Search NASA⌕ Search

SEARCH · Search NASA

Results for “homogeneous algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Enforcing global constraints for the dispersion closure problem: τ 2 -SIMPLE algorithm

Permeability and effective dispersion tensors are critical parameters to characterize flow and transport in porous media at the continuum scale. Homogenization theory defines a framework in which such effective properties are first computed from solving a closure problem in a repeating unit cell of the periodic microstructure and then used in a macroscopic formulation for efficient computation. The closure problem is formulated as a local boundary value problem subjected to global constraints, which guarantee the uniqueness of the solution and can be difficult to satisfy for complex geometries and at high flow conditions. These constraints also ensure that pore-scale pressure, velocity, and concentration fields can be accurately reconstructed from the closure variable. Building on a previous work, here we present a framework that allows to satisfy global constraints associated to both the permeability and the dispersion closure problems by introducing two artificial time scales. The algorithm, called τ 2 -SIMPLE, computes both permeability and effective dispersion given an arbitrarily complex geometry and flow condition. Furthermore, this algorithm is demonstrated to be accurate for both 2D and 3D geometries across varying flow conditions, and thus it can be used to quickly characterize effective properties from porous media images in many applications.

97 MATHEMATICS AND COMPUTING↗

Target Detection in SAR Images Based on a Level Set Approach

This paper introduces a new framework for point target detection in synthetic aperture radar (SAR) images. We focus on the task of locating reflective small regions using alevel set based algorithm. Unlike most of the approaches in image segmentation, we address an algorithm which incorporates speckle statistics instead of empirical parameters and also discards speckle filtering. The curve evolves according to speckle statistics, initially propagating with a maximum upward velocity in homogeneous areas. Our approach is validated by a series of tests on synthetic and real SAR images and compared with three other segmentation algorithms, demonstrating that it configures a novel and efficient method for target detection purpose.

97 MATHEMATICS AND COMPUTING↗

Mathematical model of massive dynamics in the neighborhood of disturbance focus

We consider a model problem for the research of Earth’s surface state caused by discharge of tectonic stress on the deep cracks in the earth’s crust. Using the numerical method of bicharacteristics, algorithm is developed and solution of the problem of non-stationary dynamics of a homogeneous isotropic elastic half-space is built under plane strain when one resets the vertical stress on crack. Diffraction of waves on the surface is studied, pictures of wave fields and stress-strain state of the medium and the surface for different moments of time are built.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-consistent clustering analysis: an efficient multiscale scheme for inelastic heterogeneous materials

A predictive computational theory is shown for modeling complex, hierarchical materials ranging from metal alloys to polymer nanocomposites. The theory can capture complex mechanisms such as plasticity and failure that span across multiple length scales. This general multiscale material modeling theory relies on sound principles of mathematics and mechanics, and a cutting-edge reduced order modeling method named self-consistent clustering analysis (SCA) [Zeliang Liu, M.A. Bessa, Wing Kam Liu, “Self-consistent clustering analysis: An efficient multi-scale scheme for inelastic heterogeneous materials,” Comput. Methods Appl. Mech. Engrg. 306 (2016) 319–341]. SCA reduces by several orders of magnitude the computational cost of micromechanical and concurrent multiscale simulations, while retaining the microstructure information. This remarkable increase in efficiency is achieved with a data-driven clustering method. Computationally expensive operations are performed in the so-called offline stage, where degrees of freedom (DOFs) are agglomerated into clusters. The interaction tensor of these clusters is computed. In the online or predictive stage, the Lippmann-Schwinger integral equation is solved cluster-wise using a self-consistent scheme to ensure solution accuracy and avoid path dependence. To construct a concurrent multiscale model, this scheme is applied at each material point in a macroscale structure, replacing a conventional constitutive model with the average response computed from the microscale model using just the SCA online stage. A regularized damage theory is incorporated in the microscale that avoids the mesh and RVE size dependence that commonly plagues microscale damage calculations. The SCA method is illustrated with two cases: a carbon fiber reinforced polymer (CFRP) structure with the concurrent multiscale model and an application to fatigue prediction for additively manufactured metals. For the CFRP problem, a speed up estimated to be about 43,000 is achieved by using the SCA method, as opposed to FE2, enabling the solution of an otherwise computationally intractable problem. The second example uses a crystal plasticity constitutive law and computes the fatigue potency of extrinsic microscale features such as voids. This shows that local stress and strain are capture sufficiently well by SCA. This model has been incorporated in a process-structure-properties prediction framework for process design in additive manufacturing.

