Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Overcoming Resilience Challenges on the Outer Banks of North Carolina

In 2021, the Town of Nags Head, located in the Outer Banks region of North Carolina, was among the first cohort of coastal and island communities to participate in the U.S. Department of Energy's Energy Transitions Initiative Partnership Project (ETIPP), which offers technical assistance and cash awards to competitively selected coastal, remote, and island communities seeking to transform their energy systems and increase their energy resilience. As a barrier island separated from mainland North Carolina, Nags Head experiences impacts from extreme weather events, including power outages, especially during hurricane season. To address challenges, the Nags Head ETIPP team sought to improve the town's disaster resilience by ensuring that critical facilities can remain powered during and after extreme events. With support from experts at Sandia National Laboratories, the National Renewable Energy Laboratory, and the Coastal Studies Institute, the community team identified the following goals for its participation in ETIPP: 1. Identify and prioritize critical facilities that, when powered during disruptions, support the town's resilience. 2. Analyze the potential for on-site solar photovoltaic (PV) and storage systems at 2-4 prioritized critical facilities owned and/or operated by the town. 3. Analyze the potential for interconnecting solar PV and storage systems at a cluster of public and privately owned facilities into a resilient microgrid. 4. Explore finance options and utility interconnection requirements and compensation mechanisms. 5. Summarize outcomes and next steps for town leadership.

25 ENERGY STORAGE↗

Efficient Anomaly Detection Driven By Different Machine Learning Architectures And Models

The rapid growth and ubiquitous adoption of the internet and cyber-physical systems (CPS) have fundamentally transformed modern communication, work, and human-system interactions. While networks now form the backbone of critical digital ecosystems, enabling seamless data transmission across diverse, interconnected systems, this increased connectivity also expands the attack surface, making real-time detection of network intrusions and anomalies a pressing challenge. Detecting unusual activities within network infrastructure requires advanced data traffic analysis to differentiate between legitimate and malicious interactions. Traditional approaches to network anomaly detectionâ??such as rule-based and signature-based systemsâ??often depend on predefined patterns to identify known anomalies, limiting their effectiveness against emerging, stealthy, or previously unseen threats. These conventional methods suffer from high false alarm rates and fail to adapt to the ever-evolving nature of network traffic, particularly in large-scale, decentralized environments where data volume, velocity, and variety are constantly increasing. This dissertation presents artificial intelligence (AI)-driven approaches to anomaly detection that leverage graphics processing unit (GPU)-enabled high-performance computing (HPC) platforms for processing massive network traffic data and monitoring the components of cyber-physical systems (CPS) for potentially hazardous conditions. The research advances several key contributions: (1) Designing efficient machine learning techniques for CPS condition monitoring and anomaly detection; (2) enabling federated learning (FL) frameworks that enable distributed detection while preserving data privacy and system resilience; (3) exploring graph-based methodologies combining graph neural networks (GNN) and graph machine learning (ML) approaches for the Internet of Things (IoT) and automotive network security, and (4) performing distributed edge computing optimizations that integrate FL with scalable technologies for reduced communication overhead. Through extensive experiments, these methodologies demonstrate that complex anomaly detection and condition monitoring tasks can be achieved while balancing computational efficiency and detection accuracy through fine-grained network information processing. The frameworks developed in this research establish a robust foundation for network anomaly detection, providing scalable, adaptive, and privacy-preserving solutions for safeguarding CPS and IoT networks in an increasingly interconnected digital landscape. The practical implications of these research findings are significant, as they can inform the development of next-generation network security systems and contribute to the protection of critical infrastructure against sophisticated cyber attacks.

Marfo, William↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architectural scaling tradeoffs in modular 3D bosonic quantum processors

We propose a modular three-dimensional bosonic quantum processor built from repeatable coupled-cavity modules linked by configurable interconnect networks. Using hardware-motivated graph-theoretic measures, we compare nearest-neighbor, hub-based, and hybrid architectures in terms of interconnect count, communication distance, resource concentration, and implementation complexity. Rather than identifying a universally optimal topology, our analysis shows how these architectures redistribute the costs of scaling, including wiring and port requirements, nonlocal communication distance, exposure to shared resources, routing bottlenecks, and scheduling overhead. Case studies of a \(3\times3\) processor and a larger hierarchical architecture further distinguish finite-size performance from asymptotic scaling. The resulting framework provides a systematic basis for evaluating modular three-dimensional bosonic processors and for identifying the device-level parameters required for quantitative hardware design.

