Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Synchrotron-based Characterization Techniques for Radiation Detection Materials and Devices: An Overview

High-performance room-temperature radiation detectors (high energy resolution for spectrometers, high spatial resolution for imaging devices, and low defect-density for high flux applications) are needed for photon energies (>20 keV) that are not well suited for silicon detectors. Applications for such radiation detectors include nonproliferation, synchrotron, medical, astrophysics, and homeland security. Material- and device- characterization to understand and solve the limiting factors of radiation detection materials and devices is a core element of a radiation detector development R&D program. This presentation will give an overview on the two main synchrotron-based characterization techniques that have been employed by the authors in the last ~20 years: (1) White Beam X-ray Diffraction Topography and (2) Micron-scale detector mapping. A perfect (one domain) crystal (radiation detection material) is a requirement to achieve a highperformance radiation detector. White Beam X-ray Diffraction Topography (WBXDT) allows the rapid screening of the crystallinity of the detector material. With WBXDT we can quickly screen CZT and other crystals to make sure they have only one domain, and to see the presence of extended defects and strain fields.

Camarda, Giuseppe S.↗

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATLAS toward the High Luminosity era: challenges on electronic systems

To maximize the physics reach, the Large Hadron Collider (LHC) plans to increase its instantaneous luminosity to $7.5×10^{34} cm^{-2} s^{-1}$ and deliver $3 - 4 ab^{-1}$ of data at a center-of-mass energy of 14 TeV. To profit from this high-luminosity LHC operation with a pile-up up to 200 inelastic collisions per bunch crossing, performance of the ATLAS detector needs to be maintained and in many systems, improved. The upgraded detector will have an unprecedented output data rate of up to 200 TB/s. Real-time processing of this large data volume in a short time period is extremely challenging. New sets of both front-end and back-end electronics are required for all sub-detectors. The large number of detector channels, huge volumes of input and output data, short time available to process and transmit data, harsh radiation environment, and the need of low power consumption all impose great challenges on the designs of electronic systems.

43 PARTICLE ACCELERATORS↗

Doped semiconductor devices for sub-MeV dark matter detection

Dopant atoms in semiconductors can be ionized with ∼ 10 meV energy depositions, allowing for the design of low-threshold detectors. We propose using doped semiconductor targets to search for sub-MeV dark matter scattering or sub-eV dark matter absorption on electrons. Currently unconstrained cross sections could be tested with a 1 g-day exposure in a doped detector with backgrounds at the level of existing pure semiconductor detectors, but improvements would be needed to probe the freeze-in target. We discuss the corresponding technological requirements and lay out a possible detector design. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Topical Group on Application and Industry Community Engagement Frontier Snowmass 2021 (Summary Report)

HEP community leads and operates cutting-edge experiments for the DOE Office of Science which have challenging sensing, data processing, and computing requirements that far surpass typical industrial applications. To make necessary progress in the energy, material, and fundamental sciences, development of novel technologies is often required to enable these advanced detector and accelerator programs. Our capabilities include efficient co-design, which is a prerequisite to enable the deployment of advanced techniques in a scientific setting where development spans from rapid prototyping to robust and reliable production scale. This applies across the design spectrum from the low level fabrication techniques to the high level software development. It underpins the requirement for a holistic approach of innovation that accelerates the cycle of technology development and deployment. The challenges set by the next generation of experiments requires a collaborative approach between academia, industry and national labs. Just a single stakeholder will be unable to deliver the technologies required for the success of the scientific goals. Tools and techniques developed for High Energy Physics (HEP) research can accelerate scientific discovery more broadly across DOE Office of Science and other federal initiatives and also benefit industry applications.

43 PARTICLE ACCELERATORS↗

The Accelerator Neutrino Neutron InteractionExperiment: Design, Construction and Preparationfor First Physics

This thesis covers work performed for the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) between 2015 and 2020. ANNIE is a beamline neutrino experiment located at the Fermi National Accelerator Laboratory in Chicago. Its primary physics goals are the measurement of neutrino interaction cross-sections on oxygen, and a measurement of the multiplicity of final state neutrons from these interactions, both as functions of final state kinematics. In order to achieve these goals ANNIE will be pioneering the use of Large Area Picosecond Photodetectors and the use of gadolinium doping to enhance neutron visibility in a water Cherenkov detector. Over the time period of this thesis the ANNIE detector was constructed, an initial 'Phase I' background run was completed, the detector was decommissioned and then substantially upgraded in preparation for the main 'Phase II' physics run. At the time of writing ANNIE is being re-commissioned, with Phase II data taking anticipated to begin in 2021. During this time I spent 21/2 years on-site contributing to almost all aspects of hardware work, while performing software development for the simulation and analysis frameworks. As my first software task I developed Monte Carlo simulations of the detector response, based on the WCSim framework. While thismore » framework provided a starting point for the tank simulation significant modifications were required to implement the complete ANNIE detector system. This included a rewrite of the geometry, along with modifications to the photosensor definitions, hit collections, digitization, triggering, input and output interfaces, etc. To take advantage of improved modelling of neutrons in Geant4.10 the physics lists were also reimplemented in the new version format. As part of this work I determined performance metrics based on the output files, calculating kinematic acceptance, detector efficiency and expected event rates. My contributions on reconstruction focused primarily on the MRD, for which I implemented two track reconstruction algorithms, specialised for high and low energy muons. The high energy algorithm achieves >90% efficiency for tracks with at least 8 hits, and is robust against dead paddles and unrelated hits. The low energy algorithm performs a search in combination with tank information to provide sensitivity down to a single MRD hit. Early data handling work for the Phase I background run included writing the code for handling TDC hits and performing studies on neutron detection without the requirement of multi-hit coincidence. As the collaboration moved to a new framework for the Phase II analysis I performed a substantial amount of work to develop the codebase, implementing tools to perform tasks such as file IO, data parsing, waveform processing, event building, timestamp alignment, time clustering, hit residual calculation, event visualisation etc. I helped develop the python API for integrating multi-language tools, and ported the framework into a Singularity container to provide a self-contained environment that…« less

