Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Imaging nanoscale lattice variations by machine learning of x-ray diffraction microscopy data

In this paper, we present a novel methodology based on machine learning to extract lattice variations in crystalline materials, at the nanoscale, from an x-ray Bragg diffraction-based imaging technique. By employing a full-field microscopy setup, we capture real space images of materials, with imaging contrast determined solely by the x-ray diffracted signal. The data sets that emanate from this imaging technique are a hybrid of real space information (image spatial support) and reciprocal lattice space information (image contrast), and are intrinsically multidimensional (5D). By a judicious application of established unsupervised machine learning techniques and multivariate analysis to this multidimensional data cube, we show how to extract features that can be ascribed physical interpretations in terms of common structural distortions, such as lattice tilts and dislocation arrays. Finally, we demonstrate this 'big data' approach to x-ray diffraction microscopy by identifying structural defects present in an epitaxial ferroelectric thin-film of lead zirconate titanate.

36 MATERIALS SCIENCE↗

Analyzer-based x-ray phase-contrast microscopy combining channel-cut and asymmetrically cut crystals

An analyzer-based x-ray phase-contrast microscopy (ABM) setup combining a standard analyzer-based x-ray phase-contrast imaging (ABI) setup [nondispersive 4-crystal setup (Bonse-Hart setup)] and diffraction by asymmetrically cut crystals is presented here. An attenuation-contrast microscopy setup with conventional x-ray source and asymmetrically cut crystals is first analyzed. Edge-enhanced effects attributed to phase jumps or refraction/total external reflection on the fiber borders were detected. However, the long exposure times and the possibility to achieve high contrast microscopies by using extremely low attenuation-contrast samples motivated us to assemble the ABM setup using a synchrotron source. This setup was found to be useful for low contrast attenuation samples due to the low exposure time, high contrast, and spatial resolution found. Moreover, thanks to the combination with the nondispersive ABI setup, the diffraction-enhanced x-ray imaging algorithm could be applied.

36 MATERIALS SCIENCE↗

Liquid Structure of Shock-Compressed Hydrocarbons at Megabar Pressures

We present here results for the ionic structure in hydrocarbons (polystyrene, polyethylene) that were shock compressed to pressures of up to 190 GPa, inducing rapid melting of the samples. The structure of the resulting liquid is then probed using in situ diffraction by an x-ray free electron laser beam, demonstrating the capability to obtain reliable diffraction data in a single shot, even for low-Z samples without long range order. The data agree well with ab initio simulations, validating the ability of such approaches to model mixed samples in states where complex interparticle bonds remain, and showing that simpler models are not necessarily valid. While the results clearly exclude the possibility of complete carbon-hydrogen demixing at the conditions probed, they also, in contrast to previous predictions, indicate that diffraction is not always a sufficient diagnostic for this phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of volume-weighted average grain size in Fe-based nanocrystalline soft magnetic materials by autocorrelation function

Highlights: • Normalized ACF of TEM images estimates the volume-weighted average grain size. • Grain size estimation by normalized ACF shows good accuracy and time efficiency. • Normalized ACF can reveal grain size difference in different areas of a TEM sample. • Normalized ACF helps modelling of grain size distributions in Fe-B nanostructures. - Abstract: The coercivity of Fe-based nanocrystalline soft magnetic materials depends critically on the grain size of bcc-Fe grains. Accurately estimating the volume-weighted mean grain size is extremely important to develop new Fe-based nanocrystalline soft magnetic materials with low coercivity. This article shows that autocorrelation analysis of dark-field transmission electron microscope (TEM) images provides a very good estimation of bcc-Fe grain size in nanocrystalline soft magnetic materials. This method can be used to efficiently estimate the volume-weighted average grain size from multiple TEM images with much less inherent bias than manual measurement techniques. The estimated grain sizes show good consistency to the grain sizes estimated by X-ray diffraction (XRD) and manual measurement. In contrast to XRD, this method can also reveal the differences in grain size from different micron-sized regions of a sample.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of crystallographic orientation and applied magnetic field on domain structure in duplex stainless steel studied using magnetic force microscopy

