Amorphous silicon carbide coatings for extreme ultraviolet optics

Amorphous silicon carbide films formed by sputtering techniques are shown to have high reflectance in the extreme ultraviolet spectral region. X-ray scattering verifies that the atomic arrangements in these films are amorphous, while Auger electron spectroscopy and Rutherford backscattering spectroscopy show that the films have composition close to stoichiometric SiC, although slightly C-rich, with low impurity levels. Reflectance vs incidence angle measurements from 24 to 1216 A were used to derive optical constants of this material, which are presented here. Additionally, the measured extreme ultraviolet efficiency of a diffraction grating overcoated with sputtered amorphous silicon carbide is presented, demonstrating the feasibility of using these films as coatings for EUV optics.

Kortright, J. B.↗

ORFEUS focal plane instrumentation: The Berkeley spectrometer

A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

Hurwitz, Mark↗

Experimental results of a high Q quasioptical reflection cavity

A quasi-optical reflection cavity intended to be used as the resonant load of a submillimeter wavelength oscillator has been designed, constructed, and tested. The resonator consists of three elements in cascade: a high Q, high finesse folded Fabry-Perot resonator, a lower Q, low finesse Fabry-Perot resonator, and a Littrow mounted diffraction grating. The resonator exhibits a Q of 6600 and 2.5 dB of loss at 63 GHz. The design can be scaled to 1 THz, where waveguide structures become impractical, to serve as the resonator for high frequency quantum well resonant tunneling device oscillators.

Lee, Karen A.↗

Measuring Monodisperse Small Particles En Masse

New optical method enables determination of sizes of approximately-micron-sized particles. Arrays of particles act as diffraction gratings. Simple and inexpensive apparatus replaces high-magnification microscopes in measurements of diameters of small polystyrene latex spheres. Device being used to determine monodispersity and diameters of polystyrene latex microspheres used as seeding material for laser-velocimetry flow measurements in NASA's wind tunnels. Characterization of particle sizes important in wide range of fields, including manufacture of plastics and ceramics, biochemistry, and medicine.

Bruce, Robert A.↗

New measurements of the far ultraviolet scattering properties of interstellar dust

An analysis is presented for the spectra of the diffuse ultraviolet background taken during shuttle flight STS-61C (January 1986). Eight regions of the sky were observed for approximately 20 minutes each, using a spectrograph designed specifically to perform measurements of the UV background. The field of view was 3.8 deg x 8 min, with imaging along the slit to confine stellar contamination. The instrument featured a shutter mechanism to measure internal background during flight, a low-scatter holographically ruled diffraction grating, photon counting microchannel plate detectors, through baffling, and a crystal window to further attenuate stray light. The spectra covered the range 1400 to 1850 A and was binned in 50 A bands. The procedure for substracting the contribution of stars too faint to be detected as discrete sources during the observations (in general this represents a small fraction of the total intensity detected except at the longest wavelengths). A radiative transfer model used to interpret the data and set confidence intervals on the relevant parameters is described. It was found that the continuum component of the diffuse ultraviolet background arises primarily from two sources. One source is scattering of starlight by interstellar dust with an albedo of about 12 percent and a relatively isotropic phase function. A second source consists of about 150 photons/cm/sec/ster/A of extragalactic light which is attenuated by the dust in the galaxy. Although emission features possibly associated with molecular H2 are detected in one look direction, fluorescence of H2 is not a major contributor to the diffuse UV background, at least at galactic latitudes greater than -10 degrees.

Hurwitz, Mark↗

Dual-Passband Microwave Dichroic Plates

Perforated metal plate with dielectric-filled holes acts as dual-passband dichroic microwave plate. Use of dielectric enables use of smaller, more-closely-spaced holes, reducing undesired diffraction-grating lobes. Arrangement and sizes of holes, distances between them, and material and dimensions of dielectric plugs chosen to satisfy design requirements.

Otoshi, Tom Y.↗

Ruled and holographic experiment (AO 138-5)

The AO 138-5 experiment has been designed, via the French Cooperative Payload (FRECOPA) experiment with the aim to study the optical behavior of different diffraction gratings submitted to space vacuum long exposure and solar radiation. Samples were rules and holographic gratings, masters or replica, and some additional control mirrors with various coatings. The experiment was located on the B3, trailing edge of the Long Duration Exposure Facility (LDEF) and has been protected against atomic oxygen flux. The experienced thermal cycling has been evaluated from -23 C to 66 C during the flight, 34,000 orbits. The analysis has been focused on the triple point characterization including light efficiency, wavefront flatness quality and stray light level. Tests were conducted on control mirrors and gratings loaded but not exposed to cosmic dust or solar irradiations. They did not show any significant variations. Solar exposure has damaged the coating reflectivity in the ultraviolet region, the degradation is higher with the gratings, in terms of efficiency. However, wavefront flatness quality and stray light level tests revealed no additional changes.

