Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time of Flight (ToF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delineation of the impact on temporal behaviors of off-axis photoemission in an ultrafast electron microscope

Efforts to push the spatiotemporal imaging-resolution limits of femtosecond laser-driven ultrafast electron microscopes (UEMs) to the combined angstrom–fs range will benefit from stable sources capable of generating high bunch charges. Recent demonstrations of unconventional off-axis photoemitting geometries are promising, but connections to the observed onset of structural dynamics are yet to be established. Here we use the in-situ photoexcitation of coherent phonons to quantify the relative time-of-flight (r-TOF) of photoelectron packets generated from the Ni Wehnelt aperture and from a Ta cathode set-back from the aperture plane. We further support the UEM experiments with particle-tracing simulations of the precise electron-gun architecture and photoemitting geometries. In this way, we measure discernible shifts in electron-packet TOF of tens of picoseconds for the two photoemitting surfaces. Furthermore, these shifts arise from the impact that the Wehnelt-aperture off-axis orientation has on the electron-momentum distribution, which modifies both the collection efficiency and the temporal-packet distribution relative to on-axis emission. Future needs are identified; we expect this and other developments in UEM electron-gun configuration to expand the range of material phenomena that can be directly imaged on scales commensurate with fundamental structural dynamics.

47 OTHER INSTRUMENTATION↗

The LED calibration systems for the mDOM and D-Egg sensor modules of the IceCube Upgrade: Design, production, testing and use in module calibration

The IceCube Neutrino Observatory, instrumenting about 1 km 3 of deep, glacial ice at the geographic South Pole, is due to be enhanced with the IceCube Upgrade. The IceCube Upgrade, to be deployed during the 2025/26 Antarctic summer season, will consist of seven new strings of photosensors, densely embedded near the bottom center of the existing array. Aside from a world-leading sensitivity to neutrino oscillations, a primary goal is the improvement of the calibration of the optical properties of the instrumented ice. This calibration will be applied to the entire archive of IceCube data, improving the angular and energy resolution of the detected neutrino events. For this purpose, the Upgrade strings include a host of new calibration devices. Aside from dedicated calibration modules, several thousand LED flashers have been incorporated into the photosensor modules. We describe the design, production, and testing of these LED flashers before their integration into the sensor modules as well as the use of the LED flashers during lab testing of assembled sensor modules.

Analogue electronic circuits↗

Mass measurements of neutron-rich nuclei near $N = 70$

The astrophysical origin for the chemical elements between the first and second r-process peaks is a matter of intense debate, with a number of nucleosynthesis processes at explosive stellar environments possibly contributing to their production. Reliable data on the trends of neutron separation energies of neutron-rich isotopes are required to model neutron-capture processes that would produce these elements. Masses of 104 Y, 106 Zr, 112 Mo, and 115 Tc have been measured with the time-of-flight-magnetic-rigidity (ToF–Bρ) technique at the National Superconducting Cyclotron Laboratory at Michigan State University. The experiment is the first application of the ToF–Bρ technique at the S800 spectrograph that reached the mass region relevant to heavy-element nucleosynthesis. Finally, the two-neutron separation energy deduced from the measured masses exhibits a smooth trend consistent with the theoretical predictions within the range of experimental uncertainty, indicating that there is no sudden shape transition in these isotopes as hinted at by previous data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of an inexpensive matrix-assisted laser desorption—time of flight mass spectrometry method for the identification of endophytes and rhizobacteria cultured from the microbiome associated with maize

Many endophytes and rhizobacteria associated with plants support the growth and health of their hosts. The vast majority of these potentially beneficial bacteria have yet to be characterized, in part because of the cost of identifying bacterial isolates. Matrix-assisted laser desorption-time of flight (MALDI-TOF) has enabled culturomic studies of host-associated microbiomes but analysis of mass spectra generated from plant-associated bacteria requires optimization. In this study, we aligned mass spectra generated from endophytes and rhizobacteria isolated from heritage and sweet varieties of Zea mays. Multiple iterations of alignment attempts identified a set of parameters that sorted 114 isolates into 60 coherent MALDI-TOF taxonomic units (MTUs). These MTUs corresponded to strains with practically identical (>99%) 16S rRNA gene sequences. Mass spectra were used to train a machine learning algorithm that classified 100% of the isolates into 60 MTUs. These MTUs provided >70% coverage of aerobic, heterotrophic bacteria readily cultured with nutrient rich media from the maize microbiome and allowed prediction of the total diversity recoverable with that particular cultivation method. Acidovorax sp., Pseudomonas sp. and Cellulosimicrobium sp. dominated the library generated from the rhizoplane. Relative to the sweet variety, the heritage variety contained a high number of MTUs. The ability to detect these differences in libraries, suggests a rapid and inexpensive method of describing the diversity of bacteria cultured from the endosphere and rhizosphere of maize.

