At least 181 records · Page 10

Vehicle load-equalization system

System uses cables and associated pulleys to form closed-loop suspension system for terrain compensation. Loop causes reactions at each of three wheels in response to loading at remaining wheel. Simplicity of design should be of interest to designers and manufacturers of construction equipment and off-road vehicles.

Creasy, W. K.↗

Dynamic analysis and experiment methods for a generic space station model

Modal vibration tests in conjunction with finite element analysis were used to characterize a generic dynamic model. The model consists of five substructures to simulate the multi-body, low frequency nature of large space structures. Static tests were used to refine the substructure analytical models prior to full assemblage analysis. The effects of a cable suspension system are analyzed using prestressed vibration analysis. Coupling between a cable suspension mode and model bending mode is shown to be influenced by the distance from the model center of gravity to the cable-to-model attachment location. A damping characterization method using noncontacting exciters was used to measure amplitude dependent damping. Frequency and damping measurements in ambient air and at near-vacuum conditions are presented.

Belvin, W. K.↗

Effect of Mechanical Deformation on the Dielectric Electric Field in Dynamic Umbilical Cables

Wave energy converter (WEC) systems have unique umbilical cable design requirements compared to conventional marine designs. Due to their dynamic nature, WEC umbilical cables are required to handle increased loads and larger motions over longer deployment scenarios. However, the life expectancy of dynamic umbilical cables is predominantly analyzed for mechanical fatigue, with little consideration given to the effect of mechanical stress on the response of the dielectric as it has been previously assumed that the non-polymeric components will fail prior to the polymeric components. In this work, we explore the effects of mechanical bending on the concentration of the electric field in the insulation of a conceptual three-core dynamic umbilical cable to determine the limiting requirements for life expectancy. A conceptual industrial schematic of a medium voltage dynamic umbilical cable was used as the basis for the WEC system under study. Simulations on the dynamic umbilical cable were performed using COMSOL Multiphysics®. Mechanical loads up to the calculated limit (2.64 m minimum bend radius or 388 kN transverse load) were applied to the dynamic umbilical in a step-wise fashion with one end of the umbilical cable fixed. One-way coupling in three-dimensions was conducted by first determining the engineering strains, then using the engineering strains as the initial condition for determination of the Green-Lagrange strains, and lastly calculating the electric field in the deformed dielectric. Based upon the input load, deformation of the dielectric at the minimum bend radius produced an increase in the electric field of more than 12% when compared to the undeformed umbilical cable, which may lead to dielectric breakdown of the insulation prior to mechanical failure of the umbilical cable.

Spencer, Mychal P.↗

Investigation of problems associated with solid encapsulation of high voltage electronic assemblies; also Reynolds connector study

Electric breakdown prevention in vacuum and encapsulation of high voltage electronic circuits was studied. The lap shear method was used to measure adhesive strengths. The permeation constants of air at ambient room temperature through four different space-grade encapsulants was measured. Order of magnitude was calculated for the time that air bubble pressures drop to the corona region. High voltage connectors with L-type cable attached were tested in a vacuum system at various pressures. The cable system was shown to suppress catastrophic breakdown when filled with and surrounded by gas in the corona region of pressures, but did not prove to be completely noise free.

Bever, R. S.↗

Cable coupling lightning transient qualification

Simulated lightning strike testing of instrumentation cabling on the redesigned solid rocket motor was performed. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of instrumentation cable transients on cables within the system tunnel. The maximum short-circuit current induced onto a United Space Boosters, Inc., operational flight cable within the systems tunnel was 92 A, and the maximum induced open-circuit voltage was 316 V. These levels were extrapolated to the worst-case (200 kA) condition of NASA specification NSTS 07636 and were also scaled to full-scale redesigned solid rocket motor dimensions. Testing showed that voltage coupling to cables within the systems tunnel can be reduced 40 to 90 dB and that current coupling to cables within the systems tunnel can be reduced 30 to 70 dB with the use of braided metallic sock shields around cables that are external to the systems tunnel. Testing also showed that current and voltage levels induced onto cables within the systems tunnel are partially dependant on the cables' relative locations within the systems tunnel. Results of current injections to the systems tunnel indicate that the dominant coupling mode on cables within the systems tunnel is not from instrumentation cables but from coupling through the systems tunnel cover seam apertures. It is recommended that methods of improving the electrical bonding between individual sections of the systems tunnel covers be evaluated. Further testing to better characterize redesigned solid rocket motor cable coupling effects as an aid in developing methods to reduce coupling levels, particularly with respect to cable placement within the systems tunnel, is also recommended.

