Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Photoelectron spectrometer with means for stabilizing sample surface potential

An improved X-ray photoelectron spectrometer is disclosed, which includes circuit means to determine the surface potential of a sample, e.g., an insulator. The circuit means comprise an electron gun, whose potential is modulated at a preselected frequency above and below a selected potential with respect to the spectrometer common potential, e.g., ground. The beam of electrons is directed to the sample surface. The sample's surface potential is offset by an offset power supply with respect to the spectrometer common potential until the ac current which flows through the sample reaches a peak amplitude. A lock-in amplifier is included to measure the ac current in phase with the modulating frequency.

Grunthaner, F. J.↗

A small gas inlet system for orbital mass-spectrometer calibrations

A gas inlet system is described for generating precise gas pressures that are to be used as calibration references for the mass spectrometers aboard the dual air density Explorer satellites. This gas inlet system was developed as an inflight calibration technique in which a known amount of onboard gas is released in the satellite cavity and is detected by the mass spectrometer. Although several flight mass spectrometer experiments have been proposed, none make use of the inflight calibration technique described in this report. Laboratory measurements and calibration of the metering leak technique for the gas inlet systems are discussed. The systems tested have metering leak rates between 2 and 4 microliters/sec at 298 K for argon-40, and they produce molecular flow up to 100 torr, which is the highest test pressure in this experiment. Test data show that metering leak rates are reproducible within 1 percent of established means for helium-3, helium-4, and argon-40.

Smith, A.↗

Fourier and Hadamard transform spectrometers - A limited comparison. II

A mathematical approach was used to compare interferometric spectrometers and Hadamard transform spectrometers. The principle results are reported, noting that the simple Hadamard spectrometer encodes more efficiently than a Michelson interferometer which, in turn, encodes less efficiently than is usually acknowledged. Hirschfeld's (1977) major objections to these findings are discussed, although it is noted that none of his objections is supported by evidence.

Harwit, M.↗

The University of Colorado OSO-8 spectrometer experiment. I - Introduction and optical design considerations

The optical design of the high-resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200-2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 arcsec normal to the direction of the slit and is selectable from about 3 arcsec to 15 arcmin along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer.

Bruner, E. C., Jr.↗

A mass spectrometer-beam experiment for investigations of planetary atmospheres

An experimental concept for investigation of planetary atmospheres using a mass spectrometer is discussed. High atmospheric pressures are reduced to mass spectrometer operating pressures by means of differential pumping. Sampling is accomplished through the formation of a molecular beam. A flag in front of the mass spectrometer can be used to separate ambient gases from system background. Laboratory tests have confirmed the feasibility of the experiment, particularly in CO2 dominated atmospheres.

Mauersberger, K.↗

Global model of longitude/UT variations in thermospheric composition and temperature based on mass spectrometer data

Measurements of N2, O, He, and Ar densities from neutral gas mass spectrometers on four satellites and inferred O2 and H densities from an ion mass spectrometer have been combined to produce a model of longitude/UT variations in thermospheric neutral composition and temperature. The longitude/UT model is an extension of the mass spectrometer-incoherent scatter thermospheric model (Hedin et al., 1977) and uses spherical harmonic terms dependent on geographic latitude, longitude, and UT. The combined longitude and UT variations reflect the influence of the geomagnetic field but indicate that the variations may not simply be represented in magnetic coordinates.

Hedin, A. E.↗

A liquid-helium-cooled grating spectrometer for far infrared astronomical observations

A liquid-helium-cooled grating spectrometer has been developed for low-resolution far-infrared spectrometric measurements of astronomical sources conducted by the 30-cm NASA Lear Jet telescope. Simple MOSFET coupled transimpedance preamplifiers were adopted for the spectrometer design. The infrared spectrometer has resolving powers from 10 to 150 over the wavelength range from 45 to 115 microns.