dereplication↗

Multielement analysis of interplanetary dust particles using TOF-SIMS

Sections of three stratospheric particles (U2015G1, W7029*A27, and L2005P9) were analyzed with TOF-SIMS (Time Of Flight-Secondary Ion Mass Spectrometry) continuing our efforts to investigate the element distribution in interplanetary dust particles (IDP's) with high lateral resolution (approximately 0.2 micron), to examine possible atmospheric contamination effects, and to further explore the abilities of this technique for element analysis of small samples. The samples, previously investigated with SXRF (synchrotron X-ray fluorescence analysis), are highly enriched in Br (Br/Fe: 59 x CI, 9.2 x CI, and 116 x CI, respectively). U2015G1 is the IDP with the by far highest Zn/Fe-ratio (81 x CI) ever reported in chondritic particles.

Stephan, T.↗

Aluminum hydroxide, bayerite, boehmite, and gibbsite ToF-SIMS spectra in the positive ion mode. II

We report time-of-flight secondary ion mass spectrometry (ToF-SIMS) was performed for boehmite (AOH-60) and its potential products of oxidation including pseudo-boehmite (AOH-180), α- and γ-Al 2 O 3 , and α- and γ-Al(OH) 3 . Since boehmite often forms on the cladding materials to prevent corrosion, surface analysis techniques are performed to determine the amount of oxidation present. This ToF-SIMS spectral library is of significance because it includes boehmite and its potential oxidation products (i.e., aluminum oxide and hydroxide), which can be used to compare to spectra obtained for real-world samples containing boehmite. Furthermore, ToF-SIMS is often used as a complementary technique to x-ray photoelectron spectroscopy (XPS) due to its surface sensitivity and ability to compare spectra via multivariate analysis, therefore establishing the molecular signatures of boehmite and relevant compounds are essential for peak identification. The SIMS spectra shown are acquired from commercially available powders, which were deposited onto a Si wafer substrate via liquid slurry drop casting. This library of SIMS mass spectra will serve as a comparison of boehmite [γ-AlO(OH)], pseudo-boehmite [AlOOH∙nH 2 O], α- and γ-Al 2 O 3 aluminum oxide, and α- and γ-Al 2 O 3 aluminum hydroxide in the positive ion mode, which compliments those reported in the negative ion mode (Part 1).

36 MATERIALS SCIENCE↗

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Mapping the N = 40 island of inversion: Precision mass measurements of neutron-rich Fe isotopes

Nuclear properties across the chart of nuclides are key to improving and validating our understanding of the strong interaction in nuclear physics. Here we present high-precision mass measurements of neutron-rich Fe isotopes performed at the TITAN facility. The multiple-reflection time-of-flight mass spectrometer (MR-ToF-MS), achieving a resolving power greater than 600000 for the first time, enabled the measurement of 63–70 Fe, including first-time high-precision direct measurements (δm/m ≈ 10 -7 ) of 68–70 Fe, as well as the discovery of a long-lived isomeric state in 69 Fe. These measurements are accompanied by both mean-field and ab initio calculations using the most recent realizations which enable theoretical assignment of the spin-parities of the 69 Fe ground and isomeric states. Together with mean-field calculations of quadrupole deformation parameters for the Fe isotope chain, these results benchmark a maximum of deformation in the N = 40 island of inversion in Fe and shed light on trends in level densities indicated in the newly refined mass surface.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast Dynamics of Molecules on Surfaces Studied with Time-Resolved XUV Photoelectron Spectroscopy (Final Report)

In this project we set out to make technical advances in time-resolved photoemission from surfaces and study molecule-surface charge transfer processes. Combining a novel light source developed at Stony Brook with a new type of time-of-flight photoemission electron microscope (TOF k-mic) developed in Mainz, Germany, we achieved the former goal. Our light source, based on cavity-enhanced high harmonic generation at 61 MHz repetition rate, enables ultrafast time-resolved photoemission experiments to be conducted with orders of magnitude higher photocurrents than otherwise possible. Critically, this provides the high dynamic range necessary to study perturbatively excited samples, such that one can study the intrinsic dynamics of electrons and holes as they would occur in a device. Combining our light source with the TOF k-mic, we’ve achieved an overall improvement in data rate of time- and angle-resolved photoemission (tr-ARPES) of approximately four orders of magnitude over the previous state-of-the-art using kHz-repetition rate sources and conventional hemispherical electron analyzers. This new instrument is now being used in experiments on 2D materials and organic semiconductors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhancing the Cherenkov over scintillation ratio using dichroic filters in BGO and TlCl for TOF-PET

