Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid following”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Modeling and Simulation of Power-Electronic Inverters in Analog Electronic Circuit Simulators

This paper demonstrates how equivalent-circuit representations of grid-following power-electronic inverters can be realized within a SPICE-based development environment using common circuit components and VerilogA code. This facilitates computationally lean simulations of inverter networks leveraging the strengths of SPICE in large-scale simulations. We validate the approach with time-domain simulations for a modified version of the IEEE standard 118-bus system modeled in Virtuoso (a SPICE-based solver). Simulation results are compared-focusing on accuracy and computation speed-with results from a commonly used power-electronics simulation package. We note a significant decrease in simulation time with comparable signal resolution when simulating the network in SPICE.

Billmeyer, Ryan↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Safe Deep Reinforcement Learning for Robust Frequency and Voltage-Constrained Networked Microgrid Restoration

Here, this paper proposes a safe soft actor-critic reinforcement learning (RL) algorithm–based controller for networked microgrid restoration. It formulates the post black-start start as a finite-horizon constrained Markov decision process. The RL agent co-optimizes real and reactive power set-points for both grid-forming and grid-following inverters under explicit voltage and frequency constraints, while enforcing proper power sharing via the Mean Active Power Sharing Index (MPSI) and Mean Reactive Power Sharing Index (MQSI). Numerical results obtained on the IEEE 123-bus distribution system show that the proposed method achieves a mean voltage build-up time of 0.01 s without breaching the 5% sharing-violation budget under various load scenarios, considering MPSI and MQSI indices. These findings demonstrate that the proposed method yields fast and safe black-start schedules without resorting to heuristic penalties.

Selim, Alaa [Dartmouth College, Hanover, NH (Unite↗

Analog In-Memory Computing for the Synthetic Aperture Radar Polar Format Algorithm

As the utility of synthetic aperture radar (SAR) systems increases in autonomous vehicles, satellites, and other power- and space-constrained edge applications, there is a growing need for processors that can form SAR images at low power. In recent years, analog in-memory compute (AIMC) has shown immense promise for accelerating neural networks and other matrix-vector multiplication (MVM) heavy workloads at the edge. Here, in this work, we examine how the polar format algorithm (PFA), a popular SAR image formation algorithm, can be mapped to these AIMC systems. The PFA maps readily onto analog MVMs because it primarily consists of two linear operations: interpolation of frequency-domain data to a Cartesian grid, followed by a 2-D Fourier transform. This work presents two approaches to map the interpolation operation onto MVMs in analog hardware: a chirp transform and a modified form of sinc interpolation. These mappings introduce algorithmic errors, and their effect on the quality of SAR image formation is examined, both quantitatively and qualitatively. In addition, the impact of errors introduced by the analog hardware is explored to determine which approach is optimal under varying assumptions about the underlying analog memory devices and circuits.

Analog computing↗

Enabling Extended-Term Simulation of Power Systems with High PV Penetration. Final Report

This is the final Technical Report for DOE-SETO Project Award # DE-EE0036461. The goal of this project is to advance the understanding of the grid impact of high penetration of photovoltaic (PV) generation by developing novel numerical methods to solve the differential algebraic equations (DAEs) that define power systems. This will overcome the limitations of current software packages – namely that they only consider fast dynamics over brief time periods. The work presented in this final project report covers results over the entire period of the project. This includes results on model development, code development for the PST repository, datasets in the PST repository, algorithm development and results from variable time-step simulations, development and results from multirate simulations, and sensitivity analysis of key parameter in variable time-step methods. In addition, this report discusses project outreach activities to stakeholders, and a summary of project products. Also covered in this final report is the writing of two conference papers (one of which has already been accepted) and a journal paper. In addition, the updating of two inverter models (both grid forming and grid following) to be compatible with the latest version of PST software is discussed.

14 SOLAR ENERGY↗

How a Large-Scale Deployment of Grid-Forming Inverters May Impact Inter-Area Oscillation Modes: An Investigation in the US Western Interconnection

This report describes work performed to evaluate the impact of high grid-forming (GFM) inverter penetration on the inter-area oscillation mode characteristics of the Western Interconnection. Using simulations, this work analyzes how: a) replacing fossil-fuel-based synchronous generators by GFM inverters will impact properties of the North-South mode, and b) replacing the Colstrip power plant by grid-following (GFL) and GFM inverters will change the characteristics of the Montana mode. Results obtained indicate that high penetration of GFM inverters will significantly alter inter-area oscillation characteristics in interconnections. Low frequency oscillations in the 0.11 Hz range will be predominantly driven by remaining synchronous machines, and hence their relative distribution in the interconnection will impact mode characteristics and observability.

