Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Lithium-Ion Battery Life Model with Electrode Cracking and Early-Life Break-in Processes

This paper develops a physically justified reduced-order capacity fade model from accelerated calendar- and cycle-aging data for 32 lithium-ion (Li-ion) graphite/nickel-manganese-cobalt (NMC) cells. The large data set reveals temperature-, charge C-rate-, depth-of-discharge-, and state of charge (SOC)-dependent degradation patterns that would be unobserved in a smaller test matrix. Model structure is informed by incremental capacity analysis that shows loss of lithium inventory and cathode-material loss as the dominant capacity fade mechanisms. The model includes terms attributable to solid-electrolyte interface (SEI) growth, electrode cracking, cycling-driven acceleration of SEI growth, and "break-in" mechanisms that slightly decrease or increase available Li inventory early in life. The study explores what mathematical couplings of these mechanisms best describe calendar aging, cycle aging, and mixed calendar/cycle aging. Various approaches are discussed for extracting relevant stress factors from complex cycling profiles to predict lifetime during real-world battery loads using models trained on constant-current laboratory test results. The complexity of the present human-driven model identification process motivates future work in machine learning to more widely search and statistically discern the optimal model that correctly extrapolates capacity fade based on physical knowledge.

25 ENERGY STORAGE↗

An ultrasonic transducer with Gaussian radial velocity distribution

A transducer with a velocity profile which is Gaussian as a function of radius and independent of angle is described. In materials evaluation applications requiring the interrogation of modified far field patterns of an ultrasonic transducer, it is desirable to use a transducer which produces a beam with a Gaussian profile. A computer aided electrode design and calibrated three dimensional interferometric optical and ultrasonic measurements of the far field distribution are presented.

Zerwekh, P. S.↗

Notes on the Variety of Multipactor Patterns

The experimental results on multipactor often are not in a good agreement with theoretical predictions and numerical simulations. The experimental results can noticeably vary from test to test even in the same geometry of electrodes, depending on the material they made of and condition of their surfaces, i.e., secondary emission properties. On the other hand, an actual secondary emission yield (SEY) of electrode material is never known a priory in the experiments. In practice, the SEY data for given material used for multipactor evaluation are obtained in specialized measurements. A difference between actual and tabulated SEY of material may result in a disagreement between pre-dictions and measurements. In this work the impact of the basic SEY characteristic variations on the multipactor dynamics in a variety of coaxial and rectangular waveguides is studied. The study was performed numerically with the use of CST Particle Studio.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Changes in recruitment of Rhesus soleus and gastrocnemius muscles following a 14 day spaceflight

The effect of microgravity on the recruitment patterns of the soleus, gastrocnemius, and tibialis-anterior muscles was investigated by comparing electromyograms (EMGs) of these muscles of Rhesus monkeys implanted with EMG electrodes, taken before and after a 14-day flight on board Cosmos 2044. It was found that the EMG amplitude values in the soleus muscle decreased after the spaceflight but returned to normal values over the 2-wk recovery period. The medial amplitudes of gastrocnemius and tibialis anterior were not changed by flight. Joint probability density distributions displayed changes after flight in both the soleus and gastrocnemius muscles, but not in tibialis anterior.

Hodgson, J. A.↗

Implementation of Ion Mobility Spectrometry-Based Separations in Structures for Lossless Ion Manipulations (SLIM)

Structures for Lossless Ion Manipulations (SLIM) is a powerful variant of traveling wave ion mobility spectrometry (TW-IMS) that uses a serpentine pattern of microelectrodes deposited onto printed circuit boards to achieve ultralong ion path lengths (13.5 m). Ions are propelled through SLIM platforms via arrays of TW electrodes while RF and DC electrodes provide radial confinement, establishing near lossless transmission. The recent ability to cycle ions multiple times through a SLIM has allowed ion path lengths to exceed 1000 m, providing unprecedented separation power and the ability to observe ion structural conformations unobtainable with other IMS technologies. The combination of high separation power, high signal intensity, and the ability to couple with mass spectrometry places SLIM in the unique position of being able to address longstanding proteomics and metabolomics challenges by allowing the characterization of isomeric mixtures containing low abundance analytes.

Hollerbach, Adam L.↗

Cryogenic Characterization and Testing of Magnetically-Actuated Microshutter Arrays for the James Webb Space Telescope

Two-dimensional MEMS microshutter arrays (MSA) have been fabricated at the NASA Goddard Space Flight Center (GSFC) for the James Webb Space Telescope (JWST) to enable cryogenic (approximately 35 K) spectrographic astronomy measurements in the near-infrared region. Functioning as a focal plane object selection device, the MSA is a 2-D programmable aperture mask with fine resolution, high efficiency and high contrast. The MSA are close- packed silicon nitride shutters (cell size of 100 x 200 microns) patterned with a torsion flexure to allow opening to 90 degrees. A layer of magnetic material is deposited onto each shutter to permit magnetic actuation. Two electrodes are deposited, one onto each shutter and another onto the support structure side-wall, permitting electrostatic latching and 2-D addressing. New techniques were developed to test MSA under mission-similar conditions (8 K less than or equal to T less than 300K). The magnetic rotisserie has proven to be an excellent tool for rapid characterization of MSA. Tests conducted with the magnetic rotisserie method include accelerated cryogenic lifetesting of unpackaged 128 x 64 MSA and parallel measurement of the magneto-mechanical stiffness of shutters in pathfinder test samples containing multiple MSA designs. Lifetest results indicate a logarithmic failure rate out to approximately 10(exp 6) shutter actuations. These results have increased our understanding of failure mechanisms and provide a means to predict the overall reliability of MSA devices.