Abstract The Cherenkov emission in inorganic crystal scintillators has been shown to dramatically improve time resolution for time-of-flight positron emission tomography (TOF-PET) for in slow scintillators with a high refractive index such as bismuth germanium oxide (BGO). This is due to the faster nature of the Cherenkov emission (tens of picoseconds) with respect to scintillation (nanosecond). However, the presence of slower scintillation light and the inability of existing detectors to distinguish between Cherenkov and scintillation make it difficult for BGO to achieve a good CTR for all the detected coincidence events. In this paper, we exploit the difference between the Cherenkov and scintillation emission spectra and use dichroic filters to enhance the Cherenkov over scintillation ratio. Dichroic filters transmit or reflect photons based on their wavelength, with a photon attenuation lower than 10%. We investigate several shortpass and longpass dichroic filters in a single-photon configuration with BGO and find the optimal filter that maximizes the Cherenkov over scintillation ratio. We demonstrate that we can enhance the ratio of Cherenkov to scintillation photons by a factor of 2.17 ± 0.38 by employing a shortpass dichroic filter with a cut-off wavelength of 450 nm for BGO, and by a factor of 2.87 ± 0.40 using a longpass dichroic filter with a cut-on wavelength of 550 nm for iodine/beryllium-doped thallium chloride.

Science & Technology - Other Topics↗

Elemental, Isotopic, and Organic Analysis on Mars with Laser TOF-MS

The in-depth landed exploration of Mars will require increasingly sophisticated robotic analytical tools for both in situ composition science [1] and reconnaissance for sample return [2]. Beyond dust, rock surfaces, and topsoil, samples must be accessed within rocks and ice, well below surface soil, and possibly in elevated deposit layers. A range of spatial scales will be studied, and for the most information-rich microscopic analyses, samples must be acquired, prepared, and positioned with high precision. In some cases samples must also be brought into a vacuum chamber. After expending such resources, it will be important to apply techniques that provide a wide range of information about the samples. Microscopy, mineralogy, and molecular/organic, elemental, and isotopic analyses are all needed, at a minimum, to begin to address the in situ goals at Mars. These techniques must work as an efficient suite to provide layers of data, each layer helping to determine if further analysis on a given sample is desired. In the spirit of broad-band and efficient data collection, we are developing miniature laser time-of-flight mass spectrometers (TOF-MS) for elemental, isotopic, and molecular/organic microanalysis of unprepared solid samples. Laser TOF-MS uses a pulsed laser to volatilize and ionize material from a small region on the sample. The laser energy and focus can be adjusted for atomic and molecular content, sampling area, and depth. Ions travel through the instrument and are detected at a sequence of times proportional to the square root of their mass-to- charge ratios. Thus, each laser pulse produces a complete mass spectrum (in less than 50 microseconds). These instruments can now be significantly miniaturized (potentially to the size of a soda can) without a loss in performance. This effort is reviewed here with an emphasis on applications to Mars exploration.

Brinckerhoff, W. B.↗

Evaluating the feasibility of LA-ICP-TOF-MS for the analysis of environmental particle collections

Laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) was employed to rapidly analyze environmental particle samples collected using aerosol contaminate extractors (ACE). The ACE particle collectors were placed at various distances (0.5, 1.3, and 4.5 km) from a source that released Ru-bearing particles. Samples for measurement were then generated (as sub-samples) from the ACE collection plates via particle “lift off” with gunshot residue (GSR) tabs. The LA-ICP-TOF-MS method was employed such that 10+ samples could be analyzed in a single unattended analytical session. A 3 × 1 mm area of individual GSR tab samples were analyzed in less than 30 minutes. This provided spatially resolved elemental and isotopic measurements of the particulate content and confirmed the presence of Ru-bearing particles within the complex background environmental particle loading. As anticipated, measurements showed collectors closest to the source had the highest concentration of the released Ru-bearing particles, while all collectors, regardless of distance, contained similar levels of background particles (e.g., Fe and Sr). Sequential scanning electron microscopy – automated particle analysis (SEM-APA) and LA-ICP-TOF-MS analysis was employed for method validation and a demonstration of the multi-modal approach. The same 2-dimensional region was analyzed by both methods and the particles identified via SEM-APA were also detected using LA-ICP-TOF-MS, with 100% accuracy. Overall, LA-ICP-TOF-MS demonstrated its utility for rapid elemental and isotopic particle analysis from environmental air samples.

