Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Tolerance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Summary Report on the Refined User Requirements for U.S. Fusion Prototypic Neutron Source

The Fusion Prototypic Neutron Source (FPNS) is proposed as an urgent near-term facility necessary for understanding D-T fusion neutron degradation processes in materials and for the development of high-performance radiation tolerant materials for fusion power reactors. This facility is central to our goal of predicting the behavior of materials in the harsh D-T neutron environment and calibrating and verifying the materials performance models necessary to support design of next-generation fusion reactors. Key FPNS performance metrics were previously defined for the cost-efficient facility necessary to adequately and expediently resolve key materials science knowledge gaps required to move to next-step fusion devices. This brief report is intended to expand upon this previous metrics discussion as an aid to selecting the most desirable FPNS concept and enabling a facility that meets the program needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Versatile Heat Transfer Module

Development of micro-reactors that can be easily transported to remote areas for civilian or military applications is an immediate focus of U.S. nuclear industry and therefore is being pursued by multiple reactor vendors (e.g. HolosGen LLC, Westinghouse, Ultra Safe Nuclear Corporation, URENCO, etc.) and actively supported by DOE-NE, DOE-ARPA-E and by the Department Of Defense (DoD). Very-high-temperature gas-cooled (VHTR) and heat pipe cooled reactor technologies are regarded as promising concepts for microreactors applications since they enable compact power conversion systems and display beneficial inherent safety features. Development of microreactors with enhanced performance must be supported by innovations in nuclear technologies. Several technologies being developed by the microreactor industry are being revisited with material technologies developed at the Argonne National Laboratory (ANL). Innovative high-temperature compatible solutions are developed to enable advanced thermal-spectrum microreactor designs featuring improved neutronics performance at high-temperature operating conditions to enable high thermal efficiency and economic competitiveness. This report focuses on the Versatile Heat Transfer Module (VHTM) technology that is developed at ANL for heat-transfer in thermal-spectrum microreactors. This technology is built on a liquid alkali metal heat pipe concept while leveraging advanced nuclear material technologies for high-temperature applications at reduced neutronic penalty with potential improvement in inherent safety behavior. The VHTM can be applied to design high-temperature thermal-spectrum microreactor systems with reduced size, weight, uranium enrichment, or increased lifetime. The INFINIT technology deriving from the VHTM enables design of a highly compact long-life microreactor concept for fission surface power (FSP). Demonstration of multiphysics modeling capability was also completed to showcase the added inherent safety benefits obtained with this concept. The VHTM technology remain at an early development stage with low Technology Readiness Level and Manufacturing Readiness Level. The current demonstration of these technologies has focused on manufacturing capability, on performance of the hydrogen diffusion barrier under thermal cycling, while radiation tolerance demonstration is planned. The next step of the demonstration plan will be the assembly of miniature VHTM for high-temperature testing, which can be used as a prototype for future pilot scale demonstration. Such research is critical to pursue development of these technologies that have the clear potential to significantly improve the performance of currently investigated micro-reactors systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large-Scale Additive Manufacturing of Silicon Carbide with Process Monitoring

This report summarizes new capabilities in additive manufacturing (AM) of large-scale silicon carbide (SiC) components under the Advanced Materials and Manufacturing Technologies (AMMT) program. SiC is a promising material that is being considered for many advanced reactor designs due to its high temperature strength, radiation tolerance, minimal neutron absorption, and oxidation resistance [1-8]. One of the primary limitations to using SiC as an in-core structural material is the inability to fabricate large SiC components with complex geometries. While under the former Transformational Challenge Reactor (TCR) program, ceramic AM systems at the Oak Ridge National Laboratory (ORNL) were limited in the quantity and overall size achievable for producing ceramic AM components. To address this, ORNL has improved its infrastructure for binder jet and chemical vapor infiltration (CVI) processes with cutting-edge equipment coming online in a newly renovated laboratory space capable of producing larger components and higher throughput without compromise on part size. This report details the laboratory renovation progress, focusing specifically on the DesktopMetal (formerly ExOne) X25Pro binder jet, a large scale CVI furnace, and the added functionality of a software tool called Peregrine for quality assurance and control purposes.

