Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverter testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Power processor for a 20CM ion thruster

A power processor breadboard for the JPL 20CM Ion Engine was designed, fabricated, and tested to determine compliance with the electrical specification. The power processor breadboard used the silicon-controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to the ion engine. The breadboard power processor was integrated with the JPL 20CM ion engine and complete testing was performed. The integration tests were performed without any silicon-controlled rectifier failure. This demonstrated the ruggedness of the series resonant inverter in protecting the switching elements during arcing in the ion engine. A method of fault clearing the ion engine and returning back to normal operation without elaborate sequencing and timing control logic was evolved. In this method, the main vaporizer was turned off and the discharge current limit was reduced when an overload existed on the screen/accelerator supply. After the high voltage returned to normal, both the main vaporizer and the discharge were returned to normal.

Biess, J. J.↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

A schematic and physical layout is given for the 5kW integrated system and the development status of individual components is described. The results of using a one dimensional mathematical model of the 5kW reformer are presented. Plans for a single-tube reformer test unit for the acquisition of temperature profile data are described. Tentative specifications for a 50kW dc-to-ac inverter are listed. Performance data are given on two 3-cell stacks incorporating semiautomatic acid replenishment systems and improved electrocatalysts. A qualification test on methanol/steam reforming catalyst T2107RS is reported, including a portion in which the catalyst was deliberately poisoned with 800 ppm ethanol in the feed.

Source record↗

Road load simulator tests of the Gould phase 1 functional model silicon controlled rectifier ac motor controller for electric vehicles

The test results for a functional model ac motor controller for electric vehicles and a three-phase induction motor which were dynamically tested on the Lewis Research Center road load simulator are presented. Results show that the controller has the capability to meet the SAE-J227a D cycle test schedule and to accelerate a 1576-kg (3456-lb) simulated vehicle to a cruise speed of 88.5 km/hr (55 mph). Combined motor controller efficiency is 72 percent and the power inverter efficiency alone is 89 percent for the cruise region of the D cycle. Steady state test results for motoring, regeneration, and thermal data obtained by operating the simulator as a conventional dynamometer are in agreement with the contractor's previously reported data. The regeneration test results indicate that a reduction in energy requirements for urban driving cycles is attainable with regenerative braking. Test results and data in this report serve as a data base for further development of ac motor controllers and propulsion systems for electric vehicles. The controller uses state-of-the-art silicon controlled rectifier (SCR) power semiconductors and microprocessor-based logic and control circuitry. The controller was developed by Gould Laboratories under a Lewis contract for the Department of Energy's Electric and Hybrid Vehicle program.

Gourash, F.↗

An SCR inverter for electric vehicles

An inverter for an electric vehicle propulsion application has been designed and constructed to excite a polyphase induction motor from a fixed propulsion battery source. The inverter, rated at 35kW peak power, is fully regenerative and permits vehicle operation in both the forward and reverse directions. Thyristors are employed as the power switching devices arranged in a dc bus commutated topology. This paper describes the major role the controller plays in generating the motor excitation voltage and frequency to deliver performance similar to dc systems. Motoring efficiency test data for the controller are presented. It is concluded that an SCR inverter in conjunction with an ac induction motor is a viable alternative to present dc vehicle propulsion systems on the basis of performance and size criteria.

Latos, T.↗

Optimization-Based Model Reduction Scheme for Renewable Energy Power Plants Using Standardized Testing Scenarios

This paper presents an optimization-based model reduction scheme for renewable energy (RE) power plants consisting of inverter-based resources (IBRs) operating in grid-following (GFL) or grid-forming (GFM) modes. More importantly, the datasets feeding the optimization-based model reduction scheme are generated and re-used through the standardized grid-interactive testing scenarios. Particularly, the proposed scheme makes use of the power plant point of common coupling (PCC) measurements of various quantities specified by standardized tests (e.g., voltage and frequency ride through) as per IEEE 2800, to estimate the parameters of the reduced-order model such that its dynamic performance aligns with the original detailed power plant model. The proposed model reduction approach does not require the parameters of individual IBRs and using standardized test data as input to the formulated optimization problem simplifies the reduced-order modelling scheme. Extensive case studies following standardized test scenarios verified the remarkable accuracy of the proposed approach.

