Search NASA⌕ Search

SEARCH · Search NASA

Results for “focused ion beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Electrostatic Waves and Electron Holes in Simulations of Low-Mach Quasi-Perpendicular Shocks

Collisionless low Mach number shocks are abundant in astrophysical and space plasma environments, exhibiting complex wave activity and wave-particle interactions. In this paper, we present 2D Particle in-Cell (PIC) simulations of quasi-perpendicular nonrelativistic (vsh ≈ (5500−22000) km/s) low Mach number shocks, with a specific focus on studying electrostatic waves in the shock ramp and the precursor regions. In these shocks, an ion-scale oblique whistler wave creates a configuration with two hot counter streaming electron beams, which drive unstable electron acoustic waves (EAWs) that can turn into electrostatic solitary waves (ESWs) at the late stage of their evolution. By conducting simulations with periodic boundaries, we show that EAW properties agree with linear dispersion analysis. The characteristics of ESWs in shock simulations, including their wavelength and amplitude, depend on the shock velocity. When extrapolated to shocks with realistic velocities (vsh ≈ 300 km/s), the ESW wavelength is reduced to one tenth of the electron skin depth and the ESW amplitude is anticipated to surpass that of the quasi-static electric field by more than a factor of 100. These theoretical predictions may explain a discrepancy, between PIC and satellite measurements, in the relative amplitude of high and low-frequency electric field fluctuations.

Plasma astrophysics↗

In-SITU, Time-resolved Raman Spectro-micro-topography of an Operating Lithium Ion Battery

A Raman microscope has been coupled to a computer-controlled, two-dimensional linear translator attached to a custom-designed, sealed optical chamber to allow in situ acquisition of space-, and time-resolved spectra of an operating thin graphite/LiCoO2 Li-ion battery. This unique arrangement made it possible to collect continuously series of Raman spectra from a sharply defined edge of the battery exposing the anode (A), separator (S), and cathode (C), during charge and discharge, while the device was moved back and forth under the fixed focused laser beam along an axis normal to the layered A/S/C plane. Clear spectral evidence was obtained for changes in the amount of Li(+) within particles of graphite in the anode, and, to a lesser extent, of LiCoO2 in the cathode, during battery discharge both as a function of position and time. Analysis of time-resolved Raman spectro-micro-topography (SMT) measurements of the type described in this work are expected to open new prospects for assessing the validity of theoretical models aimed at simulating the flow of Li(+) within Li-ion batteries under operating conditions.

Luo, Yu↗

Diagnosis of NMOS DRAM functional performance as affected by a picosecond dye laser

A picosec pulsed dye laser beam was at selected wavelengths successfully used to simulate heavy-ion single-event effects (SEEs) in negative channel NMOS DRAMs. A DRAM was used to develop the test technique because bit-mapping capability and previous heavy-ion upset data were available. The present analysis is the first to establish such a correlation between laser and heavy-ion data for devices, such as the NMOS DRAM, where charge collection is dominated by long-range diffusion, which is controlled by carrier density at remote distances from a depletion region. In the latter case, penetration depth is an important parameter and is included in the present analysis. A single-pulse picosecond dye laser beam (1.5 microns diameter) focused onto a single cell component can upset a single memory cell; clusters of memory cell upsets (multiple errors) were observed when the laser energy was increased above the threshold energy. The multiple errors were analyzed as a function of the bias voltage and total energy of a single pulse. A diffusion model to distinguish the multiple upsets from the laser-induced charge agreed well with previously reported heavy ion data.

Kim, Q.↗

Stigmatically focusing partial pressure analyzer with dual chamber ion source

The partial pressure analyzer developed has a high absolute sensitivity and high resolution. Interaction effects, as they occur in conventional partial pressure analyzers between the heating filament for the emission of electrons and the residual gas, are suppressed by removing the heating filament from the measurement area. The electron beam is generated in an auxiliary vacuum compartment, and passes subsequently through an aperture into the ionization compartment. The probability is small, therefore, that the presence of substances produced at the heating filament by chemical reactions and thermal decompositions will have disturbing effects. The high sensitivity and resolution of the instrument are obtained with the aid of an electron path configuration of unconventional characteristics.

Rasskopf, Klaus F.↗

The theory of ionospheric focused heating

Ionospheric modification by high power radio waves and by chemical releases are combined in a theoretical study of ionospheric focused heating. The release of materials which promote electron-ion recombination creates a hole in the bottomside ionosphere. The ionospheric hole focuses high power radio waves from a ground-based transmitter to give a 20 dB or greater enhancement in power density. The intense radio beam excites atomic oxygen by collisions with accelerated electrons. Airglow from the excited oxygen provides a visible trace of the focused beam. The large increase in the intensity of the radio beam stimulates new wave-plasma interactions. Numerical simulations show that the threshold for the two-plasmon decay instability is exceeded. The interaction of the pump electromagnetic wave with the backward plasmon produces a scattered electromagnetic wave at 3/2 the pump frequency. The scattered wave provides a unique signature of the two-plasmon decay process for ground-based detection.

