Search NASA⌕ Search

SEARCH · Search NASA

Results for “dual numbers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Magnetic dynamo action in two-dimensional turbulent magneto-hydrodynamics

Two-dimensional magnetohydrodynamic turbulence is explored by means of numerical simulation. Previous analytical theory, based on non-dissipative constants of the motion in a truncated Fourier representation, is verified by following the evolution of highly non-equilibrium initial conditions numerically. Dynamo action (conversion of a significant fraction of turbulent kinetic energy into long-wavelength magnetic field energy) is observed. It is conjectured that in the presence of dissipation and external forcing, a dual cascade will be observed for zero-helicity situations. Energy will cascade to higher wave numbers simultaneously with a cascade of mean square vector potential to lower wave numbers, leading to an omni-directional magnetic energy spectrum which varies as 1/k 3 at lower wave numbers, simultaneously with a buildup of magnetic excitation at the lowest wave number of the system. Equipartition of kinetic and magnetic energies is expected at the highest wave numbers in the system.

Fyfe, D.↗

Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements

The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.

Menyuk, N.↗

MEDSAT - A remote sensing satellite for malaria early warning and control

A remote sensing, medical satellite (MEDSAT) aids in the control of carrier (vector) borne disease. The prototype design is a light satellite to test for control of malaria. The design features a 340-kg satellite with visual/IR and SAR sensors in a low inclination orbit observing a number of worldwide test sites. The approach is to use four-band visual/IR and dual-polarized L-band SAR images obtained from MEDSAT in concert with in-situ data to estimate the temporal and spatial variations of malaria risk. This allows public health resources to focus on the most vulnerable areas at the appropriate time. It is concluded that a light-satellite design for a MEDSAT satellite with a Pegasus launch is feasible.

Vesecky, John↗

Space Biosensor Systems: Implications for Technology Transfer

To meet the need for continuous, automated monitoring of animal subjects, including; humans, during space flight, NASA is developing advanced physiologic sensor and biotelemetry system technologies. The ability to continuously track basic physiological parameters, such as heart rate, blood pH, and body temperature, in untethered subjects in space is a challenging task. At NASA's Ames Research Center, where a key focus is gravitational biology research, engineers have teamed with life scientists to develop wireless sensor systems for automated physiologic monitoring of animal models as small as the rat. This technology is also being adapted, in collaboration with medical professionals, to meet human clinical monitoring needs both in space and on the ground. Thus, these advanced monitoring technologies have important dual-use functions; they meet space flight data collection requirements and constraints, while concurrently addressing a number of monitoring and data acquisition challenges on the ground in areas of clinical monitoring and biomedical research. Additional applications for these and related technologies are being sought and additional partnerships established that enhance development efforts, reduce costs and facilitate technology infusion between the public and private sectors. This paper describes technology transfer and co-development projects that have evolved out of NASA's miniaturized, implantable chemical sensor development efforts.

Hines, J. W.↗

A Priori Analysis of Flamelet-Based Modeling for a Dual-Mode Scramjet Combustor

An a priori investigation of the applicability of flamelet-based combustion models to dual-mode scramjet combustion was performed utilizing Reynolds-averaged simulations (RAS). For this purpose, the HIFiRE Direct Connect Rig (HDCR) flowpath, fueled with a JP-7 fuel surrogate and operating in dual- and scram-mode was considered. The chemistry of the JP-7 fuel surrogate was modeled using a 22 species, 18-step chemical reaction mechanism. Simulation results were compared to experimentally-obtained, time-averaged, wall pressure measurements to validate the RAS solutions. The analysis of the dual-mode operation of this flowpath showed regions of predominately non-premixed, high-Damkohler number, combustion. Regions of premixed combustion were also present but associated with only a small fraction of the total heat-release in the flow. This is in contrast to the scram-mode operation, where a comparable amount of heat is released from non-premixed and premixed combustion modes. Representative flamelet boundary conditions were estimated by analyzing probability density functions for temperature and pressure for pure fuel and oxidizer conditions. The results of the present study reveal the potential for a flamelet model to accurately model the combustion processes in the HDCR and likely other high-speed flowpaths of engineering interest.

