Search NASA⌕ Search

SEARCH · Search NASA

Results for “operator performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigating the impact of a multi-module operation environment on the task performance time of human operators – An explanatory study

The worldwide demand for Small Modular Reactors (SMRs) has surged in recent years due to their enhanced safety and versatility in supporting diverse industrial sectors. A unique feature of SMR operation is that a single human operator is responsible for managing multiple modules. Therefore, securing a sufficient amount of human performance data pertaining to this new environment is essential for the safe operation of SMRs. In this explanatory study, a series of experiments were conducted using the NuScale simulator, a representative SMR design, with student operators. A total of 12 student operators were assigned two types of off-normal events and asked to cope with them using paper-based procedures. Subsequently, their task performance times were compared with those of student operators responsible for a single unit based on the Task Complexity (TACOM) measure. Results indicate that the performance of student operators under the experimental conditions of this study degraded by a factor of 2 to 3, depending on the characteristics of the off-normal events.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGC-1 Pre-Irradiation Data Report Status

The Next Generation Nuclear Plant (NGNP) Graphite R&D program is currently measuring irradiated material property changes in several grades of nuclear graphite for predicting their behavior and operating performance within the core of new Very High Temperature Reactor (VHTR) designs. The Advanced Graphite Creep (AGC) experiment consisting of six irradiation capsules will generate this irradiated graphite performance data for NGNP reactor operating conditions. All samples in the experiment will be fully characterized before irradiation, irradiated in the Advanced Test Reactor (ATR), and then re-examined to determine the irradiation induced changes to key materials properties in the different graphite grades. The information generated during the AGC experiment will be utilized for NRC licensing of NGNP reactor designs, shared with international collaborators in the Generation IV Information Forum (GIF), and eventually utilized in ASME design code for graphite nuclear applications. This status report will describe the process the NGNP Graphite R&D program has developed to record the AGC1 pre-irradiation examination data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-2 Disassembly Report

The Next Generation Nuclear Plant (NGNP) Graphite Research and Development (R&D) Program is currently measuring irradiated material properties for predicting the behavior and operating performance of new nuclear graphite grades available for use within the cores of new very high temperature reactor designs. The Advanced Graphite Creep (AGC) experiment, consisting of six irradiation capsules, will generate irradiated graphite performance data for NGNP reactor operating conditions. The AGC experiment is designed to determine the changes to specific material properties such as thermal diffusivity, thermal expansion, elastic modulus, mechanical strength, irradiation induced dimensional change rate, and irradiation creep for a wide variety of nuclear grade graphite types over a range of high temperature, and moderate doses. A series of six capsules containing graphite test specimens will be used to expose graphite test samples to a dose range from 1 to 7 dpa at three different temperatures (600, 900, and 1200°C) as described in the Graphite Technology Development Plan. Since irradiation induced creep within graphite components is considered critical to determining the operational life of the graphite core, some of the samples will also be exposed to an applied load to determine the creep rate for each graphite type under both temperature and neutron flux. All six AGC capsules in the experiment will be irradiated in the Advanced Test Reactor (ATR). AGC-1 and AGC-2 will be irradiated in the south flux trap and AGC-3–AGC-6 will be irradiated in the east flux trap. The change in flux traps is due to NGNP irradiation priorities requiring the AGC experiment to be moved to accommodate Fuel irradiation experiments. After irradiation, all six AGC capsules will be cooled in the ATR Canal, sized for shipment, and shipped to the Materials and Fuels Complex (MFC) where the capsule will be disassembled in the Hot Fuel Examination Facility (HFEF). During disassembly, the metallic capsule will be machined open and the individual samples removed from the interior graphite body containing the samples. Samples removed from the capsule will be loaded in a shipping drum and shipped to the Idaho National Laboratory (INL) Research Center (IRC) for initial post-irradiation examination (PIE) and storage for any future testing at the newly completed Carbon Characterization Laboratory (CCL). All work was performed under an ASME NQA-1-2008;1a-2009 compliant quality assurance program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-1 Post Irradiation Examination Status