Liu, Z.↗

Determination of monitor unit check tolerances based on a comparison with measurement and treatment planning system data

ABSTRACT: This work describes the experimental validation of treatment planning system monitor unit (MU) calculations against measurement for a range of scenarios. This, together with a comparison of treatment planning system MUs and an independent MU check method, allows the derivation of confidence intervals for the check process. Data were collected for open and 60° motorized wedge fields using an Elekta Synergy linac at 6 and 8 MV using homogeneous and heterogeneous phantoms. Masterplan (Version 4.0) pencil-beam and collapsed cone algorithms were used for the primary MU calculations with full inhomogeneity correction. Results show that both algorithms agree with measurement to acceptable tolerance levels in the majority of the cases studied. The confidence interval for the pencil-beam algorithm MU against an independent check was determined as + 1.6% to −3.4%. This is modified to + 2.3% to −2.5% when data collected with low-density heterogeneities are removed as this algorithm is not used clinically for these cases. The corresponding interval for the collapsed cone algorithm was + 1.2% to −4.3%, indicating that an offset tolerance for the independent check is appropriate. Analysis of clinical conformal treatment plan data generated using the pencil-beam algorithm (1393 beams) returned 93% of beams within the independent check tolerance. Similarly, using the collapsed cone algorithm as the primary MU calculation, 77% (of 1434 beams) were within the confidence interval.

61 RADIATION PROTECTION AND DOSIMETRY↗

Super‐Droplet Method to Simulate Lagrangian Microphysics of Nuclear Fallout in a Homogeneous Cloud

Abstract Nuclear detonations produce hazardous local and global particles or fallout. Predicting fallout size, chemical components, and location is necessary to inform officials and determine immediate guidance for the public. However, existing nuclear detonation fallout models prescribe the particle size distributions based on limited observations. In this work, we apply the super‐droplet method, which is a numerical modeling technique developed for cloud microphysics, to simulate size distributions of particles in a mushroom cloud formed post‐detonation of a nuclear device. We model fallout formation and evolution with homogeneous nucleation and condensation of a single species and a Monte Carlo coagulation algorithm. We verify the numerical methods representing coagulation and condensation processes against analytical test problems. Additionally, we explore several scenarios for the integral system mass and yield in equivalent kilotons (kt) of TNT (trinitrotoluene). The fallout size distribution median diameter d pg follows a scaling law based on the integral system mass m v 0 kg and yield Y kt: nm. We test the effect of cloud turbulence, enhanced nucleation and growth, and vapor volatility with a sensitivity study. The range in median diameter predictions for simulations of historical tests performed over the Pacific encompass the measurements of particles sampled from the cloud caps. Predicted median particle size ranges up to 217, 123, 86, and 35 nm for historical tests with yields of 0.2, 0.7, 2, and 10 Mt, respectively. This work can be expanded in many different directions to build a more predictive model for fallout formation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

HPC-Enabled Optimization of High Temperature Heat Exchangers (CRADA Final Report)

This project was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS) as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Materials Sciences, LLC, to develop a technology for design and optimization of heat exchangers using powerful desktop and laptop computers. The project was originally designated as a 12-month project, and consisted of 3# major tasks and the following 8# major deliverables: 1) CFD models of 3D heat exchangers based on existing and new geometry. 2) Validation against experimental data provided by MSC and published in the literature. 3) CFD models of 3D unit cells based on TPMS. 4) Surrogate models capable of delivering the gradients of the homogenized properties with respect to the parametrization. 5) 3D design methodology using TO algorithms. 6) Conventional reference and topology optimized designs. 7) 3D optimized designs stored in a 3D printer build format. 8) Verification of the improved performance. All of the deliverables for this project were successfully completed with two no-cost time extensions.