Zhu, Shaojiang [Fermilab] (ORCID:0000000293180092)↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2025 Large Load Literature Review

This literature review catalogs more than 90 publications focused on large loads, and groups the documents and resources thematically into 12 categories, (listed below). The 2026 Large Load Literature Review and Data Sources summary reports are available here: https://emp.lbl.gov/publications/2026-large-load-literature-review -Load forecasting -Data sources -Reliability and resource adequacy -Large load interconnection -Demand flexibility -Generation -Co-location -Data center location/infrastructure -Large load tariffs -Policy options -Maps and tools -Design and operations

97 MATHEMATICS AND COMPUTING↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Scale Solar, 2024 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2024 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2023, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, net value, and interconnection queue data.

analysis↗

Engaging with Utilities and Key Stakeholders [Slides]

The Energy to Communities (E2C) peer-learning cohort program provides technical assistance to groups of 15 community entities around a common energy topic over the course of 6 months. Every month, participants join a virtual meeting where they hear from experts and exchange strategies and best practices with their peers. This cohort, "Successful Energy Project Implementation" will explore common challenges in implementing energy projects and learn strategies to turn project plans into reality. Each participant will focus on a local energy project or priority as a cornerstone for their learning throughout the series. This presentation overviews the interconnection process for distributed energy resources and how to engage well with utilities. The workshop will be held on March 25, 2026.

24 POWER TRANSMISSION AND DISTRIBUTION↗

V2XConnect: Harmonizing the Landscape of Bidirectional Charging Codes, Standards, and Communication Protocols

The utility grid is constantly evolving with new generation sources and diverse loads from backup generators, backup batteries, rooftop photovoltaics (PV), and flexible charging loads. Each of these technologies presents consumers with an opportunity to work with their local utility to promote grid stability, reliability, and affordability. Through a wide range of programs, utilities are incentivizing the use of these resources to benefit the grid. However, especially for devices with inverters that supply power back to the grid, it is important that these assets comply with local grid codes to ensure human safety, power quality, and grid reliability. One of the most promising of these new technologies is the bidirectional electric vehicle (EV) coupled with bidirectional electric vehicle supply equipment (EVSE). This report introduces the technologies that enable bidirectional charging and how these systems operate. It then outlines the necessary interconnection codes and industry standards that govern the operations of grid-tied inverters, including those in bidirectional charging. A key challenge is then outlined from the complex landscape of communication protocols and proprietary systems designed to coordinate these grid assets. Finally, a single gateway solution is proposed to harmonize communications between all assets across an entire site for a cohesive response to grid codes and utility programs that is flexible enough to support a range of market options.

33 ADVANCED PROPULSION SYSTEMS↗

Establishing Co‐Continuous Network of Conjugated Polymers and Elastomers for High‐Performance Polymer Solar Cells with Extreme Stretchability

High power conversion efficiency (PCE) and mechanical robustness are prerequisites for wearable applications of organic solar cells (OSCs). However, stretchability of present active systems (i.e., crack-onset strain (COS) < 30%) should be improved. While introducing elastomers into active systems is considered a simple method for improving stretchability, the inclusion of elastomers typically results in a decrease in PCE of the OSC with a limited enhancement in the stretchability due to lack of interconnected electrical and mechanical pathways. In this study, it is developed efficient and intrinsically stretchable (IS)-OSCs with exceptional mechanical robustness, by constructing co-continuous networks of conjugated polymers (D18) and elastomers (SEBS) within active layers. It is demonstrated that the blend film with a specific ratio (40:60 w/w) of D18:SEBS is crucial for forming co-continuous structures, establishing well-connected mechanical and electrical channels. Consequently, D18 0.4 :SEBS 0.6 /L8-BO OSCs achieve 16-times higher stretchability (COS = 126%) than the OSCs based on D18/L8-BO (COS = 8%), while achieving 4-times higher PCE (12.13%) compared to the OSCs based on SEBS-rich active layers (D18 0.2 :SEBS 0.8 /L8-BO, PCE = 3.15%). Furthermore, D18 0.4 :SEBS 0.6 -based IS-OSCs preserve 86 and 90% of original PCEs at 50% strain and after 200 stretching/releasing cycles with 15% strain, respectively, demonstrating the highest mechanical robustness among reported IS-OSCs.