Bernhardt, P. A.↗

Reversal electron attachment ionizer for detection of trace species

An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of the electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

Bernius, Mark T.↗

New measurements for hadrontherapy and space radiation: biology

The dual goals of optimizing clinical efficacy of hadrontherapy and determining radiation risk estimates for space research have intersected to a common focus for investigation of the biological effects of charged particles. This paper briefly highlights recent international progress at accelerator facilities engaged in both biological and clinical studies of the effects of particle beams, primarily protons, carbon and iron ions. Basic mechanisms of molecular, cellular and tissue responses continue under investigation for radiations with a range of ionization densities. Late normal tissue effects, including the risk of cancer in particular, are of importance for both research fields. International cooperation has enhanced the rate of progress as evidenced by recent publications. Specific areas of biomedical research related to the biological radiotoxicity of critical organs (especially the central nervous system), individual radiosensitivities to radiation carcinogenesis, and the analysis of effects in mixed radiation fields still require more research. Recommendations for addressing these issues are made.

Review↗

Reversal electron attachment ionizer for detection of trace species

An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of said electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

Bernius, Mark T.↗

Charge Deposition/Neutralization and Dust Removal via Plasma Interactions

Electrically charged and chemically reactive lunar dust can cause serious problems to spacecraft, surface equipment, and astronaut health, so understanding its interaction with and transport through the lunar plasma environment is important to dust mitigation efforts. We explore the charging of granular material in the natural environment of the Moon, recreate those conditions in the laboratory under high vacuum, and examine dust transport and charge neutralization for application in future lunar missions. Phenomena such as charge deposition via electron and ion beams, photoionization through ultraviolet light exposure, neutralization of charge through impingement by an ionized compressed gas, and tribocharging during dust liberation from surfaces will be presented. Surface materials of interest such as floating/grounded conductors and orthofabric for spacesuits are the preliminary focus of this effort. An electrometer is used to characterize currents interacting with the surfaces in the case of the electron/ion/UV source exposure, an electrostatic voltmeter is used to measure the potential on the surfaces without inadvertently discharging them, and a charge plate monitor is used to verify the efficiency of discharging the surfaces via ionized gas impingement. After setup of the initial charge conditions on the surfaces, a quick burst of high-pressure gas is used to overcome adhesion forces and initially dislodge the dust from the surfaces, followed by a low flow of gas that is ionized via application of a strong electric field. The gas is released in a high vacuum environment so as the pressure drops from the initial compressed state through to the vacuum state, the mean free path reaches a point where ionization can occur before all the gas disperses into the vacuum. This ionized gas can then neutralize both the dust and the surface to ensure minimal resettling. Several parameters such as gas composition, electrode geometry, high voltage waveform shape/polarity, and pulse timing have been explored and will be presented here.

electrostatics↗

Unified Models of Turbulence and Nonlinear Wave Evolution in the Extended Solar Corona and Solar Wind