36 MATERIALS SCIENCE↗

HPC-Enabled Optimization of High Temperature Heat Exchangers (CRADA Final Report)

This project was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS) as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Materials Sciences, LLC, to develop a technology for design and optimization of heat exchangers using powerful desktop and laptop computers. The project was originally designated as a 12-month project, and consisted of 3# major tasks and the following 8# major deliverables: 1) CFD models of 3D heat exchangers based on existing and new geometry. 2) Validation against experimental data provided by MSC and published in the literature. 3) CFD models of 3D unit cells based on TPMS. 4) Surrogate models capable of delivering the gradients of the homogenized properties with respect to the parametrization. 5) 3D design methodology using TO algorithms. 6) Conventional reference and topology optimized designs. 7) 3D optimized designs stored in a 3D printer build format. 8) Verification of the improved performance. All of the deliverables for this project were successfully completed with two no-cost time extensions.

13 HYDRO ENERGY↗

Programming substructure computations for elliptic problems on the CHiP system

A number of studies have been conducted with the aim to apply parallel computation to problems associated with solving finite element equations arising in structural mechanics and fluid dynamics. These studies have provided many important results. The present investigation is concerned with a set of experiments designed to test two ideas, including configurability and substructuring. The considered algorithms and tests are intended for implementation on the Configurable, Highly Parallel (CHiP) family of architecture described by Snyder (1982). The ChiP computer is composed of homogeneous processing elements (PEs) placed at regular intervals in a lattice of programmable switches. Two examples of the role of configurability and substructuring for simple iterative algorithms are considered, giving attention to conjugate gradient iterations, and tridiagonal systems of equations.

Gannon, D.↗

Hypercube technology

The JPL designed MARKIII hypercube supercomputer has been in application service since June 1988 and has had successful application to a broad problem set including electromagnetic scattering, discrete event simulation, plasma transport, matrix algorithms, neural network simulation, image processing, and graphics. Currently, problems that are not homogeneous are being attempted, and, through this involvement with real world applications, the software is evolving to handle the heterogeneous class problems efficiently.

Parker, Jay W.↗

SU-E-J-252: A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction

Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embedded into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.

60 APPLIED LIFE SCIENCES↗

Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams. Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics. Results: Measured outputs agree with calculated values within estimated uncertainties for standard and extended SSDs for open applicators, and for cutouts, with the exception of the 17 MeV electron beam at extended SSD for cutout sizes smaller than 5 × 5 cm{sup 2}. Good agreement was obtained between calculated and experimental depth dose curves and dose profiles (minimum number of measurements that pass a 2%/2 mm agreement 2D gamma index criteria for any applicator or energy was 97%). Dose calculations in a heterogeneous phantom agree with radiochromic film measurements (>98% of pixels pass a 3 dimensional 3%/2 mm γ-criteria) provided that the steep dose gradient in the depth direction is considered. Conclusions: Clinically acceptable agreement (at the 2%/2 mm level) between the measurements and calculated data for measurements in water are obtained for this dose calculation algorithm. Radiochromic film is a useful tool to evaluate the accuracy of electron MC treatment planning systems in heterogeneous media.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-BRB-03: Cross-Institutional Validation of An Ultrafast Automatic Planning Platform for Breast Irradiation