14 SOLAR ENERGY↗

In‐Scribe Silane Bonding for Mechanical Reinforcement of Perovskite Photovoltaic Modules

Despite the extraordinary rise in power conversion efficiency over the last decade, metal halide perovskite (MHP) photovoltaics remain more mechanically fragile than other PV technologies. In this work, the scribe area, created by the monolithic interconnection of thin-film solar cells, is used to extrinsically reinforce the mechanical robustness of packaged MHP solar modules. In contrast to the epoxy-based chemistries often leveraged in the MHP literature, silane-grafted polyolefin encapsulants are designed to form strong covalent bonds to oxide surfaces, specifically to glass and the transparent conductive oxide at the base of the scribe line. Pseudo-modules encapsulated with silane-grafted polyolefin are measured with more than an order-of-magnitude enhancement infracture energy from 0.27 ± 0.01 J·m −2 (no scribes) to 5.97 ± 0.42 J·m −2 (scribes perpendicular to delamination directioncovering ≈2.2% of the module area). The silane-grafted polyolefin retains strong adhesion even after undergoing an accelerated IEC 61215 thermal cycling test consisting of 250 cycles. We find that the in-scribe bonding allows perovskite modules to have adhesion strength comparable to commercial c-Si and CdTe technologies with only 5% reduction in the active module area. This manufacturing-compatible approach offers a practical solution to address the mechanical integrity challenges in MHP solar modules, regardless of cell architecture.

14 SOLAR ENERGY↗

Multi‐Stage Optimization of Pore Size and Shape in Pore‐Space‐Partitioned Metal–Organic Frameworks for Highly Selective and Sensitive Benzene Capture

Abstract Compared to exploratory development of new structure types, pushing the limits of isoreticular synthesis on a high‐performance MOF platform may have higher probability of achieving targeted properties. Multi‐modular MOF platforms could offer even more opportunities by expanding the scope of isoreticular chemistry. However, navigating isoreticular chemistry towards best properties on a multi‐modular platform is challenging due to multiple interconnected pathways. Here on the multi‐modular pacs (partitioned acs) platform, we demonstrate accessibility to a new regime of pore geometry using two independently adjustable modules (framework‐forming module 1 and pore‐partitioning module 2). A series of new pacs materials have been made. Benzene/cyclohexane selectivity is tuned, progressively, from 4.5 to 15.6 to 195.4 and to 482.5 by pushing the boundary of the pacs platform towards the smallest modules known so far. The exceptional stability of these materials in retaining both porosity and single crystallinity enables single‐crystal diffraction studies of different crystal forms (as‐synthesized, activated, guest‐loaded) that help reveal the mechanistic aspects of adsorption in pacs materials.

Chen, Yichong↗

Multi–Stage Optimization of Pore Size and Shape in Pore–Space–Partitioned Metal–Organic Frameworks for Highly Selective and Sensitive Benzene Capture

Compared to exploratory development of new structure types, pushing the limits of isoreticular synthesis on a high-performance MOF platform may have higher probability of achieving targeted properties. Multi-modular MOF platforms could offer even more opportunities by expanding the scope of isoreticular chemistry. However, navigating isoreticular chemistry towards best properties on a multi-modular platform is challenging due to multiple interconnected pathways. Here on the multi-modular pacs (partitioned acs) platform, we demonstrate accessibility to a new regime of pore geometry using two independently adjustable modules (framework-forming module 1 and pore-partitioning module 2). A series of new pacs materials have been made. Benzene/cyclohexane selectivity is tuned, progressively, from 4.5 to 15.6 to 195.4 and to 482.5 by pushing the boundary of the pacs platform towards the smallest modules known so far. The exceptional stability of these materials in retaining both porosity and single crystallinity enables single-crystal diffraction studies of different crystal forms (as-synthesized, activated, guest-loaded) that help reveal the mechanistic aspects of adsorption in pacs materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Li 21 Ge 8 P 3 S 34 : New Lithium Superionic Conductor with Unprecedented Structural Type

Abstract Lithium superionic conductors are pivotal for enabling all‐solid‐state batteries, which aim to replace liquid electrolytes and enhance safety. Herein, we report the discovery of an unprecedented lithium superionic conductor, Li 21 Ge 8 P 3 S 34 , featuring a novel structural type and a new composition in the Li–Ge–P–S system. This material exhibits high lithium ionic conductivity of approximately 1.0 mS cm −1 at 303 K with a low activation energy of 0.20(1) eV. It's unique crystal structure was elucidated using three‐dimensional electron diffraction (3D ED) and further refined through combined powder X‐ray and neutron diffraction analyses. The structure consists of alternating two‐dimensional slabs: one of corner‐sharing GeS 4 tetrahedra and the other of isolated PS 4 tetrahedra, enabling efficient lithium‐ion transport through a tetrahedrally interconnected network of 1D, 2D, and 3D diffusion pathways. This distinctive structural motif provides a novel design strategy for next‐generation solid electrolytes, broadening the structural landscape of lithium superionic conductors. With further advancements in compositional tuning and interfacial engineering, Li 21 Ge 8 P 3 S 34 could contribute to the development of high‐performance all‐solid‐state batteries.

Chemistry↗