Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Scaling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Evaluation of Solid Sorbents As A Retrofit Technology for CO 2 Capture from Coal-Fired Power Plants

Through a U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) funded cooperative agreement DE-NT0005649, ADA Environmental Solutions (ADA) has begun evaluating the use of solid sorbents for CO 2 capture. The project objective was to address the viability and accelerate development of a solid-based CO 2 capture technology. To meet this objective, initial evaluations of sorbents and the process / equipment were completed. First the sorbents were evaluated using a temperature swing adsorption process at the laboratory scale in a fixed-bed apparatus. A slipstream reactor designed to treat flue gas produced by coal-fired generation of nominally 1 kWe was designed and constructed, which was used to evaluate the most promising materials on a more meaningful scale using actual flue gas. In a concurrent effort, commercial-scale processes and equipment options were also evaluated for their applicability to sorbent-based CO 2 capture. A cost analysis was completed that can be used to direct future technology development efforts.

20 FOSSIL-FUELED POWER PLANTS↗

Bench-Scale Silicone Process for Low-Cost CO 2 Capture (Final Technical and Economic Feasibility Report)

This report presents system and economic analysis for a carbon capture unit which uses an amino-silicone solvent for CO 2 capture and sequestration (CCS) in a pulverized coal (PC) boiler. The amino-silicone solvent is based on GAP-1 with tri-ethylene glycol (TEG) as a co-solvent. For comparison purposes, the report also shows results for a CCS unit based on a conventional approach using mono-ethanol amine (MEA). At a steam temperature of 395 °C (743 °F), the CCS energy penalty for amino-silicone solvent is only 30.4% which compares to a 35.9% energy penalty for MEA. The increase in COE for the amino-silicone solvent relative to the non-capture case is between 98% and 103% (depending on the solvent cost) which compares to an ~109% COE cost increase for MEA. In summary, the amino-silicone solvent has significant advantages over conventional systems using MEA.

20 FOSSIL-FUELED POWER PLANTS↗

Bench-Scale Silicone Process for Low-Cost CO 2 Capture

This report presents system and economic analysis for a carbon capture unit which uses an amino-silicone solvent for CO 2 capture and sequestration (CCS) in a pulverized coal (PC) boiler. The amino-silicone solvent is based on GAP-1 with Tri-Ethylene Glycol (TEG) as a co-solvent. The report also shows results for a CCS unit based on a conventional approach using mono-ethanol amine (MEA). Models were developed for both processes and used to calculate mass and energy balances. Capital costs and energy penalty were calculated for both systems, as well as the increase in cost of electricity. The amino-silicone solvent based system demonstrates significant advantages compared to the MEA system.

20 FOSSIL-FUELED POWER PLANTS↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture Preliminary Techno-Economic Analysis

This report presents system and economic analysis for a carbon-capture unit which uses an aminosilicone-based solvent for CO{sub 2} capture in a pulverized coal (PC) boiler. The aminosilicone solvent is a 60/40 wt/wt mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) with tri-ethylene glycol (TEG) as a co-solvent. For comparison purposes, the report also shows results for a carbon-capture unit based on a conventional approach using mono-ethanol amine (MEA). The first year removal cost of CO{sub 2} for the aminosilicone-based carbon-capture process is $46.04/ton of CO2 as compared to $60.25/ton of CO{sub 2} when MEA is used. The aminosilicone-based process has <77% of the CAPEX of a system using MEA solvent. The lower CAPEX is due to several factors, including the higher working capacity of the aminosilicone solvent compared the MEA, which reduces the solvent flow rate required, reducing equipment sizes. If it is determined that carbon steel can be used in the rich-lean heat exchanger in the carbon capture unit, the first year removal cost of CO{sub 2} decreases to $44.12/ton. The aminosilicone-based solvent has a higher thermal stability than MEA, allowing desorption to be conducted at higher temperatures and pressures, decreasing the number of compressor stages needed. The aminosilicone-based solvent also has a lower vapor pressure, allowing the desorption to be conducted in a continuous-stirred tank reactor versus a more expensive packed column. The aminosilicone-based solvent has a lower heat capacity, which decreases the heat load on the desorber. In summary, the amino-silicone solvent has significant advantages over conventional systems using MEA.