Houck, J. R.↗

Comparison of atmospheric density data from mass spectrometers and atmospheric drag on the Aeros satellites

The comparison of perigee density data near 230 km for satellite Aeros-A has been extended to the complete mission time. The average ratio between orbital drag derived density and mass spectrometer measurements is very near to 1 with a large scatter reflected by a standard deviation of the order of 20%. A method of comparison was developed and tested which uses the observed rate of change of orbital period in comparison with the orbital decay computed from the actual mass spectrometer data measured at discrete positions along the orbit. This method proves that deviations from the average ratio of 1 between perigee densities from drag and mass spectrometers are due to the smoothing and poor resolution of the orbital drag technique.

Roemer, M.↗

Cosmic ray studies with a gas Cherenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cherenkov counter (threshold 16.5 GeV/nucleon) and an ionization spectrometer are presented. The gas Cherenkov counter provides an absolute energy distribution for the response of the calorimeter for 5 or = Z 26 nuclei of cosmic rays. The contribution of scintillation to the gas Cherenkov pulse height was obtained by independently selecting particles below the gas Cherenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi squared between Monte Carlo simulted data and flight data. Best fit power laws, dN/dE = AE-gamma, were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E (-2.7) are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer. The data from the ionization calorimeter and the gas Cherenkov are thus completely self-consistent.

Balasubrahmanyan, V. K.↗

Cooled echelle grating spectrometer

A cooled echelle grating spectrometer for detecting wavelengths between one micron and fifteen microns is disclosed. More specifically, the spectrometer has a cross-dispersing grating for ordering infrared energy and an echelle grating for further ordering of the infrared energy. Ordered radiation from the echelle grating is sensed by a detecting means. Also disclosed is use of a Schmidt camera for focusing the further ordered radiation from the echelle grating onto a detector array having individual detectors dispersed on a plane which substantially corresponds to a curved focal plane of the Schmidt camera. A spectrometer constructed according to the teachings of the present invention will continuously cover the spectrum between one micron and fifteen microns and have a resolution of 0.1/cm.

Beer, R.↗

Pioneer Venus Sounder Probe Neutral Gas Mass Spectrometer

A neutral gas mass spectrometer was flown to Venus as part of the Pioneer Venus Multiprobe to measure the composition of its lower atmosphere. The instrument, mounted in the Sounder Probe, was activated after the probe entered the top of the atmosphere, and it obtained data during the descent from 62 km to the surface. Atmospheric gases were sampled through a pair of microleaks, the effluent from which was pumped by a combination of ion and getter pumping. A pneumatically operated valve, controlled by the ambient atmospheric pressure, maintained the ion source pressure at a nearly constant value during descent while the atmospheric pressure varied by three orders of magnitude. A single focusing magnetic sector field mass spectrometer with mass resolution sufficient to reasonably separate argon from C3H4 at 40 amu provided the mass analysis and relative abundance measurements. A microprocessor controlled the operation of the mass spectrometer through a highly efficient peak-tip stepping routine and data compression algorithm that effected a scan of the mass spectrum from 1 to 208 amu in 64 sec while requiring an information rate of only 40 bits/sec to return the data to earth. A subscale height altitude resolution was thus obtained. Weight, size, and power requirements were minimized to be consistent with interplanetary flight contraints.

Hoffman, J. H.↗

Cosmic ray studies with a gas Cerenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cerenkov counter (threshold 16.5 GeV/nuc) and an ionization spectrometer are presented. The gas Cerenkov counter provides an absolute energy calibration for the response of the calorimeter for the Z range of 5-26 nuclei of cosmic rays. The contribution of scintillation to the gas Cerenkov pulse height has been obtained by independently selecting particles below the gas Cerenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi-squared between a Monte Carlo simulated data and flight data. Best fit power laws were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E exp-2.7, are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer.

Balasubrahmanyan, V. K.↗

Infrared Fourier spectrometer for airborne and ground-based astronomy

A unique high resolving power near-infrared, astronomical Fourier spectrometer has been constructed for use at both ground-based and airborne telescopes. Its capabilities include a limiting resolution of 0.01/cm and spectral coverage over the InSb detector sensitivity region (0.8-5.6 micron). The instrument is optimized for operation in environments inaccessible to other high-resolution Fourier spectrometers, namely, the Cassegrain focuses of conventional telescopes and the NASA Kuiper Airborne Observatory's 91-cm telescope. Details of the spectrometer are discussed, and various astronomical and laboratory spectra are presented.

