and the ratio of prescribed isodose volume covered with 4DOF to that obtained with the 6DOF positioning. Results: The mean three-dimensional setup error before 6DOF correction was 1.91 mm (SD, 1.25 mm). The rotational errors were larger in the longitudinal (mean, 0.23 Degree-Sign ; SD, 0.82 Degree-Sign ) direction compared with the lateral (mean, -0.09 Degree-Sign ; SD, 0.72 Degree-Sign ) and vertical (mean, -0.10 Degree-Sign ; SD, 1.03 Degree-Sign ) directions (p < 0.05). The mean three-dimensional intrafraction shift was 0.58 mm (SD, 0.42 mm). The mean intrafractional rotational errors were comparable for the vertical, longitudinal, and lateral directions: 0.01 Degree-Sign (SD, 0.35 Degree-Sign ), 0.03 Degree-Sign (SD, 0.31 Degree-Sign ), and -0.03 Degree-Sign (SD, 0.33 Degree-Sign ), respectively. The mean conformity index decreased from 0.68 (SD, 0.08) (6DOF) to 0.59 (SD, 0.12) (4DOF) (p < 0.05). A loss of prescribed isodose coverage of 5% (SD, 0.08) was found with the 4DOF positioning (p < 0.05). Half a degree for longitudinal and lateral rotations can be identified as a threshold for coverage loss. Conclusions: With a mask immobilization, patient setup error and intrafraction motions need to be evaluated and corrected for. The 6DOF patient positioning with a 6DOF robotic couch to correct translational and rotational setup errors improves target positioning with respect to treatment isocenter, which is in direct relation with the clinical outcome, compared with the 4DOF positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement‐based correlation approach for power system dynamic response estimation

Understanding power system dynamics is essential for online stability assessment and control applications. Global positioning system‐synchronised phasor measurement units and frequency disturbance recorders (FDRs) make power system dynamics visible and deliver an accurate picture of the overall operation condition to system operators. However, in the actual field implementations, some measurement data can be inaccessible for various reasons, for example, most notably failure of communication. In this study, a measurement‐based approach is proposed to estimate the missing power system dynamics. Specifically, a correlation coefficient index is proposed to describe the correlation relationship between different measurements. Then, the auto‐regressive with exogenous input identification model is employed to estimate the missing system dynamic response. The US Eastern Interconnection is utilised in this study as a case study. The robustness of the correlation approach is verified by a wide variety of case studies as well. Finally, the proposed correlation approach is applied to the real FDR data for power system dynamic response estimation. The results indicate that the correlation approach could help select better input locations and thus improve the response estimation accuracy.

Bai, Feifei↗

Auxiliary Drives for Automated Assembly Systems

Basic types of auxiliary drives in automated assembly systems are compared in terms of generalized characteristics. Regulation of the pneumatic drive by means of servomechanical positioning systems is considered. Diagrams are presented for assessment of the mean velocities and travel times of mechatronic modules in the angular positioning of loading drives on the basis of kinematic and mechanical characteristics.

42 ENGINEERING↗

Correlation between Sensor Performance, Autonomy Performance and Fuel-Efficiency in Semi-Truck Platoons

Semi-trucks, specifically class-8 trucks, have recently become a platform of interest for autonomy systems. Platooning involves multiple trucks following each n close proximity, with only the lead truck being manually driven and the rest being controlled autonomously. This approach to semi-truck autonomy is easily integrated on existing platforms, reduces delivery times, and reduces green- house gas emissions via fuel economy benefits. Level 1 SAE fuel studies were performed on class-8 trucks operating with the Auburn Cooperative Adaptive Cruise Control (CACC) system, and fuel savings up to 10-12% were seen. Enabling platooning autonomy required the use of radar, global positioning systems (GPS), and wireless vehicle-to-vehicle (V2V) communication. Poor measurements and state estimates can lead to incorrect or missing positioning data, which can lead to unnecessary dynamics and finally wasted fuel. This is especially an issue if deceleration is applied in response to a bad measurement. In this study, a faulty radar was shown to cause a greater than 5% increase in fuel consumption. The mechanism of this fuel consumption increase is investigated and applied to other types of sensor failures to indicate their potential effects on fuel economy. This analysis indicates that poor GPS signals over short time can be largely filtered out, with no real gain or loss of fuel economy. V2V communications were intentionally limited by causing interference, which resulted in dropped communication packets over a small physical area, but not an appreciable impact on fuel economy.

vehicle platooning, sensor performance, semi-auton↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

Clinical benefits of new immobilization system for hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma by helical tomotherapy