Bonnemason, Francis↗

The Berkeley EUV spectrometer for ORFEUS

A novel EUV spectrometer is presented for the ORFEUS-SPAS mission. It uses a set of four varied line-space spherical diffraction gratings to obtain high-resolution spectra of point sources at wavelengths between 390 and 1200 A. The spectra are recorded with two detector units, each containing curved-surface microchannel plates and a delay-line anode-readout system. An independent optical system detects the image of the source in the entrance aperture and tracks the source as it drifts during an observation, enabling a reconstruction of the spectra postflight. The overall system performance is discussed and illustrated by synthetic spectra.

Hurwitz, M.↗

Effects of various cavity designs on the performance of a CO2 TEA laser with an unstable resonator

Unstable resonator modeling has been carried out for an injection-seeded CO2 transversely excited atmosphere (TEA) laser in the NOAA/ERL/Wave Propagation Laboratory (WPL) Doppler lidar to examine the effects of various cavity designs on the quality of the output beam. The results show the effects of an injection pinhole, electrode spacing, mirror tilt, and radial reflectivity function of the output coupler. The electrode spacing in this laser has negligible effect. The injection pinhole, however, produces complicated structures in the output patterns. If the pinhole is removed, the output pattern is much smoother, and the frequency jitter is smaller. Misalignment sensitivity is very closely related to the radial reflectivity function. The superparabolic function provides the highest coupling efficiency, largest beam size, and good collimation, but produces a slightly higher misalignment sensitivity compared with a parabolic function. The Gaussian function provides the lowest misalignment sensitivity, but it produces the smallest beam size and the largest beam divergence. Also, the coupling coefficient is 50 percent lower than the optimum value. Methods for using a flat diffraction grating in unstable resonators are also investigated. The best way is to use a flat grating/positive lens combination to replace the back concave mirror.

Zhao, Yanzeng↗

Self-Amplified Optical Pattern Recognizer

Self-amplified optical pattern recognizers developed for use in recognition of patterns, in optical computing, and in optoelectronic neural networks. In recognizer, photorefractive crystal serves as medium in which one holographically records diffraction-grating filter representing pattern with which recognition sought. Apparatus "self-amplified" because signal amplified within filter to many orders of magnitude greater than in prior optical pattern recognizers. Basic principle of operation applicable to many types of correlation filters, including (but not limited to) Vander Lugt matched filters, joint-transform filters, and phase-only filters.

Liu, Hua-Kuang↗

Research Studies on Advanced Optical Module/Head Designs for Optical Data Storage

Preprints are presented from the recent 1992 Optical Data Storage meeting in San Jose. The papers are divided into the following topical areas: Magneto-optical media (Modeling/design and fabrication/characterization/testing); Optical heads (holographic optical elements); and Optical heads (integrated optics). Some representative titles are as follow: Diffraction analysis and evaluation of several focus and track error detection schemes for magneto-optical disk systems; Proposal for massively parallel data storage system; Transfer function characteristics of super resolving systems; Modeling and measurement of a micro-optic beam deflector; Oxidation processes in magneto-optic and related materials; and A modal analysis of lamellar diffraction gratings in conical mountings.

Source record↗

A submillimeter tripler using a quasi-waveguide structure

A new type of frequency multiplier structure is being developed which is suitable for application at frequencies above 1 THz. This structure preserves some of the properties of waveguide for mode control, yet is not truly single mode. The device resembles a sectoral horn, with a varactor diode mounted near the throat. Input and output coupling are through the same aperture, requiring a quasi-optical diplexer. Initial tests are directed at building a tripler at 500 GHz, for comparison with waveguide structures. The diplexer is a blazed diffraction grating with appropriate focusing optics. Model studies show that the impedance match to a varactor should be good, and initial tests of the beam patterns of the prototype indicate that optical coupling efficiency should be very high. The structure also has the potential for use as a fundamental mixer, or as a third harmonic mixer.