20 FOSSIL-FUELED POWER PLANTS↗

Impact of Inverter-Based Resources on Grid Protection: A Review of Negative-Sequence Current Generation

The increasing integration of inverter-based resources (IBRs) in power grids poses challenges to traditional protection systems, primarily due to their different fault current signatures compared to conventional synchronous generators. Unlike synchronous generators whose fault response is dictated by their physical design, IBRs exhibit a wide range of fault characteristics due to manufacturer-specific control algorithms and settings. This dependence on proprietary control schemes makes modeling IBR behavior during faults significantly more complex, especially considering the rapid evolution of inverter technology and the diverse control strategies employed. While much research has focused on the positive-sequence current injections of IBRs during symmetrical faults, the understanding of negative-sequence current generation during non-symmetrical faults remains limited. This report provides an overview of current research on IBRs' negative-sequence current generation during unbalanced faults and its impact on protection schemes based on negative-sequence components. It covers both type III wind turbines and full-size converter-based IBRs. Additionally, this report reviews strategies for grid-forming controlled inverters to generate negative-sequence current during unbalanced faults, in addition to grid-following controlled ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Analysis of an Internal Combustion Engine (ICE) - Solid Oxide Fuel Cell (SOFC) Hybrid Cycle

The variability of renewable energy sources poses challenges for reliable grid operation. Conventional thermal power sources, though reliable, often lack operational flexibility. Hybrid energy systems that integrate Solid Oxide Fuel cells (SOFC) with Internal Combustion Engines (ICE) offer a promising solution by achieving relatively higher efficiency and grid-following capability. This study investigates performance of a 100-kW pressurized SOFC-ICE hybrid cycle. In this configuration, unutilized SOFC fuel is used to drive the engine, with a turbocharger providing air supply and an external reformer generating syngas. System components were numerically modeled using MATLAB/SIMULINK for the SOFC and reformer, and EBSILON® for the ICE and balance of plant. Parametric studies varied fuel utilization (70-90%), reformer temperature (600 – 1000K), anode off-gas recirculation (0 – 70%), and current density (0.2 – 0.55 A/cm2). Results show that the SOFC and ICE operate as thermally independent topping and bottoming cycles, achieving peak efficiency of 62% under optimized conditions.

hybrid↗

Controller Requirements for Managing Community Microgrids

Microgrid control systems are central to the functioning of a microgrid. They are responsible for managing distributed energy resources (DER) in both grid-connected and islanded modes of operation. Although microgrids are being developed and deployed by many utilities, several questions are being raised about the control system that manages them. This document provides the detailed list of requirements for a feeder-level microgrid controller to manage various islanded and grid-connected use cases. Functionally, the use cases include control scenarios that require the controller to maintain energy balance, prevent constraint violations, manage switching equipment, manage grid-forming (GFM) and grid-following (GFL) DER, manage critical/non-critical loads, and coordinate with peer systems to operate joined island areas. In addition to detailed requirements, the document includes interface and performance metrics for functional evaluation. These requirements can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; requirements also apply to third-party managed microgrid controllers that coordinate with the utility- and customer-owned equipment. The document can also be used by technology developers and project developers in industry to specify desired control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Parametric Reduced-Order Model for Inverter Short-Circuit Response in Protection Studies

This paper presents a reduced-order model (ROM) for grid-following (GFL) inverters that reproduces inverter fault current trajectories, including sub transients, transient, and steady-state phases, across a range of fault types, locations, and pre-fault operating points. . The proposed model is developed by: Constructing the positive- and negative-sequence current with parameterization fitted by large data training and fitting Validating using EMT simulation against EMT full model and demonstrating the ROM's capability to capture fault current magnitude, phase angle, and oscillatory transients. Building a standard EMT simulation platform library component for easy configuration and application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Hierarchical Data-Driven Protection for Microgrid with 100% Renewable Penetration: Preprint

The accurate detection and isolation of faults is critical for the reliable operation of microgrids (MGs). Traditional protection approaches are even more challenged for 100% renewable MGs because inverter-based resources (IBRs) are the only sources for fault current which are usually low and unpredictable/non-uniform. This calls for new protection scheme that can identify IBR fault responses and detect faults in MGs. Data-driven based protection can learn the pattern of IBR fault responses and make the correct decision to identify faults. Therefore, this paper presents a data-driven approach for fault localization in island MGs. The approach builds a training dataset of comprehensive fault scenarios that can be used to learn fault characteristics from processed measurements. The localization task is modeled as a binary classification problem at each relay, which simplifies the learning process. Then, a hierarchical decision mechanism is used to identify the fault location. The proposed approach is assessed using an exemplary MG with several grid-forming (GFM) and grid-following (GFL) inverters, where accurate estimation of fault location is achieved. The data-driven based protection approach developed in this paper provides a generic framework and useful guidance for power system protection engineers to achieve reliable protection for MGs with 100% renewables.

artificial intelligence↗

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation: Preprint

Photovoltaic inverter (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. Due to this proprietary nature, it is not possible to share EMT domain models for system studies. This research work presents a novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to enhance the PV inverter modeling. We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests including voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data was used in learning-based model training. This learning-based model was imported into an Electromagnetic Transient (EMT) simulation tool using co-simulation techniques to complete the modeling effort and integrate the model into an EMT simulation tool. The three key components in this research work are the design of experimental setup, use of learning-based approach for model development and use of co-simulation to complete the approach. The proposed approach will allow users to develop a model in a really short period of time and achieve reasonable inverter models.

artificial intelligence↗