King, T. T.↗

Isotopic characterisation of prebiotic synthesis of organic material

Many primitive meteorites contain an insoluble organic material, much like terrestrial kerogen, whose mode of origin is currently unknown. When sujbected to stepwise decomposition, this material, unlike its terrestrial counterpart, reveals characteristic release patterns for the stable isotopes of carbon, hydrogen and nitrogen as a function of fractional release of each element. The purpose of this study is to try to match those release patterns using organic matter synthesised in the laboratory under controlled conditions. If successful, such a study would shed light on the origin of kerogen-like organic matter in the early solar system and, by extension, on prebiotic organic synthesis in general. The range of possible syntheses, starting materials and reaction conditions to be investigated is considerable. Samples analysed to date include: a heavy oil produced by Fischer-Tropsch-type catalysis of CO + H2; a solid residue generated by a plasma discharge in CO + H2 + N2; a solid deposited on the electrodes of a Miller-Urey synthesis operating on CH4 + H2O + N2; and a solid residue formed by polymerization of light hydrocarbons procured by a Miller-Urey discharge acting on CH4. Significant structure is observed in the release patterns for the carbon and hydrogen isotopes from the synthetic samples, though there is little evidence for isotopic fractionation during the analysis itself.

Kerridge, J. F.↗

Effect of correlated oxide electrodes on disorder pinning and thermal roughening of ferroelectric domain walls in epitaxial PbZr 0.2 Ti 0.8 O 3 thin films

We report the competing effects of disorder pinning and thermal roughening on ferroelectric domain walls as a function of temperature in epitaxial PbZr 0.2 Ti 0.8 O 3 thin films deposited on (001) SrTiO 3 substrates buffered by three types of correlated oxide electrodes, La 0.67 Sr 0.33 MnO 3 , LaNiO 3 , and SrIrO 3 . Piezo-response force microscopy studies show that the 50 nm PbZr 0.2 Ti 0.8 O 3 films are uniformly polarized in the as-grown states, with the patterned domain structures persisting above 700 °C. For all three types of films, the domain wall roughness is dominated by 2D random bond disorder at room temperature, and transitions to 1D thermal roughening upon heating. The roughness exponent ζ increases progressively from 0.3 to 0.5 within a temperature window that depends on the bottom conducting oxide type, from which we extracted the distribution of disorder pinning energy. Lastly, we discuss the possible origins of the disorder pinning and the effect of the correlated oxide electrodes on the energy landscape of DW motion.

36 MATERIALS SCIENCE↗

Co-Extrusion (CoEx) for Cost Reduction of Advanced High-Energy-and-Power Battery Electrode Manufacturing

Co-Extrusion (CoEx) is a deposition technology developed at PARC that uses engineered fluidic channels to cause multiple streams of dissimilar fluids to impart shape to one another. Here, we describe the use of CoEx to produce structured cathode electrode films to improve electrochemical performance of thick electrode films. CoEx enables us to create structured electrode films that have periodic regions of enhanced ionic conductivity, enabling higher utilization of thicker cathode films at high discharge rates. While increasing electrode thickness is a known method for increasing energy density of battery electrodes, this increase in energy density typically also results in reduced power density. This project, a collaboration between the Palo Alto Research Center, Oak Ridge National Laboratories, and Ford Motor Company, seeks to first validate the benefits of CoEx at the coin cell level, before performing the necessary R&D effort to scale production up to large (10+ Ah) pouch cells that will show increased energy density without a reduction in power density. We used conventional battery materials (commercially available NMC, PVDF, carbon black, and graphite) to produce structured electrodes via CoEx and compared them to thick and thin conventionally produced (unstructured) battery electrodes. CoEx electrodes show improved high rate performance compared to unstructured electrodes, resulting in higher energy density pouch cells compared to the baseline electrode of 7 and 11% in volumetric and gravimetric energy density, respectively. These electrodes also showed substantially improved electrochemical performance at high discharge rates compared to thick conventional electrodes.

25 ENERGY STORAGE↗

Engineering catalytical electrodes for applications in energy areas

An ink formulation and electrode that enhances hydrogen production, oxygen production, carbon dioxide reduction and other electrocatalytic reactions. Embodiments include an ink formulation with polymer binders having different catalytical precursors and a 3D electrode produced by additive manufacturing from the inventor's ink formulation. Various embodiments of the inventor's apparatus, systems, and methods provide inks that that are 3D-printed into patterns that optimize surface area and flow. The catalytic materials are imbedded into the ink matrix which is then printed into a 3D structure that has architecture that optimizes surface area and flow properties.

