Search NASA⌕ Search

SEARCH · Search NASA

Results for “microgrid controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Hierarchical Control Strategies in Multi-Building Microgrids

This paper proposes a hierarchical control system for a multi-building AC microgrid with improved inertia and immunity to communication delay. The primary level control is based on a Virtual Synchronous Generator (VSG) control and the secondary level control is enhanced with a SmithPredictor to improve the stability of the system in the presence of communication delay. Moreover, tertiary level control is proposed to effectively control active and reactive power sharing between the grid and the microgrid. Islanded and grid-connected modes of the microgrid system under study are illustrated with the help of simulation results in MATLAB Simulink environment.

Weldehawaryat, Lidya Mussie [graduate research ass↗

An Optimized Input/Output-Constrained Control Design With Application to Microgrid Operation

In this paper, a nonlinear control design is presented for systems whose input and output vectors are saturated. The proposed synthesis includes an optimal tracker as the seed controller and explicitly imposes all the relevant constraints on system input, on the rate of change in the input, and on system output by using the tools of barrier functions, input-output feedback linearization, comparison argument, Lyapunov argument, and a real-time constrained optimization. The proposed design is applied to microgrid operation with high penetration of renewable generation, where net load and variable generation must be balanced and the microgrid should be operated at an optimal or near-optimal performance level. Since traditional generation has a limited ramping rate, battery storage devices and demand responses become necessary to effectively deal with variability of renewable generation and to maintain frequency stability, but their capacities are also limited. Finally,it is shown that the proposed design is effective for coordinated control of traditional generation, storage and demand response so that the power system frequency is guaranteed to be within the required operational limits and that renewable curtailment is eliminated or minimized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testbed Demonstration of a Microgrid Building Block Prototype

With the adoption of ambitious climate action goals, the penetration level of distributed energy resources (DERs) is rapidly increasing. Microgrids are an efficient way to integrate these DERs, facilitating their operation and control. Additionally, microgrids enhance the overall resilience of the distribution system by serving critical loads both within and outside their boundaries. However, the need for substantial customized engineering leads to a high cost of development, installation and maintenance of microgrids. To address this challenge, Microgrid Building Blocks (MBB) are proposed to reduce the deployment cost of microgrids through modular, standardized design and implementation. This work presents a testbed demonstrating the integrated power conversion, control, and communication functionalities of an MBB. The testbed is formed by a real-time electromagnetic transient (EMT) simulation combined with a hardware and software prototype of MBB. The use cases supported by the MBB testbed are enumerated. The islanded operation, voltage regulation, and optimal dispatch capabilities of an MBB-based microgrid controller are validated through a case study.

Somda, Baza [Virginia Tech]↗

Novel Rotated Virtual Synchronous Generator Control for Power-Sharing in Microgrids with Complex Line Impedance

Virtual synchronous generator (VSG) control is based on the fact that the line impedance in a microgrid is highly inductive. This assumption was made due to the emulation of the stator winding of an electrical machine. This concept can affect the controllability of a microgrid with complex line impedance, generating deviations in the chosen operation point. To overcome this issue, additional techniques must be implemented. This paper describes a novel mathematical approach that uses the power line characteristics in a microgrid to rotate the power control reference frame and proposes a new control method called a “Rotated Virtual Synchronous Generator” (RVSG). This RVSG control approach integrates the effect of complex impedance on the microgrid’s operation and adjusts the reference frame accordingly to improve the system’s stability and performance. The use of this proposed mathematical approach in microgrids allows the further emulation of virtual inertia in microgrids that lack inertia. Finally, a comparison between RVSG control and the classical virtual synchronous generator method is carried out to show that it allows the improvement of the transient power response, power quality, stability, and performance, mainly in microgrids with complex line impedance.

42 ENGINEERING↗

High Penetration Microgrids Providing Grid Stability Using Frequency-Watt Control Presentation

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint.Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

13 HYDRO ENERGY↗

Diesel Generator Controller Evaluation via Controller-Hardware-in-the-Loop for Various Microgrid Operation Modes

This paper presents the Controller-Hardware-in-the-Loop (CHIL) evaluation of a diesel generator controller for various microgrid operation modes. The model of the diesel generator (governor, exciter, and primary control) is simulated in real time, and the secondary control is implemented in a real hardware controller, Woodward easYgen, which is tested via CHIL with different microgrid configurations under microgrid transition operations. The experimental results demonstrate that the control settings and configuration of the Woodward controller work correctly for different microgrids under microgrid transition operations, which provides confidence for site commissioning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Controls for Smooth Transition Operation of Networked Microgrids

