Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

On the advantages of exploiting memory in Markov state models for biomolecular dynamics

Biomolecular dynamics play an important role in numerous biological processes. Markov State Models (MSMs) provide a powerful approach to study these dynamic processes by predicting long time scale dynamics based on many short molecular dynamics (MD) simulations. In an MSM, protein dynamics are modeled as a kinetic process consisting of a series of Markovian transitions between different conformational states at discrete time intervals (called “lag time”). To achieve this, a master equation must be constructed with a sufficiently long lag time to allow interstate transitions to become truly Markovian. This imposes a major challenge for MSM studies of proteins since the lag time is bound by the length of relatively short MD simulations available to estimate the frequency of transitions. Here, we show how one can employ the generalized master equation formalism to obtain an exact description of protein conformational dynamics both at short and long time scales without the time resolution restrictions imposed by the MSM lag time. Using a simple kinetic model, alanine dipeptide, and WW domain, we demonstrate that it is possible to construct these quasi-Markov State Models (qMSMs) using MD simulations that are 5–10 times shorter than those required by MSMs. These qMSMs only contain a handful of metastable states and, thus, can greatly facilitate the interpretation of mechanisms associated with protein dynamics. A qMSM opens the door to the study of conformational changes of complex biomolecules where a Markovian model with a few states is often difficult to construct due to the limited length of available MD simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic strain evolution in an optically excited Pt thin film

The structural evolution of a Pt thin film following photo-thermal excitation by 1 ps optical laser pulses was studied with a time resolution of 100 ps over a total time period of 1 ms. Laser pulse fluences below 50 mJ/cm 2 were insufficient to relax the residual stress state of the as-prepared film even after 10 000 pulses. In this fluence regime, a rapid initial lattice expansion and a decrease in the lattice coherence length due to ultrafast photo-thermal heating were observed. The lattice expansion reached a maximum, and the coherence length reached a minimum, 100–200 ps after excitation before monotonically decaying back to their initial values in about 1 µs. Laser pulse fluences greater than 50 mJ/cm 2 produced irreversible stress relaxation within the first 10 optical pulses. In this regime, the lattice expansion was qualitatively similar to that in the low fluence regime, except that the initial structural state was not recovered. The evolution in the coherence length, however, was more complex. Following an initial decrease similar to that observed at low fluence, the coherence length then increased to a broad maximum greater than the initial value, before recovery.

36 MATERIALS SCIENCE↗

Direct measurement of Stokes–Einstein diffusion of Cowpea mosaic virus with 19 µs-resolved XPCS

Brownian motion of Cowpea mosaic virus (CPMV) in water was measured using small-angle X-ray photon correlation spectroscopy (SA-XPCS) at 19.2 µs time resolution. It was found that the decorrelation time τ(Q) = 1/DQ 2 up to Q = 0.091 nm -1 . The hydrodynamic radius R H determined from XPCS using Stokes–Einstein diffusion D = kT/(6πηR H ) is 43% larger than the geometric radius R 0 determined from SAXS in the 0.007 M K 3 PO 4 buffer solution, whereas it is 80% larger for CPMV in 0.5 M NaCl and 104% larger in 0.5 M (NH 4 ) 2 SO 4 , a possible effect of aggregation as well as slight variation of the structures of the capsid resulting from the salt–protein interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The HTAP_v3 emission mosaic: merging regional and global monthly emissions (2000–2018) to support air quality modelling and policies