Yallamilli, Ram S. [Purdue University]↗

The aerodynamic characteristics of airfoils at negative angles of attack

A number of airfoils, including 14 commonly used airfoils and 10 NACA airfoils, were tested through the negative angle-of-attack range in the NACA variable-density wind tunnel at a Reynolds Number of approximately 3,000,000. The tests were made to supply data to serve as a basis for the structural design of airplanes in the inverted flight condition. In order to make the results immediately available for this purpose they are presented herein in preliminary form, together with results of previous tests of the airfoils at positive angles of attack. An analysis of the results made to find the variation of the ratio of the maximum negative lift coefficient to the maximum positive lift coefficient led to the following conclusions: 1) For airfoils of a given thickness, the ratio -C(sub L max) / +C(sub L max) tends to decrease as the mean camber is increased. 2) For airfoils of a given mean camber, the ratio -C(sub L max) / +C(sub L max) tends to increase as the thickness increases.

Anderson, Raymond F↗

The 30-cm ion thruster power processor

A power processor unit for powering and controlling the 30 cm Mercury Electron-Bombardment Ion Thruster was designed, fabricated, and tested. The unit uses a unique and highly efficient transistor bridge inverter power stage in its implementation. The system operated from a 200 to 400 V dc input power bus, provides 12 independently controllable and closely regulated dc power outputs, and has an overall power conditioning capacity of 3.5 kW. Protective circuitry was incorporated as an integral part of the design to assure failure-free operation during transient and steady-state load faults. The implemented unit demonstrated an electrical efficiency between 91.5 and 91.9 at its nominal rated load over the 200 to 400 V dc input bus range.

Herron, B. G.↗

MAGSAT scalar anomalies

To facilitate processing large data arrays, elements of spherical Earth analysis programs NVERTSM, SMFLD, NVERTG and GLFD were implemented and tested on the LARS IBM 4341 computer. Currently, the problem of inverting 2 deg MAGSAT scalar anomalies for the region (80 W, 60 E) longitude and (40 S, 70 N) latitude is being implemented on the LARS-computer for quantitative comparison with free air gravity anomaly, geothermal and tectonic data. Gravity and MAGSAT anomalies from a subset of this region (30 W, 60 E), (40 S, 70 N) were already processed for a paper on satellite magnetic anomalies of Africa and Europe.

Braile, L. W.↗

Control of multiple resonant power processors in a multi-source system

Analysis and test results show that phasor-regulated, Mapham-derived resonant inverters can be paralleled to provide standardizing interfaces for multiple sources on a utility-type, aerospace power distribution bus. The basic sources do not require matching in any way, and may have grossly different characteristics. Fully stable system architectures with multiple sources, parallel/redundant distribution buses, and a wide variety of loads can be easily constructed and controlled. The commands and parameters available for system control allow for tight tolerance bus voltage control, and absolute power-sharing control from the various sources over the full range of possible source and load variations. That level of control enables simplified load power processing hardware and the distribution of losses to optimally load the source thermal control system. Positive control of all system performance and allocation of losses are not required by all missions or vehicles, and overall vehicle considerations do not always require the loads on vehicle energy sources and thermal control systems to be balanced. In those cases, power system control can be simplified, and a hierarchical set of defaults can be substituted for computer-generated or supervisory input commands to allow for stable, fully autonomous system operation.

Mildice, James↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter

The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short 1 , Short 2 , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short 2 with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. Here, a 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.

42 ENGINEERING↗

Power conditioning equipment for a thermoelectric outer planet spacecraft, volume 1, book 2

The design and development of power conditioning equipment for the thermoelectric outer planet spacecraft program are considered. One major aspect of the program included the design, assembly and test of various breadboard power conditioning elements. Among others these included a quad-redundant shunt regulator, a high voltage traveling wave tube dc-to-dc converter, two-phase gyro inverters and numerous solid state switching circuits. Many of these elements were arranged in a typical subsystem configuration and tests were conducted which demonstrated basic element compatibility. In parallel with the development of the basic power conditioning elements, system studies were continued. The salient features of the selected power subsystem configuration are presented.