Cook, M.↗

Thermal Control of Boundaries for JWST Infrared Tests in Cryogenic Vacuum Configuration

In 2017, the combined Optical Telescope Element and Integrated Science Instrument Module (OTIS) of the James Webb Space Telescope (JWST) underwent functional testing and optical metrology verification under cryogenic vacuum conditions in Chamber A at the Johnson Space Center (JSC). Testing the infrared Science Instruments and OTIS optics below 50 degrees Kelvin required an environment architecture that comprehensively controlled the temperature and energy path of every seam and penetration in the over 1100 m2 of Chamber A helium shroud surfaces as well as the Ground Support Equipment (GSE) inside it. This paper outlines the design and implementation of thermal closeouts, thermal anchoring systems for electrical cables, and thermal control systems around room-temperature optical metrology equipment inside the helium shroud. It also details lessons learned from the repeated implementation and testing of these environmental control systems throughout the JWST Pathfinder test campaign.

Huguet, Jesse A.↗

Thermal Control of Boundaries for JWST Infrared Tests in Cryogenic Vacuum Configuration

In 2017, the combined Optical Telescope Element and Integrated Science Instrument Module (OTIS) of the James Webb Space Telescope (JWST) underwent functional testing and optical metrology verification under cryogenic vacuum conditions in Chamber A at the Johnson Space Center (JSC). Testing the infrared Science Instruments and OTIS optics below 50 K required an environment architecture that comprehensively controlled the temperature and energy path of every seam and penetration in the over 1100 sq m of Chamber A helium shroud surfaces as well as the Ground Support Equipment (GSE) inside it. This paper outlines the design and implementation of thermal closeouts, thermal anchoring systems for electrical cables, and thermal control systems around room-temperature optical metrology equipment inside the helium shroud. It also details lessons learned from the repeated implementation and testing of these environmental control systems throughout the JWST Pathfinder test campaign.

Huguet, Jesse A.↗

Investigation robot on cables - 15250

The Decontamination and Decommissioning (D and D) Operations take place in hostile environments to the human intervention. In this context, robotic systems are a solution to achieve these operations while minimizing human intervention. Among these operations, the monitoring of lengthwise plant has to be performed in places where the radioactive contaminations make hostile environments. These monitoring operations need to measure several physics parameters in several locations in a precise and safe manner. These repetitive tasks can be made by robots that are simple, small sized and easily adaptable. In this scope, a robotic system on cables has been designed to control and monitor the inside of lengthwise nuclear facilities. In lengthwise installations, the using of cables allows to increase the covered zone of the robots which is an essential quality in such places. Unlike cable-driven parallel robots used in workspaces of 2D or 3D controlled by redundant tensioning motors, the current robot moves in a 1D workspace. Thus a tractors cable controlled by one tensioning motor is used to drive the robot on carrier cables. In this paper, we will describe the first results of this work by bringing out the innovation of our system. Then, we will discuss the perspective to upgrade the actual system whose applications could be perfectly imagined outside the nuclear D and D industry. (authors)

42 ENGINEERING↗

Number of lightning discharges causing damage to lightning arrester cables for aerial transmission lines in power systems

Damage by lightning discharges to lightning arrester cables for 110-175 kV aerial transmission lines is analyzed using data from power systems on incidents with aerial transmission lines over a ten year operating period (1997-2006). It is found that failures of lightning arrester cables occur when a tensile force acts on a cable heated to the melting point by a lightning current. The lightning currents required to heat a cable to this extent are greater for larger cable cross sections. The probability that a lightning discharge will develop decreases as the amplitude of the lightning current increases, which greatly reduces the number of lightning discharges which damage TK-70 cables compared to TK-50 cables. In order to increase the reliability of lightning arrester cables for 110 kV aerial transmission lines, TK-70 cables should be used in place of TK-50 cables. The number of lightning discharges per year which damage lightning arrester cables is lowered when the density of aerial transmission lines is reduced within the territory of electrical power systems. An approximate relationship between these two parameters is obtained.

