Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

168 records · Page 10

Laser Scribing for Electrode Patterning of Perovskite Spectrometer-Grade CsPbBr 3 Gamma-ray Detectors

Making semiconductor radiation detectors that work at room temperature relies heavily on the deposition and pixelation of electrodes. Electrode patterning of perovskite solar cells widely implements laser scribing techniques, which is a convenient, scalable, and inexpensive technique. However, this method has not found its application in radiation detector patterning yet, and the question whether laser scribing can achieve high-quality patterns with minimum damage to a detector crystal and low interpixel cross-talk remains largely unanswered. To prove that laser scribing is a practical method for electrode patterning on perovskite CsPbBr 3 detectors, we use the material to create a variety of patterns. A very low lateral leakage current (60 nA at 10 V) and high mobility-lifetime product (9.7(3) x 10 -4 cm 2 /V) were observed between the pixel and the guard ring in tests of single-pixel devices with a separation of 200 or 100 μm between the central electrode and the guard ring. The 122 and 136 keV photopeaks in 57 Co gamma-ray spectra were very well resolved with an energy resolution of up to 6.1% at 122 keV. Finally, a further reduction in gap size to 50 mu m is conceivable, but more process optimization is needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Lizard-inspired Tube Inspector (LTI) Robot

This final report summarizes the research findings of the current project. This project is a collaboration between New Mexico State University (NMSU) as a lead (Recipient) and Arizona State University (ASU) as a Co-Recipient. Tubular structures are common components of boilers and heat exchangers in power plants. Over time, these components may suffer corrosion, cracks, and stress-corrosion cracks in either the body or the welded connections. A single tube leakage can cause an outage of several weeks. Regular inspection is a key safety factor when ensuring that power plants are maintained in reliable, operational condition. This inspection, however, is challenging, time-consuming, and in many cases impossible due to accessibility issues and safety concerns. Recent developments in robotic-based inspection can offer a great solution. Hard-to-reach places can be inspected without overhauling the unit, saving time and cost. Although several robots have been designed and implemented successfully for inspecting power plant components, in particular tubular structures, their mobility and flexibility are limited. Most of these robots use wheels for mobility which reduces their maneuverability of these robots. Moreover, they usually use magnets to attach to tubes which will not work on tubes with non-ferromagnetic materials. These robots usually carry measurement tools for a particular non-destructive testing (NDT) method such as ultrasound testing (UT) that requires a couplant to perform a point-by-point (scanning) inspection of the tubular structure. In this project, we developed a versatile lizard-inspired tube inspector (LTI) robot with embedded inspection sensing components for tube inspection which removes the need for point-by-point scanning of tube surface for crack and corrosion detection. Inspired by a “lizard”, the novelty of the current project is the integration of couplant-free ultrasound sensing and transmission, advanced data-driven defect detection and imaging, and friction-based mechanical mobility components in a single robot to eliminate a need for smooth surfaces and simple geometry for mobility and scanning. The LTI robot could replace the wheel-based approach with friction-based mobility to significantly increase the flexibility and maneuverability of the robot. The LTI robot can get into a power plant unit, such as a boiler, from a small area allowing it to access a component of interest for inspection (e.g., move on OD, curved and flat surfaces, non-ferromagnetic or ferromagnetic materials, and tubes with rough surfaces and complex geometries). Additionally, an advanced data-driven method using ultrasound data was pioneered to allow the robot to detect defects in the entire area between the robot’s multi-functional mobility system (grippers). Integrating a couplant-free ultrasound sensing in the robot’s grippers as well as using advanced data-driven methods allowed the LTI to detect defects in the entire cross-section of a tube using its grippers when stationary and when mobile.

20 FOSSIL-FUELED POWER PLANTS↗

The effects of well damage and completion designs on geoelectrical responses in mature wellbore environments

Well integrity is one of the major concerns in long-term geologic storage sites due to the potential risk of well leakage and groundwater contamination. Evaluating changes in electrical responses due to energized steel-cased wells has the potential to quantify and predict possible wellbore failures because any kind of breakage or corrosion along highly conductive well casings will have an impact on the distribution of the subsurface electrical potential. However, realistic wellbore-geoelectrical models that can fully capture fine-scale details of well completion design and the state of well damage at the field scale require extensive computational effort, or they can even be intractable to simulate. To overcome this computational burden while still keeping the model realistic, we have used the hierarchical finite-element method that represents electrical conductivity at each dimensional component (1D edges, 2D planes, and 3D cells) of a tetrahedral mesh. This allows well completion designs with real-life geometric scales and well systems with realistic, detailed, progressive corrosion and damage in our models. We have developed a comparison of possible discretization approaches of a multicasing completion design in the finite-element model. The effects of the surface casing and the coupling between concentric well casings as well as the effects of the degree and the location of well damage on the electrical responses are also examined. As a result, we analyze real surface electric field data to detect wellbore integrity failure associated with damage.