This study, performed under the umbrella of the Task Force on Hemispheric Transport of Air Pollution (TF-HTAP), responds to the global and regional atmospheric modelling community's need of a mosaic emission inventory of air pollutants that conforms to specific requirements: global coverage, long time series, spatially distributed emissions with high time resolution, and a high sectoral resolution. The mosaic approach of integrating official regional emission inventories based on locally reported data, with a global inventory based on a globally consistent methodology, allows modellers to perform simulations of high scientific quality while also ensuring that the results remain relevant to policymakers. HTAP_v3, an ad hoc global mosaic of anthropogenic inventories, has been developed by integrating official inventories over specific areas (North America, Europe, Asia including Japan and South Korea) with the independent Emissions Database for Global Atmospheric Research (EDGAR) inventory for the remaining world regions. The results are spatially and temporally distributed emissions of SO 2 , NO $x$ , CO, non-methane volatile organic compounds (NMVOCs), NH 3 , PM 10 , PM 2.5 , black carbon (BC), and organic carbon (OC), with a spatial resolution of 0.1º × 0.1º and time intervals of months and years, covering the period 2000–2018. The emissions are further disaggregated into 16 anthropogenic emitting sectors. This paper describes the methodology applied to develop such an emission mosaic, reports on source allocation, differences among existing inventories, and best practices for the mosaic compilation. One of the key strengths of the HTAP_v3 emission mosaic is its temporal coverage, enabling the analysis of emission trends over the past 2 decades. The development of a global emission mosaic over such long time series represents a unique product for global air quality modelling and for better-informed policymaking, reflecting the community effort expended by the TF-HTAP to disentangle the complexity of transboundary transport of air pollution.

54 ENVIRONMENTAL SCIENCES↗

Shock Initiation Microscopy with High Time and Space Resolution

In this paper, we describe studies of shock initiation and shock-to-detonation transitions in energetic materials using a tabletop shock compression microscope with nanosecond time resolution and micrometer spatial resolution. Planar input shocks with durations of 4–20 ns are produced using 0–4.5 km/s laser-launched flyer plates. Emphasis is on measurements of temperature, velocities, pressure, and microstructure using photon Doppler velocimetry (PDV), optical pyrometry and high-speed videography. Techniques are discussed for fabricating disposable shock target arrays of tiny plastic-bonded explosives (PBX), liquid and powder explosives, and single-crystal explosives for high-throughput studies. Optical temperature measurements of shocked triaminotrinitrobenzene (TATB) are discussed. Since TATB is yellow, we developed methods to correct for the blue absorption to obtain more accurate temperatures. Hot spots in shocked polymer-encased HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) crystals are observed in real-time, showing a hot spot produced in a collapsing void that ignites a deflagration. Despite the small dimensions of our explosive charges (typically 1 mm diameter and 250 μm length), we produced reproducible detonation states in solid and liquid explosives using short-duration shocks near the von Neumann spike (VNS) pressure. We show the VNS pressure is associated with a transition to high-efficiency gas production from the explosives. In studies of NM, prior to detonation, we see reaction originating at hot spots which coalesce to form a superdetonation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impurity-enhanced core valence luminescence via Zn-doping in cesium magnesium chlorides

Scintillators with faster timing capabilities are currently in high demand for use in radiation detection systems in the fields of nuclear and medical physics. The limited number of suitable materials that meet the performance criteria of next generation detection systems presents an opportunity for discovery of new fast scintillator materials. In this work, the effects of doping several ultrafast core-valence luminescent (CVL) scintillators with divalent Zn is explored. Three compounds are investigated – CsMgCl 3 , Cs 2 MgCl 4 , and Cs 3 MgCl 5 – and single crystals of each doped with 5 mol% Zn are grown via the Bridgman method. Additionally, mixing across the full range of concentrations (from 0 % to 100 % Zn) is explored in the Cs 2 Mg 1-x Zn x Cl 4 and Cs 3 Mg 1-x Zn x Cl 5 systems. For low concentrations of Zn, light yields of all three compounds are enhanced (by up to ~60 %) compared to the pure crystals, achieving what we believe to be the brightest known CVL, CsMgCl 3 :Zn 5 % (3400 ± 170 ph/MeV light yield). More importantly, Zn doping does not affect the ultrafast timing properties, with each composition maintaining a single-component decay time around 1–3 ns. A sub-100 ps coincidence time resolution (CTR) is also achieved with CsMgCl 3 :Zn 5 %. The results of this work reveal a new avenue towards obtaining brighter CVL materials, which could open up possibilities for more advanced ultrafast scintillators to be discovered moving forward.