The PI (Cranmer) and Co-I (A. van Ballegooijen) made significant progress toward the goal of building a "unified model" of the dominant physical processes responsible for the acceleration of the solar wind. The approach outlined in the original proposal comprised two complementary pieces: (1) to further investigate individual physical processes under realistic coronal and solar wind conditions, and (2) to extract the dominant physical effects from simulations and apply them to a one-dimensional and time-independent model of plasma heating and acceleration. The accomplishments in the report period are thus divided into these two categories: 1a. Focused Study of Kinetic MHD Turbulence. We have developed a model of magnetohydrodynamic (MHD) turbulence in the extended solar corona that contains the effects of collisionless dissipation and anisotropic particle heating. A turbulent cascade is one possible way of generating small-scale fluctuations (easy to dissipate/heat) from a pre-existing population of low-frequency Alfven waves (difficult to dissipate/heat). We modeled the cascade as a combination of advection and diffusion in wavenumber space. The dominant spectral transfer occurs in the direction perpendicular to the background magnetic field. As expected from earlier models, this leads to a highly anisotropic fluctuation spectrum with a rapidly decaying tail in the parallel wavenumber direction. The wave power that decays to high enough frequencies to become ion cyclotron resonant depends on the relative strengths of advection and diffusion in the cascade. For the most realistic values of these parameters, though, there is insufficient power to heat protons and heavy ions. The dominant oblique waves undergo Landau damping, which implies strong parallel electron heating. We thus investigated the nonlinear evolution of the electron velocity distributions (VDFs) into parallel beams and discrete phase-space holes (similar to those seen in the terrestrial magnetosphere) which are an alternate means of heating protons via stochastic interactions similar to particle-particle collisions. 1b. Focused Study of the Multi-Mode Detailed Balance Formalism. The PI began to explore the feasibility of using the "weak turbulence," or detailed-balance theory of Tsytovich, Melrose, and others to encompass the relevant physics of the solar wind. This study did not go far, however, because if the "strong" MHD turbulence discussed above is a dominant player in the wind's acceleration region, this formalism is inherently not applicable to the corona. We will continue to study the various published approaches to the weak turbulence formalism, especially with an eye on ways to parameterize nonlinear wave reflection rates. 2. Building the Unified Model Code Architecture. We have begun developing the computational model of a time-steady open flux tube in the extended corona. The model will be "unified" in the sense that it will include (simultaneously for the first time) as many of the various proposed physical processes as possible, all on equal footing. To retain this generality, we have formulated the problem in two interconnected parts: a completely kinetic model for the particles, using the Monte Carlo approach, and a finite-difference approach for the self-consistent fluctuation spectra. The two codes are run sequentially and iteratively until complete consistency is achieved. The current version of the Monte Carlo code incorporates gravity, the zero-current electric field, magnetic mirroring, and collisions. The fluctuation code incorporates WKJ3 wave action conservation and the cascade/dissipation processes discussed above. The codes are being run for various test problems with known solutions. Planned additions to the codes include prescriptions for nonlinear wave steepening, kinetic velocity-space diffusion, and multi-mode coupling (including reflection and refraction).

Cranmer, Steven R.↗

Electron acceleration at nearly perpendicular collisionless shocks. 3: Downstream distributions

Spacecraft observations at the Earth's bow shock and at interplanetary shocks have established that the largest fluxes of accelerated suprathermal electrons occur in so-called shock spike events immediately downstream of the shock ramp. Previous theoretical efforts have mainly focused on explaining upstream energetic electron beams. Here we investigate the general motion and acceleration of energetic electrons in a curved, nearly perpendicular shock by numerically integrating the orbits of solar wind halo electrons in shock fields generated by a hybrid simulation (core electron fluid and kinetic ions). Close to the angle Theta(sub Bn) = 90 degs between the upstream magnetic field and shock normal, the calculations result in a (perpendicular) temperature increase proportional to the magnetic field ratio and give the highest phase space densities in the overshoot. For a steep distribution, the temperature change can correspond to an enhancement of the distribution by several orders of magnitude. These results are in agreement with predictions from adiabatic mapping. With smaller angles Theta(sub Bn), the overshoot and downstream densities fall off quickly, because the adiabatic energy gain is less and fewer electrons transmit. The shock curvature also leads to an accumulation of electrons close to 90 degs. Without pitch angle scattering, energization is only significant within a few (approximately 5 to 10 degs) degrees of the point of tangency. However, shock spike events appear to be observed more easily and farther away from 90 degs. Given that over a region of several degrees around 90 degs the theory gives enhancements of up to approximately 4 orders of magnitude, such electrons could in principle account for the typically observed enhancements of 1 to 2 orders of magnitude, if they were distributed over Theta(sub Bn). To test the idea that scattering could efficiently redistribute the energetic electrons, we have conducted test particle simulations in which artificial pitch angle scattering is included. We find that such a process can indeed be very efficient and can explain observations of shock spike events far away from Theta(sub Bn) is approximately 90 degs. The scattering naturally leads to much higher phase space densities at smaller Theta(sub Bn) than what a local one-dimensional mapping would predict and thus can account for an observed discrepancy with adiabatic theory stated in the literature.

Krauss-Varban, D.↗

Investigation of beam-plasma interactions

Data from the SCATHA satellite was analyzed to solve the problems of establishing electrical contact between a satellite and the ambient plasma. The original focus of the work was the electron gun experiments conducted near the geosynchronous orbit, which resulted in observations which bore a startling similarity to observations of the SEPAC experiments on SPACELAB 1. The study has evolved to include the ion gun experiments on SCATHA, a modest laboratory effort in hollow cathode performance, and preparation for flight experiments pertinent to tether technology. These areas are addressed separately.