Davis, D. S.↗

A cloud condensation nucleus spectrometer designed for airborne measurements

The spectrometer is a simple extension of the continuous flow diffusion chamber (CFDC) operated in the vertical mode. The principal new design features of the instrument are its rapid time response and ability to rapidly measure the CCN activity spectrum. The activity spectrum of CCN in an air sample is measured by simultaneously operating the spectrometer at four supersaturations. The CCN spectrometer consists of four essentially indepenent CFDC's in a parallel array. Each CFDC is 61 cm long, 10 cm wide, and consists of two vertical parallel plates 1 cm apart, maintained at different temperatures. Each CFDC has a single particle optical counter located at the center of its base.

Radke, L. F.↗

A Fourier transform spectrometer for visible and near ultra-violet measurements of atmospheric absorption

The development of a prototype, ground-based, Sun-pointed Michelson interferometric spectrometer is described. Its intended use is to measure the atmospheric amount of various gases which absorb in the near-infrared, visible, and near-ultraviolet portions of the electromagnetic spectrum. Preliminary spectra which contain the alpha, 0.8 micrometer, and rho sigma tau water vapor absorption bands in the near-infrared are presented to indicate the present capability of the system. Ultimately, the spectrometer can be used to explore the feasible applications of Fourier transform spectroscopy in the ultraviolet where grating spectrometers were used exclusively.

Parsons, C. L.↗

A Shuttle Upper Atmosphere Mass Spectrometer /SUMS/ experiment

A magnetic mass spectrometer is currently being adapted to the Space Shuttle Orbiter to provide repeated high altitude atmosphere data to support in situ rarefied flow aerodynamics research, i.e., in the high velocity, low density flight regime. The experiment, called Shuttle Upper Atmosphere Mass Spectrometer (SUMS), is the first attempt to design mass spectrometer equipment for flight vehicle aerodynamic data extraction. The SUMS experiment will provide total freestream atmospheric quantitites, principally total mass density, above altitudes at which conventional pressure measurements are valid. Experiment concepts, the expected flight profile, tradeoffs in the design of the total system and flight data reduction plans are discussed. Development plans are based upon a SUMS first flight after the Orbiter initial development flights.

Blanchard, R. C.↗

Extreme ultraviolet imaging spectrometer for thermospheric emissions

One of the instruments that has been developed to fly on the Space Shuttle is the Imaging Spectrometric Observatory, an array of five imaging spectrometers to cover the 300-12,000-A wavelength range. In this paper the spectrometer designed to operate in the extreme ultraviolet is described. The instrument is intended for studies of the thermosphere and magnetosphere and support of various plasma experiments to be performed from the Shuttle. The design is modular so that various components such as gratings and detectors can be changed and optimized for a range of specific studies following the first survey mission. The detector is an intensified 2-D CCD which permits simultaneous spectral and spatial imaging. The spectral multiplexing gives the spectrometer a considerable speed advantage. The instrument has a small field of view and is thus capable of obtaining much needed scale height information on the atmospheric EUV emissions. Operating from the Shuttle, global and temporal coverage will be obtained, and the EUV data will be enhanced by the simultaneously acquired UV, visible, and near-IR observations.

Torr, M. R.↗

Search for time variations in 511 keV flux by ISEE-3 gamma-ray spectrometer

Upper limits to the variation of galactic 511 keV flux as observed by the ISEE-3 gamma-ray spectrometer for 500 days of nearly continuous observation are reported. It is pointed out that if sources similar to the galactic center source were distributed uniformly throughout the Galaxy, a source within 2-3 kpc could have been detected by the ISEE-3 spectrometer. The lack of detection is evidence that the galactic center source is unique within the Galaxy. The galactic center observations made with the HEAO-3 gamma-ray spectrometer are seen as supporting the contention that a time-varying source is 511 keV emission lies near the galactic center.

Norris, J. P.↗