Search NASA⌕ Search

SEARCH · Search NASA

Results for “immersive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A numerical comparison with an exact solution for the transient response of a cylinder immersed in a fluid

The transient response of an elastic cylindrical shell immersed in an acoustic media that is engulfed by a plane wave is determined numerically. The method applies to the USA-STAGS code which utilizes the finite element method for the structural analysis and the doubly asymptotic approximation for the fluid-structure interaction. The calculations are compared to an exact analysis for two separate loading cases: a plane step wave and an exponentially decaying plane wave.

Giltrud, M. E.↗

Investigation of electrical noise in selenium-immersed thermistor bolometers

The selenium immersed, thermistor bolometer, IR detector failed due to spurious and escalating electrical noise outburst as a function of time at elevated temperatures during routine ground based testing in a space simulated environment. Spectrographic analysis of failed bolometers revealed selenium pure zones in the insulating selenium arsenic (Se-As) glass film which surrounds the active sintered Mn, Ni, Co oxide flake. The selenium pure film was identified as a potentially serious failure mechanism. Significant changes were instituted in the manufacturing techniques along with more stringent process controls which eliminated the selenium pure film and successfully produced 22study bolometers.

Tarpley, J. L.↗

Liquid immersion apparatus for minute articles

Apparatus is disclosed for immersing minute integrated circuit chips in an etching solution in manufacturing integrated circuits during research and development. The apparatus includes a holder, having a handle and basket support for carrying a removable unitary basket and lid structure where fluid flow-through passages are formed, and wherein graduated openings in the handle provide for adjustably supporting the basket in a breaker at a desired level.

Belcher, J. G., Jr.↗

Effects of water immersion on plasma catecholamines in normal humans

An investigation was conducted in order to determine whether water immersion to the neck (NI) alters plasma catecholamines in normal humans. Eight normal subjects were studied during a seated control study (C) and during 4 hr of NI, and the levels of norepinephrine (NE) and epinephrine (E) as determined by radioenzymatic assay were measured hourly. Results show that despite the induction of a marked natriuresis and diuresis indicating significant central hypervolemia, NI failed to alter plasma NE or E levels compared with those of either C or the corresponding prestudy 1.5 hr. In addition, the diuresis and natriuresis was found to vary independently of NE. These results indicate that the response of the sympathetic nervous system to acute volume alteration may differ from the reported response to chronic volume expansion.

Epstein, M.↗

Comparison of immersed liquid and air cooling of NASA's Airborne Information Management System

The Airborne Information Management System (AIMS) is currently under development at NASA Dryden Flight Research Facility. The AIMS is designed as a modular system utilizing surface mounted integrated circuits in a high-density configuration. To maintain the temperature of the integrated circuits within manufacturer's specifications, the modules are to be filled with Fluorinert FC-72. Unlike ground based liquid cooled computers, the extreme range of the ambient pressures experienced by the AIMS requires the FC-72 be contained in a closed system. This forces the latent heat absorbed during the boiling to be released during the condensation that must take within the closed module system. Natural convection and/or pumping carries the heat to the outer surface of the AIMS module where the heat transfers to the ambient air. This paper will present an evaluation of the relative effectiveness of immersed liquid cooling and air cooling of the Airborne Information Management System.

Hoadley, A. W.↗

Plasma volume shifts and exercise thermoregulation with water immersion and six-degree head-down tilt

The hypothesized fluid shifts and resultant responses that occur during spaceflight are simulated by six-degree head down tilt (HDT) and water immersion (WI). The purpose of this study was to compare exercise thermoregulation before and after physiologic mechanisms reduce plasma volume (PV) in response to 24-hr HDT (HDT24). A secondary study utilized WI to reproduce the PV reduction of HDT24. Seven males were studied in two conditions: during 70 minutes of supine cycling ergometry at 58 percent of peak oxygen consumption following 1-hr HDT (HDT1) and HDT24; and up to 6 hr WI at 34.5 C. Plasma volume was reduced by 10.4 percent in HDT24 when compared to HDT1. Pre-exercise rectal temperature, T(sub re), was an average 0.22 C higher after HDT24. Rectal temperature increased during exercise with no interaction between time and treatment. The reduced PV and elevated pre-exercise T(sub re) had offsetting effects on thermoregulatory mechanisms, suggesting no alteration in the response at a given T(sub re). Plasma volume was reduced by 4.3 +/- 2.3 percent and 1.1 +/- 1.8 percent following HDT24 and WI, respectively, compared to upright chair rest. Although the reductions in PV were not significantly different, great intra-individual variability was evident. The ability to reproduce PV changes consistently with HDT and WI is limited by this variability.

