Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Proposal to National Aeronautics and Space Administration for continuation of a grazing incidence imaging telescope for X-ray astronomy using sounding rockets

The construction of a high resolution imaging telescope experiment payload suitable for launch on an Astrobee F sounding rocket was proposed. Also integration, launch, and subsequent data analysis effort were included. The payload utilizes major component subassemblies from the HEAO-B satellite program which were nonflight development units for that program. These were the X ray mirror and high resolution imager brassboard detector. The properties of the mirror and detector were discussed. The availability of these items for a sounding rocket experiment were explored with the HEAO-B project office.

Murray, B.↗

Space Telescope Digicon

The Digicon, chosen by NASA as the detector for the High Resolution Spectrograph (HRS) and the Faint Object Spectrograph (FOS) is a 512 parallel output channel vacuum photodetector. There are two HRS Digicons with spectral sensitivity ranges from 1050 A to 1800 A and 1150 A to 3000 A respectively, and two FOS Digicons, which have spectral ranges extending to 7000 A. The significant requirements for these devices are 0.01 counts per second background count rate per diode, state-of-the-art Digicon pulse height resolution (typical 15%) and a high degree of imaging precision and stability. The results of a manufacturing and test program to develop the Digicons coupled with extensive prior work has shown that these requirements can be met. The Digicon because of its inherent ruggedness is particularly well suited to space applications.

Alting-Mees, H. R.↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗

Upstream particles observed in the earth's foreshock region

The characteristics and interrelationships of upstream suprathermal particles and plasma waves observed in the earth's foreshock region are examined on the basis of data from eight instruments, including the University of Iowa Lepedeas, and plasma wave instruments, the Berkeley high time resolution particle detectors, and the UCLA magnetometer on ISEE 1 and 2. It is found that suprathermal ions in the foreshock region travel along the magnetic field away from the bow shock. It is also found that ions observed in the foreshock region display gyrophase organization produced by ion clusters with a spatial scale of less than 1 Rg, and that dispersed ion distributions are produced primarily by direct sources at or near the bow shock.

Eastman, T. E.↗

Gamma-ray and optical observations of the 1979 November 8 solar flare

The solar flare on 1979 November 8 11h 21m 28s UT was observed by the Tel Aviv telescope of the Big Bear Solar Observatory and the High Resolution Gamma-Ray Spectrometer on the High Energy Astronomy Observatory HEAO 3. Photographs in alpha hydrogen show the development of the flare and a subsequent Moreton wave. Although the flare was not detected with the high spectral resolution germanium detectors, the HEAO C-1 CsI shield detected a statistically significant signal above 80 keV, from 420 to 585 keV, and above 3.8 MeV. The temporal structure of microwave, optical, X-ray, and gamma-ray emission is consistent to within about 1 s with a simultaneous flare response at all energies. There is no evidence for either second-stage acceleration of charged particles (Bai and Ramaty, 1979) or a delay between gamma-ray and X-ray continuum emission due to energy-dependent electron energy loss times (Bai and Ramaty).

Riegler, G. R.↗

Cosmic X-ray physics

A progress report of research activities carried out in the area of cosmic X-ray physics is presented. The Diffuse X-ray Spectrometer DXS which has been flown twice as a rocket payload is described. The observation times proved to be too small for meaningful X-ray data to be obtained. Data collection and reduction activities from the Ultra-Soft X-ray background (UXT) instrument are described. UXT consists of three mechanically-collimated X-ray gas proportional counters with window/filter combinations which allow measurements in three energy bands, Be (80-110 eV), B (90-187 eV), and O (e84-532 eV). The Be band measurements provide an important constraint on local absorption of X-rays from the hot component of the local interstellar medium. Work has also continued on the development of a calorimetric detector for high-resolution spectroscopy in the 0.1 keV - 8keV energy range.

Mccammon, D.↗

Dead-time effects in pulse-counting Digicon detectors

The Hubble Space Telescope's High Resolution Spectrograph employs two pulse-counting Digicon detectors to record UV spectra. At higher measured count rates, the intervals between photon arrivals become comparable to the response time of the electronics, so that not every pulse will be counted; this 'paired pulse' effect causes departures from linearity and must be corrected for during raw data reduction. Attention is given to two analytic equations that quantify the dead-time losses. The less attenuated spectra are noted to be severely distorted by these losses; a comparison with the undistorted low count rate data allows a detailed analysis to be made of the pulse-counting characteristics over five decades of input event rates. The present equations and calibration methods should be applicable to all kinds of multichannel pulse-counting detectors.