Olsen, Richard C.↗

Single Event Transient Analysis of an SOI Operational Amplifier for Use in Low-Temperature Martian Exploration

The next generation of Martian rover#s to be launched by JPL are to examine polar regions where temperatures are extremely low and the absence of an earth-like atmosphere results in high levels of cosmic radiation at ground level. Cosmic rays lead to a plethora of radiation effects including Single Event Transients (SET) which can severely degrade microelectronic functionality. As such, a radiation-hardened, temperature compensated CMOS Single-On-Insulator (SOI) Operational Amplifier has been designed for JPL by the University of Tennessee and fabricated by Honeywell using the SOI V process. SOI technology has been shownto be far less sensitive to transient effects than both bulk and epilayer Si. Broad beam heavy-ion tests at the University of Texas A&M using Kr and Xebeams of energy 25MeV/amu were performed to ascertain the duration and severity of the SET for the op-amp configured for a low and high gain application. However, some ambiguity regarding the location of transient formation required the use of a focused MeV ion microbeam. A 36MeV O6(+) microbeam. the Sandia National Laboratory (SNL) was used to image and verify regions of particular concern. This is a viewgraph presentation

operational amplifier↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axial, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions.

Pearson, J. B.↗

A First Look at Carbon and Oxygen Stable Isotope Measurements of Martian Atmospheric C02 by the Phoenix Lander

Precise stable isotope measurements of the CO2 in the martian atmosphere have the potential to provide important constraints for our understanding of the history of volatiles, the carbon cycle, current atmospheric processes, and the degree of water/rock interaction on Mars. The isotopic composition of the martian atmosphere has been measured using a number of different methods (Table 1), however a precise value (<1%) has yet to be achieved. Given the elevated 13C values measured in carbonates in martian meteorites it has been supposed that the martian atmosphere was enriched in delta(sup 13)C. This was supported by measurements of trapped CO2 gas in EETA 79001[2] which showed elevated delta(sup 13)C values (Table 1). More recently, Earth-based spectroscopic measurements of the martian atmosphere have measured the martian CO2 to be depleted in delta(sup 13)C relative to CO2 in the terrestrial atmosphere. The spectroscopic measurements performed by Krasnopolsky et al. were reported with approx.2% uncertainties which are much smaller than the Viking measurements, but still remain very large in comparison to the magnitude of carbon and oxygen isotope fractionations under martian surface conditions. The Thermal Evolved Gas Analyzer (TEGA) instrument on the Mars Phoenix Lander included a magnetic sector mass spectrometer (EGA) which had the goal of measuring the isotopic composition of martian atmospheric CO2 to within 0.5%. The mass spectrometer is a miniature magnetic sector instrument intended to measure both the martian atmosphere as well as gases evolved from heating martian soils. Ions produced in the ion source are drawn out by a high voltage and focused by a magnetic field onto a set of collector slits. Four specific trajectories are selected to cover the mass ranges, 0.7 - 4, 7 - 35, 14 - 70, and 28 - 140 Da. Using four channels reduces the magnitude of the mass scan and provides simultaneous coverage of the mass ranges. Channel electron multiplier (CEM) detectors that operate in the pulse counting mode detect the ion beams.

Niles, P.B.↗

Geometries and focal properties of two electron-lens systems useful in low-energy electron or ion scattering

Geometries and focal properties are given for two types of electron-lens system commonly needed in electron scattering. One is an electron gun that focuses electrons from a thermionic emitter onto a fixed point (target) over a wide range of final energies. The other is an electron analyzer system that focuses scattered electrons of variable energy onto a fixed position (e.g., the entrance plane of an analyzer) at fixed energy with a zero final beam angle. Analyzer-system focusing properties are given for superelastically, elastically, and inelastically scattered electrons. Computer calculations incorporating recent accurate tube-lens focal properties are used to compute lens voltages, locations and diameters of all pupils and windows, filling factors, and asymptotic rays throughout each lens system. Focus voltages as a function of electron energy and energy change are given, and limits of operation of each system discussed. Both lens systems have been in routine use for several years, and good agreement has been consistently found between calculated and operating lens voltages.

Chutjian, A.↗

The threshold laws for electron-atom and positron-atom impact ionization

The Coulomb-dipole theory is employed to derive a threshold law for the lowest energy needed for the separation of three particles from one another. The study focuses on an electron impinging on a neutral atom, and the dipole is formed between an inner electron and the nucleus. The analytical dependence of the transition matrix element on energy is reduced to lowest order to obtain the threshold law, with the inner electron providing a shield for the nucleus. Experimental results using the LAMPF accelerator to produce a high energy beam of H- ions, which are then exposed to an optical laser beam to detach the negative H- ion, are discussed. The threshold level is found to be confined to the region defined by the upper bound of the inverse square of the Coulomb-dipole region. Difficulties in exact experimental confirmation of the threshold are considered.

Temkin, A.↗