Andrews, R. E.↗

Ultracapacitor-Based Uninterrupted Power Supply System

The ultracapacitor-based uninterrupted power supply (UPS) system enhances system reliability; reduces life-of-system, maintenance, and downtime costs; and greatly reduces environmental impact when compared to conventional UPS energy storage systems. This design provides power when required and absorbs power when required to smooth the system load and also has excellent low-temperature performance. The UPS used during hardware tests at Glenn is an efficient, compact, maintenance-free, rack-mount, pure sine-wave inverter unit. The UPS provides a continuous output power up to 1,700 W with a surge rating of 1,870 W for up to one minute at a nominal output voltage of 115 VAC. The ultracapacitor energy storage system tested in conjunction with the UPS is rated at 5.8 F. This is a bank of ten symmetric ultracapacitor modules. Each module is actively balanced using a linear voltage balancing technique in which the cell-to-cell leakage is dependent upon the imbalance of the individual cells. The ultracapacitors are charged by a DC power supply, which can provide up to 300 VDC at 4 A. A constant-voltage, constant-current power supply was selected for this application. The long life of ultracapacitors greatly enhances system reliability, which is significant in critical applications such as medical power systems and space power systems. The energy storage system can usually last longer than the application, given its 20-year life span. This means that the ultracapacitors will probably never need to be replaced and disposed of, whereas batteries require frequent replacement and disposal. The charge-discharge efficiency of rechargeable batteries is approximately 50 percent, and after some hundreds of charges and discharges, they must be replaced. The charge-discharge efficiency of ultracapacitors exceeds 90 percent, and can accept more than a million charges and discharges. Thus, there is a significant energy savings through the efficiency improvement, and there is far less downtime for applications and labor involved in replacing an ultracapacitor versus batteries. Also, the lengthy lifespan of this design would greatly reduce the disposal problems posed by lead acid, nickel cadmium, lithium, and nickel metal hydride batteries. This innovation is recyclable by nature, which further reduces system costs. The disposal of ultracapacitors is simple, as they are constructed of non-hazardous components. They are also safer than batteries in that they can be easily discharged, and left indefinitely in a safe, discharged state where batteries cannot.

Eichenberg, Dennis J.↗

Development of a container for handling, testing, and storing discrete microelectronic components

A container has been developed for handling, testing, burning-in, and storing discrete microelectronic components without removal from the protective package. The package was designed to accommodate the leadless inverted device and other carrier-mounted active devices and chip-type discrete resistors and capacitors. Before the indicated development, components were handled and tested in various ways, some of which resulted in damage or contamination. The basic design of the container utilizes precision machined printed circuit boards and chemically milled (photoetched) contact springs. Included in this design for protection is an O-ring-sealed cover. Methods of fabrication and limitations of the current hardware are presented. Current applications of and possible extensions to the technology are discussed.

Filip, G. L.↗

Implementation of WBG devices in circuits - Electric Drive Technologies Project (Final Technical Report)

The objective of the project is to ensure that SiC devices are reliable and rugged as required in automotive applications for operational life of 300,000 hrs and create new device designs to address various weaknesses in currently available commercial devices. OSU has worked closely with SUNY Polytechnic. OSU has carried out the reliability and ruggedness evaluations of commercial devices as well as those fabricated by SUNY Polytechnic, discussed the results with SUNY Poly, and collaborated with the PI at SUNY Poly to improve the designs with respect to reliability/ruggedness. OSU work focused on reliability/ruggedness evaluation of SiC devices by individually testing them and then evaluate them in a 10 kW, 3 phase inverter system built with a specific purpose of stressing devices using realistic drive cycles such as a 10-minute hill climb. It should be noted that the primary purpose of the 10 kW inverter is to provide a platform for stressing the SiC devices under accelerated but realistic drive conditions.

33 ADVANCED PROPULSION SYSTEMS↗