Islanding sections of a distribution grid as microgrids and networking these microgrids offer promising opportunities for improving system reliability; however, this approach may need distributed energy resources (DERs) to switch between grid-connected and islanded operation without affecting the system stability. The Thevenin impedance of the power system at the DER point of common coupling changes due to networking actions. It is critical to have smooth transitions between modes to ensure stable system operation and to avoid nuisance tripping. This paper presents the design of a grid-forming (GFM)-capable inverter control scheme to reliably operate in distribution systems with networked microgrids. Control mechanisms for smooth transitions between grid-following (GFL) and GFM inverter modes are presented. First, we test the control mechanism on a simple two-source power system through electromagnetic transient (EMT) simulations using a digital real-time simulator. Then, we add multiple such DERs to the EMT model of a real-world distribution feeder and demonstrate stable operation between mode transitions during the networking of the microgrids.

grid forming controls↗

Design and Evaluation of a Model-Free Frequency Control Strategy in Islanded Microgrids with Power-Hardware-in-the-Loop Testing

The deterioration of inertial and primary frequency response of islanded microgrids has been a crucial issue for the proper operation of such microgrids. Several approaches, including inertia emulation strategies, have been proposed to improve the primary frequency response. However, the demonstrations of most inertia emulation research works are based on simulation-only testing which hinder their applicability in the field. In this paper, a novel model-free control (MFC) strategy for frequency response support in a diesel-wind microgrid system is presented, and it is tested for evaluation using a power-hardware-in-the-Ioop (PHIL) platform. The PHIL testing is one step closer to field testing since it allows real-time verification and accounts for the nonlinear grid dynamics, noise, and time delays that are usually ignored in simulation-only environments. The proposed MFC strategy is fully distributed, has low computational requirements, and can be easily implemented in resource constrained devices such as smart inverters. A PHIL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed MFC strategy.

Ferrari Maglia, Max↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems: Preprint

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Frequency Control Method for Islanded Microgrids Using Energy Storage Systems

Islanded microgrids are vulnerable to frequency fluctuations due to the presence of low-inertia distributed energy resources (DERs). Moreover, implementation of both synchronous-based and inverter-based DERs with a significant difference in inertia leads to a power imbalance between generation and consumption during transients. This results in frequency variations which might have severe consequences such as blackouts. This paper develops a control scheme for battery energy storage systems (BESSs) to enhance the dynamic response of islanded microgrids by mitigating the frequency fluctuations. A piecewise linear-elliptic (PLE) droop characteristic is proposed and employed in BESS to achieve a faster power balance between generation and consumption during transients, resulting in enhanced frequency responses. Different case studies are carried out to validate the viability of the proposed approach in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Rotated-Droop Control for Enhanced Stability and Power Decoupling in Microgrids With Complex Line Impedances

Classical droop control in microgrids predominantly assumes inductive line impedance, which simplifies implementation but causes power coupling and steady-state errors in systems with resistive and inductive lines. This paper proposes a rotated-droop control strategy for grid-forming inverters that reformulates the power equations by incorporating the magnitude and angle of the line impedance within a rotated reference frame. This method enhances the decoupling of active and reactive power dynamics without increasing complexity or requiring communication links. A small-signal state-space model was created to capture the dynamic behavior of the system under varying impedance parameters, preserving the original droop gains by rotating the power control structure. This allows eigenvalue-based stability analysis and enhances damping and transient performance. Simulation and experimental results validated the improved power-sharing performance, faster response, and robustness of the proposed method under different impedance conditions. This approach maintains the decentralized structure of the conventional droop control while enabling greater adaptability and scalability, making it suitable for modern inverter-based microgrids with dynamic topologies.

Campo-Ossa, Daniel Dario [Univ. of Puerto Rico, Ag↗

Quantum microgrid state estimation

This paper investigates the feasibility and efficiency of quantum-circuit-based algorithms for microgrid state estimation. Here, our new contributions include: (1) a general quantum state estimation (GQSE) formulation is devised for swing-bus-contained microgrids through the quantized Gaussian–Newton iteration, (2) a preconditioned quantum linear solver (PQLS) is developed for tackling the ill-conditioned GQSE with limited quantum resources, and (3) an enhanced quantum state estimation (EQSE) algorithm is further established for hierarchical-control-based microgrids with exogenous disturbances. Extensive case studies demonstrate the correctness of GQSE, PQLS and EQSE in two typical microgrids. The robustness and convergence performance of EQSE are also verified.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