Search NASA⌕ Search

SEARCH · Search NASA

Results for “error testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Exploration of the polarization angle variability of the Crab Nebula with POLARBEAR and its application to the search for axionlike particles

The Crab Nebula, also known as Tau A, is a polarized astronomical source at millimeter wavelengths. It has been used as a stable light source for polarization angle calibration in millimeter-wave astronomy. However, it is known that its intensity and polarization vary as a function of time at a variety of wavelengths. Thus, it is of interest to verify the stability of the millimeter-wave polarization. If detected, polarization variability may be used to better understand the dynamics of Tau A, and for understanding the validity of Tau A as a calibrator. One intriguing application of such observation is to use it for the search of axionlike particles (ALPs). Ultralight ALPs couple to photons through a Chern-Simons term, and induce a temporal oscillation in the polarization angle of linearly polarized sources. After assessing a number of systematic errors and testing for internal consistency, we evaluate the variability of the polarization angle of the Crab Nebula using 2015 and 2016 observations with the 150 GHz P instrument. We place a median 95% upper bound of polarization oscillation amplitude A < 0.06 5 ° over the oscillation frequencies from 0.75 year − 1 to 0.66 hour − 1 . Assuming that no sources other than ALP are causing Tau A’s polarization angle variation, that the ALP constitutes all the dark matter, and that the ALP field is a stochastic Gaussian field, this bound translates into a median 95% upper bound of ALP-photon coupling g a γ γ < 2.16 × 10 − 12 GeV − 1 × ( m a / 10 − 21 eV ) in the mass range from 9.9 × 10 − 23 eV to 7.7 × 10 − 19 eV . This demonstrates that this type of analysis using bright polarized sources is as competitive as those using the polarization of cosmic microwave background in constraining ALPs. Published by the American Physical Society 2024

Adachi, Shunsuke (ORCID:0000000204007555)↗

Toward Higher-order Accuracy in Self-gravitating Hydrodynamics

High-order algorithms have emerged in numerical astrophysics as a promising avenue to reduce truncation error (proportional to a power of the linear resolution Δ x ) with only a moderate increase to computational expense. Significant effort has been placed in the development of finite-volume algorithms for (magneto)hydrodynamics; however, state-of-the-art astrophysical simulations tightly couple a plenitude of physics, additionally including gravity, photon transport, cosmic-ray transport, chemistry, and/or diffusion, to name a few. Algorithms frequently operator-split this additional physics (often a first-order error in time) and/or adopt a model wherein their evaluation is limited to second-order accuracy in space. In this work, we present a fourth-order-accurate finite-volume scheme for self-gravitating hydrodynamics on a uniform Cartesian grid. The method supplies source terms for the gravitational acceleration ( ρ g ) and gravitational energy release ( ρ v · g ) associated with fourth-order-accurate solutions to the Poisson equation. Our scheme (1) guarantees the conservation of total linear momentum while (2) decreasing (in proportion to Δ x 4 ) the effects of spurious heating and/or cooling associated with truncation error in the gravity. We demonstrate expected convergence rates for the algorithm by measuring errors in test problems evolving self-gravity modified linear waves and 3D polytropic equilibria. We test robustness of the algorithm by integrating an induced “inside-out” adiabatic collapse. We also discuss a method to smoothly downgrade the solution to second-order spatial accuracy to avoid spurious overshoots near steep density and/or pressure gradients.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydraulic servo system increases accuracy in fatigue testing

Hydraulic servo system increases accuracy in applying fatigue loading to a specimen under test. An error sensing electronic control loop, coupled to the hydraulic proportional closed loop cyclic force generator, provides an accurately controlled peak force to the specimen.

Dixon, G. V.↗

Coded communication link for an advanced manned spacecraft.

An analysis, in terms of key design parameters, is presented of a digital link for bidirectional communication between an advanced manned spacecraft, such as the space shuttle, and a ground terminal by means of a synchronous communication relay satellite. Performance of both ground to manned spacecraft and return links are compared with and without coding. A breadboard terminal for simulating the two-way link is described. Results of error rate tests are discussed.

Gould, L. M.↗

Thrust imbalance of the Space Shuttle solid rocket motors

The Monte Carlo statistical analysis of thrust imbalance is applied to both the Titan IIIC and the Space Shuttle solid rocket motors (SRMs) firing in parallel, and results are compared with those obtained from the Space Shuttle program. The test results are examined in three phases: (1) pairs of SRMs selected from static tests of the four developmental motors (DMs 1 through 4); (2) pairs of SRMs selected from static tests of the three quality assurance motors (QMs 1 through 3); (3) SRMs on the first flight test vehicle (STS-1A and STS-1B). The simplified internal ballistic model utilized for computing thrust from head-end pressure measurements on flight tests is shown to agree closely with measured thrust data. Inaccuracies in thrust imbalance evaluation are explained by possible flight test instrumentation errors.