36 MATERIALS SCIENCE↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Results from ADRIANO2 Test Beams

A novel high-granularity, dual-readout calorimetric technique (ADRIANO2) is under development as part of the research program of T1604 Collaboration. (Talk Presented at the 19th International Conference on Calorimetry in Particle Physics (CALOR 2022), University of Sussex, Sussex, UK, 16–20 May 2022). The building block of such a calorimeter consists of a pair of optically isolated, small size tiles made of scintillating plastic and lead glass. The prompt Čerenkov light from the glass can be exploited to perform high resolution timing measurements, while the high granularity provides good resolution of the spatial components of the shower. Dual-readout compensation and particle flow techniques can be applied simultaneously to the scintillation and to the Čerenkov section, providing excellent energy resolution as well as PID particle identification. These characteristics make ADRIANO2 a 6-D detector, suited for High Energy as well as High Intensity experiments. A report on the status of the ADRIANO2 project, preliminary measurements of light yield, and current and future R&D plans by T1604 Collaboration are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the U.S. Western Electric Interconnection to Understand the Consequences of Hydrometeorological Extremes and Options for Risk Mitigation

Electricity grid operators around the world face a dual challenge; withstanding increasingly severe weather and the longer term impacts of climate change, while simultaneously decarbonizing. Extreme weather events such as heat waves and droughts are rising in both severity and frequency, which is threatening the reliability of electricity grids through increased demand, generation capacity losses, and equipment failures. Consequently, incorporating hydrometeorological stressors into computational power systems analysis is becoming an even more critical tool in long term planning and short term operations. However, there is a general lack of open-source customizable grid simulation software capable of exhaustively stress testing the grid under hydrometeorological uncertainty, and/or examining potential risk mitigation pathways. A related, persistent challenge for power system modelers is striking an appropriate balance between model fidelity (e.g. spatial scale and time resolution) and computational tractability (wall clock run-time). In this study, we are proposing a solution to this problem with open-source software that allows users to seamlessly customize the scale and track the accuracy of grid operations models. Our approach allows users to search over numerous model parameters (network topology, mathematical formulation, economic hurdle rates, and transmission line scaling) to identify model instantiations that accommodate experimental design. Further, we use this approach to demonstrate the importance of including extreme weather events in model validation and model selection. Focusing on the occurrence of heatwaves and droughts in the U.S. Western Interconnection, we examine role of extreme events in balancing tradeoffs between model fidelity and run-time at the model design stage.

Economics↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

Shock-induced kinetics and cellular structures of liquid nitromethane detonation

Using a combination of high-speed diagnostics, optical pyrometry, velocimetry and video photography, we examine the spatiotemporal reaction kinetics of a prototypical high-energy explosive, liquid nitromethane (NM), as we drive this high explosive into detonation. The detonations were initiated by powerful shock waves whose durations (4 ns) were shorter than the characteristic time associated with the reaction (7 ns). Simple optical spectroscopy alone cannot characterize the kinetics with high time resolution because the reactants and products are flowing at a high velocity of ~6 km/s (6 µm/ns). Additionally, every detection volume behind the shock front contains material initiated over a range of times. High spatial resolution can be obtained by probing interfaces where the shock enters or breaks out of the NM. In addition, we obtain cellular patterns imprinted on the luminous shock front by the two-stage explosion in NM. These spatiotemporal patterns arise naturally as a result of the asymmetry produced by the moving shock front. In this way the shock front serves as a thin moving intrinsic optical gauge that reports and characterizes the two-stage NM explosion behind the front.

42 ENGINEERING↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The motional Stark effect diagnostic for ITER

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Instruments & Instrumentation↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

47 OTHER INSTRUMENTATION↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