The Next Generation Nuclear Plant (NGNP) Graphite R&D program is currently measuring irradiated material property changes in several grades of nuclear graphite for predicting their behavior and operating performance within the core of new Very High Temperature Reactor (VHTR) designs. The Advanced Graphite Creep (AGC) experiment consisting of six irradiation capsules will generate this irradiated graphite performance data for NGNP reactor operating conditions. All six AGC capsules in the experiment will be irradiated in the Advanced Test Reactor (ATR), disassembled in the Hot Fuel Examination Facility (HFEF), and examined at the INL Research Center (IRC) or Oak Ridge National Laboratory (ORNL). This is the first in a series of status reports on the progress of the AGC experiment. As the first capsule, AGC1 was irradiated from September 2009 to January 2011 to a maximum dose level of 6-7 dpa. The capsule was removed from ATR and transferred to the HFEF in April 2011 where the capsule was disassembled and test specimens extracted from the capsules. The first irradiated samples from AGC1 were shipped to the IRC in July 2011and initial post irradiation examination (PIE) activities were begun on the first 37 samples received. PIE activities continue for the remainder of the AGC1 specimen as they are received at the IRC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transit Bus Electrification Evaluation from GPS Speed Traces

Through the USAID-NREL partnership, the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) has evaluated the potential for transit bus electrification in Mexico City and two locations in León, Mexico to inform future vehicle and infrastructure purchases. NREL collected IHz GPS data between September to October of 2017 from the existing transit buses as inputs to the Future Automotive Systems Technology Simulator (FASTSim) tool. NREL used the data and FASTSim models to provide detailed operational performance requirements of electric buses operated within the context of the three locations and highlighted bus operations that are candidates for electrification.

ADVANCED PROPULSION SYSTEMS↗

Production Facility Prototype Blower Installation Report with 1000 Hour Test Results

The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is currently being installed at the LANL facility for target and component flow testing. This report describes this blower/motor/pressure vessel package and the status of the facility preparations. The blower has been operated for 1000 hours as a preliminary investigation of long term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are reported.

43 PARTICLE ACCELERATORS↗

Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room

Human factors researchers at Idaho National Laboratory are collaborating with a utility partner to address human factors in the modernization of their radiological waste control room. The collaborating utility, Palo Verde, plans to remove all control boards associated with the liquid radiological waste system, which include controls, indicators, and alarm systems, and replace them with modernized digital instrumentation and controls and displays. To be sure the new system either supports current operational performance or enhances it, researchers have carried out three planning and analysis activities: expert operator review, function allocation analysis, and human factor principles and design applications. Researchers utilized access to expert operators to gain information about the system. Operators were asked to detail a procedure exemplifying typical interactions with the liquid radiological waste system and provide it to Idaho National Laboratory with a list of functionalities to incorporate (Section 4.1). Later, operators were asked to provide additional feedback to inform a prototype with adequate realism to support sound analysis of the system design (Section 4.2). Other operators not associated with the utility partner were also involved in experiment design and prototype evaluation (Section 4.2). Due to the extent of the upgrade, care was given to measure the change in the operator’s role (Section 7). As part of the modernization, some plant systems are expected to be equipped with automation or sensors that send information directly to the control where previously operators were required to enter controlled areas to find the information. Such updates made slight changes to operator role requirements, but the impact was negligible. The way the system is operated will remain largely the same, but operator convenience and safety is expected to increase. Additionally, to map operator tasks during the selected procedure, an Operational Sequence Diagram was created (Section 7.1). The diagram helped to account for every interaction and piece of equipment needed to create the prototype design. Alternatively, the diagram can be created following the final design to identify any function reallocations due to redesign. Human factors principles were also applied to the design. An ergonomic assessment was performed on the workspace resulting in various recommendations for placing and designing the new workstation (Section 6). A 3 D mockup of the control room was created to depict the options available with in-depth descriptions of each. Furthermore the prototype design incorporates well known human factors principles. However, to be sure the principles are sound in the control room context, the researches have designed an experiment to measure the impact design decision has on operator performance. The experiment is described in detail in Section 5. Lastly, a tool emerged as this effort began called the NUREG 0711 Crosswalk (Section 8). The tool has multiple uses, but it was primarily intended to communicate how the researcher’s action directly mapped to specific results suggested in the Nuclear Regulatory Commission review guideline. The tool also maps how current results impact future decisions in the modernization process.