Quinlan, Jesse R.↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

Modeling of Transport Processes in Liquid-Metal Fusion Blankets: Past, Present, and Future

The successful development of robust breeding blanket systems will strongly rely on computational tools for predicting the complex behavior of the electrically conducting liquid-metal (LM) breeder flowing in the complex-shaped blanket ducts in the presence of a strong plasma-confining magnetic field, volumetric heating, and tritium generation. Associated transport processes involve magnetohydrodynamic (MHD) flows, heat transfer, corrosion, and tritium transport. This paper is an overview of past and present efforts in the development, application, and verification and validation (V&V) of such computational tools. As a result of the ongoing campaign on V&V of computer codes for LM blankets, the international fusion community has identified several candidates that promise to become real blanket design and analysis tools in the near future. Among them are HIMAG, MHD-UCAS, COMSOL Multiphysics, ANSYS FLUENT, ANSYS CFX, and OpenFOAM. The progress, over the last decade, in the application of such codes in blanket studies is tremendous. This is illustrated with two examples for a dual-coolant lead-lithium (DCLL) blanket: (1) integrated computer modeling for the recently designed DCLL blanket in the United States and (2) application of the code MHD-UCAS to the analysis of PbLi flows and heat transfer in a generic DCLL blanket prototype at high Hartmann (Ha ~ 10 4 ) and Grashof numbers (Gr ~ 10 12 ). Here, this paper also presents an approach to the development of a new integrated computational tool called the virtual dual-coolant lead-lithium (VDCLL) blanket, which elaborates the existing U.S. MHD code HIMAG.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Abort staging characteristics of an external oxygen tank separating from the space shuttle 040-A orbiter (.006 scale model) at Mach numbers of 0.6, 2.0, and 4.0

Experimental aerodynamic investigations were conducted on a .006 scale model of the space shuttle 040-A orbiter and its external fuel tank utilizing the NASA/MFSC dual sting support system in the MFSC 14 x 14 inch Trisonic Wind Tunnel. Normal force, pitching moment and axial force components were recorded simultaneously on the orbiter and the tank at selected tank field positions beneath the orbiter as both models were pitched through an angle of attack range of -5 deg to 20 deg. Incidence angles between orbiter and tank of 0 deg, 5 deg, 10 deg and 15 deg were investigated. During these tests Mach number was set at 0.6, 2.0 and 4.0.

Fossler, I. H.↗

Origin and evolution of the Saturn system: Observational consequences

A number of important cosmogonic questions concerning the Saturn system can be addressed with a Saturn-orbiter-dual-probe spacecraft mission. These questions include: The origin of the Saturn system; the source of Saturn's excess luminosity; the mechanism by which the irregular satellites were captured; the influence of Saturn's early luminosity on the composition of its regular satellites; and the origin of the rings. The first two topics can be studied by measurements made from an entry probe into Saturn's atmosphere, while the remaining issues can be investigated by measurements conducted from an orbiter. Background information is provided on these five questions describing the critical experiments needed to help resolve them.

Pollack, J. B.↗

System life and reliability modeling for helicopter transmissions

A computer program which simulates life and reliability of helicopter transmissions is presented. The helicopter transmissions may be composed of spiral bevel gear units and planetary gear units - alone, in series or in parallel. The spiral bevel gear units may have either single or dual input pinions, which are identical. The planetary gear units may be stepped or unstepped and the number of planet gears carried by the planet arm may be varied. The reliability analysis used in the program is based on the Weibull distribution lives of the transmission components. The computer calculates the system lives and dynamic capacities of the transmission components and the transmission. The system life is defined as the life of the component or transmission at an output torque at which the probability of survival is 90 percent. The dynamic capacity of a component or transmission is defined as the output torque which can be applied for one million output shaft cycles for a probability of survival of 90 percent. A complete summary of the life and dynamic capacity results is produced by the program.