Highlights: • Ferrite phase in a duplex stainless steel consists of stripe type domains. • Domain contrast decreases with deviation of plane normal from <100>. • Domain width increases with deviation of plane normal from <100>. • Domain alignment with applied field observed along <100> directions. • Grain boundary stray field is a function of misorientation between grains. - Abstract: The paper investigates the local micro-magnetization behavior in duplex stainless steel (DSS) using magnetic force microscopy (MFM). DSS has equal amount of austenite phase in ferrite matrix. The MFM imaging clearly differentiates ferrite phase (ferromagnetic) from the austenite phase (paramagnetic) due to the maze type magnetic domains present in the ferrite phase. The magneto crystalline anisotropic effect on the domain structure is discussed with the support of electron backscatter diffraction (EBSD) measurements. The MFM phase contrast and domain width are correlated with the orientation of surface normal with respect to the easy axis of magnetization (<100>). The influence of external magnetic field (±127 kA/m) application on the domain structure is studied as a function of the grain orientation and the leakage field at the grain boundaries is analyzed based on the mis-orientation between the grains.

36 MATERIALS SCIENCE↗

Epitaxial V{sub 0.6}W{sub 0.4}N/MgO(001): Evidence for ordering on the cation sublattice

V{sub 0.6}W{sub 0.4}N alloys are grown on MgO(001) by ultrahigh vacuum reactive magnetron sputtering from V and W targets in 10 mTorr pure-N{sub 2} atmospheres at temperatures T{sub s} ranging from 600 to 900 Degree-Sign C. Based on x-ray diffraction and transmission electron microscopy results, all films have the B1-NaCl crystal structure and grow with a cube-on-cube epitaxial relationship to the substrate, (001){sub VWN} Double-Vertical-Line (001){sub MgO} and [100]{sub VWN} Double-Vertical-Line [100]{sub MgO}. Rutherford backscattering spectrometry analyses show that the N content in V{sub 0.6}W{sub 0.4}N{sub x} alloys decreases with increasing T{sub s} from overstoichiometric with x = 1.13 at 600 Degree-Sign C, to approximately stoichiometric with x = 1.08 at 700 Degree-Sign C, to understoichiometric at 800 Degree-Sign C (x = 0.80) and 900 Degree-Sign C (x = 0.75). High-resolution scanning transmission electron microscopy, Z-contrast, and selected-area electron diffraction investigations of V{sub 0.6}W{sub 0.4}N(001) alloys grown at 600 and 700 Degree-Sign C reveal the onset of W ordering on adjacent 111 planes of the metal sublattice; no ordering is observed for understoichiometric films grown at higher temperatures.

36 MATERIALS SCIENCE↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

Rapid misfit dislocation characterization in heteroepitaxial III-V/Si thin films by electron channeling contrast imaging

Electron channeling contrast imaging (ECCI) is used to characterize misfit dislocations in heteroepitaxial layers of GaP grown on Si(100) substrates. Electron channeling patterns serve as a guide to tilt and rotate sample orientation so that imaging can occur under specific diffraction conditions. This leads to the selective contrast of misfit dislocations depending on imaging conditions, confirmed by dynamical simulations, similar to using standard invisibility criteria in transmission electron microscopy (TEM). The onset and evolution of misfit dislocations in GaP films with varying thicknesses (30 to 250 nm) are studied. This application simultaneously reveals interesting information about misfit dislocations in GaP/Si layers and demonstrates a specific measurement for which ECCI is preferable versus traditional plan-view TEM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