43 PARTICLE ACCELERATORS↗

Detector and Beamline Simulation for Next-Generation High Energy Physics Experiments

The success of high energy physics programs relies heavily on accurate detector simulations and beam interaction modeling. The increasingly complex detector geometries and beam dynamics require sophisticated techniques in order to meet the demands of current and future experiments. Common software tools used today are unable to fully utilize modern computational resources, while data-recording rates are often orders of magnitude larger than what can be produced via simulation. In this paper, we describe the state, current and future needs of high energy physics detector and beamline simulations and related challenges, and we propose a number of possible ways to address them.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector R&D needs for the next generation $e^+e^-$ collider

The 2021 Snowmass Energy Frontier panel wrote in its final report "The realization of a Higgs factory will require an immediate, vigorous and targeted detector R&D program". Both linear and circular $e^+e^-$ collider efforts have developed a conceptual design for their detectors and are aggressively pursuing a path to formalize these detector concepts. The U.S. has world-class expertise in particle detectors, and is eager to play a leading role in the next generation $e^+e^-$ collider, currently slated to become operational in the 2040s. It is urgent that the U.S. organize its efforts to provide leadership and make significant contributions in detector R&D. These investments are necessary to build and retain the U.S. expertise in detector R&D and future projects, enable significant contributions during the construction phase and maintain its leadership in the Energy Frontier regardless of the choice of the collider project. In this document, we discuss areas where the U.S. can and must play a leading role in the conceptual design and R&D for detectors for $e^+e^-$ colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments Execution Plan (IER-518 CED-3a)

As part of the experiment design and planning, the critical experiment design team (CEDT), as well as additional stakeholders, convened a series of meetings to discuss the goals and requirements of execution for this experiment. The slides from these meetings are attached in Appendix A. The following sections summarize the outcome of those discussions and present the planned experimental configurations and measurements. The stated goals of this experiment are as follows: 1) Measure time-tagged list-mode data for configurations exceeding neutron multiplication of 100; 2) Provide intercomparison between LLNL, LANL, and IRSN detector systems and methodologies; 3) Generate experiment execution report(s) useful to a fundamental physics benchmark for the ICSBEP; 4) Leverage existing critical experiment and detector system benchmarks to limit required modeling and uncertainty analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Interactive 4D-STEM Phase-Contrast Imaging From Electron Event Representation Data: Less computation with the right representation

The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.

4D-STEM↗

AI-assisted optimization of the ECCE tracking system at the Electron Ion Collider

The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the “glue” that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5 T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Herein our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Determining spectral response of the National Ignition Facility particle time of flight diagnostic to x rays

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond detector used for measuring multiple nuclear bang times at the National Ignition Facility. Due to the non-trivial, polycrystalline structure of these detectors, individual characterization and measurement are required to interrogate the sensitivity and behavior of charge carriers. In this paper, a process is developed for determining the x-ray sensitivity of PTOF detectors and relating it to the intrinsic properties of the detector. We demonstrate that the diamond sample measured has a significant non-homogeneity in its properties, with the charge collection well described by a linear model ax + b, where a = 0.63 ± 0.16 V –1 mm –1 and b = 0.00 ± 0.04 V –1 . Finally, we also use this method to confirm an electron to hole mobility ratio of 1.5 ± 1.0 and an effective bandgap of 1.8 eV rather than the theoretical 5.5 eV, leading to a large sensitivity increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ATHENA detector proposal—a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.

47 OTHER INSTRUMENTATION↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CMS Experience with Adoption of the Community supported DD4hep Toolkit

DD4hep is an open-source software toolkit that provides comprehensive and complete generic detector descriptions for high energy physics (HEP) detectors. The Compact Muon Solenoid collaboration (CMS) has recently evaluated and adopted DD4hep to replace its custom detector description software. CMS has demanding software requirements as a very large, longrunning experiment that must support legacy geometries and study many possible upgraded detector designs of a constantly evolving detector that will be taking data for many years to come. CMS has chosen DD4hep since it is a high-quality, community-supported solution that will benefit from continuing modernization and maintenance. This presentation will discuss the issues of DD4hep adoption, the advantages and disadvantages of the various design choices, performance results, and the integration of the plugin systems from CMS and Gaudi, another open-source software framework. Recommendations about DD4hep based upon the CMS use cases will also be presented.

Vuosalo, Carl↗