Purpose: Recently an ultrafast automatic planning system for breast irradiation using tangential beams was developed by modeling relationships between patient anatomy and achieved dose distribution. This study evaluates the performance of this system when applied to a different patient population and dose calculation algorithm. Methods: The system and its anatomy-to-dose models was developed at institution A based on 20 cases, which were planned using manual fluence painting technique and calculated WITH heterogeneity correction. Institution B uses field-in-field planning technique and dose calculation WITHOUT heterogeneity correction. 11 breast cases treated at Institution B were randomly selected for retrospective study, including left and right sides, and different breast size (irradiated volumes defined by Jaw/MLC opening range from 875cc to 3516cc). Comparisons between plans generated automatically (Auto-Plans) and those used for treatment (Clinical-Plans) included: energy choice (single/mixed), volumes receiving 95%/100%/105%/110% Rx dose (V95%/V100%/V105%/V100%) relative to irradiated volume, D1cc, and LungV20Gy. Results: In 9 out of 11 cases single/mixed energy choice made by the software agreed with Clinical-Plans. For the remaining 2 cases software recommended using mixed energy and dosimetric improvements were observed. V100% were similar (p=0.223, Wilcoxon Signed-Rank test) between Auto-Plans and Clinical-Plans (57.6±8.9% vs. 54.8±9.5%). V95% is 2.3±3.0% higher for Auto-Plans (p=0.027), indicating reduced cold areas. Hot spot volume V105% were significantly reduced in Auto-Plan by 14.4±7.2% (p=0.004). Absolute V105% was reduced from 395.6±359.9cc for Clinical-Plans to 108.7±163cc for Auto-Plans. D1cc was 107.4±2.8% for Auto-Plans, and 109.2±2.4% for Clinical-Plans (p=0.056). LungV20Gy were 13.6±4.0% for Auto-Plan vs. 14.0±4.1% for Clinical-Plans (p=0.043). All optimizations were finished within 1.5min. Conclusion: The performance of this breast auto-planning system remained stable and satisfactory when applied to a different patient population and dose calculation algorithm. The auto-planning system was able to produce clinically similar Rx dose coverage with significantly improved homogeneity inside breast tissue, in less than 1.5min.

60 APPLIED LIFE SCIENCES↗

Efficient generation of grids and traversal graphs in compositional spaces towards exploration and path planning

Abstract Diverse disciplines across science and engineering deal with problems related to compositions, which exist in non-Euclidean simplex spaces, rendering many standard tools inaccurate or inefficient. This work explores such spaces conceptually in the context of materials discovery, quantifies their computational feasibility, and implements several essential methods specific to simplex spaces through a new high-performance open-source library . Most significantly, we derive and implement an algorithm for constructing a novel n-dimensional simplex graph data structure, containing all discretized compositions and possible neighbor-to-neighbor transitions. Critically, no distance or neighborhood calculations are performed, instead leveraging pure combinatorics and order in procedurally generated simplex grids, keeping the algorithm $${\mathcal{O}}(N)$$ O ( N ) , with minimal memory, enabling rapid construction of graphs with billions of transitions in seconds. Additionally, we demonstrate how such graph representations can be combined to homogeneously express complex path-planning problems, while facilitating efficient deployment of existing high-performance gradient descent, graph traversal, and other optimization algorithms.

