Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Differential cross-section measurements of the production of four charged leptons in association with two jets using the ATLAS detector

Differential cross-sections are measured for the production of four charged leptons in association with two jets. These measurements are sensitive to final states in which the jets are produced via the strong interaction as well as to the purely-electroweak vector boson scattering process. The analysis is performed using proton-proton collision data collected by ATLAS at $\sqrt{s}$ = 13 TeV and with an integrated luminosity of 140 fb –1 . The data are corrected for the effects of detector inefficiency and resolution and are compared to state-of-the-art Monte Carlo event generator predictions. The differential cross-sections are used to search for anomalous weak-boson self-interactions that are induced by dimension-six and dimension-eight operators in Standard Model effective field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the polarisation of W bosons produced in top-quark decays using dilepton events at $\sqrt{s}$ = $13$ TeV with the ATLAS experiment

A measurement of the polarisation of W bosons produced in top-quark decays is presented, using proton–proton collision data at a centre-of-mass energy of $\sqrt{s}$ = $13$ TeV. The data were collected by the ATLAS detector at the Large Hadron Collider and correspond to an integrated luminosity of 139 fb -1 . The measurement is performed selecting $t$$\overline{t}$ events decaying into final states with two charged leptons (electrons or muons) and at least two b-tagged jets. The polarisation is extracted from the differential cross-section distribution of the cos$⁡θ$* variable, where $θ$* is the angle between the momentum direction of the charged lepton from the W boson decay and the reversed momentum direction of the b-quark from the top-quark decay, both calculated in the W boson rest frame. Parton-level results, corrected for the detector acceptance and resolution, are presented for the cos⁡θ* angle. The measured fractions of longitudinal, left- and right-handed polarisation states are found to be $f$ 0 = 0.684 ± 0.005 (stat.) ± 0.014 (syst.), $f$ L = 0.318 ± 0.003 (stat.) ± 0.008 (syst.) and $f$ R = -0.002 ± 0.002 (stat.) ± 0.014 (syst.), in agreement with the Standard Model prediction.

43 PARTICLE ACCELERATORS↗

Evaluating Linear Ion Trap for MS3-Based Multiplexed Single-Cell Proteomics

There is a growing demand to develop high-throughput and high-sensitivity mass spectrometry methods for single-cell proteomics. The commonly used isobaric labeling-based multiplexed single-cell proteomics approach suffers from distorted protein quantification due to co-isolated interfering ions during MS/MS fragmentation, also known as ratio compression. We reasoned that the use of MS3-based quantification could mitigate ratio compression and provide better quantification. However, previous studies indicated reduced proteome coverages in the MS3 method, likely due to long duty cycle time and ion losses during multilevel ion selection and fragmentation. Here, in this paper, we described an improved MS acquisition method for MS3-based single-cell proteomics by employing a linear ion trap to measure reporter ions. We demonstrated that linear ion trap can increase the proteome coverages for single-cell-level peptides with even higher gain obtained via the MS3 method. The optimized real-time search MS3 method was further applied to study the immune activation of single macrophages. Among a total of 126 single cells studied, over 1200 and 1000 proteins were quantifiable when at least 50 and 75% nonmissing data were required, respectively. Our evaluation also revealed several limitations of the low-resolution ion trap detector for multiplexed single-cell proteomics and suggested experimental solutions to minimize their impacts on single-cell analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The contribution of Compton ionization to ultrafast x-ray scattering