Ertl, Andrew Carl↗

Effects of oral glucose on exercise thermoregulation in men after water immersion

To test the hypothesis elevated blood glucose would attenuate the rise in exercise rectal temperature, six men age 35 plus or minus S.D. 7 years participated in each of three trials by 4-hr water immersion to the neck: (1) 2.0 g/kg body wt of oral glucose (33.8 percent wt./vol.) was consumed followed by 80 min controlled rest (Glu/Rest), and 70 min horizontal supine cycle exercise at 62.8 percent plus or minus S.E. 0.5 percent (1.97 plus or minus 0.02 L/min) of peak O2 uptake followed by 10 min recovery (2) with (Glu/Ex) and (3) without prior flucose (No Glu/Ex). Blood samples were taken at -25, 0, 15, 45, and 68 min of exercise and after plus 10 min of recovery for measurement of hemoglobin, hematocrit, and blood glucose. Both mean skin (T sub sk) (from six sites) and rectal temperatures (T sub re) were monitored continuously. Sweat rate was measured by resistanc hygrometry. The mean of delta PV for the exercise trials was -12.2 plus or minus 2.1 percent. Mean blood glucose for the Glu/Ex trial was higher than that of the No Glu/Ex trial was (108.4 equal or minus 3.9 and 85.6 plus or minus 1.6 mg/dl, respectively, P less than 0.05. At the end of exercise T(sub sk) for the Glu/Ex trial was lower than for No Glu/Ex(32.0 plus or minus 0.3 and 32.4 equals or minus 0.2 C, respectively, P less than 0.05); T(sub re) for the Glu/Ex trial was lower than for No Glu/Es (38.22 plus or minus 0.17 and 38.60 plus or minus 0.11 C, respectively, P less than 0.05); and forearm sweat rate for the Glu/Ex trial (0.34 plus or minus 0.04 and 0.43 plus or minus g/sq cm, respectively, P less than 0.05). These data suggest that elevation of blood glucose prior to horizontal exercise following hypohydration attenuates the increase in body temperature without altering heat production or exercise hypovolemia.

Dearborn, Alan S.↗

Tracking a turbulent spot in an immersive environment

We describe an interactive, immersive 3D system called Tracktur, which allows a viewer to track the development of a turbulent flow. Tracktur displays time-varying vortex structures extracted from a numerical flow simulation. The user navigates the space and probes the data within a windy 3D landscape. In order to sustain a constant frame rate, we enforce a fixed polygon budget on the geometry. We supplement the interactive system with interactive, hypertext documentation available on the World Wide Web. In actual use by a fluid dynamicist, the system has yielded new insights into the transition to turbulence in a laminar flow.

Banks, David C.↗

Three-Dimensional User Interfaces for Immersive Virtual Reality

The focus of this grant was to experiment with novel user interfaces for immersive Virtual Reality (VR) systems, and thus to advance the state of the art of user interface technology for this domain. Our primary test application was a scientific visualization application for viewing Computational Fluid Dynamics (CFD) datasets. This technology has been transferred to NASA via periodic status reports and papers relating to this grant that have been published in conference proceedings. This final report summarizes the research completed over the past year, and extends last year's final report of the first three years of the grant.

vanDam, Andries↗

Noble Metal Immersion Spectroscopy of Silica Alcogels and Aerogels

We have fabricated aerogels containing gold and silver nanoparticles for gas catalysis applications. By applying the concept of an average or effective dielectric constant to the heterogeneous interlayer surrounding each particle, we extend the technique of immersion spectroscopy to porous or heterogeneous media. Specifically, we apply the predominant effective medium theories for the determination of the average fractional composition of each component in this inhomogeneous layer. Hence, the surface area of metal available for catalytic gas reaction is determined. The technique is satisfactory for statistically random metal particle distributions but needs further modification for aggregated or surfactant modified systems. Additionally, the kinetics suggest that collective particle interactions in coagulated clusters are perturbed during silica gelation resulting in a change in the aggregate geometry.

Smith, David D.↗

Heat Acclimation and Water-Immersion Deconditioning: Fluid Electrolyte Shifts with Tilting

One of the major problems encountered by astronauts exposed to space flight is a reduction of orthostatic tolerance on return to earth. Many studies have been performed in an attempt to define the physiologic mechanism of orthostatic intolerance and to develop some remedial treatment. Exercise training does not appear to enhance orthostatic tolerance . In contrast, heat acclimation (i.e., exercise training in the heat) has been reported to enhance orthostatic tolerance. Since plasma volume increases with both exercise training and heat acclimation, it is not clear what role fluid and electrolytes play in determining tolerance to hydrostatic pressure. The purpose of this study was to compare the effects of exercise training in a cool environment and heat acclimation on resting plasma volume (PV) and the ensuing fluid and electrolyte shifts which occur during head-up tilting before and after water immersion deconditioning.