Krajewski, Adam M. (ORCID:0000000222660099)↗

Combined Weekly Coordinate Solutions from SLR and DORIS

In International Terrestrial Reference Frame (ITRF) 2005 and ITRF2008, the approach for the construction of solutions by the IERS has been for individual analysis centers of each technique to process geodetic tracking data, and for each technique to develop a solution (or contribution) that is integrated into the final ITRF solution by careful combination of the technique solutions. The connections between the geodetic networks are realized by the application of local ties. In an alternate approach, we may assure processing homogeneity by creating normal equations for different techniques with the same orbit determination software, using identically derived algorithms. Another derivative of this approach is to realize the ties between the techniques using satellites tracked with multiple techniques; in effect tieing the networks together using satellite dynamics. In this solution, we develop a time series and a set of cumulative solutions from Satellite Laser Ranging (SLR) & Doppler Orbitography and Radio-positioning Integrated by Satellite (DORIS) based on homogeneous processing with the NASA GEODYN precise orbit determination suite of programs, where we jointly combine weekly the SLR data to Lageos1, Lageos2, Starlette, and Stella with the DORIS data from SPOT2-SPOT5, as well as satellites that utilize both techniques (TOPEX/Poseidon, Envisat, Jason-2). We discuss the modeling that is applied including upgrades implemented since the submission of the GSC ITRF2008 contributions for IDS. Firstly, we compare the SLR-only solutions comprising four geodetic satellites with the standard approach of utilizing only Lageos1 & Lageos2. Secondly, we evaluate the impact on the DORIS coordinates of the joint analysis with the SLR data.

Lemoine, F.↗

Deep near-infrared survey of the Southern Sky (DENIS)

DENIS (Deep Near-Infrared Survey of the Southern Sky) will be the first complete census of astronomical sources in the near-infrared spectral range. The challenges of this novel survey are both scientific and technical. Phenomena radiating in the near-infrared range from brown dwarfs to galaxies in the early stages of cosmological evolution, the scientific exploitation of data relevant over such a wide range requires pooling expertise from several of the leading European astronomical centers. The technical challenges of a project which will provide an order of magnitude more sources than given by the IRAS space mission, and which will involve advanced data-handling and image-processing techniques, likewise require pooling of hardware and software resources, as well as of human expertise. The DENIS project team is composed of some 40 scientists, computer specialists, and engineers located in 5 European Community countries (France, Germany, Italy, The Netherlands, and Spain), with important contributions from specialists in Australia, Brazil, Chile, and Hungary. DENIS will survey the entire southern sky in 3 colors, namely in the I band at a wavelength of 0.8 micron, in the 1.25 micron J band, and in the 2.15 micron K' band. The sensitivity limits will be 18th magnitude in the I band, 16th in the J band, and 14.5th in the K' band. The angular resolution achieved will be 1 arcsecond in the I band, and 3.0 arcseconds in the J and K' bands. The European Southern Observatory 1 m telescope on La Silla will be dedicated to survey use during operations expected to last four years, commencing in late 1993. DENIS aims to provide the astronomical community with complete digitized infrared images of the full southern sky and a catalogue of extracted objects, both of the best quality and in readily accessible form. This will be achieved through dedicated software packages and specialized catalogues, and with assistance from the Leiden and Paris Data Analysis Centers. The data will be mailed on DAT tapes from La Silla to the two Data Analysis Centers for further processing. Two centers are necessary because of the shear quantity of data and because of the complementary roles the Centers will develop, each exploiting its own particular expertise. The Leiden Data Analysis Center (LDAC) will extract objects, establish their parameters, and archive them into a source catalogue. The LDAC will collaborate with the Groningen Space Research group that has gained experience in infrared image handling from the IRAS satellite. The Paris Data Analysis Center (PDAC) will be responsible for archiving and preprocessing the raw data to provide a homogeneous set of data suitable for further reduction in both the Leiden and Paris data analysis streams. The PDAC will also extract and archive images for the sources flagged by the LDAC as extended, and create a catalogue of galaxies. In exploiting the DENIS data we foresee the collaboration with other data analysis centers, such as the Observatoire de Lyon where the relevant DENIS catalogue of galaxies can be incorporated into their extragalactic database. The Point Sources and the Small Extended Sources catalogues could be incorporated in the Late Type Star database at Montpellier, and in the SIMBAD database as CDS. At Groningen the IRAS Point Source catalogue and/or image data can be merged with the DENIS catalogues. At Meudon algorithms and software will be developed with main goal assessing the limits reachable for the homogeneity and intrinsic consistency between the ensemble of the images in the data base (flat-fielding, relative positioning of the fields, bootstrapped flux calibration) but also for the data analysis.