Origins of ferromagnetism in transition-metal doped Si

We present results of the magnetic, structural, and chemical characterizations of Mn{sup +}-implanted Si displaying n-type semiconducting behavior and ferromagnetic ordering with Curie temperature, T{sub C}, well above room temperature. The temperature-dependent magnetization measured by superconducting quantum interference device from 5 to 800 K was characterized by three different critical temperatures (T{sub C}*{approx}45 K, T{sub C1}{approx}630-650 K, and T{sub C2}{approx}805-825 K). Their origins were investigated using dynamic secondary ion mass spectroscopy and transmission electron microscopy (TEM) techniques, including electron energy loss spectroscopy, Z-contrast scanning TEM imaging, and electron diffraction. We provided direct evidences of the presence of a small amount of Fe and Cr impurities which were unintentionally doped into the samples together with the Mn{sup +} ions as well as the formation of Mn-rich precipitates embedded in a Mn-poor matrix. The observed T{sub C}* is attributed to the Mn{sub 4}Si{sub 7} precipitates identified by electron diffraction. Possible origins of T{sub C1} and T{sub C2} are also discussed. Our findings raise questions regarding the origin of the high-T{sub C} ferromagnetism reported in many material systems without a careful chemical analysis.

36 MATERIALS SCIENCE↗

Origin of enhanced magnetization in rare earth doped multiferroic bismuth ferrite

We report structural and magnetic properties of rare earth doped Bi{sub 0.95}R{sub 0.05} FeO{sub 3} (R = Y, Ho, and Er) submicron particles. Rare earth doping enhances the magnetization and the magnetization shows an increasing trend with decreasing dopant ionic radii. In contrast to the x-ray diffraction pattern, we have seen a strong evidence for the presence of rare earth iron garnets R{sub 3}Fe{sub 5}O{sub 12} in magnetization measured as a function of temperature, in selected area electron diffraction, and in Raman measurements. Our results emphasised the role of secondary phases in the magnetic property of rare earth doped BiFeO{sub 3} compounds along with the structural distortion favoring spin canting by increase in Dzyaloshinskii-Moriya exchange energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of the rare-earth element on the effects of the structural and magnetic phase transitions in CeFeAsO, PrFeAsO, and NdFeAsO

We present results of transport and magnetic properties and heat capacity measurements on polycrystalline CeFeAsO, PrFeAsO and NdFeAsO. These materials undergo structural phase transitions, spin density wave-like magnetic ordering of small moments on iron and antiferromagnetic ordering of rare-earth moments. The temperature dependence of the electrical resistivity, Seebeck coefficient, thermal conductivity, Hall coefficient and magnetoresistance are reported. The magnetic behavior of the materials have been investigated using Moessbauer spectroscopy and magnetization measurements. Transport and magnetic properties are affected strongly by the structural and magnetic transitions, suggesting significant changes in the band structure and/or carrier mobilities occur, and phonon-phonon scattering is reduced upon transformation to the low-temperature structure. Results are compared with recent reports for LaFeAsO, and systematic variations in properties as the identity of Ln is changed are observed and discussed. As Ln progresses across the rare-earth series from La to Nd, an increase in the hole contributions to the Seebeck coefficient and increases in magnetoresistance and the Hall coefficient are observed in the low-temperature phase. Analysis of hyperfine fields at the iron nuclei determined from Moessbauer spectra indicates that the moment on Fe in the orthorhombic phase is nearly independent of the identity of Ln, in apparent contrast to reports of powder neutron diffraction refinements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The use of a mini-κ goniometer head in macromolecular crystallography diffraction experiments