42 ENGINEERING↗

JPS heater and sensor lightning qualification

Simulated lightning strike testing of the Redesigned Solid Rocket Motor (RSRM) field joint protection system heater assembly was performed at Thiokol Corp., Wendover Lightning Facility. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of heater cable transients on cables within the systems tunnel. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by transients from all cables external to the systems tunnel, was 92 amperes. The maximum open-circuit voltage coupled was 316 volts. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by heater power cable transients only, was 2.7 amperes; the maximum open-circuit voltage coupled was 39 volts. All heater power cable induced coupling was due to simulated lightning discharges only, no heater operating power was applied during the test. The results showed that, for a worst-case lightning discharge, the heater power cable is responsible for a 3.9 decibel increase in voltage coupling to operational flight cables within the systems tunnel. Testing also showed that current and voltage levels coupled onto cables within the systems tunnel are partially dependant on the relative locations of the cables within the systems tunnel.

Cook, M.↗

A Cable Condition Monitoring Strategy for Safe and Reliable Plant Operation

Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.

36 MATERIALS SCIENCE↗

Electromagnetic Compatibility Design, Implementation and Test of the SMAP Spacecraft to Meet Stringent L-Band Radiated Emissions Requirements

This paper describes the electromagnetic compatibility (EMC) requirements on the NASA SMAP mission, the implementation of EMC best practices at various levels of development in subsystems packaging and system level cabling harnesses, and the testing and result s of flight hardware at the sub system and spacecraft system levels.

Huang, Chi-Chien Nelson↗

Considerations in the design of a communication network for an autonomously managed power system

The considerations involved in designing a communication network for an autonomously managed power system intended for use in space vehicles are examined. An overview of the design and implementation of a communication network implemented in a breadboard power system is presented. An assumption that the monitoring and control devices are distributed but physically close leads to the selection of a multidrop cable communication system. The assumption of a high-quality communication cable in which few messages are lost resulted in a simple recovery procedure consisting of a time out and retransmit process.

Mckee, J. W.↗

A proposed adjustable RF cable connector

In system that requires negligible loss, it may be necessary to adjust cable length to exact multiple of transmitted wavelength. Adjustable cable connector saves time and cost by eliminating need to add to or cut from cable. Device was especially designed for use with high frequencies. For particular application, connector of suitable dimensions should be used.

Stringer, E. J.↗

Cable-splice detector

Detector has possible uses in aerial cable-car systems, equipment handling in mines, boreholes, and undersea operations, and other applications where moving steel cable must be measured, monitored, or controlled. Detector consists of Hall-effect magnetic sensor located close to cable. Magnetic markings on cable are converted to electrical signals. Signals are filtered, amplified, and can actuate alarm.

Lee, R. D.↗

EMPHASIS/Nevada CABANA user Guide. Version 2.0.

The CABle ANAlysis (CABANA) portion of the EMPHASIS{trademark} suite is designed specifically for the simulation of cable system-generated electromagnetic pulse (SGEMP). The code can be used to evaluate the response of a specific cable design to threat or to compare and minimize the relative response of difference designs. This document provides user-specific information to facilitate the application of the code to cables of interest. It solves the electrical portion of a cable SGEMP simulation. It takes specific results from the deterministic radiation-transport code CEPTRE as sources and computes the resulting electrical response to an arbitrary cable load. The cable geometry itself is also arbitrary and is limited only by the patience of the user in meshing and by the available computing resources for the solution. The CABANA simulation involves solution of the quasi-static Maxwell equations using finite-element method (FEM) techniques.

99 GENERAL AND MISCELLANEOUS↗

Electromagnetic Compatibility Design, Implementation and Test of the SMAP Spacecraft to Meet Stringent L-Band Radiated Emissions Requirements

This paper describes the electromagnetic compatibility (EMC) requirements on the NASA SMAP mission, the implementation of EMC best practices at various levels of development in system level cabling harnesses and subsystems packaging, and the testing and results of flight hardware at the subsystem and spacecraft system levels.

Huang, Chi-Chien Nelson↗