We investigate the role of Compton ionization in ultrafast non-resonant x-ray scattering using a molecular model system, which includes the ionization continuum via an orthonormalized plane wave ansatz. Elastic and inelastic components of the scattering signal, as well as coherent-mixed scattering that arises from electron dynamics, are calculated. By virtue of a near-quantitative distinction between scattering related to electronic transitions into bound and continuum states, we demonstrate how Compton ionization contributes to the coherent-mixed component. Analogous to inelastic scattering, the contribution to the coherent-mixed signal is significant and particularly manifests at intermediate and high-momentum transfers. Strikingly, for molecules with inversion symmetry, the exclusion of bound or continuum transitions may lead to the prediction of spurious coherent-mixed signals. We conclude that qualitative and quantitative accuracies of predicted scattering signals on detectors without energy resolution require that elements of the two-electron density operator are used. This approach inherently accounts for all accessible electronic transitions, including ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of flexible proton beam imaging energy spectrometers (PROBIES)

A simple repeating step-filtered structure has been designed and deployed for the detection of MeV-energy proton beams produced from high-intensity short-pulse laser-driven experiments. Due to the diagnostic's ability to recover energy-resolved images of proton beams, it is called the proton beam imager and energy spectrometer (or PROBIES). The flexible design has two useful applications. First, it can be fielded in a configuration with a scintillator and imaging setup in order to collect proton beam information in high-repetition rate experiments. Here we show a configuration that collects the equivalent of a nine-film radiochromic film (RCF) stack, and a technique for using a neural network (NN) to rapidly analyze the images on millisecond time-scales. Second, when using RCF stacks as the detector, the energy resolution capability is greatly increased compared to traditional RCF stacks, while simultaneously reducing the total number of films required to make each measurement. We demonstrate a configuration that provides up to 90 spatially- and energy-resolved datapoints using just ten films. Both designs presented here can be easily customized for anticipated experimental outputs and manufactured at low cost. Such designs allow for rapid prototyping using modern high-accuracy 3D printers or on-demand computer numerical control machining to reduce the reliance on time-consuming film media, analysis, or bulky electro-magnetically dispersing spectrometers. The analysis of data is discussed and a methodology for constructing a NN that is capable of rapidly analyzing data on-the-fly with greater than 95% accuracy is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical considerations for measuring global spin density matrix elements of vector mesons in heavy-ion collisions

The STAR Collaboration has reported a significant 𝜙-meson global spin alignment (𝜌 00 ) signal in Au+Au collisions at $\sqrt{s_{NN}}$ ≤ 62 GeV by measuring the polar angle distribution of 𝜙-meson daughters with respect to the orbital angular momentum direction of the collision system. Here, in this paper, a new method is explored for studying vector-meson global spin alignment in heavy-ion collisions by examining the two-dimensional (2D) polar and azimuthal angle distribution. This method allows simultaneous extraction of 𝜌 00 and off-diagonal spin density matrix elements (SDMEs), providing unique access to local quark-antiquark spin correlations and spin hydrodynamics in quark-gluon plasma. The new 2D method also removes potential biases from nonzero off-diagonal SDMEs on 𝜌 00 with the 1D method. A detailed procedure to correct for detector acceptance and resolution effects is also presented and validated by simulation studies.

Wilks, Gavin [University of Illinois, Chicago, IL ↗

Integrated and differential fiducial cross-section measurements for the vector boson fusion production of the Higgs boson in the $H → WW^* → evμv$ decay channel at 13 TeV with the ATLAS detector

The vector-boson production cross-section for the Higgs boson decay in the H→WW*→eνμν channel is measured as a function of kinematic observables sensitive to the Higgs boson production and decay properties as well as integrated in a fiducial phase space. The analysis is performed using the proton-proton collision data collected by the ATLAS detector in Run 2 of the LHC at $\sqrt{s}$=13 TeV center-of-mass energy corresponding to an integrated luminosity of 139 fb -1 . The different flavor final state is studied by selecting an electron and a muon originating from a pair of W bosons and compatible with the Higgs boson decay. The data are corrected for the effects of detector inefficiency and resolution, and the measurements are compared with different state-of-the-art theoretical predictions. The differential cross-sections are used to constrain anomalous interactions described by dimension-six operators in an Effective Field Theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental realization of neutron helical waves

