Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Room-temperature InGaAs detector arrays for 1.0 - 1.7 microns spectroscopy

Linear arrays of 256 element InGaAs detectors with 100 x 30 micron pixels were mounted in multiplexer packages and tested in an optical multichannel analyzer (OMA). Typical performance characteristics include dark current (-5V) of 400 picoamps and responsivities of 0.75 A/W (1.3 microns) and 0.14 A/W (0.85 microns). The 256 element exhibited a mean room-temperature dark current of under 400 picoamps when mounted in the OMA and a dynamic range over 11 bits (2000:1). Future applications, including room-temperature detector arrays for 2.5 microns and avalanche photodiode arrays for 1.0-1.7 microns, are discussed.

Olsen, G. H.↗

EVALUATION OF ACOUSTIC SNAPSHOT ARRAYS FOR ROTORCRAFT SOURCE NOISE CHARACTERIZATION

Historical development of acoustic hemispheres has required steady flight of a rotorcraft vehicle across a large linear array of microphones. The US Army, NASA, and Navy recently conducted a rotorcraft acoustics flight test in which multiple “snapshot” microphone arrays were used alongside a traditional linear microphone array. The snapshot arrays allow for a near instantaneous capture of rotorcraft acoustic emissions, without the need for steady flight. Development of the snapshot array is contained herein, and an evaluation of effectiveness of the array during adverse weather conditions. The snapshot arrays captured significant variation in acoustic emissions throughout a single run and between multiple runs of similar conditions. Hemispheres were created and modelled in land-use planning software and an investigation of A-weighted Sound Exposure Level (SEL [dBA]) was conducted. Sideline predictions of SEL compared well (within 0.1 dBA) between traditional and snapshot arrays, while centre line locations were less favourable with a difference of 1.6 dBA. Future refinement is required for the snapshot array technique, including advanced design of microphone placement and employing a semiempirical method to interpolate between measurement points, instead of the linear frequency weighting conventionally employed.

Rotorcraft↗

Evaluation of a far infrared Ge:Ga multiplexed detector array

The performance of a multielement Ge:Ga linear array under low-background conditions is investigated. On-focal plane switching is accomplished by MOSFET switches and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the responsivity was measured to be nominally 584 A/W, and the NEP was 1.0 x 10 exp -16 W/sq rt Hz. A detailed description of the test setup and the procedure is presented.

Farhoomand, Jam↗

Performance analysis of structured gradient algorithm

The structured gradient algorithm uses a structured estimate of the array correlation matrix (ACM) to estimate the gradient required for the constrained least-mean-square (LMS) algorithm. This structure reflects the structure of the exact array correlation matrix for an equispaced linear array and is obtained by spatial averaging of the elements of the noisy correlation matrix. In its standard form the LMS algorithm does not exploit the structure of the array correlation matrix. The gradient is estimated by multiplying the array output with the receiver outputs. An analysis of the two algorithms is presented to show that the covariance of the gradient estimated by the structured method is less sensitive to the look direction signal than that estimated by the standard method. The effect of the number of elements on the signal sensitivity of the two algorithms is studied.

Godara, Lal C.↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Means for phase locking the outputs of a surface emitting laser diode array

An array of diode lasers, either a two-dimensional array of surface emitting lasers, or a linear array of stripe lasers, is phase locked by a diode laser through a hologram which focuses the output of the diode laser into a set of distinct, spatially separated beams, each one focused onto the back facet of a separate diode laser of the array. The outputs of the diode lasers thus form an emitted coherent beam out of the front of the array.

Lesh, James R.↗

X-ray imaging and chemical analysis of plant roots

A linear x-ray tube having one or more x-ray sources is configured for insertion into the soil in proximity to a root system of a plant for emission of an x-ray beam detected by a linear array of one or more x-ray detectors. The linear x-ray tube and detector array may be inserted into rhizotrons previously inserted into the soil. Various combinations of multiple x-ray tubes and/or detector arrays may be utilized to customize the x-ray imaging of the root system.

Kumar, Nalin↗

Concepts for large interferometers in space

Very high angular resolution can be achieved in optical and radio astronomy through interferometers in space. Evolutionary approaches and required technological advances are presented. In the optical region a phase-coherent array, (COSMIC) starting as a four-element linear array is discussed. Combining several modules results in greatly improved resolution with a goal of combining images to obtain a single field of view with 0.004 arcsecond resolution. The angular resolution, detail and temporal coverage of radio maps obtained by ground-based Very Long Interferometry (VLBI) can be greatly improved by placing one of the stations in earth orbit. An evolutionary program leading to a large aperture VLBI observatory in space is discussed.

Morgan, S. H.↗

High-density Schottky barrier IRCCD sensors for remote sensing applications

It is pointed out that the ambitious goals envisaged for the next generation of space-borne sensors challenge the state-of-the-art in solid-state imaging technology. Studies are being conducted with the aim to provide focal plane array technology suitable for use in future Multispectral Linear Array (MLA) earth resource instruments. An important new technology for IR-image sensors involves the use of monolithic Schottky barrier infrared charge-coupled device arrays. This technology is suitable for earth sensing applications in which moderate quantum efficiency and intermediate operating temperatures are required. This IR sensor can be fabricated by using standard integrated circuit (IC) processing techniques, and it is possible to employ commercial IC grade silicon. For this reason, it is feasible to construct Schottky barrier area and line arrays with large numbers of elements and high-density designs. A Pd2Si Schottky barrier sensor for multispectral imaging in the 1 to 3.5 micron band is under development.

