Search NASASearch

SEARCH · Search NASA

Results for “VERY HIGH TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

815 records · Page 10

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Semi-Transparent Perovskite Solar Cells in a Stacked Tandem Module: Cooperative Research and Development Final Report, CRADA Number CRD-19-00810

This project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, anti-reflection layer composition and deposition process, and cell to module integration processes. Modification 5: The proposed project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically-stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, passivation layers including in module scribes, anti-reflection layer composition and deposition process, and cell to module integration processes. Advanced metrology and characterization will be performed on perovskite films, cells and module. Furthermore, we will examine module or materials recycling for circular economy considerations. Modifcation 6: Gigahertz frequency microwave pump-probe spectroscopies are highly sensitive to thin film semiconductor photoconductivity of individual and stacks of layers that comprise perovskite solar cells. As such, these techniques will be used to qualify reproducibility and quality correlations during the manufacturing process. Modification 7: Mechanical adhesion of top contacts within perovskite modules significantly impacts the durability of the module when exposed to accelerated degradation testing. The adhesion between the perovskite/transport layer interface and the transport layer/top contact interface are both very sensitive small changes in processing. ALD processing conditions of the transport layer will be tuned to optimize the mechanical adhesion within the perovskite module stack.

14 SOLAR ENERGY

Nuclear Safety [Vol. 37, No. 3, July-September 1996]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS 181 Attitudes and Practices Regarding Disposal of Liquid Nuclear Waste at Clinton Laboratories in the Very Early Years: A Historical Analysis, S. H. Stow; 202 Off-Site Nuclear Emergency Management in Germany Under the Auspices of the Federal Structure, A. Bayer, S. Bittner, and H. Korn; DESIGN FEATURES: 211 Twenty-Fourth DOE/NRC Nuclear Air-Cleaning and Treatment Conference, R. R. Bellamy, J. J. Hayes, R. D. Porco, and M. W. First; OPERATING EXPERIENCES: 222 Explosion in the Tomsk-7 Reprocessing Plant on April 6, 1993, M. L. Hyder, W. G. Lussie, and F. E. Witmer; 234 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 237 Assessment of Spent Fuel Cooling, J. G. Ibarra, W. R. Jones, G. F. Lanik, H. L. Ornstein, and S. V. Pullani; RECENT DEVELOPMENTS: 256 Reports, Standards, and Safety Guides, D. S. Queener; 260 Proposed Rule Changes as of June 30, 1996; ANNOUNCEMENTS: 210 Tennessee Industries Week; 221 21st International Symposium on The Scientific Basis for Nuclear Waste Management; 259 IAEA Programme of Scientific Meetings for 1997; 270 PSAM 4 (International Conference on Probabilistic Safety Assessment and Management); 265 The Authors; 268 Errata.

05 NUCLEAR FUELS

Nanohybrid of Cu2O-Ti3C2Tx as a Silver-Free MXene Sorbent for Iodine Gas Capture from Nuclear Waste

The capture of volatile radioiodine from nuclear fuel reprocessing off-gas streams remains a critical challenge due to the high volatility, long half-life of 129I, and biological uptake of iodide from the environment. Although silver-based sorbents provide strong iodine chemisorption, their high cost and regulatory classification as mixed radioactive-hazardous waste motivate the development of alternative materials. Here, we report a silver-free Cu2O-Ti3C2Tx MXene hybrid for iodine gas capture at 150 °C. Structural and compositional analyses confirm the formation of Cu2O nanoparticles on Ti3C2Tx nanosheets and their subsequent conversion to thermodynamically stable CuI upon static iodine gas exposure, achieving an iodine mass loading of up to 1115 mg/g. These results demonstrate the potential of Cu2O-Ti3C2Tx MXene as a copper-based alternative to silver sorbents for elevated-temperature iodine gas capture.

iodine gas capture

Are There Opportunities To Re-Think How We Manufacture Synthetic Graphite?