Foster, W. A., Jr.↗

Test progress on the electrostatic membrane reflector

NASA is currently developing a low mass antenna which derives its reflector surface quality from the application of electrostatic forces to form a thin membrane into the desired concave reflector surface. The shuttle-deployed antenna would have a diameter of 100 m and an RMS surface smoothness of 10 to 1 mm for operation at 1 to 10 GHz. Surface quality measurements have been made on a highly deformable elastic membrane, pressurized by electrostatic forces. Included are the effects of the perimeter boundary, splicing of the membrane, the long-scale smoothness of commercial membranes, and the spatial controllability of the membrane using voltage adjustments to alter the electrostatic forces. The electrostatic membrane was found to operate well in an open-loop sense, showing a high degree of position stability and negligible power consumption in dry air. Visco-electric creep was not evident, but the polymer membrane did expand and contract considerably due to its hygroscopic expansion coefficient. A residual roughness of about 0.75 mm existed with the polymer used in these tests; this error is attributed to seams and membrane anisotropy where the material is stiffer in one direction.

Goslee, J. W.↗

Utilization of normal mode initial conditions for detecting errors in the dynamics part of primitive equation global models

When a global atmospheric basic state has constant angular velocity and its temperature varies with altitude only, there exist normal mode solutions to the linearized global primitive equations. The use of these normal modes, which have known behavior in time, is superior to the use of the Rossby-Haurwitz wave as initial conditions for detecting errors in the dynamics part of primitive equation global models. With these initial conditions, integration through only one time step is sufficient to detect many formulation and coding errors. Other tests are still required for detecting problems of nonlinear instability and conservation of integral properties, however.

Chao, W. C.↗

Development of a new, completely implantable intraventricular pressure meter and preliminary report of its clinical experience

A completely implantable intracranial pressure sensor designed for long-term measurement of intraventricular pressure in hydrocephalic patients is described. The measurement principal of the device is discussed along with the electronic and component structure and sources of instrument error. Clinical tests of this implanted pressure device involving both humans and animals showed it to be comparable to other methods of intracranial pressure measurement.

Osaka, K.↗

A comparison of geodetic Doppler satellite receivers

A great number of geodetic Doppler satellite receivers of various types have been employed since early 1970s. In October and November 1979, a comparison was conducted of three more recent types of receivers, including the CMA-751, the JMR-1A, and the MX-1502. A description of the studies involved in conducting the comparison is presented, taking into account the preliminary results obtained on the basis of the processing of the collected data. Attention is given to tracking statistics, chord difference results, range rate measurement errors, residual tests, station position repeatability, and absolute differences to ground control. Recommendations for future comparisons are also provided.

Archinal, B.↗

Metric analysis and data validation across FORTRAN projects

The desire to predict the effort in developing or explaining the quality of software has led to the proposal of several metrics. As a step toward validating these metrics, the Software Engineering Laboratory (SEL) has analyzed the software science metrics, cyclomatic complexity, and various standard program measures for their relation to effort (including design through acceptance testing), development errors (both discrete and weighted according to the amount of time to locate and fix), and one another. The data investigated are collected from a project FORTRAN environment and examined across several projects at once, within individual projects and by reporting accuracy checks demonstrating the need to validate a database. When the data comes from individual programmers or certain validated projects, the metrics' correlations with actual effort seem to be strongest. For modules developed entirely by individual programmers, the validity ratios induce a statistically significant ordering of several of the metrics' correlations. When comparing the strongest correlations, neither software science's E metric cyclomatic complexity not source lines of code appears to relate convincingly better with effort than the others.

Basili, Victor R.↗

Rocketdyne automated dynamics data analysis and management system

An automated dynamics data analysis and management systems implemented on a DEC VAX minicomputer cluster is described. Multichannel acquisition, Fast Fourier Transformation analysis, and an online database have significantly improved the analysis of wideband transducer responses from Space Shuttle Main Engine testing. Leakage error correction to recover sinusoid amplitudes and correct for frequency slewing is described. The phase errors caused by FM recorder/playback head misalignment are automatically measured and used to correct the data. Data compression methods are described and compared. The system hardware is described. Applications using the data base are introduced, including software for power spectral density, instantaneous time history, amplitude histogram, fatigue analysis, and rotordynamics expert system analysis.

Tarn, Robert B.↗

Analysis of pre-flight modulator voltage calibration data for the Voyager plasma science experiment

The Voyager Plasma Science (PLS) modulator calibration (MVM) data analysis was undertaken in order to check the correctness of the fast A/D converter formulas that connect low voltage monitor signals (MV) with digital outputs (DN), to determine the proportionality constants between the actual modulator grid potential (V) and the monitor voltage (MV), and to establish an algorithm to link the digitized readouts (DN) with the actual grid potential (V). The analysis results are surprising in that the derived conversion constants deviate by fairly significant amounts from their nominal values. However, it must be kept in mind that the test results which were used for analysis may be very imprecise. Even if it is assumed that the test result errors are very large, they do no appear to be capable to account for all discrepancies between the theoretical expectations and the results of the analysis. Measurements with the flight spare instrument appear to be the only means of investigating these effects further.