Elabd, H.↗

Evaluation of Potential DAS Array Geometries for the Source Physics Experiment, Phase III

Distributed Acoustic Sensing (DAS) is a rapidly developing technology that can record acoustic wavefields at high sampling rates and with dense spatial spacing difficult to achieve with seismometers. However, the geophysical community has not fully explored DAS survey parameters to characterize the ideal array design. A better quantitative understanding of DAS array behavior prior to SPE Phase III acquisition can help improve the quality of the data recorded by guiding the DAS array design. Here we use array response functions as well as beamforming and backprojection results from forward modelling calculations to assess the performance of varying DAS array geometries to record regional and local sources. A seven-sided polygon DAS array demonstrated improved capabilities for recording regional sources over segmented linear arrays, with potential improvements in recording and locating local sources. These results help reveal DAS array performance as a function of geometry.

58 GEOSCIENCES↗

The Constellation-X Focal Plane Microcalorimeter Array: An NTD-Germanium Solution

The hallmarks of Neutron Transmutation Doped (NTD) germanium cryogenic thermistors include high reliability, reproducibility, and long term stability of bulk carrier transport properties. Using micro-machined NTD Ge thermistors with integral 'flying' leads, we can now fabricate two-dimensional arrays that are built up from a series of stacked linear arrays. We believe that this modular approach of building, assembling, and perhaps replacing individual modules of detectors is essential to the successful fabrication and testing of large multi-element instruments. Details of construction are presented.

Beeman, J.↗

High-speed dual-wavelength demultiplexing and detection in a monolithic superlattice p-i-n waveguide detector array

High-speed (1 Gbit/x) dual-wavelength demultiplexing and detection in a monolithic linear array of superlattice p-i-n photodetectors in a waveguide configuration is demonstrated. A crosstalk attenuation of 28 dB was achieved between two digital transmission channels with an interchannel wavelength spacing of 30 nm. The device performance is a result of an enhanced electroabsorption due to the quantum-confined Stark effect in the superlattice p-i-n diodes.

Larsson, A.↗

Multiplexed 256 element InGaAs detector arrays for 0.8-1.7-micron room-temperature operation

InGaAs photodetectors have been configured into linear arrays of 30 x 30 micron photodetectors spaced 50 microns apart. The devices have typical responsivities of 0.9 A/W (86-percent QE) at 1.3 microns and exhibit room temperature dark currents below 100 pA. A 256-element array has been mounted in a Reticon multiplexer and configured into a PAR optical multichannel analyzer to extend spectral response out to 1.7 microns. Individual InGaAs detectors have been fabricated for response out to 2.2 microns with dark current below 1 microA (-1V) and 50-percent QE at room temperature.

Olsen, G. H.↗

Performance of multiplexed Ge:Ga detector arrays in the far infrared

The performance of two multi-element, multiplexed Ge:Ga linear arrays under low-background conditions was investigated. The on-focal switching is accomplished by MOSFET switches, and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns, and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the highest responsivity was 584 A/W, the noise equivalent power was 1.0 x 10(exp -16) W/square root of Hz, and the read noise was 6100 electrons/sample. A detailed description of the test setup and procedure is presented.

Farhoomand, Jam↗

Combustion of Interacting Droplet Arrays in a Microgravity Environment

This research program involves the study of single droplets and linear arrays of droplets in weakly-buoyant and non-bouyant environments. The primary purpose of the single droplet work was to (1) provide a data base from which to compare droplet array results and (2) to correlate the effects of buoyancy on flame shape. Traditionally convective effects in droplet combustion are represented in terms of the Reynolds number, Re, for forced convection and the Grashof number, Gr, for natural convection. Typically, corrections to the burning rate constant for convective effects are written in terms of Re or Gr(exp 1). The Stefan velocity is not included in these correlations, even though from purely physical reasons, one would expect it to be important, especially at higher burning rates. The flame distortion due to convective effects is less documented quantitatively. Kumagai and Isoda do predict flame shape in natural and forced convective flow fields. Their focus, however, was to predict the actual flame dimensions. Law and co-workers used reduced pressure, high oxidizer ambients to obtain spherical flames. This implies that buoyant flows were reduced at the low pressures, as indicated by a very small Grashof number. Ross et al, however, using scaling arguments showed that reducing the pressure does not have a large effect on the magnitude of the buoyant velocity. Struk et al showed elongated flame shapes during simulated (porous sphere) droplet combustion. The elongation of the flames was due to residual gravity levels aboard the reduced gravity aircraft on which the experiments were conducted. These flame shapes, as well as some data from the literature were interpreted based on a dimensionless grouping called the sphericity parameter, Sp. Sp is the ratio of a characteristic computed buoyant velocity to the Stefan velocity at the flame front. One purpose of the droplet arrays work is to extend the database and theories that exist for single droplets into the regime where droplet interactions are important. The eventual goal being to use the results of this work as inputs to models on spray combustion where droplets seldom burn individually; instead the combustion history of a droplet is strongly influenced by the presence of the neighboring droplets. Recently, Annamali and Ryan have summarized he current status of droplet array, cloud and spray combustion. A number of simplified theories led numerical studies of droplet vaporization/combustion where multiple droplet effects are present are now available. These theories all neglect the effect of buoyancy. Experimentally, most studies to date suffer the effects of buoyancy. It is the dominant transport mechanism in the problem. Only the works of Law and co-worker and more recently by Mikami et al were performed in an environment where buoyancy effects were small. Law and co-workers were limited to high oxygen index, low pressure ambient environments since there studies were conducted in normal gravity.

Dietrich, Daniel L.↗