Savage, M.↗

ETO cloud studies for FIRE 2, part 1

This research program in support of Project FIRE (First ISCCP Regional Experiment) involved two efforts. The results of the first effort, which were in direct support of the Extended Time Observations (ETO) component, are described here. Over the period from June 1990 through May 1991, our remote sensing systems were applied to providing ground-truth cirrus cloud observations for a total of 71 NOAA polar orbiting satellite overpasses. (Chronological tables of this effort are provided.) The primary remote sensor was a dual-polarization ruby (0.694 microns wavelength) lidar, although mid-way through the program we added a number of radiometers to assess the surface radiation budget and cirrus cloud infrared emittance, and some supplemental observations from a Ka-band (8.6 mm) radar were also collected. These studies were conducted from the Facility for Atmospheric Remote Sensing (FARS) at 40 degrees 46 minutes 00 seconds north latitude and 111 degrees 49 minutes 38 seconds east longitude. We also investigated the unusual characteristics of a subset of ETO case studies involving cirrus that generated solar and lunar corona displays. As we reported recently (reprint attached), these cirrus were atypically high and cold in relation to our total midlatitude cloud sample, and were comprised of unexpectedly small ice crystals from 10 to 30 microns in dimension. This finding lends some credence to the so-called cirrus small particle radiative anomaly, but only for very cold (less than -60 C) cirrus clouds. In a supplement, we will describe the design and testing of a prototype cirrus cloud polar nephelometer, which we constructed as part of our second research effort, to allow scattering phase functions to be obtained in future in situ cirrus research.

Sassen, Kenneth↗

Highlights of NASA research in telerobotics

This paper provides a brief overview of the NASA program of research in telerobotics. It describes ongoing effort in a number of participating laboratories investigating topics in human-machine interaction, intelligent task planning and execution, dual-arm control of manipulators with redundant degrees-of-freedom, sensing and perception. A brief list of illustrative references is provided.

Weisbin, C. R.↗

Injection seeded, diode pumped regenerative ring Nd:YAG amplifier for spaceborne laser ranging technology development

A small, all solid state, regenerative ring amplifier designed as a prototype for space application is discussed. Novel features include dual side pumping of the Nd:YAG crystal and a triangular ring cavity design which minimizes the number of optical components and losses. The amplifier is relatively small (3 ns round trip time) even though standard optical elements are employed. The ring regeneratively amplifies a 100 ps single pulse by approximately 10(exp 5) at a repetition rate of 10 to 100 Hz. The amplifier is designed to be injection seeded with a pulsed, 100 ps laser diode at 1.06 microns, but another Nd:YAG laser system supplying higher pulse energies was employed for laboratory experiment. This system is a prototype laser oscillator for the Geoscience Laser Ranging System (GLRS) platform. Results on measurements of beam quality, astigmatism, and gain are given.