Deul, E.↗

A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning

Monte Carlo (MC) simulation is currently the most accurate dose calculation algorithm in radiotherapy planning but requires relatively long processing time. Faster model-based algorithms such as the anisotropic analytical algorithm (AAA) by the Eclipse treatment planning system and multigrid superposition (MGS) by the XiO treatment planning system are 2 commonly used algorithms. This study compared AAA and MGS against MC, as the gold standard, on brain, nasopharynx, lung, and prostate cancer patients. Computed tomography of 6 patients of each cancer type was used. The same hypothetical treatment plan using the same machine and treatment prescription was computed for each case by each planning system using their respective dose calculation algorithm. The doses at reference points including (1) soft tissues only, (2) bones only, (3) air cavities only, (4) soft tissue-bone boundary (Soft/Bone), (5) soft tissue-air boundary (Soft/Air), and (6) bone-air boundary (Bone/Air), were measured and compared using the mean absolute percentage error (MAPE), which was a function of the percentage dose deviations from MC. Besides, the computation time of each treatment plan was recorded and compared. The MAPEs of MGS were significantly lower than AAA in all types of cancers (p<0.001). With regards to body density combinations, the MAPE of AAA ranged from 1.8% (soft tissue) to 4.9% (Bone/Air), whereas that of MGS from 1.6% (air cavities) to 2.9% (Soft/Bone). The MAPEs of MGS (2.6%±2.1) were significantly lower than that of AAA (3.7%±2.5) in all tissue density combinations (p<0.001). The mean computation time of AAA for all treatment plans was significantly lower than that of the MGS (p<0.001). Both AAA and MGS algorithms demonstrated dose deviations of less than 4.0% in most clinical cases and their performance was better in homogeneous tissues than at tissue boundaries. In general, MGS demonstrated relatively smaller dose deviations than AAA but required longer computation time.

61 RADIATION PROTECTION AND DOSIMETRY↗

A modified formula for dose calculations of stereotactic ablative body radiotherapy for non–small cell lung cancer

To provide a modified formula consistent with the Monte Carlo (MC) algorithm for dose calculations during stereotactic ablative body radiotherapy for non–small cell lung cancer. Seventy CyberKnife treatment plans were calculated and analyzed by MC and ray-tracing (RT) algorithms, separately. Parameters of treatment plans were compared, and those associated with differences of dose distributions were analyzed to establish a modified formula. Gross tumor volume and tumor tracking volume (TTV) were defined as the evident disease on the sequences of the window width and level of the lung and the mediastinum. Additionally, the formula was validated by another 20 plans. The prescription dose of the 90 patients was 60 Gy/5f. The RT algorithm overestimated the planning target volume (PTV) D{sub 95} by an average of 8.59 Gy and the gross tumor volume D{sub 99} by an average of 5.84 Gy. The homogeneity index of PTV was underestimated by 0.11 on average, whereas the conformity index and new conformity index was underestimated by 0.05. The RT algorithm overestimated the dose distribution to the spinal cord by 2.23 Gy, the esophagus by 1.96 Gy, the trachea by 1.89 Gy, the left-sided bronchus by 1.77 Gy, the right-sided bronchus by 1.64 Gy, and the heart by 2.16 Gy. The average whole-lung dose volumes of lung tissues and dose volumes of V{sub 5} were overestimated by 2.69 Gy and 7.52%, respectively. A power function distribution (R{sup 2} = 0.8626) was confirmed between PTV D{sub 95} and TTV volumes. PTV D{sub 95} calculated by the MC algorithm could be computed easily with TTV and PTV D{sub 95} calculated by the RT algorithm based on the formula. The modified equation was more consistent with MC algorithm than with other formula, which could be a reference to those not accessible to the MC algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