36 MATERIALS SCIENCE↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Acoustic Sensor Application to Structural Health Monitoring of Reactor Components

The objectives of SHM of advanced fission reactors include the following: (1) Maintain safe, reliable, and efficient operation of structures, systems, and components in accordance with design intent; (3) Reduce cost; (4) Improve the comprehensive life management of structures, systems, and components; and (5) Extend the operational life of a power system through retirement for cause. Advanced reactor designs currently being considered are expected to operate at higher temperatures than light water-cooled reactors and to support missions beyond baseload electricity generation. Methods to monitor and detect for these mechanisms will require structural health monitoring (SHM) techniques, with ultrasonic methods an ideal candidate given their widespread use for NDE. This document summarized the state of technology for ultrasonic technologies, as part of an assessment of technology gaps and needed research. The great majority of sensor development to date addresses elevated temperatures and radiation tolerance, and more work is needed in both areas. Little data exists regarding corrosion effects of advanced coolants on sensor materials and couplants. Of high importance is the need for ARDs and regulatory bodies to engage and define what level of SHM is needed for autonomous or semi-autonomous control of reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Milestone report for MRT 8479: High Yield Xray Imager Preliminary Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi-MJ yield shots. Also, a new radiation tolerance CMOS imaging array is being developed to eliminate the significant background noise which limits the data quality of PDIXI. The HYXI Preliminary Design Review was completed at the end of Q4 FY23. The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the new CMOS imaging array. Initial time integrated NIF data will be collected in Q2 FY25, first time resolved imaging with Daedalus starting in Q2 FY26 and the final performance qualification of the complete HYXI system is scheduled for Q2 FY27.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development Plan for Acoustic Emission and Vibration Sensors

This document discusses the need for high temperature, radiation tolerant sensors for monitoring vibration and acoustic emissions in advanced reactors and irradiation experiments. Testing of several commercial sensors using infrastructure available at Idaho National Laboratory was performed to benchmark currently available sensors as well as the test facilities. Finally, a strategy for developing sensors for more extreme environments is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxide Dispersion Strengthened Ferritic Steel Wire Feedstock Development for Large Format Additive Manufacturing - CRADA 620 (Abstract)

This CRADA project funded through DOE’s INFUSE program seeks to demonstrate the viability of fabricating large, complex parts from oxide dispersion strengthened (ODS) steel with advanced manufacturing. Exhibiting excellent radiation tolerance and high mechanical performance at elevated temperatures, ODS steel is a promising structural material candidate for near-plasma components in fusion energy systems. Its use, however, has been limited by a lack of manufacturability. This project will seek to produce ODS steel wire through a solid-state shear assisted extrusion process and then demonstrate that the wire can undergo controlled local melting while being welded with the final part sufficiently retaining the beneficial properties of ODS steel. This would allow the use of wire-arc additive manufacturing (WAAM) to manufacture large-scale ODS parts, even though ODS is currently only available as a powder. WAAM is a promising technique for producing components like the replaceable ARC vacuum vessel in CFS’ fusion reactor design. Meanwhile, this project will also expand PNNL’s capability in producing custom wire feedstock with friction extrusion, enabling downstream large-scale manufacturing with WAAM and solid-state based additive manufacturing.

36 MATERIALS SCIENCE↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Summary Report on Ion Irradiation Study of Ceramic Coating on Suppressing FCCI

Advanced cladding is critical for advanced nuclear reactors with an enhanced performance in radiation tolerance and neutron transparency. Using advanced cladding will ensure the adequate thermal conductivity and mechanical stability of the cladding base material, corrosion resistance, high-temperature coolant compatibility of the cladding surface, and chemical stability in the cladding inner wall against fuel cladding chemical interaction (FCCI). An innovative cladding with a three-layer structure (i.e., a modified surface, a clad base material, and a modified inner wall) promises to meet all these requirements. Initial research and development (R&D) regarding this innovative cladding seek to demonstrate the effectiveness of a thin ceramic coating in suppressing FCCI under ion irradiation to high dose. This United States (U.S.) Department of Energy (DOE)–Office of Nuclear Energy (NE) project report summarizes the results of recent ion irradiation studies of diffusion-couple samples with details of an ion irradiation experiment, the characterization of the interface microstructure of cerium (Ce)/titanium nitride (TiN)/oxide-dispersion strengthened (ODS), Ce/TiN/iron (Fe), Ce/ODS, and Ce/Fe samples irradiated with 80 million electron-volts (MeV) of xenon (Xe) ions to 100 displacements per atom (dpa) at 500?C using the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory (ANL). The results of the ODS-substrate sample are encouraging and demonstrate the effectiveness of a thin ceramic coating on FCCI mitigation under irradiation. The results from an Fe-substrate sample revealed a complex microstructure, and the root cause is discussed.