Coyle, D. Barry↗

Phase 2: HGM air flow tests in support of HEX vane investigation

Following the start of SSME certification testing for the Pratt and Whitney Alternate Turbopump Development (ATD) High Pressure Oxidizer Turbopump (HPOTP), cracking of the leading edge of the inner HEX vane was experienced. The HEX vane, at the inlet of the oxidizer bowl in the Hot Gas Manifold (HGM), accepts the HPOTP turbine discharge flow and turns it toward the Gaseous Oxidizer Heat Exchanger (GOX HEX) coil. The cracking consistently initiated over a specific circumferential region of the hex vane, with other circumferential locations appearing with increased run time. Since cracking had not to date been seen with the baseline HPOTP, a fluid-structural interaction involving the ATD HPOTP turbine exit flowfield and the HEX inner vane was suspected. As part of NASA contract NAS8-36801, Pratt and Whitney conducted air flow tests of the ATD HPOTP turbine turnaround duct flowpath in the MSFC Phase 2 HGM air flow model. These tests included HEX vane strain gages and additional fluctuating pressure gages in the turnaround duct and HEX vane flowpath area. Three-dimensional flow probe measurements at two stations downstream of the turbine simulator exit plane were also made. Modifications to the HPOTP turbine simulator investigated the effects on turbine exit flow profile and velocity components, with the objective of reproducing flow conditions calculated for the actual ATD HPOTP hardware. Testing was done at the MSFC SSME Dynamic Fluid Air Flow (Dual-Leg) Facility, at air supply pressures between 50 and 250 psia. Combinations of turbine exit Mach number and pressure level were run to investigate the effect of flow regime. Information presented includes: (1) Descriptions of turbine simulator modifications to produce the desired flow environment; (2) Types and locations for instrumentation added to the flow model for improved diagnostic capability; (3) Evaluation of the effect of changes to the turbine simulator flowpath on the turbine exit flow environment; and (4) Comparison of the experimental turbine exit flow environment to the environment calculated for the ATD HPOTP.

Cox, G. B., Jr.↗

Current methods and advances in bone densitometry

Bone mass is the primary, although not the only, determinant of fracture. Over the past few years a number of noninvasive techniques have been developed to more sensitively quantitate bone mass. These include single and dual photon absorptiometry (SPA and DPA), single and dual X-ray absorptiometry (SXA and DXA) and quantitative computed tomography (QCT). While differing in anatomic sites measured and in their estimates of precision, accuracy, and fracture discrimination, all of these methods provide clinically useful measurements of skeletal status. It is the intent of this review to discuss the pros and cons of these techniques and to present the new applications of ultrasound (US) and magnetic resonance (MRI) in the detection and management of osteoporosis.

Review, Academic↗

Searching for the Highest- z Dual Active Galactic Nuclei in the Deepest Chandra Surveys

We present an analysis searching for dual active galactic nuclei (AGN) among 62 high-redshift (2.5 < z < 3.5) X-ray sources selected from the X-UDS, AEGIS-XD, CDF-S, and COSMOS-Legacy Chandra surveys. We aim to quantify the frequency of dual AGN in the high-redshift Universe, which holds implications for black hole merger timescales and low-frequency gravitational wave detection rates. We analyze each X-ray source using BAYMAX, an analysis tool that calculates the Bayes factor for whether a given archival Chandra AGN is more likely a single or dual point source. We find no strong evidence for dual AGN in any individual source in our sample. We increase our sensitivity to search for dual AGN across the sample by comparing our measured distribution of Bayes factors to that expected from a sample composed entirely of single point sources and find no evidence for dual AGN in the sample distribution. Although our analysis utilizes one of the largest Chandra catalogs of high-z X-ray point sources available to study, the findings remain limited by the modest number of sources observed at the highest spatial resolution with Chandra and the typical count rates of the detected sources. Our nondetection allows us to place an upper limit on the X-ray dual AGN fraction at 2.5 < z < 3.5 of 4.8% at the 95% confidence level. Expanding substantially on these results at X-ray wavelengths will require future surveys spanning larger sky areas and extending to fainter fluxes than has been possible with Chandra. We illustrate the potential of the AXIS mission concept in this regard.

79 ASTRONOMY AND ASTROPHYSICS↗

Thickness and uniformity mapping of thin foils using resistive silicon detectors

Alpha energy loss is a common tool used for measuring target thicknesses. However, these measurements are often made without position information, which either forfeits knowledge of material uniformity and local thickness or requires a prohibitive number of measurements per target to partially recover this information. In consideration of this, a method for measuring position-dependent thicknesses is described in this work; by using the position-sensitivity of the dual-axis duo-lateral (DADL) silicon detector, thicknesses across the entire face of the material can be measured to sub-mm precision with a single measurement. Several examples are presented using a number of targets with varying characteristics, which altogether demonstrate the precision, accuracy, and versatility of this technique.

Foil uniformity↗