Conertino, V. A.↗

Exercise Thermoregulation After 6 hours of Chair Rest, 6 deg Head-Down Bed-Rest, and Water Immersion Deconditioning in Men

The purpose was to investigate the mechanism for the excessive exercise hyperthermia following deconditioning (reduction of physical fitness). Rectal (T(sub re)) and mean skin (T(bar)(sub sk)) temperatures and thermoregulatory responses were measured in six men [mean (SD) age, 32 (6) years; mass, 78.26 (5.80) kg; surface area, 1.95 (0.11) sq m; maximum oxygen uptake (VO2max), 48 (6) ml/min/kg; whilst supine in air at dry bulb temperature 23.2 (0.6)C, relative humidity 31.1 (11.1)% and air speed 5.6 (0.1) m/min] during 70 min of leg cycle exercise [51 (4)% VO2max] in ambulatory control (AC), or following 6 h of chair rest (CR), 6deg head-down bed rest (BR), and 20deg (W120) and 80deg (W180) foot-down water immersion [water temperature, 35.0 (0.1) C]. Compared with the AC exercise (Delta)T(sub re) [mean (SD) 0.77 (0.13)C], (Delta)T(sub re), after CR was 0.83 (0.08)C (NS), after BR 0.92 (0.13)C (*P <0.05), after W180 0.96 (0.13)C*, and after W120 1.03 (0.09)C*. All T(sub sk) responded similarly to exercise: they decreased (NS) by 0.5-0.7 C in minutes 4-8 and equilibrated at +0.1 to +0.5 C at 60-70. Skin heat conductance was not different among the five conditions (range = 147-159 kJ/sq/C. Results from an intercorrelation matrix suggested that total body sweat rate was more closely related to T(sub re) at 70 min (T(sub re70)) than limb sweat rate or blood flow. Only 36% of the variability in T(sub re70) could be accounted for by total sweating, and less than 10% from total body dehydration. It would appear that multiple factors are involved which may include change in sensitivity of thermo- and osmoreceptors.

Greenleaf, J. E.↗

Development of a Submillimeter-Wavelength Immersion Grating Spectrometer

The broad goal of this project was to develop a broadband, moderate-resolution spectrometer for submillimeter wavelengths. Our original approach was to build an immersion grating spectrometer, and as such, the first step was to identify the best material (lowest loss, highest index) for the grating medium, and to characterize its properties at the foreseen optical-bench operating temperature of 1.5 K. To this end, we put our initial efforts into upgrading an existing laboratory submillimeter Fourier transform spectrometer, which allowed us to carry out the requisite materials measurements. The associated cryogenic detector dewar was also redesigned and rebuilt to carry out this work. This dewar houses the 1.5 K detector and the filter wheel used in the materials characterization. Our goal was to have the beam propagate through the samples as uniformly as possible, so the optics were redesigned to allow for the samples to be traversed by a well-defined collimated beam. The optics redesign also placed the samples at an image of the aperture stop located within the FTS. After the rebuild, we moved into the testing phase.

Phillips, T. G.↗

Arc Inception Mechanism on a Solar Array Immersed in a Low-Density Plasma

In this report, results are presented of an experimental and theoretical study of arc phenomena and snapover for two samples of solar arrays immersed in argon plasma. The effects of arcing and snapover are investigated. I-V curves are measured, and arc and snapover inception voltages and arc rates are determined within the wide range of plasma parameters. A considerable increase in arc rate due to absorption of molecules from atmospheric air has been confirmed. It is shown that increasing gas pressure causes increasing ion current collection and, consequently, arc rate even though the effect of conditioning also takes place. Arc sites have been determined by employing a video-camera. It is confirmed that keeping sample under high vacuum for a long time results in shifting arc threshold voltage well below -300 V. The results obtained seem to be important for the understanding of arc inception mechanism.

Vayner, B.↗

The Electrostatic Breakdown on Metal-Dielectric Junction Immersed in a Plasma

New results are presented of an experimental study and theoretical analysis of arcing on metal-dielectric junctions immersed in low-density plasmas. Two samples of conventional solar arrays and four different metal-quartz junctions have been used to investigate the effects of arcing within a wide range of neutral gas pressures, ion currents, and electron number densities. The effect of surface conditioning (decrease of arc rate due to outgassing) was clearly demonstrated. Moreover, a considerable increase in arc rate due to absorption of molecules from atmospheric air has been confirmed. It has been proved that the are inception mechanism in plasma is different from one in vacuum.

Vayner, Boris V.↗

Visualization of CFD Results in Immersive Virtual Environments

An object-oriented event-driven immersive virtual environment (VE) is described for the visualization of computational fluid dynamics (CFD) results. The VE incorporates the following types of primitive software objects: interface objects, support objects, geometric entities, and finite elements. The fluid domain is discretized using either a multi-block structured grid or an unstructured finite element mesh. The VE allows natural 'fly-through' visualization of the model, the CFD grid, and the model's surroundings. In order to help visualize the flow and its effects on the model, the VE incorporates the following objects: stream objects (lines, surface-restricted lines. ribbons. and volumes); colored surfaces; elevation surfaces; surface arrows; global and local iso-surfaces; vortex cores; and separation/attachment surfaces and lines. Most of these objects can be used for dynamically probing the flow. Particles and arrow animations can be displayed on top of stream objects. Primitive response quantities as well as derived quantities can be used. A recursive tree search algorithm is used for real-time point and value search in the CFD grid.

Wasfy, Tamer M.↗