47 OTHER INSTRUMENTATION↗

Production Facility Prototype Blower 1000 Hour Test Results

The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is now installed at the LANL facility for target and component flow testing. Two extended tests of >1000 hr operation have been completed. Those results and discussion thereof are reported herein. Also included in Appendix A is the detailed description of the blower and its installation, while Appendix B documents the pressure vessel design analysis. The blower has been operated for 1000 hours as a preliminary investigation of long-term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are in Appendix B.

43 PARTICLE ACCELERATORS↗

Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). Furthermore, it is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning technique using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

43 PARTICLE ACCELERATORS↗

Evaluation of HVAC & refrigeration system fault behaviors and impacts: A systematic review

Achieving the goals of green buildings critically depends on the fault-free operation of heating, ventilation and air conditioning and refrigeration (HVAC&R) systems. However, faults frequently occur in these systems, causing a range of negative consequences, including increased energy consumption, diminished operational performance, compromised indoor environmental quality, higher operational costs, and shortened system lifespan. The evaluation of fault behaviors and impacts plays a critical role in revealing fault characteristics and consequently supports many research areas, including the design of the high-performance equipment, development of fault detection and diagnostics (FDD) and robust control approaches, as well as the enhancement of maintenance decision-making activities. This paper systematically reviews 112 research publications that reported the analysis and evaluation of fault behaviors and impacts in HVAC&R systems over the past thirty years. Here, we designed a review approach to address five crucial research questions, namely: 1) the objectives of analysis and evaluation of fault behaviors and impacts, 2) data sources, 3) equipment/system types and fault types, 4) evaluation methods including evaluation measures and associated metrics, and 5) challenges and future directions in the research on evaluating of fault behaviors and impacts. In-depth discussions on these questions help bridge the gap between the evaluation of fault behaviors and impacts and their practical applications, such as the development of high-performance systems, fault models, FDD methods, and maintenance decision-making tools within the HVAC&R FDD domain.

Chen, Yimin [Oak Ridge National Laboratory (ORNL),↗

A Computuerized Operator Support System Prototype

A report was published by the Idaho National Laboratory in September of 2012, entitled Design to Achieve Fault Tolerance and Resilience, which described the benefits of automating operator actions for transients. The report identified situations in which providing additional automation in lieu of operator actions would be advantageous. It recognized that managing certain plant upsets is sometimes limited by the operator’s ability to quickly diagnose the fault and to take the needed actions in the time available. Undoubtedly, technology is underutilized in the nuclear power industry for operator assistance during plant faults and operating transients. In contrast, other industry sectors have amply demonstrated that various forms of operator advisory systems can enhance operator performance while maintaining the role and responsibility of the operator as the independent and ultimate decision-maker. A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS does not supplant the role of the operator, but rather provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast-moving, complex events. This project proposes a general model for a control room COSS that addresses a sequence of general tasks required to manage any plant upset: detection, validation, diagnosis, recommendation, monitoring, and recovery. The model serves as a framework for assembling a set of technologies that can be interrelated to assist with each of these tasks. A prototype COSS has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Computuerized Operator Support System Prototype