Liang, Siwei↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE↗

A tetrahedral probe constellation approach for measuring canonical momentum in self-organized laboratory plasma

To examine momentum redistribution processes and study generalized helicities during plasma relaxation in Madison Symmetric Torus, MST, reversed field pinch plasma, a new probe is being tested to measure the full 3D plasma ion flow and magnetic field vectors at four spatial locations arranged in a tetrahedral shape reminiscent of a satellite measurement constellation. These measurements permit calculation of ∇ x $\vec{u}$ and canonical momentum, where $\vec{u}$ is the plasma ion flow vector. The probe consists of four probe heads arranged in a tetrahedral pattern, with an overall probe diameter of ∼31.75 mm. The probe head diameter is ∼1.0 cm, which is of the order of the ion Larmor radius. Each head has four molybdenum electrodes, also arranged in tetrahedral geometry, which are biased relative to a common return electrode, using four power supplies (one for each head), to measure the local ion flow. Additionally, each head has three orthogonal magnetic pickup coils within it to measure equilibrium and fluctuating magnetic fields.

Physics - Plasma physics↗

Isolated planar gyroscope with internal radial sensing and actuation

The present invention discloses an inertial sensor comprising a planar mechanical resonator with embedded sensing and actuation for substantially in-plane vibration and having a central rigid support for the resonator. At least one excitation or torquer electrode is disposed within an interior of the resonator to excite in-plane vibration of the resonator and at least one sensing or pickoff electrode is disposed within the interior of the resonator for sensing the motion of the excited resonator. In one embodiment, the planar resonator includes a plurality of slots in an annular pattern; in another embodiment, the planar mechanical resonator comprises four masses; each embodiment having a simple degenerate pair of in-plane vibration modes.

Shcheglov, Kirill V.↗

Method of producing an inertial sensor

The present invention discloses an inertial sensor comprising a planar mechanical resonator with embedded sensing and actuation for substantially in-plane vibration and having a central rigid support for the resonator. At least one excitation or torquer electrode is disposed within an interior of the resonator to excite in-plane vibration of the resonator and at least one sensing or pickoff electrode is disposed within the interior of the resonator for sensing the motion of the excited resonator. In one embodiment, the planar resonator includes a plurality of slots in an annular pattern; in another embodiment, the planar mechanical resonator comprises four masses; each embodiment having a simple degenerate pair of in-plane vibration modes.

Shcheglov, Kirill V.↗

The Interplay Between Ferroelectricity and Electrochemical Reactivity on the Surface of Binary Ferroelectric Al x B 1–x N

Polarization dynamics and domain structure evolution in ferroelectric Al 0.93 B 0.07 N are studied using piezoresponse force microscopy and spectroscopies in ambient and controlled atmosphere environments. The application of negative unipolar and bipolar first-order reverse curve (FORC) waveforms leads to a protrusion-like feature on the Al 0.93 B 0.07 N surface and a reduction of electromechanical response due to electrochemical reactivity. A surface change is also observed on the application of fast alternating current bias. At the same time, the application of positive biases does not lead to surface changes. Comparatively in a controlled glove box atmosphere, stable polarization patterns can be observed, with minuscule changes in surface morphology. This surface morphology change is not isolated to applying biases to free surface, a similar topographical change is also observed at the electrode edges when cycling a capacitor in an ambient environment. The study suggests that surface electrochemical reactivity may have a significant impact on the functionality of this material in the ambient environment. However, even in the controlled atmosphere, the participation of the surface ions in polarization switching phenomena and ionic compensation is possible.

36 MATERIALS SCIENCE↗

Gas Sensor Test Chip

A new test chip is being developed to characterize conducting polymers used in gas sensors. The chip, a seven-layer cofired alumina substrate with gold electrodes, contains 11 comb and U- bend test structures. These structures are designed to measure the sheet resistance, conduction anisotropy, and peripheral conduction of spin-coated films that are not subsequently patterned.

conducting polymers gas sensors test chipnd periph↗

Effect of the grain arrangements on the thermal stability of polycrystalline nickel-rich lithium-based battery cathodes

One of the most challenging aspects of developing high-energy lithium-based batteries is the structural and (electro)chemical stability of Ni-rich active cathode materials at thermally-abused and prolonged cell cycling conditions. Here, we report in situ physicochemical characterizations to improve the fundamental understanding of the degradation mechanism of charged polycrystalline Ni-rich cathodes at elevated temperatures (e.g., ≥ 40 °C). Using multiple microscopy, scattering, thermal, and electrochemical probes, we decouple the major contributors for the thermal instability from intertwined factors. Our research work demonstrates that the grain microstructures play an essential role in the thermal stability of polycrystalline lithium-based positive battery electrodes. We also show that the oxygen release, a crucial process during battery thermal runaway, can be regulated by engineering grain arrangements. Furthermore, the grain arrangements can also modulate the macroscopic crystallographic transformation pattern and oxygen diffusion length in layered oxide cathode materials.

36 MATERIALS SCIENCE↗