Hardware and software solutions for MX data-collection strategies using the EMBL/ESRF miniaturized multi-axis goniometer head are presented. Most macromolecular crystallography (MX) diffraction experiments at synchrotrons use a single-axis goniometer. This markedly contrasts with small-molecule crystallography, in which the majority of the diffraction data are collected using multi-axis goniometers. A novel miniaturized κ-goniometer head, the MK3, has been developed to allow macromolecular crystals to be aligned. It is available on the majority of the structural biology beamlines at the ESRF, as well as elsewhere. In addition, the Strategy for the Alignment of Crystals (STAC) software package has been developed to facilitate the use of the MK3 and other similar devices. Use of the MK3 and STAC is streamlined by their incorporation into online analysis tools such as EDNA. The current use of STAC and MK3 on the MX beamlines at the ESRF is discussed. It is shown that the alignment of macromolecular crystals can result in improved diffraction data quality compared with data obtained from randomly aligned crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Micro-structural characterization of materials using synchrotron hard X-ray imaging techniques

X-ray imaging has been an important tool to study the materials microstructure with the laboratory based sources however the advent of third generation synchrotron sources has introduced new concepts in X-ray imaging such as phase contrast imaging, micro-tomography, fluorescence imaging and diffraction enhance imaging. These techniques are being used to provide information of materials about their density distribution, porosity, geometrical and morphological characteristics at sub-micron scalewith improved contrast. This paper discusses the development of various imaging techniques at synchrotron based imaging beamline Indus-2 and few recent experiments carried out at this facility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction

Coherent x-ray diffraction microscopy is a lensless phase-contrast imaging technique with high image contrast. Although electron tomography allows intensive study of the three-dimensional structure of cellular organelles, it has inherent difficulty with thick objects. X rays have the unique benefit of allowing noninvasive analysis of thicker objects and high spatial resolution. We observed an unstained human chromosome using coherent x-ray diffraction. The reconstructed images in two or three dimensions show an axial structure, which has not been observed under unstained conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Structure of Cu in Cs8Na16Cu5Ge131 Type II Clathrate

We have used X-ray absorption spectroscopy (XAS) to investigate the local structure of Cu and Ge in the Cs8Na16Cu5Ge131 type II clathrate. We show that the local structure parameters for Ge (coordination number and distances) are consistent with those derived on the basis of XRD investigation of Cs8Na16Ge136. The EXAFS data suggest that Cu either randomly substitutes for Ge on the clathrate framework or preferentially on the 96g site but not preferentially on the 32e or 8a sites (Wyckoff notation). Furthermore, we find that the Cu-Ge distance is smaller than the Ge-Ge distance by 0.13 Angstroms, indicating a local distortion around the Cu atoms. The estimated degrees of disorder for Cu-Ge and Ge-Ge interactions indicate the Cu-Ge clathrate framework to be relatively stiff, while those for Na-Ge and Cs-Ge interactions corroborate previous observations of strong thermal disorder of the alkali guests in these materials. Our XAS results offer insight into the site substitution of Cu in this material, information unattainable from X-ray diffraction due to the lack of scattering contrast between Cu and Ge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Diffraction-Enhanced Imaging

Diffraction-enhanced imaging (DEI) is a new x-ray imaging modality that has been shown to enhance contrast between normal and cancerous breast tissues. In this study, diffraction-enhanced imaging in computed tomography (DEI-CT) mode was used to quantitatively characterize the refraction contrasts of the organized structures associated with invasive human breast cancer. Using a high-sensitivity Si (3 3 3) reflection, the individual features of breast cancer, including masses, calcifications and spiculations, were observed. DEI-CT yields 14, 5 and 7 times higher CT numbers and 10, 9 and 6 times higher signal-to-noise ratios (SNR) for masses, calcifications and spiculations, respectively, as compared to conventional CT of the same specimen performed using the same detector, x-ray energy and dose. Furthermore, DEI-CT at ten times lower dose yields better SNR than conventional CT. In light of the recent development of a compact DEI prototype using an x-ray tube as its source, these results, acquired at a clinically relevant x-ray energy for which a pre-clinical DEI prototype currently exists, suggest the potential of clinical implementation of mammography with DEI-CT to provide high-contrast, high-resolution images of breast cancer (Parham 2006 PhD Dissertation University of North Carolina at Chapel Hill).

47 OTHER INSTRUMENTATION↗