A report was published by the Idaho National Laboratory in September of 2012, entitled Design to Achieve Fault Tolerance and Resilience, which described the benefits of automating operator actions for transients. The report identified situations in which providing additional automation in lieu of operator actions would be advantageous. It recognized that managing certain plant upsets is sometimes limited by the operator’s ability to quickly diagnose the fault and to take the needed actions in the time available. Undoubtedly, technology is underutilized in the nuclear power industry for operator assistance during plant faults and operating transients. In contrast, other industry sectors have amply demonstrated that various forms of operator advisory systems can enhance operator performance while maintaining the role and responsibility of the operator as the independent and ultimate decision-maker. A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS does not supplant the role of the operator, but rather provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast-moving, complex events. This project proposes a general model for a control room COSS that addresses a sequence of general tasks required to manage any plant upset: detection, validation, diagnosis, recommendation, monitoring, and recovery. The model serves as a framework for assembling a set of technologies that can be interrelated to assist with each of these tasks. A prototype COSS has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of Gather/Scatter Operations

In this paper we describe the performance of two operations, gather and scatter. The operations we describe are simplified versions of those used in the implementation of sparse matrix libraries such as sparse-blas. Similar operations can also be found in benchmarks such as HPCG. Gather and scatter operations are memory load and store operations that are related to other memory operations such as Stream Triad and DAXPY, but have an additional dependence between memory loads that affects performance. We describe how the operations behave on current technology and identify features that enhance their performance. However, our description of hardware is general rather than specific to a single architecture.

97 MATHEMATICS AND COMPUTING↗

Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Innovations in Sustainable Passive Wastewater Treatment - 20236

Sustainable water treatment systems, engineered to mimic natural processes and utilize natural materials, yield economic and environmental benefits through reductions in long term operational inputs, including: power, chemicals, and labor. Golder is an industry leader in the development and implementation of sustainable technologies at operating and closed mines. We continue to innovate these technologies and customize solutions to meet client needs by applying past experience and focused research. Sustainable (or passive) water treatment systems include ponds, wetlands, flow-through natural media beds, and limestone drains. These systems can blend in with a natural environment, are highly cost-effective for long-term water treatment, and can outcompete traditional active treatment technologies. Application of sustainable technologies relative to active technologies can be influenced by the influent water matrix, effluent limitations, flow rate of water requiring treatment, and available land area. In this presentation, four Golder-developed systems are reviewed as case studies, demonstrating our continued progressive approach to advancing sustainable water treatment technologies to meet industry needs. These case studies focus on design innovations and operational performance from data collected from the operational systems. Resources (power, chemicals, labor) required for the operation of each case study are compared with those that would be required for operation of their active treatment technology alternatives. - Case Study 1 presents an anaerobic biochemical reactor (BCR), a technology typically implemented for metals treatment and acid neutralization, for the treatment of sulfate to low concentrations (<250 mg/L). Active treatment via reverse osmosis (RO) membrane filtration is typically required for treatment of sulfate to similar concentrations, this innovation provides potential for sustainable treatment to replace the need for energy, chemical, labor, and waste (brine) intensive RO treatment for specific applications. Magnetite waste rock materials from the site were upcycled for use in this system to provide sequestration of the sulfide generated in the BCR. - Case Study 2 examines another novel application of the conventional BCR, modified for the removal of radionuclides and metals (uranium, radium, and selenium) at a closed uranium mine. - Case Study 3 presents implementation of sustainable treatment for mine drain water from a historic mine site, now a state park with around 100,000 visitors per year. The system includes a pond, wetland, and manganese removal bed surrounded by public trails designed to maintain the character of the park. The system treats for arsenic, iron, and manganese at relatively high flows (up to 1,200 gpm), with large seasonal fluctuations in flow and quality. - Case Study 4 is a unique project for which Golder is currently designing a sustainable treatment system, with no energy input, to treat nitrate in mine water post-closure at a site near the arctic circle. In this unprecedented application, climate, management of freshet, and space availability presented substantial technical challenges. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beam energy scan with asymmetric collision at RHIC

A beam energy scan of deuteron-gold collision, with center-of-mass energy at 19.6, 39, 62.4 and 200.7 GeV/n, was performed at the Relativistic Heavy Ion Collider in 2016 to study the threshold for quark-gluon plasma (QGP) production. The lattice, RF, stochastic cooling and other subsystems were in different configurations for the various energies. The operational challenges changed with every new energy. The operational experience at each energy, the operation performance, highlights and lessons of the beam energy scan are reviewed in this report.