Manard, Benjamin T. [Oak Ridge National Laboratory↗

Locating Methyl-Etherified and Methyl-Esterified Uronic Acids in the Plant Cell Wall Pectic Polysaccharide Rhamnogalacturonan II

Rhamnogalacturonan II (RG-II) is a structurally complex pectic polysaccharide that exists as a borate ester cross-linked dimer in the cell walls of all vascular plants. The glycosyl sequence of RG-II is largely conserved, but there is evidence that galacturonic acid (GalA) methyl etherification and glucuronic acid (GlcA) methyl esterification vary in the A sidechain across plant species. Methyl esterification of the galacturonan backbone has also been reported but not confirmed. Here we describe a new procedure, utilizing aq. sodium borodeuteride (NaBD4)-reduced RG-II, to identify the methyl esterification status of backbone GalAs. Our data suggest that up to two different GalAs are esterified in the RG-II backbone. We also adapted a procedure based on methanolysis and NaBD4 reduction to identify 3-, 4-, and 3,4-O-methyl GalA in RG-II. These data, together with matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry (MALDI-TOF) MS analysis of sidechain A generated from selected RG-IIs and their NaBD4-reduced counterparts, suggest that methyl etherification of the ß-linked GalA and methyl esterification of the GlcA are widespread. Nevertheless, the extent of these modifications varies between plant species. Our analysis of the sidechain B glycoforms in RG-II from different dicots and nonpoalean monocots suggests that this sidechain has a minimum structure of an O-acetylated hexasaccharide (Ara-[MeFuc]-Gal-AceA-Rha-Api-). To complement these studies, we provide further evidence showing that dimer formation and stability in vitro is cation and borate dependent. Taken together, our data further refine the primary sequence and sequence variation of RG-II and provide additional insight into dimer stability and factors controlling dimer self-assembly.

BASIC BIOLOGICAL SCIENCES↗

Study of cluster ions produced from ToF-SIMS analysis of a U-6%Nb target

Cluster ions have been previously observed during time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of metals and metal oxides. Furthermore, we have used ToF-SIMS to investigate cluster ions formed from the hydrocarbon-containing overlayer, the mixed U and Nb surface oxide, and underlying metal of a U-6 %Nb (U6Nb) target. In the overlayer, we observe U x O y + oxides and U-species likely containing hydrocarbons. In the surface oxide, we observe UO 2 +, U 2 O 2 +, U 3 O 5 +, and U 4 O 6 + as the most intense ions for each family of oxide ions containing x U atoms. Nb oxides for NbO 1-2 - were only observed in negative polarity. In contrast to the oxide, analysis of the underlying U6Nb alloy resulted in repeating units of U n +, U n (Nb)+, and U n (Nb 2 ) + ions for n = 3–11 as the highest intensity ions for each family of ions containing n U atoms. Nb n + clusters were not observed. U n +, U n (Nb)+, and U n (Nb 2 )+ clusters containing C- and O-species were observed and were likely produced from soluble C or O species or precipitates known to be present in U6Nb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure-dependent particulate populations in ODS steels revealed by single-particle ICP-TOF-MS

In this work, we evaluated the ability of single-particle inductively coupled plasma time-of-flight mass spectrometry (SP-ICP-TOF-MS) to characterize particulates generated from 300 series stainless steels and oxide dispersion–strengthened (ODS) steels. Particulates were produced using two different rotary tools (cutting disk and grinding bit) to assess the influence of particle generation on effluent particulates. Across all materials and preparation techniques, SP-ICP-TOF-MS detected a substantial population of particles containing the expected constituent elements, with average compositions closely matching the nominal alloy values. A secondary population of Y-bearing particles was evident in ODS steels; their formation is strongly favored in particulates generated using the grinding bit. Specifically, in PM2000, Y-bearing particles were predominantly colocated with Al, whereas in 14YWT, Y-bearing particles were less frequently Fe-free but showed stronger colocation with Ti. These trends are consistent with the known microstructural differences between Y–Al–O oxide particles in PM2000 and finer Y–Ti–O nanoclusters in 14YWT. Together, these results demonstrate that SP-ICP-TOF-MS can resolve distinct particulate populations in complex, multicomponent steels at the femtogram mass scale, enabling particle-resolved insight into microstructure-driven phase separation and preparation-dependent particle generation.

Brubaker, Zach E. [Oak Ridge National Laboratory (↗

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