Methods of preparation and analysis of structured waves of light, electrons, and atoms have been advancing rapidly. Despite the proven power of neutrons for material characterization and studies of fundamental physics, neutron science has not been able to fully integrate these techniques because of small transverse coherence lengths, the relatively poor resolution of spatial detectors, and low fluence rates. Here, we demonstrate methods that are practical with the existing technologies and show the experimental achievement of neutron helical wavefronts that carry well-defined orbital angular momentum values. We discuss possible applications and extensions to spin-orbit correlations and material characterization techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Differential cross-section measurements for the electroweak production of dijets in association with a Z boson in proton–proton collisions at ATLAS

Differential cross-section measurements are presented for the electroweak production of two jets in association with a Z boson. These measurements are sensitive to the vector-boson fusion production mechanism and provide a fundamental test of the gauge structure of the Standard Model. The analysis is performed using proton–proton collision data collected by ATLAS at √s=13 TeV and with an integrated luminosity of 139 fb -1 . The differential cross-sections are measured in the Z→ℓ + ℓ - decay channel (ℓ=e,μ) as a function of four observables: the dijet invariant mass, the rapidity interval spanned by the two jets, the signed azimuthal angle between the two jets, and the transverse momentum of the dilepton pair. The data are corrected for the effects of detector inefficiency and resolution and are sufficiently precise to distinguish between different state-of-the-art theoretical predictions calculated using Powheg+Pythia8, Herwig7+Vbfnlo and Sherpa 2.2. The differential cross-sections are used to search for anomalous weak-boson self-interactions using a dimension-six effective field theory. The measurement of the signed azimuthal angle between the two jets is found to be particularly sensitive to the interference between the Standard Model and dimension-six scattering amplitudes and provides a direct test of charge-conjugation and parity invariance in the weak-boson self-interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Gaussian process for calibration and control of GlueX Central Drift Chamber

We have developed and implemented a machine learning based system to calibrate and control the GlueX Central Drift Chamber at Jefferson Lab, VA, in near real-time. The system monitors environmental and experimental conditions during data taking and uses those as inputs to a Gaussian process (GP) with learned prior. The GP predicts calibration constants in order to recommend a high voltage (HV) setting for the detector that maintains consistent detector performance (gain and resolution) throughout data taking. This approach is in stark contrast to traditional detector operations in which the detector operates at fixed HV and its calibration parameters vary quite considerably with time. Additionally, the ML based system utilizes uncertainty quantification to correct the recommended control parameters when appropriate. We will present results from the ML system autonomously during the Charged Pion Polarizability (CPP) experiment conducted in Hall D at Jefferson Lab.

McSpadden, Helen↗

Determining the 193 m Ir/ 192 Ir ratio from high-resolution X-ray measurements

Two pellets of iridium salt were irradiated at the center of the Flattop critical assembly, one at low neutron flux and the other at high flux. After that two counting samples were prepared from each pellet following a given chemical procedure. Measurements of the four counting samples were carried out with two high-resolution silicon drift detectors for over a year. Pulse height spectra of the L→M X-rays from 193 m Ir and 192 Ir were approximated with a Voigt function and the ratio of produced 193 m Ir and 192 Ir nuclei obtained. The 193 m Ir/ 192 Ir ratios from each measured spectrum are compared to identify possible systematic deviations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Heavy Flavor Physics at the EIC with the ECCE detector

The proposed Electron-Ion Collider (EIC) will operate high-energy high-luminosity electron+proton and electron+nucleus collisions to solve several unresolved fundamental questions. Due to their large masses (mc,b > ΛQCD), heavy quarks and their hadron products are ideal probes to study the nucleon/nuclear parton distribution functions in the high Bjorken-x (xBJ > 0.1) region and explore the hadronization process within the unconstrained kinematic region. Recently, the Electron-Ion Collider Comprehensive Chromodynamics Experiment (ECCE) consortium detector conceptual design has been selected as the reference design for the EIC project detector. The precise momentum and spatial resolutions provided by the ECCE tracking detector enable a series of open heavy flavor and quarkonia measurements. The physics projections of these proposed heavy flavor measurements in simulation studies using the ECCE detector design will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IGRINS RV: A Precision Radial Velocity Pipeline for IGRINS Using Modified Forward Modeling in the Near-infrared