This manuscript contributes a Viewpoint article to ACS Sustainable Resource Management and discusses the graphite supply chain, growing mismatch between graphite demand and global manufacturing capacity, current graphite manufacturing technologies, and different feedstocks.

alternative carbon feedstocks

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]

Equation of state for Hf, Ta, W, Re, Os, Ir, Pt, and Au to multi-terapascal pressures from density-functional theory

We present the zero-temperature equation of state (pressure dependence of compression) and phase stability predictions for the 5d-transition metals obtained from all-electron density-functional theory (DFT) calculations. The results compare favorably with experiments but extend beyond current experimental capabilities to 10 TPa. Our study reveals phase changes that are explained from the calculated electronic structure. The cubic face-centered and body-centered structures (fcc and bcc), together with two-, three-, and four-layered hexagonal structures, play major roles under compression. The results’ dependence on the electron exchange and correlation in the DFT approach is investigated, and it is shown that the impact of the choice, while significant at lower pressures, diminishes in the terapascal regime. We further illustrate that the normal parabolic trends in atomic volume and bulk modulus with atomic number, due to the occupation of bonding and anti-bonding 5d states, break down at TPa pressures, suggesting drastically different chemical bonding at these extreme conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Improving creep resistance of Al-0.27Zr-0.08Sn (wt%) via cold swaging while maintaining high electrical conductivity

This study investigates the effect of mechanical cold work (0, 50, and 90% cross-sectional area reduction via swaging) on the creep properties of cast aluminum alloys with high electrical conductivity including high-purity Al (HP-Al), Al-0.15Zr (Al-Zr), and Al-0.27Zr-0.08Sn (Al-Zr-Sn, wt%). The Al-Zr alloy is strengthened by Zr in solid solution while the Al-Zr-Sn alloy is additionally strengthened by Al3Zr nanoprecipitates (8 nm diameter). After 90% cold swaging, the alloys exhibit grains elongated along the swaging direction with their widths ranging between 8 and 152 μm perpendicular to the swaging direction. Creep testing at 200 °C shows that the minimum creep rate of all 90% swaged alloys shows high sensitivity to stress, which can be modeled via a threshold stress σth. Increasing swaging magnitude from 0 to 50 to 90% in Al-Zr-Sn improves the creep resistance without reducing electrical conductivity. The formation of subgrains, increased dislocation density, and columnar grain structure in swaged alloys all enhance creep resistance. HP-Al swaged to 90% exhibits much lower creep resistance (σth = 18 MPa) due to subgrain coarsening and the absence of precipitates compared to Al-Zr (σth = 40 MPa) and Al-Zr-Sn (σth = 40 MPa), which maintain stable subgrain structures and benefit from solid solution strengthening and Al3Zr nanoprecipitates, respectively. Although Al3Zr precipitates are known to stabilize the deformed microstructure by pinning grain-boundaries, this work demonstrates that Zr in solid solution alone can effectively stabilize the deformed microstructure resulting in enhanced creep resistance. This effect of Zr solute on stabilizing grain boundaries for creep performance was not previously well-defined in the literature. Despite similar creep performances of Al-Zr and Al-Zr-Sn, the latter shows 70% higher room-temperature microhardness and slightly improved electrical conductivity (56%IACS (International Annealed Copper Standard) vs. 57%IACS, respectively). This work provides new insights into creep mechanisms of cold-worked Al–Zr alloys that will guide the design of heat-resistant Al conductors for high-demand applications.

Coello ramirez, Ismael [Northwestern University,]

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Jumpstart Opportunities to Unleash Leadership in Energy Storage (JOULES)

Current-generation Li-ion batteries with cobalt- and nickel-containing cathodes and graphite anodes are approaching performance and cost limits. In this program, 24M Technologies, Inc. (24M) is teaming with the Massachusetts Institute of Technology (MIT) and University of Michigan (UM) to develop low cost and fast charging sodium metal batteries with good low-temperature performance and high energy density, building upon previous work performed under ARPA-E programs. Key achievements include optimization of solid electrolyte and anode current collector, optimized cathode active materials, development of high-performance electrolyte formulations, and integration of these components into full cells. The cell design incorporates (1) an ultra-thick cathode (>9 mAh/cm 2 ) comprising advanced cobalt-free, sodium cathode active material, (2) advanced fast-charging electrolyte (up to 12 mS/cm) developed using machine learning and automated high-throughput screening technology by UM, and (3) ceramic modified separator that enable smooth Na transport and deposition, developed at MIT, enabling a high-energy density anode-free configuration and maximizing the energy density of sodium batteries. The team has successfully combined these approaches to sodium chemistry and paved the way to meeting the fast-charging, high-energy density, and low-cost requirements of next-generation drone, electric vertical take-off and -landing, and electric vehicle batteries. Performance for anode-free sodium cells developed under this program is more powerful than the commercial Li-ion batteries. The final deliverable cell design has achieved over 300 Wh/kg and volumetric energy density above 800 Wh/L (Table 1). Additionally, the team has achieved over (1) a lifetime of 340 cycles, (2) 80% capacity retention at -20 °C (compared 25 °C), and (3) the ability to fast charge to 80% SOC in 20 minutes.