58 GEOSCIENCES↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispersion Leverage Coronagraph: a nulling coronagraph for use on primary objective grating telescopes

Here, we present the Dispersion Leverage Coronagraph (DLC), a variation of the Achromatic Interfero Coronagraph (AIC) that is designed for optical systems featuring large, dispersive primary objective gratings. DLC was originally designed for the Diffractive Interfero Coronagraph Exoplanet Resolver (DICER), a notional 20 m class infrared space telescope utilizing the enhanced one-dimensional angular resolution of large diffraction gratings to discover and characterize near-Earth exoplanets. Here we develop the theoretical foundation for DLC, and apply it to DICER as an example use case. We derive important properties of the DLC system, including focal plane transmission maps, stellar leakage, residual optical path difference tolerance, and pointing error/jitter considerations. Ultimately, we found that DLC effectively nulls an on-axis target across the entire spectrum in the focal plane, allowing for 2D/λ diffraction-limited imaging. It requires asymmetrical fine-guidance tolerances on pointing error/jitter. We work through a benchmark DICER design, explaining the need for a second disperser to reduce background from Zodiacal light, and showing that it could plausibly find and characterize ∼4 nearby, habitable exoplanets around Sun-like stars in a 7-year mission; about 30% of the habitable exoplanets within 8 pc were found in our simulation. The DLC may be useful for any application requiring extremely high-resolution, close companion spectroscopy.

AIC↗

CO2 Capture Strategies via Mineralization with Industrial Waste Brines

Large coal-fired power plants (>500 MW) account for 30% of global CO2 emissions, and long-term management of this CO2 to is urgently needed mitigate global temperature increases. Sequestration of CO2 within stable mineral carbonates (e.g., CaCO3) represents an attractive emission reduction strategy because it offers a leakage-free alternative to geological storage of CO2 in an environmentally friendly form. We have previously described a mineralization process in which divalent cations are sourced from various waste streams (e.g., produced water and brackish water) and alkalinity is induced via regenerable ion-exchange materials (Bustillos et. al. Frontiers in Energy Research. 2020, 8, 352). In our process, aqueous carbonate-bearing streams with pH > 8 are produced by contacting fresh water and carbon dioxide with various ion-exchange materials (e.g., Na form zeolites or ion exchange resins). These streams are mixed with produced water containing varying concentrations (~0.01 – 1.0 M) of Ca2+ leading to the precipitation of solid calcium carbonate (PCC). This process has the advantages of using regenerable solids in a simple and continuous process to increase the pH of water by ion exchange instead of relying on the consumption of costly and unsustainable sources of alkalinity (e.g., sodium hydroxide). While once-through column experiments showed the above benefits, the same were yet to established in a steady-state process with recycle streams. In this work, we set up a process simulation to quantify the energy requirements and CO2 emissions associated with the process and seek optimal produced water compositions and CO2 concentrations (5 – 20 vol%). The process simulation was set up in ASPEN Plus using eRNTL as the thermodynamic property method and sequential modular strategy. Ion exchange alkaline solution was simulated using sodium hydroxide and validated against the experimental data obtained from once-through kinetic experiments. Nanofiltration and reverse osmosis membrane steps were also implemented for the separation of divalent cations and production of fresh water and a regeneration stream following mineralization. Sensitivity analysis was carried out using a range of produced water compositions (0.01 – 1.0 M Ca2+, 0.001 – 0.15 M Mg2+, 0.5 – 3.5 M Na+ and 0.0004 – 0.002 M Fe2+) according to the United States Geological Survey (USGS) database. Calcium carbonate yields increased with increasing CO2 concentrations and were maximized using produced water compositions with larger Ca2+ concentrations. Maximum calcium carbonate yields produced at 5 vol%, 12 vol% and 20 vol% CO2 were 2.3 mmol/L, 5.5 mmol/L, and 9.3 mmol/L, respectively, with the formation of brucite (a magnesium hydroxide phase, Mg(OH)2) and goethite (an iron hydroxide phase, FeOOH) as the primary contaminant phases (99% calcite, 0.6% brucite, 0.4% goethite), which agree with phases detected by XRD experimentally. These results indicate high purity calcium carbonate can be precipitated using industrial waste streams. Consequentially, energy consumption and net CO2 emissions were minimized where precipitated calcium carbonate was maximized for all produced water compositions and CO2 concentrations. Minimum energy consumptions were 0.21 kWh/ton CO2 processed, with 98% of the energy input required coming from the membrane filtration steps. Produced water compositions with large Na+ concentrations (> 0.5 M) were effective at reducing energy consumptions due to faster regeneration time of ion exchange materials. Additionally, calculated net CO2 emissions were negative for the process and ranged from -0.02 kg/ton CO2 to -0.15 kg/ton CO2 processed, indicating a low emission process. We will also present techno-economic assessment showing the economic benefits of the current process as an alternative to the addition of stoichiometric bases to induce alkalinity for the precipitation of CaCO3.

Simonetti, Dante↗