Ebbets, Dennis C.↗

A measurement concept for hot-spot BRDFs from space

Several concepts for canopy hot-spot measurements from space have been investigated. The most promising involves active illumination and bistatic detection that would allow hot-spot angular distribution (BRDF) measurements from space in a search-light mode. The concept includes a pointable illumination source, such as a laser operating at an atmospheric window wavelength, coupled with a number of high spatial-resolution detectors that are clustered around the illumination source in space, receiving photons nearly coaxial with the reto-reflection direction. Microwave control and command among the satellite cluster would allow orienting the direction of the laser beam as well as the focusing detectors simultaneously so that the coupled system can function like a search light with almost unlimited pointing capabilities. The concept is called the Hot-Spot Search-Light (HSSL) satellite. A nominal satellite altitude of 600 km will allow hot-spot BRDF measurements out to about 18 degrees phase angle. The distributed are taking radiometric measurements of the intensity wings of the hot-spot angular distribution without the need for complex imaging detectors. The system can be operated at night for increased signal-to-noise ratio. This way the hot-spot angular signatures can be quantified and parameterized in sufficient detail to extract the biophysical information content of plant architectures.

Reflectivity↗

ROSAT Science Data Center

This report provides a summary of the Smithsonian Astrophysical Observatory (SAO) ROSAT SCIENCE DATA CENTER (RSDC) activities for the recent years of our contract. Details have already been reported in the monthly reports. The SAO was responsible for the High Resolution Imager (HRI) detector on ROSAT. We also provided and supported the HRI standard analysis software used in the pipeline processing (SASS). Working with our colleagues at the Max Planck in Garching Germany (MPE), we fixed bugs and provided enhancements. The last major effort in this area was the port from VMS/VAX to VMS/ALPHA architecture. In 1998, a timing bug was found in the HRI standard processing system which degraded the positional accuracy because events accessed incorrect aspect solutions. The bug was fixed and we developed off-line correction routines and provided them to the community. The Post Reduction Off-line Software (PROS) package was developed by SAO and runs in the IRAF environment. Although in recent years PROS was not a contractual responsibility of the RSDC, we continued to maintain the system and provided new capabilities such as the ability to deal with simulated AXAF data in preparation for the NASA call for proposals for Chandra. Our most recent activities in this area included the debugging necessary for newer versions of IRAF which broke some of our software. At SAO we have an operating version of PROS and hope to release a patch even though almost all functionality that was lost was subsequently recovered via an IRAF patch (i.e. most of our problems were caused by an IRAF bug).

Murray, Stephen↗

Chandra Observations of the Crab Pulsar as a Function of Pulse Phase

The Chandra X-Ray Observatory was used to observe the Crab Nebula and its pulsar using the LETGS, i.e. the Low-Energy Transmission Grating (LETG) with the High Resolution Camera Spectroscopy detector (HRC-S). Data from the zeroth-order image was utilized to isolate the pulsar from the surrounding nebula and to measure the pulsar emission as a function of pulse phase. HRC timing problems were overcome by developing special techniques to process the data. For the first time, pulsed x-ray emission has been detected at all pulse phases, allowing us to set a new upper limit to the thermal emission from the surface of the neutron star.

Weisskopf, Martin C.↗

Time Variations of Cosmic-Ray Helium Isotopes with BESS-Polar I

The Balloon-borne Experiment with a Superconducting Spectrometer (BESS) is configured with a solenoidal superconducting magnet and a suite of precision particle detectors, including time-of-flight hodoscopes based on plastic scintillators, a silica-aerogel Cherenkov detector, and a high resolution tracking system with a central jet-type drift chamber. The charges of incident particles are determined from energy losses in the scintillators. Their magnetic rigidities (momentum/charge) are measured by reconstructing each particle trajectory in the magnetic field, and their velocities are obtained by using the time-of-flight system. Together, these measurements can accurately identify helium isotopes among the incoming cosmic-ray helium nuclei up to energies in the GeV per nucleon region. The BESS-Polar I instrument flew for 8.5 days over Antarctica from December 13th to December 21st, 2004. Its long-duration flight and large geometric acceptance allow the time variations of isotopic fluxes to be studied for the first time. The time variations of helium isotope fluxes are presented here for rigidities from 1.2 to 2.5 GV and results are compared to previously reported proton data and neutron monitor data.

Cosmic-ray flux time variations↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Silicon solid/state linear arrays for multispectral high resolution imaging systems

Solid-state, electronically scanned, linear detector arrays are now available which can be used in a pushbroom scan mode imaging system for high-resolution multispectral earth resource survey applications. These arrays provide high performance in the visible to near-IR region. Two performance criteria must be assessed in the choice of a detector array: signal-to-noise ratio and spectral response. Consideration of diffraction limitations shows that optics size cannot be significantly reduced by using very low-noise detectors. The required spectral response for a viable detector array should not have spectral ripples that cause a low-level, but significant, error in the detected effective reflectance of the target.

Thompson, L. L.↗