25 ENERGY STORAGE

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Development of Novel Combustion Codes for Supercritical CO2 Combustion: Cooperative Research and Development Final Report, CRADA Number CRD-20-17182

The Allam-Fetvedt Cycle, a novel supercritical CO2 (sCO2) power cycle developed by 8 Rivers Capital, LLC, generates low-cost power from fossil fuels while capturing combustion-CO2. This cycle employs high-temperature oxy-combustion using sCO2 as the working fluid, leading to a challenging environment for materials. The most critical component for reliable deployment of this technology is the combustor-turbine interface. In the proposed partnership between NREL and 8 Rivers, we will develop a simulation-based tool to provide key design inputs for defining the materials and geometries required in this critical area.

09 BIOMASS FUELS

Advanced Model Development for Large Eddy Simulation of Oxy-Combustion and Supercritical Carbon Dioxide Power Cycles

A joint experimental and numerical study is performed to observe the characteristics of a supercritical carbon dioxide turbulent mixing layer in the presence of strong nonlinearities in the thermodynamic and transport properties. A bespoke experimental setup is designed and employed for this purpose and provides insight into macroscopic mixing behavior. The mixing is experimentally observed using two techniques: shadowgraphy and spontaneous Raman scattering. Qualitative and quantitative intensity fields obtained via these techniques yield instantaneous and mean density data. Spanwise temperature data is also collected using analogue resistance temperature detectors. These measurements are used to quantify the level of mixed material within the field. The experimental data are supplemented by a companion high-fidelity numerical study. The numerical results are obtained through fully resolved, three-dimensional direct numerical simulation. The numerical dataset permits observation of the near-field mixing characteristics, which are difficult to measure experimentally due to the rapid dynamics and sharp thermophysical gradients in this area. Qualitative field visualizations are presented, followed by quantitative mixed material results and observations regarding thermodynamic property trends at select locations within the field. One-dimensional spectra of the turbulent kinetic energy and solenoidal dissipation are provided to observe the spectral characteristics of the flow. Reynolds stress anisotropy is analyzed graphically through anisotropy invariance maps (Lumley triangles). The mixing quantification, spectral data and anisotropy analysis of a flow at these thermodynamic conditions represent the main outcomes of the work.

20 FOSSIL-FUELED POWER PLANTS

High Pressure Synthesis of Ultrasmall Nanodiamonds with Nitrogen Vacancy Centers

C–H terminated nanometer scale diamonds ( d = 1 to 15 nm) are synthesized from 1-fluoroadamantane at high pressure (6–8 GPa) and high temperature (500–1500 °C) in a multianvil press. High resolution transmission electron microscopy, X-ray diffraction, Raman, diffuse reflectance Fourier transform infrared, and X-ray absorption spectroscopies demonstrate the excellent crystallinity and atomically flat C–H terminated surfaces of nanodiamonds with (111) and (110) facets. The importance of hydrogen to the synthesis of nanodiamond and its faceting is discussed. Following vacancy generation, annealing and oxidation of the nanodiamonds, optically detected magnetic resonance and electron spin resonance coherence times ( T 2 = 0.9 and 2.1 μs) of nitrogen vacancy (NV) centers are measured. Finally, the obtained T 2 values are equivalent to the shallow NV centers (depth <10 nm) in bulk diamond crystals and larger nanocrystals prepared by mechanical milling.