54 ENVIRONMENTAL SCIENCES↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture

This report presents system and economicanalysis for a carbon-capture unit which uses an aminosilicone-based solvent for CO₂ capture in a pulverized coal (PC) boiler. The aminosilicone solvent is a 60/40 wt/wt mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) with tri-ethylene glycol (TEG) as a co-solvent. Forcomparison purposes, the report also shows results for a carbon-capture unit based on a conventional approach using mono-ethanol amine (MEA). The first year removal cost of CO₂ for the aminosilicone-based carbon-capture process is $46.04/ton of CO₂ as compared to $60.25/ton of CO₂ when MEA is used. The aminosilicone- based process has <77% of the CAPEX of a system using MEA solvent. The lower CAPEX is due to several factors, including the higher working capacity of the aminosilicone solvent compared the MEA, which reduces the solvent flow rate required, reducing equipment sizes. If it is determined that carbon steel can be used in the rich-lean heat exchanger in the carbon capture unit, the first year removal cost of CO₂ decreases to $44.12/ton. The aminosilicone-based solvent has a higherthermal stability than MEA, allowing desorption to be conducted at higher temperatures and pressures, decreasing the number of compressor stages needed. The aminosilicone-based solvent also has a lowervapor pressure, allowing the desorption to be conducted in a continuous-stirred tank reactor versus a more expensive packed column. The aminosilicone-based solvent has a lowerheat capacity, which decreases the heat load on the desorber. In summary, the amino-silicone solvent has significant advantages overconventional systems using MEA.

Singh, Surinder↗

Development of optimum process for electron beam cross-linking of high density polyethylene thermal energy storage pellets, process scale-up and production of application qualities of material

The electron irradiation conditions required to prepare thermally from stable high density polyethylene (HDPE) were defined. The conditions were defined by evaluating the heat of fusion and the melting temperature of several HDPE specimens. The performance tests conducted on the specimens, including the thermal cycling tests in the thermal energy storage unit are described. The electron beam irradiation tests performed on the specimens, in which the total radiation dose received by the pellets, the electron beam current, the accelerating potential, and the atmospheres were varied, are discussed.

Salyer, I. O.↗

Small-scale dissipative processes in stellar atmospheres

The outer atmospheres of stars must be heated by some non-thermal energy flux to produce chromospheres and coronae. Processes are discussed which convert the non-thermal energy flux of organized, macroscopic motions into random, microscopic (thermal) motions. Recent advances in the description of the chromosphere velocity field suggest that the acoustic waves observed there transmit very little energy, and hence are probably incapable of heating the upper chromosphere and corona. The apparent failure of this long held mechanism and the growing appreciation of the importance of strong magnetic fields in the chromosphere and corona have led to hypotheses of heating by the dissipation of currents (both oscillatory and quasi-steady). This follows discoveries in laboratory and ionospheric plasmas and work on solar flares, that instabilities can concentrate currents into thin high current density filaments where they dissipate rapidly.

Leibacher, J. W.↗

The use of satellite data in understanding and predicting convective and large-scale dynamical processes

Mesoscale convective processes and how they affect and interact with mid-latitude cyclones were studied. The ageostrophic and associated vertical motion field was calculated using a highly accurate iterative method of solving the semigeostrophic omega equation. The tendencies for convective destabilization in the 850-750 mb layer due to differential geostrophic and ageostrophic advection and differential moist adiabatic ascent, were found. The spectral models of the index oscillation, one barotropic and the other baroclinic, were developed. Theoretical and observational studies of cloud streets were conducted.

Dutton, J. A.↗

Global Scale Atmospheric Processes Research Program Review

Global modeling; satellite data assimilation and initialization; simulation of future observing systems; model and observed energetics; dynamics of planetary waves; First Global Atmospheric Research Program Global Experiment (FGGE) diagnosis studies; and National Research Council Research Associateship Program are discussed.