36 MATERIALS SCIENCE↗

Status Report on Ion Irradiation Study of Ceramic Coating in Suppressing Fuel/Cladding Chemical Interaction

Advanced cladding is critical for the development of advanced nuclear reactors with enhanced performance in radiation tolerance and neutron transparency. It will ensure adequate thermal conductivity and mechanical stability of cladding base material, corrosion resistance and high temperature coolant compatibility of cladding surface. Finally, it provides chemical stability in the cladding inner wall against fuel/cladding chemical interaction (FCCI). An innovative cladding with a three-layer structure (i.e., a treated surface, a base material, and a treated inner-wall) promises to meet all the listed requirements. The initial work on innovative researching and developing these cladding materials seeks to demonstrate the effectiveness of a thin ceramic coating in suppressing FCCI through ion-irradiation. It consists of a study of Ce/TiN/Fe diffusion couples. This report provides an update on the status of ceramic-coating preparation and the testing of diffusion couple samples, the design of an ion-irradiation experiment, and characterization of the microstructure of a legacy-coupon sample coated with 1 µm of TiN and irradiated with 5 MeV Fe ions to 200 dpa at 500°C.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Design and construction of the CMS Outer Tracker for the Phase-2 Upgrade

he High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of $3000-4000$~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about $5-7.5\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrade, to be able to operate in the challenging environment of the HL-LHC. The current CMS silicon strip tracker has to be replaced with a new detector. The Phase-2 Outer Tracker (OT) will have higher radiation tolerance, higher granularity, and the capability to handle higher data rates compared to the current system. Another key feature of the OT will be to provide tracking information to the Level-1 (L1) trigger, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made out of modules with two closely spaced sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments called stubs. The stubs will be used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), which contain different sensor configurations and multiple ASICs. In this contribution, the design of the CMS Phase-2 OT, the technological choices, and the quality assurance (QA) procedures used to ensure the functionality of the modules will be reported. The contribution will cover the first results with pre-production devices and the different aspects taken into account during the QA: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication between the different ASICs on the module. The module noise performance is also checked and the full module functionality is verified at different temperatures.

Zoi, Irene↗

Evaluation of printability methodologies and feasibility to down select LBPF steel and other materials for nuclear applications

In this work, new research is underway to produce alloys beyond well-known alloys with modified compositions that are better suited to be produced with additive manufacturing. These alloys can only possess improved radiation tolerance but also improved high temperature strength, creep resistance while also using elements that reduce the amount of activation after irradiation. This work package supports the vision and goals of the Advanced Materials and Manufacturing Technology (AMMT) program relevant to accelerate the development and deployment of advanced manufacturing processes. This work focuses on evaluating the methodology for designing alloys best suited for AM processes based on “printability”, literature research to evaluate and down select steel alloy systems. In this work, microstructural characterization and testing activities have been performed on certain steel alloys to support the efforts from collaborating laboratories during the evaluation and printing of the test articles. The final recommendation will be performed by all four participating laboratories.

316L↗

Design and Construction of the CMS Outer Tracker for the Phase-2 Upgrade

The High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000-4000~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about 5-7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have high radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger, for the first time at hadron colliders, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely spaced silicon sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments (stubs), used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), containing different sensor configurations and multiple ASICs. This contribution will present the design of the Phase-2 OT, the first results with pre-production devices, and the quality assurance procedures used to ensure the functionality of the modules: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication among the module's ASICs.

43 PARTICLE ACCELERATORS↗

Oxide Dispersion Strengthened Ferritic Steel Wire Feedstock Development for Larger Format Additive Manufacturing (CRADA Final Report)

This CRADA project funded through DOE’s INFUSE program sought to demonstrate the viability of fabricating large, complex parts from oxide dispersion strengthened (ODS) steel with advanced manufacturing. Exhibiting excellent radiation tolerance and high mechanical performance at elevated temperatures, ODS steel is a promising structural material candidate for near-plasma components in fusion energy systems. Its use, however, has been limited by a lack of manufacturability. This project sought to produce ODS steel wire through a solid-state shear assisted extrusion process and then demonstrate that the wire can undergo controlled local melting while being welded with the final part sufficiently retaining the beneficial properties of ODS steel. This would allow the use of wire-arc additive manufacturing (WAAM) to manufacture large-scale ODS parts, even though ODS is currently only available as a powder. WAAM is a promising technique for producing components like the replaceable ARC vacuum vessel in CFS’ fusion reactor design. Meanwhile, this project will also expand PNNL’s capability in producing custom wire feedstock with friction extrusion, enabling downstream large-scale manufacturing with WAAM and solid-state based additive manufacturing. The project achieved its goals of developing tooling and fixturing to produce ODS wire at smaller diameters than previous projects. Several small lengths of wire of 1.5 mm and 2.5 mm diameter in the range of 2.5-30 mm long were produced at tool temperatures that are known to cause ODS particle coarsening (~1200 °C). Fixtures and tooling for longer (>1 m) wires were developed but further process development is needed reduce tool temperature during extrusions and to increase wire length needed for WAAM testing and development.

36 MATERIALS SCIENCE↗