Objective: A comprehensive clinical evaluation was conducted, assessing the Body Pro-Lok immobilization and positioning system to facilitate hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma (HCC), using helical tomotherapy to improve treatment precision. Methods: Clinical applications of the Body Pro-Lok system were investigated (as above) in terms of interfractional and intrafractional setup errors and compressive abdominal breath control. To assess interfractional setup errors, a total of 42 patients who were given 5 to 20 fractions of helical tomotherapy for intrahepatic HCC were analyzed. Overall, 15 patients were immobilized using simple vacuum cushion (group A), and the Body Pro-Lok system was used in 27 patients (group B), performing megavoltage computed tomography (MVCT) scans 196 times and 435 times, respectively. Pretreatment MVCT scans were registered to the planning kilovoltage computed tomography (KVCT) for error determination, and group comparisons were made. To establish intrafractional setup errors, 17 patients with intrahepatic HCC were selected at random for immobilization by Body Pro-Lok system, undergoing MVCT scans after helical tomotherapy every week. A total of 46 MVCT re-scans were analyzed for this purpose. In researching breath control, 12 patients, randomly selected, were immobilized by Body Pro-Lok system and subjected to 2-phase 4-dimensional CT (4DCT) scans, with compressive abdominal control or in freely breathing states, respectively. Respiratory-induced liver motion was then compared. Results: Mean interfractional setup errors were as follows: (1) group A: X, 2.97 ± 2.47 mm; Y, 4.85 ± 4.04 mm; and Z, 3.77 ± 3.21 mm; pitch, 0.66 ± 0.62°; roll, 1.09 ± 1.06°; and yaw, 0.85 ± 0.82°; and (2) group B: X, 2.23 ± 1.79 mm; Y, 4.10 ± 3.36 mm; and Z, 1.67 ± 1.91 mm; pitch, 0.45 ± 0.38°; roll, 0.77 ± 0.63°; and yaw, 0.52 ± 0.49°. Between-group differences were statistically significant in 6 directions (p < 0.05). Mean intrafractional setup errors with use of the Body Pro-Lok system were as follows: X, 0.41 ± 0.46 mm; Y, 0.86 ± 0.80 mm; Z, 0.33 ± 0.44 mm; and roll, 0.12 ± 0.19°. Mean liver-induced respiratory motion determinations were as follows: (1) abdominal compression: X, 2.33 ± 1.22 mm; Y, 5.11 ± 2.05 mm; Z, 2.13 ± 1.05 mm; and 3D vector, 6.22 ± 1.94 mm; and (2) free breathing: X, 3.48 ± 1.14 mm; Y, 9.83 ± 3.00 mm; Z, 3.38 ± 1.59 mm; and 3D vector, 11.07 ± 3.16 mm. Between-group differences were statistically different in 4 directions (p < 0.05). Conclusions: The Body Pro-Lok system is capable of improving interfractional and intrafractional setup accuracy and minimizing tumor movement owing to respirations in patients with intrahepatic HCC during hypofractionated helical tomotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Accuracy Angle Generator for Angular Calibrations to Support Optical Metrology Laboratories and Light Source Facilities

The overarching vision for this project was to build the most accurate full-rotation angular positioning system in the Americas, and that goal remains. In labs performing similar work, the environment is typically closer to a clean room than an office space, like we had before the upgrades. We are now positioned to achieve our intended result with our upgraded infrastructure, system hardware, calibration techniques, and software. As detailed below, the combination of the pandemic schedule and technical challenges have set us back, but we will continue on the path toward our vision beyond the end of this Phase 2. It’s too important for us, for industry, and for the nation not to do so.

47 OTHER INSTRUMENTATION↗

Overview of recent trends and developments for BPM systems

Beam position monitoring (BPM) systems are the workhorse of beam diagnostics for almost any kind of charged particle accelerator: linear, circular or transport-lines, operating with leptons, hadrons or heavy ions. BPMs are essential for beam commissioning, accelerator fault analysis and trouble shooting, machine optics, as well as lattice measurements, and finally, for accelerator optimization, in order to achieve the ultimate beam quality. This presentation summarizes the efforts of the beam instrumentation community on recent developments and advances on BPM technologies, i.e. BPM pickup monitors and front-end electronics (analog and digital). Principles, examples, and state-of-the-art status on various BPM techniques, serving hadron and heavy ion machines, sync light synchrotron's, as well as electron linacs for FEL or HEP applications are outlined.

43 PARTICLE ACCELERATORS↗

SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many preclinical applications including focused drug delivery and thermal therapy. Funding support provided by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