Nastov, Ognen↗

Adaptive Telemetry Multiplexer

Telemetry-data-acquisition unit adjusted remotely to produce changes in sampling rate, sampling channels, measurement scale, and output-bias level. Functional configuration adapted to changing conditions or new requirements by distant operator over telemetry link. Reconfiguration done in real time, without removing equipment from service. Bus-interface unit accepts reprogramming commands and translates them for low-rate adaptive multiplexer. Reprogrammable equipment reduces need for spare parts, since not necessary to stock variety of hardware with fixed characteristics. Adaptive multiplexer performs well in tests, amplitude errors less than 0.5 percent, distortion less than 0.25 percent, and crosstalk and common-mode rejection indiscernible.

Sinderson, R. L.↗

Removing cosmic-ray hits from multiorbit HST Wide Field Camera images

We present an optimized algorithm that removes cosmic rays ('CRs') from multiorbit Hubble Space Telescope (HST) Wide Field/Planetary Camera ('WF/PC') images. It computes the image noise in every iteration from the WF/PC CCD equation. This includes all known sources of random and systematic calibration errors. We test this algorithm on WF/PC stacks of 2-12 orbits as a function of the number of available orbits and the formal Poissonian sigma-clipping level. We find that the algorithm needs greater than or equal 4 WF/PC exposures to locate the minimal sky signal (which is noticeably affected by CRs), with an optimal clipping level at 2-2.5 x sigma(sub Poisson). We analyze the CR flux detected on multiorbit 'CR stacks,' which are constructed by subtracting the best CR filtered images from the unfiltered 8-12 orbit average. We use an automated object finder to determine the surface density of CRS as a function of the apparent magnitude (or ADU flux) they would have generated in the images had they not been removed. The power law slope of the CR 'counts' (gamma approximately = 0.6 for N(m) m(exp gamma)) is steeper than that of the faint galaxy counts down to V approximately = 28 mag. The CR counts show a drop off between 28 less than or approximately V less than or approximately 30 mag (the latter is our formal 2 sigma point source sensitivity without spherical aberration). This prevents the CR sky integral from diverging, and is likely due to a real cutoff in the CR energy distribution below approximately 11 ADU per orbit. The integral CR surface density is less than or approximately 10(exp 8)/sq. deg, and their sky signal is V approximately = 25.5-27.0 mag/sq. arcsec, or 3%-13% of our NEP sky background (V = 23.3 mag/sq. arcsec), and well above the EBL integral of the deepest galaxy counts (B(sub J) approximately = 28.0 mag/sq. arcsec). We conclude that faint CRs will always contribute to the sky signal in the deepest WF/PC images. Since WFPC2 has approximately 2.7x lower read noise and a thicker CCD, this will result in more CR detections than in WF/PC, potentially affecting approximately 10%-20% of the pixels in multiorbit WFPC2 data cubes.

Windhorst, Rogier A.↗

A two dimensional interface element for coupling of independently modeled three dimensional finite element meshes and extensions to dynamic and non-linear regimes

The work reported here pertains only to the first year of research for a three year proposal period. As a prelude to this two dimensional interface element, the one dimensional element was tested and errors were discovered in the code for built-up structures and curved interfaces. These errors were corrected and the benchmark Boeing composite crown panel was analyzed successfully. A study of various splines led to the conclusion that cubic B-splines best suit this interface element application. A least squares approach combined with cubic B-splines was constructed to make a smooth function from the noisy data obtained with random error in the coordinate data points of the Boeing crown panel analysis. Preliminary investigations for the formulation of discontinuous 2-D shell and 3-D solid elements were conducted.

Aminpour, Mohammad↗

On the Possibility of Ill-Conditioned Covariance Matrices in the First-Order Two-Step Estimator

The first-order two-step nonlinear estimator, when applied to a problem of orbital navigation, is found to occasionally produce first step covariance matrices with very low eigenvalues at certain trajectory points. This anomaly is the result of the linear approximation to the first step covariance propagation. The study of this anomaly begins with expressing the propagation of the first and second step covariance matrices in terms of a single matrix. This matrix is shown to have a rank equal to the difference between the number of first step states and the number of second step states. Furthermore, under some simplifying assumptions, it is found that the basis of the column space of this matrix remains fixed once the filter has removed the large initial state error. A test matrix containing the basis of this column space and the partial derivative matrix relating first and second step states is derived. This square test matrix, which has dimensions equal to the number of first step states, numerically drops rank at the same locations that the first step covariance does. It is formulated in terms of a set of constant vectors (the basis) and a matrix which can be computed from a reference trajectory (the partial derivative matrix). A simple example problem involving dynamics which are described by two states and a range measurement illustrate the cause of this anomaly and the application of the aforementioned numerical test in more detail.

Garrison, James L.↗