Application of the radial velocity (RV) technique in the near-infrared is valuable because of the diminished impact of stellar activity at longer wavelengths, making it particularly advantageous for the study of late-type stars but also for solar-type objects. In this paper, we present the IGRINS RV open-source python pipeline for computing infrared RV measurements from reduced spectra taken with IGRINS, an R ≡ λ/Δλ ∼ 45,000 spectrograph with simultaneous coverage of the H band (1.49–1.80 μm) and K band (1.96–2.46 μm). Using a modified forward-modeling technique, we construct high-resolution telluric templates from A0 standard observations on a nightly basis to provide a source of common-path wavelength calibration while mitigating the need to mask or correct for telluric absorption. Telluric standard observations are also used to model the variations in instrumental resolution across the detector, including a yearlong period when the K band was defocused. Without any additional instrument hardware, such as a gas cell or laser frequency comb, we are able to achieve precisions of 26.8 m s{sup −1} in the K band and 31.1 m s{sup −1} in the H band for narrow-line hosts. These precisions are empirically determined by a monitoring campaign of two RV standard stars, as well as the successful retrieval of planet-induced RV signals for both HD 189733 and τ Boo A; furthermore, our results affirm the presence of the Rossiter–McLaughlin effect for HD 189733. The IGRINS RV pipeline extends another important science capability to IGRINS, with publicly available software designed for widespread use.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gaussian process for calibration and control of GlueX Central Drift Chamber

We have developed and implemented a machine learning based system to calibrate and control the GlueX Central Drift Chamber at Jefferson Lab, VA, in near real-time. The system monitors environmental and experimental conditions during data taking and uses those as inputs to a Gaussian process (GP) with learned prior. The GP predicts calibration constants in order to recommend a high voltage (HV) setting for the detector that maintains consistent detector performance (gain and resolution) throughout data taking. This approach is in stark contrast to traditional detector operations in which the detector operates at fixed HV and its calibration parameters vary quite considerably with time. Additionally, the ML based system utilizes uncertainty quantification to correct the recommended control parameters when appropriate. We will present results from the ML system autonomously during the Charged Pion Polarizability (CPP) experiment conducted in Hall D at Jefferson Lab.

McSpadden, Helen↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle hit clustering and identification using point set transformers in liquid argon time projection chambers

Liquid argon time projection chambers are often used in neutrino physics and dark-matter searches because of their high spatial resolution. The images generated by these detectors are extremely sparse, as the energy values detected by most of the detector are equal to 0, meaning that despite their high resolution, most of the detector is unused in a particular interaction. Instead of representing all of the empty detections, the interaction is usually stored as a sparse matrix, a list of detection locations paired with their energy values. Traditional machine learning methods that have been applied to particle reconstruction such as convolutional neural networks (CNNs), however, cannot operate over data stored in this way and therefore must have the matrix fully instantiated as a dense matrix. Operating on dense matrices requires a lot of memory and computation time, in contrast to directly operating on the sparse matrix. We propose a machine learning model using a point set neural network that operates over a sparse matrix, greatly improving both processing speed and accuracy over methods that instantiate the dense matrix, as well as over other methods that operate over sparse matrices. Compared to competing state-of-the-art methods, our method improves classification performance by 14%, segmentation performance by more than 22%, while taking 80% less time and using 66% less memory. Compared to state-of-the-art CNN methods, our method improves classification performance by more than 86%, segmentation performance by more than 71%, while reducing runtime by 91% and reducing memory usage by 61%.

calibration and fitting methods↗