Worley, B. A.↗

The use of satellite data in understanding and predicting convective and large-scale dynamical processes

A two-layer truncated baroclinic spectral model was developed to study the long-term evolution of disturbances to a baroclinically unstable mean flow. Topography and crudely-parameterized radiative processes were accounted for. As a result of Robert Schlaak's discovery of the underlying barotropic nature of the index oscillation as well as reviewers suggestions about the original manuscript, the model has been revised to allow for barotropic as well as baroclinic wave-mean flow interactions. The form-drag exerted by the topography on the barotropic part of the mean flow is larger than on the baroclinic part and thus researchers anticipate significant changes from the original calculations on the index oscillation when it is strongly modulated by topography. Researchers believe that since the index oscillation accounts for a significant portion of atmospheric temporal variance, the long term predictability could be improved if reliable forecasts of the index oscillation were available. Two spectral models of the index oscillation, one barotropic and the other baroclinic, have been developed. The latter allows for moisture, radiation, land-sea temperature countrasts, and energy exchanges with the underlying surface.

Dutton, J. A.↗

NASA/MSFC FY90 Global Scale Atmospheric Processes Research Program Review

Research supported by the Global Atmospheric Research Program at the Marshall Space Flight Center on atmospheric remote sensing, meteorology, numerical weather forecasting, satellite data analysis, cloud precipitation, atmospheric circulation, atmospheric models and related topics is discussed.

Leslie, Fred W.↗

A Method for Estimating Noise from Full-Scale Distributed Exhaust Nozzles

A method to estimate the full-scale noise suppression from a scale model distributed exhaust nozzle (DEN) is presented. For a conventional scale model exhaust nozzle, Strouhal number scaling using a scale factor related to the nozzle exit area is typically applied that shifts model scale frequency in proportion to the geometric scale factor. However, model scale DEN designs have two inherent length scales. One is associated with the mini-nozzles, whose size do not change in going from model scale to full scale. The other is associated with the overall nozzle exit area which is much smaller than full size. Consequently, lower frequency energy that is generated by the coalesced jet plume should scale to lower frequency, but higher frequency energy generated by individual mini-jets does not shift frequency. In addition, jet-jet acoustic shielding by the array of mini-nozzles is a significant noise reduction effect that may change with DEN model size. A technique has been developed to scale laboratory model spectral data based on the premise that high and low frequency content must be treated differently during the scaling process. The model-scale distributed exhaust spectra are divided into low and high frequency regions that are then adjusted to full scale separately based on different physics-based scaling laws. The regions are then recombined to create an estimate of the full-scale acoustic spectra. These spectra can then be converted to perceived noise levels (PNL). The paper presents the details of this methodology and provides an example of the estimated noise suppression by a distributed exhaust nozzle compared to a round conic nozzle.

Kinzie, Kevin W.↗

An Intercomparison of Microphysical Retrieval Algorithms for Upper Tropospheric Ice Clouds

The large horizontal extent, location in the cold upper troposphere, and ice composition make cirrus clouds important modulators of the earth's radiation budget and climate. Cirrus cloud microphysical properties are difficult to measure and model because they are inhomogeneous in nature and their ice crystal size distribution and habit are not well characterized. Accurate retrievals of cloud properties are crucial for improving the representation of cloud scale processes in large-scale models and for accurately predicting the earth's future climate. A number of passive and active remote sensing retrieval algorithms exist for estimating the microphysical properties of upper tropospheric clouds. We believe significant progress has been made in the evolution of these retrieval algorithms in the last decade, however, there is room for improvement. Members of the Atmospheric Radiation measurement program (ARM) Cloud properties Working Group are involved in an intercomparison of optical depth(tau), ice water path, and characteristic particle size in clouds retrieved using ground-based instruments. The goals of this intercomparison are to evaluate the accuracy of state-of-the-art algorithms, quantify the uncertainties, and make recommendations for improvement.

Comstock, Jennifer M.↗