36 MATERIALS SCIENCE

Additively manufactured refractory high-entropy alloys with superior radiation resistance

Refractory high-entropy alloys (RHEAs) are promising candidates for next-generation nuclear and high-temperature applications. Among many approaches to manufacture RHEAs, additive manufacturing (AM) represents the most recent and advanced metal manufacturing method which allows near-net-shape manufacturing to reduce material waste and post-processing time. However, performance of AM RHEAs under complex irradiation conditions remains largely unexplored. Here, in this study, we demonstrate for the first time the response of directed energy deposition (DED) AM quaternary RHEAs (HfTaVW, CrTaVW) subjected to sequential dual-beam ion irradiation, consisting of helium pre-implantation followed by high-dose heavy ion bombardment. Compositions of DED AM RHEAs were selected using Monte Carlo (MC) simulations based on a cluster expansion (CE) Hamiltonian parameterized by density functional theory (DFT). Post-irradiation microstructural characterization revealed that the AM RHEA maintained remarkable stability, with suppressed helium bubble growth and reduced defect accumulation compared to conventional alloys. Even at high doses (∼100 dpa), the alloy exhibited no void swelling, a low density of dislocation loops, and no evidence of severe degradation. These results highlight the intrinsic ability of AM-derived microstructures and multicomponent chemistry to synergistically mitigate irradiation effects. Our findings establish AM RHEAs as a class of materials with superior resistance to radiation damage under conditions relevant to advanced fusion and fission environments and demonstrate the importance of sequential ion beam studies in evaluating their long-term performance.

36 MATERIALS SCIENCE

Design and Modeling of the Charge Readout of a SiMOS Quantum Dot with a Single Electron Transistor and CryoCMOS

Single electron spin qubits trapped in SiMOS quantum dots are a promising technology for scaling to thousand- or million-qubit systems due to their compatibility with mature CMOS manufacturing processes. A readout system that combines a single electron transistor with a custom cryogenic CMOS amplification and digitization chain offers key advantages by avoiding the use of bulky RF components or room-temperature interconnects. We present design techniques and simulation results for an optimized qubit-SET cryoCMOS interface, culminating in the design of the QNDR1 ASIC, the first cryogenic readout ASIC designed under the Quandarum project, which targets the development of a many-channel spin qubit based detector for use in high energy physics.

Quinn, Adam [Fermilab] (ORCID:0009000605056371)

Activating magnetite ores for aqueous ironmaking at high current densities

Low-temperature electrochemical cells reducing iron oxides to metal in alkaline electrolytes can support fully electrified steelmaking processes. Previous studies on these cells have primarily focused on high-surface-area hematite, Fe 2 O 3 , reactants whereas attempts to reduce suspensions of magnetite, Fe 3 O 4 —one of the two feedstocks for existing ironmaking reactors—have generally been limited to low rates of reaction (<30 mA cm −2 ). Here, in this study, we control the crystalline domain size of Fe 2 O 3 and Fe 3 O 4 particles in 10 M NaOH electrolytes to study how the nanoscale morphology of oxides controls the rate of electrochemical ironmaking. Rotating-ring disk electrode measurements of Fe 2+ , in situ Raman spectroscopy of the electrode surface, and ex situ electron microscopy were consistent with a hypothesized passivation process at Fe 3 O 4 surfaces that may prevent the continuous formation of soluble intermediates. Sufficiently small (<100 nm diameter) oxide particles yielded Fe partial current densities >160 mA cm −2 , a fivefold increase relative to previously reported rates for Fe 3 O 4 suspensions and comparable to active Fe 2 O 3 . Electron microscopy revealed that electrodeposited films were composed of micron-scale crystalline Fe domains with a porous film of Fe 3 O 4 nanoparticles and supports a model where Fe is grown primarily from soluble Fe 2+ intermediates. Based on these insights, inactive blast-furnace-grade iron-oxides were transformed into high surface area nanoparticles (1.6 to 229.2 m 2 g −1 ) via reprecipitation, leading to a ninefold enhancement in faradaic efficiency and an Fe partial current density of 120 mA cm −2 . When integrated with chlor-iron cells producing reagents for reprecipitation, this approach could lead to a cost-competitive process for electrochemical ironmaking from industrially relevant feedstocks.

TEM