43 PARTICLE ACCELERATORS↗

Design, Assembly, and Testing of a High-Resolution Relay Lens Used for Holography with Operation at Both Doubled and Tripled Nd:YAG Laser Wavelengths

The design and assembly of a nine-element lens that achieves >2000 lp/mm resolution at a 355-nm wavelength (ultraviolet) has been completed. By adding a doublet to this lens system, operation at a 532-nm wavelength (green) with >1100 lp/mm resolution is achieved. This lens is used with high-power laser light to record holograms of fast-moving ejecta particles from a shocked metal surface located inside a test package. Part of the lens and the entire test package are under vacuum with a 1-cm air gap separation. Holograms have been recorded with both doubled and tripled Nd:YAG laser light. The UV operation is very sensitive to the package window’s tilt. If this window is tilted by more than 0.1 degrees, the green operation performs with better resolution than that of the UV operation. The setup and alignment are performed with green light, but the dynamic recording can be done with either UV light or green light. A resolution plate can be temporarily placed inside the test package so that a television microscope located beyond the hologram position can archive images of resolution patterns that prove that the calibration wires, interference filter, holographic plate, and relay lenses are in their correct positions. Part of this lens is under vacuum, at the point where the laser illumination passes through a focus. Alignment and tolerancing of this high-resolution lens are presented. Resolution variation across the 12-mm field of view and throughout the 5-mm depth of field is discussed for both wavelengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bridging the gap: adapting advanced display technologies for use in hybrid control rooms

The Institute for Energy Technology (IFE), runs the OECD Halden Reactor Project (HRP), featuring a state-of-the-art research simulator facility in Halden, Norway, called HAMMLAB. HAMMLAB serves two main purposes: the study of human behaviour in interaction with complex process systems; and the development, test and evaluation of prototype control centres and their individual systems. By studying operator performance in HAMMLAB and integrating the knowledge gained into new designs, the HRP contributes to improving operational safety, reliability, efficiency and productivity. The U.S. Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program has contracted IFE to assist DOE national laboratory staff at Idaho National Laboratory (INL) in adapting HAMMLAB design concepts for the purpose of control room modernization at nuclear power plants in the U.S. In support of this effort, the DOE has built a simulator research facility at INL called the Human Systems Simulation Laboratory (HSSL). The HSSL is centered on control room modernization, in which industry provided plant instrumentation and controls are modified for upgrade opportunities. The HSSL houses the LWRS simulator, which is a reconfigurable full-scale and full-scope control room simulator. Consisting of 45 large touchscreens on 15 panels, the LWRS simulator is currently using this glass top technology to digitally represent and replicate the functionality of the analog I&C systems in existing control rooms. The LWRS simulator is reconfigurable in that different plant training simulator models obtained from the utilities can be run on the panels, and the panels can be physically moved and arranged to mimic the layout of those control rooms. The glass top technology and reconfigurability capabilities allow the LWRS simulator to be the research platform that is necessary to design, prototype, and validate human-system interface (HSI) technologies that can replace existing analog I&C. IFE has recently assisted INL in establishing the technical infrastructure for implementation of HSI prototypes from HAMMLAB into the HSSL to demonstrate relevant control room replacement systems in support of the LWRS program. In March, 2014, IFE delivered the first HSI prototype utilizing this infrastructure — a large screen overview display for INL's simulator. The co-operation now continues by developing Procedure Support Displays targeted for operators in hybrid control room settings. These prototypes are being validated with U.S. reactor operators in the HSSL and optimized to enhance their performance. This research serves as a crucial stepping stone toward incorporation of advanced display technologies into conventional main control rooms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