Erickson, Neal R.↗

Ruled and holographic experiment (AO 138-5)

The AO 138-5 experiment was designed, via the FRECOPA (FRench COoperative PAyload) experiment with the aim to study the optical behavior of different diffraction gratings submitted to space vacuum long exposure and solar irradiation. Samples were ruled and holographic gratings, masters or replica, and some additional control mirrors with various coatings. The experiment was located on the B3, trailing edge of the LDEF and was protected against Atomic Oxygen flux. The experienced thermal cycling was evaluated from -23 C to 66 C during the flight, 34,000 orbits. The samples (two batches of four pieces) were located on a dedicated plate, by a pair of equivalent gratings or mirrors; optical faces were located on the external side. The plate was inside a canister, which had been opened in space for ten months. When the satellite returned to Kennedy Space Center, the remaining vacuum in the canister was still correct. The analysis focused on the triple point characterization including light efficiency, wavefront flatness quality and stray light level. Tests were conducted on control mirrors and gratings (rules and holographic master or replica) loaded but not exposed to cosmic dust or direct solar irradiations. They did not show any significant variations. Solar exposure had damaged the coating (aluminum and platinum) reflectivity in the Ultra-Violet region; the degradation is higher with the gratings, in terms of efficiency. However, wavefront flatness quality and stray light level tests revealed no additional changes.

Bonnemason, Francis↗

Design and initial performance evaluation of a portable short wave infrared spectroradiometer

The design, initial calibration, and performance evaluations of a portable short wave infrared (SWIR) spectroradiometer are described. The spectroradiometer covers the range from 1.1 to 2.5 microns with a spectral resolution that may be varied from less than 10 nm to more than 100 nm. A single spectrum is acquired in about 2 sec. The SNR is about 230 at a wavelength of 2.2 microns for a Lambertian surface of 90-percent reflectance illuminated by the sun at normal incidence with 14.8-nm resolution, a 25 C background temperature, and no atmospheric attenuation. FOV-defining optics are coupled by a flexible fiber-optics bundle to the spectroradiometer, which consists of a concave holographic diffraction grating with a flat focal field imaged onto a 1024-element platinum silicide linear-array detector.

Smith, Mark W.↗

Linear polarization sensitivity specifications for space-borne instruments

The radiometric accuracy of space-borne instruments such as radiometers and spectroradiometers which make measurements of the earth and other celestial objects can be compromised by the linear polarization sensitivity (LPS) induced by the optical system. Most of these optical systems contain optical elements whose reflectance or transmission is polarization dependent, such as diffraction gratings, folding and scanning mirrors, dichroic filters, and optical fibers. Optical system incorporating such elements generally display linear polarization sensitivity; different linear polarization states incident with equal radiometric power will be measured as different power levels. If the incident polarization state is unknown, the linear polarization sensitivity cannot be compensated during the data reduction. The light reflected from the earth and other planets and moons is usually partially linearly polarized, but in a random distribution. Thus, to make accurate radiometric measurements of these bodies, a radiometer or spectrometer should have a low level of linear polarization sensitivity. This paper contains a mathematical description of LPS, contains references to systems which have imposed a LPS specification, describes some of the sources of LPS, describes how to model LPS by polarization ray tracing, and discusses methods to reduce the LPS of an optical system.

Maymon, Peter W.↗

Diode laser stabilization

Center-frequency drift in diode lasers can be reduced by stabilizing the laser to an optical cavity with a low bandwidth feedback loop that acts on the injection current. Resonant optical feedback from a confocal or ring cavity can reduce high frequency noise, yielding linewidths in the 10 kHz range. With either an optical or an electronic lock to a cavity, the laser's wavelength is restricted to those regions that can be reached by temperature and current tuning of the solitary diode; this can be extended to full coverage by means of an extended cavity with a frequency-selective component, such as a diffraction grating.

Fox, R. W.↗

NASA airborne satellite instrumentation calibrator (NASIC) technical reference

The NASA Satellite Instrumentation Calibrator (NASIC) is a visible and near-infrared spectrometer used to calibrate various satellite instruments by underflying those instruments in a NASA ER-2 aircraft. The calibration instrument's hardware and software are documented. The design, operation, and function of an Ebert-Fastie monochronomator, which by means of a moveable diffraction grating, becomes a visible and near-infrared spectrometer used to calibrate satellite-borne instruments by high altitude underflights in the NASA ER-2.

Ward, John L.↗

Advanced optical instruments technology

The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

Shao, Mike↗